Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Healthcare (Basel) ; 11(13)2023 Jun 27.
Article in English | MEDLINE | ID: mdl-37444698

ABSTRACT

BACKGROUND: Implementation of an anesthesiology-led cardiac implantable electronic device (CIED) service can be viewed to have economic and efficiency challenges. This study evaluates the cost savings of an anesthesiology-led CIED service. METHODS: A total of 830 patients presented in the pre-implementation period from 1 March 2016 to 31 December 2017, and 1981 patients presented in the post-implementation period from 1 January 2018 to 31 October 2021. Interrupted time-series analysis for single-group comparisons was used to evaluate the cost savings resulting from reduction in operating room (OR) start delays for patients with CIEDs. RESULTS: OR start-time delay was reduced by 10.6 min (95%CI: -20.5 to -0.83), comparing pre- to post-implementation. For an OR cost of USD 45/min, we estimated the direct cost to the department to be USD 1.68/min. The intervention translated into a total cost reduction during the intervention period of USD 250,000 (USD 18,000 to USD 470,000) per year for the institution and USD 9800 (USD 730 to USD 17,000) per year for the department. The yearly cost of employing a full-time team of CIED specialists would have been USD 135,456. The service triggered electrophysiology consultation on 13 device malfunctions. CONCLUSIONS: An anesthesiology-led CIED service resulted in substantial cost savings, increased OR efficiency and patient safety.

3.
Europace ; 21(4): 655-661, 2019 Apr 01.
Article in English | MEDLINE | ID: mdl-30815690

ABSTRACT

AIMS: The objective of this study was to verify acute safety, performance, and usage of a novel ultra-high density mapping system in patients undergoing ablation procedure in a real-world clinical setting. METHODS AND RESULTS: The TRUE HD study enrolled patients undergoing catheter ablation with mapping for all arrhythmias (excluding de novo atrial fibrillation) who were followed for 1 month. Safety was determined by collecting all serious adverse events and adverse events associated with the study devices. Performance was determined as the composite of: ability to map the arrhythmia/substrate, complete the ablation applications, arrhythmia termination (where applicable), and ablation validation. Use of mapping system in the ablation validation workflow was also evaluated. Among the 519 patients who underwent a complete (504) or attempted (15) procedure, 21 (4%) serious ablation-related complications were collected, with 3 (0.57%) potentially related to the mapping catheter. Four hundred and twenty treated patients resulted in a successful procedure confirmed by arrhythmia-specific validation techniques (83.3%; 95% confidence interval: 79.8-86.5%). A total of 1419 electroanatomical maps were created with a median acquisition time of 9:23 min per map. Of these, 372 maps in 222 (44%) patients were collected for ablation validation purposes. Following validation mapping, 162/222 (73%) patients required additional ablation. CONCLUSION: In the TRUE HD study mapping was associated with rates of acute success and complications consistent with previously published reports. Importantly, a low percentage of events (0.57%) was attributed to the mapping catheter. When performed, validation mapping was useful for identifying additional targets for ablation in the majority of patients.


Subject(s)
Arrhythmias, Cardiac/surgery , Catheter Ablation/methods , Electrophysiologic Techniques, Cardiac/instrumentation , Adult , Aged , Arrhythmias, Cardiac/physiopathology , Cardiac Tamponade/epidemiology , Electrophysiologic Techniques, Cardiac/methods , Female , Heart Injuries/epidemiology , Hematoma/epidemiology , Humans , Intraoperative Complications/epidemiology , Male , Middle Aged , Postoperative Complications/epidemiology , Prospective Studies , Prosthesis Failure , Treatment Outcome , Workflow
4.
Am J Cardiol ; 120(3): 404-407, 2017 Aug 01.
Article in English | MEDLINE | ID: mdl-28595862

ABSTRACT

Thromboembolic cerebrovascular accident remains a rare but potentially devastating complication of catheter-based atrial fibrillation (AF) ablation. Uninterrupted oral anticoagulant therapy with warfarin has become the standard of care when performing catheter-based AF ablation. Compared with warfarin, apixaban, a factor Xa inhibitor, has been shown to reduce the risk of stroke and major bleeding in nonvalvular AF. With an increase in apixaban use for stroke prophylaxis in patients with AF, there is an increased interest in the safety and efficacy of uninterrupted apixaban therapy during AF ablation. We compared the safety and efficacy of uninterrupted OA therapy with either warfarin or apixaban in all patients who underwent catheter-based AF ablation at the University of Alabama at Birmingham and at Augusta University Medical Center from January 7, 2013, to February 25, 2016. All patients underwent a transesophageal echocardiogram on the day of their ablation to assess for the presence of intracardiac thrombi. All complications were identified and classified as bleeding, thromboembolic events, or other. A total of 627 patients were analyzed as described earlier. There were 310 patients in the warfarin group and 317 patients in the apixaban group. There were 8 complications in the warfarin group and 5 complications in the apixaban group (p = 0.38). There were no thromboembolic complications in either group. In conclusion, the use of apixaban is as safe and effective as warfarin for uninterrupted OA therapy during catheter-based ablation of AF.


Subject(s)
Atrial Fibrillation/therapy , Catheter Ablation/methods , Pyrazoles/administration & dosage , Pyridones/administration & dosage , Stroke/prevention & control , Warfarin/administration & dosage , Aged , Anticoagulants/administration & dosage , Atrial Fibrillation/complications , Dose-Response Relationship, Drug , Factor Xa Inhibitors/administration & dosage , Female , Follow-Up Studies , Humans , Intraoperative Period , Male , Middle Aged , Retrospective Studies , Stroke/etiology , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...