Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Diving Hyperb Med ; 53(3): 172-180, 2023 Sep 30.
Article in English | MEDLINE | ID: mdl-37718290

ABSTRACT

Introduction: Chest compression often cannot be administered using conventional techniques in a diving bell. Multiple alternative techniques are taught, including head-to-chest and both prone and seated knee-to-chest compressions, but there are no supporting efficacy data. This study evaluated the efficacy, safety and sustainability of these techniques. Methods: Chest compressions were delivered by a team of expert cardiopulmonary resuscitation (CPR) providers. The primary outcome was proportion of chest compressions delivered to target depth compared to conventional CPR. Techniques found to be safe and potentially effective by the study team were further trialled by 20 emergency department staff members. Results: Expert providers delivered a median of 98% (interquartile range [IQR] 1.5%) of chest compressions to the target depth using conventional CPR. Only 32% (IQR 60.8%) of head-to-chest compressions were delivered to depth; evaluation of the technique was abandoned due to adverse effects. No study team member could register sustained compression outputs using prone knee-to-chest compressions. Seated knee-to-chest were delivered to depth 12% (IQR 49%) of the time; some compression providers delivered > 90% of compressions to depth. Conclusions: Head-to-chest compressions have limited efficacy and cause harm to providers; they should not be taught or used. Prone knee-to-chest compressions are ineffective. Seated knee-to-chest compressions have poor overall efficacy but some providers deliver them well. Further research is required to establish whether this technique is feasible, effective and sustainable in a diving bell setting, and whether it can be taught and improved with practise.


Subject(s)
Cardiopulmonary Resuscitation , Diving , Humans
2.
Diving Hyperb Med ; 53(3): 181-188, 2023 Sep 30.
Article in English | MEDLINE | ID: mdl-37718291

ABSTRACT

Introduction: Provision of manual chest compressions in a diving bell using a conventional technique is often impossible, and alternative techniques are poorly evidenced in terms of efficacy and sustainability. The first mechanical cardiopulmonary resuscitation (CPR) device suitable for use in this environment, the NUI Compact Chest Compression Device (NCCD), has recently been designed and manufactured. This study assessed both the efficacy of the device in delivering chest compressions to both prone and seated manikins, and the ability of novice users to apply and operate it. Methods: Compression efficacy was assessed using a Resusi Anne QCPR intelligent manikin, and the primary outcome was the proportion of compressions delivered to target depth (50-60 mm). The gold standard was that achieved by expert CPR providers delivering manual CPR; the LUCAS 3 mCPR device was a further comparator. Results: The NCCD delivered 100% of compressions to target depth compared to 98% for the gold standard (interquartile range 1.5%) and 98% for the LUCAS 3 when applied to both supine and seated manikins. The NCCD sometimes became dislodged and had to be reapplied when used with a seated manikin. Conclusions: The NCCD can deliver chest compressions at target rate and depth to both supine and seated manikins with efficacy equivalent to manual CPR and the LUCAS 3. It can become dislodged when applied to a seated manikin; its design has now been altered to prevent this. New users can be trained in use of the NCCD quickly, but practise is required to ensure effective use.


Subject(s)
Cardiopulmonary Resuscitation , Diving , Humans
SELECTION OF CITATIONS
SEARCH DETAIL