Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J AOAC Int ; 99(4): 878-889, 2016 Jul.
Article in English | MEDLINE | ID: mdl-27455929

ABSTRACT

The main known groups of mycotoxins are aflatoxins, fumonisins, ochratoxins, type A trichothecenes (T-2 toxin and HT-2 toxin), type B trichothecenes (deoxynivalenol), and zearalenones. They are harmful to humans, domestic animals, and livestock. In Europe, maximum permitted limits for aflatoxin B1 are set, and guidance levels are recommended for the other mycotoxins. This study applied biochip array technology to semiquantitative multimycotoxin screening at different levels to facilitate the verification of the compliance of feed material with acceptable safety standards. This application was developed and validated based on European Commission Decision No. 2002/657/EC. After a single generic sample-preparation method, simultaneous competitive chemiluminescent immunoassays were used and applied to the Evidence Investigator analyzer. The r and within-laboratory R values showed low overall CVs (10.6 and 11.6%, respectively). Low matrix effect and, consequently, low decision limits and detection capabilities proved the high sensitivity of the technology. The overall average recovery was 104%. Samples (n = 16) investigated within the Food Analysis Performance Assessment Scheme (FAPAS) program showed excellent correlation to assigned values. FAPAS proficiency-testing feed samples (n = 10) were within the schemes' z-score ±2 range. The authentic feed samples survey showed excellent correlation with LC-MS/MS. This application is, therefore, reliable and represents an innovative, cost-effective, and multianalytical tool for mycotoxin screening.


Subject(s)
Microarray Analysis/methods , Mycotoxins/analysis , Animal Feed/analysis , Food Contamination/analysis , Immunoassay/methods , Reproducibility of Results
2.
Am J Emerg Med ; 30(2): 267-74, 2012 Feb.
Article in English | MEDLINE | ID: mdl-21208763

ABSTRACT

OBJECTIVE: The aim of this study was to evaluate the diagnostic efficacy of multiple tests-heart-type fatty acid-binding protein (H-FABP), cardiac troponin I (cTnI), creatine kinase-MB, and myoglobin-for the early detection of acute myocardial infarction among patients who present to the emergency department with chest pain. METHODS: A total of 1128 patients provided a total of 2924 venous blood samples. Patients with chest pain were nonselected and treated according to hospital guidelines. Additional cardiac biomarkers were assayed simultaneously at serial time points using the Cardiac Array (Randox Laboratories Ltd, Crumlin, United Kingdom). RESULTS: Heart-type fatty acid-binding protein had the greatest sensitivity at 0 to 3 hours (64.3%) and 3 to 6 hours (85.3%) after chest pain onset. The combination of cTnI measurement with H-FABP increased sensitivity to 71.4% at 3 to 6 hours and 88.2% at 3 to 6 hours. Receiver operating characteristic curves demonstrated that H-FABP had the greatest diagnostic ability with area under the curve at 0 to 3 hours of 0.841 and 3 to 6 hours of 0.894. The specificity was also high for the combination of H-FABP with cTnI at these time points. Heart-type fatty acid-binding protein had the highest negative predictive values of all the individual markers: 0 to 3 hours (93%) and 3 to 6 hours (97%). Again, the combined measurement of cTnI with H-FABP increased the negative predictive values to 94% at 0 to 3 hours, 98% at 3 to 6 hours, and 99% at 6 to 12 hours. CONCLUSION: Testing both H-FABP and cTnI using the Cardiac Array proved to be both a reliable diagnostic tool for the early diagnosis of myocardial infarction/acute coronary syndrome and also a valuable rule-out test for patients presenting at 3 to 6 hours after chest pain onset.


Subject(s)
Fatty Acid-Binding Proteins/blood , Myocardial Infarction/diagnosis , Aged , Chest Pain/diagnosis , Chest Pain/etiology , Creatine Kinase, MB Form/blood , Emergency Service, Hospital , Fatty Acid Binding Protein 3 , Female , Humans , Male , Middle Aged , Myocardial Infarction/blood , Myoglobin/blood , Protein Array Analysis , ROC Curve , Sensitivity and Specificity , Time Factors , Troponin I/blood
3.
J Proteome Res ; 7(1): 450-5, 2008 Jan.
Article in English | MEDLINE | ID: mdl-18020322

ABSTRACT

Biochip array technology allows the simultaneous measurement of multiple analytes per sample using a single analytical device. This study shows its applicability to the simultaneous measurement of 12 circulating human cytokines with high-sensitivity detection. This application increases their real-time detectability, maintaining a broad concentration range and without compromising the precision. This methodology represents a very applicable tool in cytokine research when simultaneous determination of minute concentrations can be of interest.


Subject(s)
Cytokines/blood , Microarray Analysis/methods , Calibration , Humans , Microarray Analysis/standards , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...