1.
Anaesthesia ; 67(8): 875-80, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22519895

ABSTRACT

We present a randomised, controlled, crossover trial of the Caudwell Xtreme Everest (CXE) closed circuit breathing system vs an open circuit and ambient air control in six healthy, hypoxic volunteers at rest and exercise at Everest Base Camp, at 5300 m. Compared with control, arterial oxygen saturations were improved at rest with both circuits. There was no difference in the magnitude of this improvement as both circuits restored median (IQR [range]) saturation from 75%, (69.5-78.9 [68-80]%) to > 99.8% (p = 0.028). During exercise, the CXE closed circuit improved median (IQR [range]) saturation from a baseline of 70.8% (63.8-74.5 [57-76]%) to 98.8% (96.5-100 [95-100]%) vs the open circuit improvement to 87.5%, (84.1-88.6 [82-89]%; p = 0.028). These data demonstrate the inverse relationship between supply and demand with open circuits and suggest that ambulatory closed circuits may offer twin advantages of supplying higher inspired oxygen concentrations and/or economy of gas use for exercising hypoxic adults.


Subject(s)
Exercise , Mountaineering/physiology , Respiration , Adult , Altitude , Cross-Over Studies , Female , Heart Rate , Humans , Male , Middle Aged , Oxygen/blood
2.
Br J Anaesth ; 106(5): 706-12, 2011 May.
Article in English | MEDLINE | ID: mdl-21498494

ABSTRACT

BACKGROUND: Transversus abdominis plane (TAP) block is an alternative to spinal morphine for analgesia after Caesarean section but there are few data on its comparative efficacy. We compared the analgesic efficacy of the TAP block with and without spinal morphine after Caesarean section in a prospective, randomized, double-blinded placebo-controlled trial. METHODS: Eighty patients were randomized to one of four groups to receive (in addition to spinal anaesthesia) either spinal morphine 100 µg (S(M)) or saline (S(S)) and a postoperative bilateral TAP block with either bupivacaine (T(LA)) 2 mg kg(-1) or saline (T(S)). RESULTS: Pain on movement and early morphine consumption were lowest in groups receiving spinal morphine and was not improved by TAP block. The rank order of median pain scores on movement at 6 h was: S(M)T(LA) (20 mm)

Subject(s)
Analgesia, Obstetrical/methods , Analgesics, Opioid/administration & dosage , Cesarean Section , Morphine/administration & dosage , Nerve Block/methods , Pain, Postoperative/prevention & control , Abdominal Muscles , Adult , Analgesia, Obstetrical/adverse effects , Analgesics, Opioid/adverse effects , Anesthesia, Obstetrical/methods , Anesthesia, Spinal , Antiemetics/administration & dosage , Double-Blind Method , Drug Administration Schedule , Female , Humans , Morphine/adverse effects , Nerve Block/adverse effects , Pain Measurement/methods , Patient Satisfaction , Pregnancy , Prospective Studies , Pruritus/chemically induced
3.
Anaesthesia ; 66(5): 348-53, 2011 May.
Article in English | MEDLINE | ID: mdl-21443642

ABSTRACT

We describe a unique ambulatory closed circuit for delivering high fractions of inspired oxygen to an exercising user who does not require isolation from their environment. We describe the major components and their function and suggest potential applications for such a circuit. This circuit may benefit patients who are chronically dependant on oxygen, are unable to exercise due to hypoxia, or require oxygen supplementation at high altitude.


Subject(s)
Ambulatory Care/methods , Exercise/physiology , Hypoxia/therapy , Oxygen Inhalation Therapy/instrumentation , Equipment Design , Humans , Hypoxia/physiopathology , Masks , Oxygen Inhalation Therapy/methods
4.
Eur J Anaesthesiol ; 25(4): 293-8, 2008 Apr.
Article in English | MEDLINE | ID: mdl-18177539

ABSTRACT

BACKGROUND AND OBJECTIVE: Massive post-partum haemorrhage continues to be one of the world's leading causes of maternal morbidity and mortality. Any new treatment that potentially helps at risk parturients should be thoroughly investigated. Recombinant factor VIIa (rVIIa) is increasingly being used in the treatment of massive haemorrhage. We performed a case-matched analysis of its use since 2003 in the treatment of massive post-partum haemorrhage at our hospital. METHODS: Twenty-eight cases of massive post-partum haemorrhage were identified over a 3-yr period since 2003. In six of these cases, rVIIa was used as part of their management. Six case-matched controls were sought. The six women with the greatest requirement for packed red cell transfusion who also had a deranged prothrombin time were included. The groups were then compared for differences. The worst prothrombin time in each group was noted as was the best prothrombin time within 6 h, this was used as our measure of response to treatment. RESULTS: There was no statistical difference in age, gestation, parity, transfusion requirements, mode of delivery or the severity of the coagulopathy between the two groups. In both groups the prothrombin time improved with management. There was no significant difference in either the magnitude of the improvement in the value of the prothrombin time or the absolute value of the best prothrombin time (P = 0.09). Five out of the six women in the rFVIIa group had normal or low prothrombin times within 6 h yet only one woman who did not receive rFVIIa had a normal prothrombin time within 6 h though this was not significant (P = 0.08). CONCLUSIONS: This case-matched analysis supports the management of massive post-partum haemorrhage with appropriate resuscitation, surgical intervention and use of blood and blood products. This study does not support the routine use of rFVIIa in the management of massive obstetric haemorrhage. rFVIIa may have a role to play in this management but further studies and analyses will be required.


Subject(s)
Erythrocyte Transfusion , Factor VIIa/therapeutic use , Postpartum Hemorrhage/drug therapy , Prothrombin Time , Adult , Blood Transfusion , Case-Control Studies , Female , Humans , Pregnancy , Recombinant Proteins/therapeutic use , Retrospective Studies , Time Factors , Treatment Outcome
5.
Anaesthesia ; 58(10): 998-1002, 2003 Oct.
Article in English | MEDLINE | ID: mdl-12969041

ABSTRACT

A new laryngoscope has been designed, incorporating an adjustable mirror and a levered tip similar to the McCoy blade, in an attempt to bridge the gulf between simple direct laryngoscopy and fiberoptic laryngoscopy. Manual in-line neck stabilisation was used to simulate difficult laryngoscopy in 14 anaesthetised patients after full neuromuscular blockade. The best view at laryngoscopy was assessed using a standard Macintosh laryngsocope, a size 3 McCoy laryngoscope and the mirrored laryngoscope. The best laryngeal view obtained in all cases with the Macintosh blade was a grade 3. The mirrored laryngoscope improved this view in 10 cases (71%) compared with five cases (36%) with the McCoy laryngoscope (p = 0.005); in seven cases (50%), the view improved to a grade 1 compared with no cases when the McCoy was used (p = 0.02). We conclude that the mirrored laryngoscope offers considerable advantages over the Macintosh and the McCoy laryngoscopes in simulated difficult laryngoscopy, is simple to use and requires no special training.


Subject(s)
Laryngoscopes , Anesthesia, General , Equipment Design , Humans , Intubation, Intratracheal , Laryngoscopy/methods
6.
Thorax ; 57(5): 400-4, 2002 May.
Article in English | MEDLINE | ID: mdl-11978915

ABSTRACT

BACKGROUND: Normal subjects frequently experience troublesome respiratory symptoms when acclimatised to altitude. Bronchial hyperresponsiveness (BHR) and full and partial flow-volume loops were measured before and after ascent to 5000 m altitude to determine if there are changes in resting bronchial tone and BHR that might explain the symptoms. METHODS: BHR to histamine was measured using a turbine spirometer to record partial and full flow-volume curves and expressed as log dose slopes. Twenty one subjects were tested at sea level and after acclimatisation at 5000 m altitude. RESULTS: No significant change in log dose slope measurements of forced expiratory volume in 1 second occurred after acclimatisation, and the maximal expiratory flow with 30% of forced vital capacity remaining (MEF(30%)) rose on the full loop and fell on the partial loop. Their ratio (full divided by partial) rose on average by 0.28 (95% confidence limits 0.14 to 0.42) from the mean (SD) sea level value of 0.87 (0.20). CONCLUSIONS: There is no increase in BHR in normal subjects acclimatised to altitude but an increase in resting bronchial tone occurs that could be released by deep inspiration. This may be the result of increased cholinergic tone.


Subject(s)
Adaptation, Physiological/physiology , Altitude , Bronchi/physiology , Bronchial Hyperreactivity/physiopathology , Adult , Bronchial Hyperreactivity/diagnosis , Bronchial Provocation Tests , Female , Forced Expiratory Volume/physiology , Histamine , Humans , Male , Peak Expiratory Flow Rate/physiology , Vital Capacity/physiology
SELECTION OF CITATIONS
SEARCH DETAIL
...