1.
Polymers (Basel) ; 15(15)2023 Jul 26.
Article in English | MEDLINE | ID: mdl-37571072

ABSTRACT

An investigation into the inspection capabilities of in-field advanced ultrasound detection for use on ultra-thick (20 to 100 mm) glass fibre-reinforced polyester composites is presented. Plates were manufactured using custom moulding techniques, such that delamination flaws were created at calibrated depths. The full matrix capture technique with an on-board total focussing method was used to detect flaws scanned by a 0.5 MHz linear array probe. Flaw through-thickness dimensions were altered to assess the threshold for crack face separation at which delaminations could be identified. Furthermore, part thickness and in-plane flaw dimensions were varied to identify the inspection capability limitations of advanced ultrasonics for thick composites. The results presented in this study demonstrate an inverse relationship between the ability to find delaminations and plate thicknesses, with inspections successful at depths up to 74 mm. When the delamination thickness exhibited surface-to-surface contact, the inspection capability was reduced to 35 mm. There was an exponential decay relationship between the accuracy of the flaw depth measurement and plate thickness, likely due to the necessity of low probe frequencies. The effective inspection depth was determined to be in the range of 1 to 20 times the wavelength. It is speculated that the accuracy of measurements could be improved using probes with novel coupling solutions, and detectors with optimised signal processing/filtration algorithms.

2.
Polymers (Basel) ; 13(23)2021 Nov 25.
Article in English | MEDLINE | ID: mdl-34883607

ABSTRACT

In this study, two types of single polymer films have been inserted in a composite laminate to examine their toughening effects on mechanical properties. The first is a thermoplastic polyurethane (PU) film, and the second is an adhesive epoxy film featuring a polyester net. The laminates were manufactured either using a co-curing (CC) process or a secondary bonding (SB) process used for the epoxy film. Mode I and mode II interlaminar fracture toughness were measured for laminates manufactured by both processes and compared with the corresponding reference laminate toughness. A significant increase in both mode I and mode II toughness resulted when introducing a single PU film, approximately 290% and 50%, respectively. Similarly, the epoxy film improved the interlaminar fracture properties; the CC process produced an increase of 175% for mode II toughness, while the SB adhesive film showed an increase of 75% for mode II toughness.

3.
J Biomed Mater Res B Appl Biomater ; 108(7): 2835-2846, 2020 10.
Article in English | MEDLINE | ID: mdl-32277599

ABSTRACT

This article describes the use of a novel lactone-layered double hydroxide polymer network (PN), derived from a poly(lactide-co-caprolactone) copolymer, as a controlled ion-release agent for artificial bone tissue regeneration. The osteogenic cell culture Saos-2 is used as a test culture to investigate the PN's performance as an extracellular ion-release agent. The compelling performance of this PN is demonstrated in both growth and osteogenic media compared with a control of cells grown on tissue culture plastic (TCP) without PN. Firstly, the PNs released concentration of magnesium ions over time ranging from 10 to 60 mM after 24 hr, depending on the PN sample. After incubation of Saos-2 with the PN, while no difference was seen in cell number, there was significant upregulation of bone-related gene expression at 14 days-~5fold increase in Bone Morphogenetic Protein 2, ~3fold increase in osteopontin and ~2fold increase in collagen Type I. In addition, normalized alkaline phosphatase activity was seen to significantly increase by ~2fold with PN presence. A ~4fold increase in collagen Type I protein expression (via Gomori Trichrome Stain) was observed with PN presence. In addition, a ~4fold increase in phosphate deposits (as seen with Von Kossa staining analysis) was seen with PN presence. It is found that this novel PN material has a significant potential for bone tissue regeneration.


Subject(s)
Bone Regeneration , Cell Differentiation , Lactones/chemistry , Osteogenesis/drug effects , Tissue Engineering , Tissue Scaffolds/chemistry , Cell Line, Tumor , Humans , Powders
4.
3D Print Med ; 4(1): 2, 2018.
Article in English | MEDLINE | ID: mdl-29782613

ABSTRACT

BACKGROUND: There is a potential for direct model manufacturing of abdominal aortic aneurysm (AAA) using 3D printing technique for generating flexible semi-transparent prototypes. A patient-specific AAA model was manufactured using fused deposition modelling (FDM) 3D printing technology. A flexible, semi-transparent thermoplastic polyurethane (TPU), called Cheetah Water (produced by Ninjatek, USA), was used as the flexible, transparent material for model manufacture with a hydrophilic support structure 3D printed with polyvinyl alcohol (PVA). Printing parameters were investigated to evaluate their effect on 3D-printing precision and transparency of the final model. ISO standard tear resistance tests were carried out on Ninjatek Cheetah specimens for a comparison of tear strength with silicone rubbers. RESULTS: It was found that an increase in printing speed decreased printing accuracy, whilst using an infill percentage of 100% and printing nozzle temperature of 255 °C produced the most transparent results. The model had fair transparency, allowing external inspection of model inserts such as stent grafts, and good flexibility with an overall discrepancy between CAD and physical model average wall thicknesses of 0.05 mm (2.5% thicker than the CAD model). The tear resistance test found Ninjatek Cheetah TPU to have an average tear resistance of 83 kN/m, higher than any of the silicone rubbers used in previous AAA model manufacture. The model had lower cost (4.50 GBP per model), shorter manufacturing time (25 h 3 min) and an acceptable level of accuracy (2.61% error) compared to other methods. CONCLUSIONS: It was concluded that the model would be of use in endovascular aneurysm repair planning and education, particularly for practicing placement of hooked or barbed stents, due to the model's balance of flexibility, transparency, robustness and cost-effectiveness.

5.
ACS Nano ; 5(4): 3391-9, 2011 Apr 26.
Article in English | MEDLINE | ID: mdl-21410222

ABSTRACT

The morphological characterization of polymer nanocomposites over multiple length scales is a fundamental challenge. Here, we report a technique for high-throughput monitoring of interface and dispersion in polymer nanocomposites based on Förster resonance energy transfer (FRET). Nanofibrillated cellulose (NFC), fluorescently labeled with 5-(4,6-dichlorotriazinyl)-aminofluorescein (FL) and dispersed into polyethylene (PE) doped with Coumarin 30 (C30), is used as a model system to assess the ability of FRET to evaluate the effect of processing on NFC dispersion in PE. The level of energy transfer and its standard deviation, measured by fluorescence spectroscopy and laser scanning confocal microscopy (LSCM), are exploited to monitor the extent of interface formation and composite homogeneity, respectively. FRET algorithms are used to generate color-coded images for a real-space observation of energy transfer efficiency. These images reveal interface formation at a nanoscale while probing a macroscale area that is large enough to be representative of the entire sample. The unique ability of this technique to simultaneously provide orientation/spatial information at a macroscale and nanoscale features, encoded in the FRET signal, provides a new powerful tool for structure-property-processing investigation in polymer nanocomposites.