1.
Struct Heart ; 8(3): 100277, 2024 May.
Article in English | MEDLINE | ID: mdl-38799801

ABSTRACT

Inferior outcomes with ACURATE neo, a self-expanding transcatheter heart valve (THV) for the treatment of severe aortic stenosis, were mainly driven by higher rates of moderate/severe paravalvular leak (PVL). To overcome this limitation, the next-generation ACURATE neo2 features a 60% larger external sealing skirt. Data on long-term performance are limited; however, clinical evidence suggests improved short-term performance which is comparable to contemporary THVs. This report reviews data on short-term clinical and echocardiographic outcomes of ACURATE neo2. A PubMed search yielded 13 studies, including 5 single arm and 8 nonrandomized comparative studies with other THVs which reported in-hospital or 30-day clinical and echocardiographic outcomes. In-hospital or 30-day all-cause mortality was ≤3.3%, which is comparable to other contemporary THVs. The rates of postprocedural ≧moderate PVL ranged 0.6%-4.7%. In multicenter propensity-matched analyses, neo2 significantly reduced the rate of ≧moderate PVL compared to neo (3.5% vs. 11.3%, p < 0.01), whereas rates were comparable to Evolut Pro/Pro+ (Neo2: 2.0% vs. Pro/Pro+: 3.1%, p = 0.28) and SAPIEN 3 Ultra (Neo2: 0.6% vs. Ultra: 1.1%, p = 0.72). The rate of permanent pacemaker implantation with neo2 was consistently low (3.3%-8.6%) except in one study, and in propensity-matched analyses were significantly lower than Evolut Pro/Pro+ (6.7% vs. 16.7%, p < 0.01), and comparable to SAPIEN 3 Ultra (8.1% vs. 10.3%, p = 0.29). In conclusion, ACURATE neo2 showed better short-term performance by considerably reducing PVL compared to its predecessor, with short-term clinical and echocardiographic outcomes comparable to contemporary THVs.

2.
JACC Case Rep ; 29(3): 102192, 2024 Feb 07.
Article in English | MEDLINE | ID: mdl-38361571

ABSTRACT

Misloading during transcatheter aortic valve replacement (TAVR) is rare but can cause unpredictable valve release if unrecognized. We describe how to identify a misloaded ACURATE neo2 device, and 3 methods to solve this by using a modified technique of valve deployment, ipsilateral extraction, and contralateral valve externalization with extracorporeal valve release.

3.
Int J Cardiol ; 400: 131792, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38244892

ABSTRACT

BACKGROUND: ACURATE neo2 (Neo2) implantation is performed after systematic Balloon Aortic Valvuloplasty (BAV) in most patients. No reports exist about the feasibility and safety of direct Neo2 transcatheter aortic valve implantation (TAVI) in comparison to the standard practice. AIM: We aimed to identify the patients' baseline anatomical characteristics, procedural, and early post-procedural outcomes in patients treated using Neo2 with and without BAV. METHODOLOGY: This is a retrospective multicentre analysis of 499 patients with severe aortic stenosis who underwent TAVI using Neo2. The comparison was done according to the performance or omission of BAV. Echocardiography and computed tomography were analysed by an independent Core Lab. Propensity score matching (PSM) was performed based on the annular diameter and AV calcium volume, which identified 84 matched pairs. RESULTS: Among the cohort included, 391 (78%) patients received BAV (BAV-yes) and 108 (22%) were not attempted (BAV-no or Direct TAVI). Patients in BAV-no cohort had smaller annular diameter (22.6 vs 23.4 mm; p < 0.001) and lower calcium volume (163 vs 581 mm3; p < 0.001) compared to BAV-yes cohort. In the matched cohort, VARC-3 device technical success was similar (95%) and all other outcome measures were statistically comparable between cohorts. CONCLUSION: Direct TAVI using ACURATEneo2 without pre-TAVI balloon aortic valvuloplasty in patients with mild or less valve calcifications might be feasible and associated with comparable early outcomes compared to patients with similar anatomical features undergoing systematic balloon valvuloplasty.


Subject(s)
Aortic Valve Stenosis , Balloon Valvuloplasty , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Balloon Valvuloplasty/methods , Calcium , Treatment Outcome , Retrospective Studies , Prosthesis Design
4.
J Am Heart Assoc ; 12(15): e029464, 2023 08.
Article in English | MEDLINE | ID: mdl-37489732

ABSTRACT

Background ACURATE neo2 is a transcatheter aortic valve implantation system consisting of a self-expanding bioprosthetic valve with supra-annular leaflet position and featuring innovations to facilitate placement accuracy and reduce paravalvular regurgitation. Methods and Results The goal of the Early neo2 (Early neo2 Registry of the ACURATE neo2 TAVI Prosthesis) was to gather real-life data on safety and efficacy in a European transcatheter aortic valve implantation population treated with ACURATE neo2. Data were collected from 554 consecutive patients treated with ACURATE neo2 at 12 European sites (mean age, 82 years; 66% women; mean European System for Cardiac Operative Risk Evaluation II, 4.5%±3.8%) between September 2020 and March 2021. The composite primary end point was the occurrence of any of the following: postoperative (in-hospital) paravalvular regurgitation grade ≥2, in-hospital acute kidney injury stage 3, postoperative pacemaker implantation, 30-day death, and 30-day stroke. The primary end point occurred in 12.6% of patients. The 30-day rates for all-cause death and all stroke were 1.3% and 2.7%, respectively, and 1.5% of patients exhibited stage 3 acute kidney injury. A total of 34 patients (6.2%) received a postoperative permanent pacemaker. Per core laboratory-adjudicated echocardiographic analysis, mean postoperative aortic valve gradient was 7.6±3.3 mm Hg, and 2.8% of patients exhibited paravalvular regurgitation grade ≥2. Conclusions In this report of postmarket use of the ACURATE neo2 valve in a real-world transcatheter aortic valve implantation population, patients exhibited favorable postoperative hemodynamics and clinical outcomes and a low rate of postoperative pacemaker implantation.


Subject(s)
Acute Kidney Injury , Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Humans , Female , Aged, 80 and over , Male , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Prosthesis Design , Treatment Outcome , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Registries , Stroke/epidemiology
5.
EuroIntervention ; 19(4): e352-e362, 2023 Jul 17.
Article in English | MEDLINE | ID: mdl-37334801

ABSTRACT

BACKGROUND: TAVI is a widely accepted treatment for patients with severe aortic stenosis (AS). Despite the adoption of diverse therapies, opportunities remain to develop technologies tailored to provide optimal acute and potential long-term benefits, particularly around haemodynamics, flow and durability. AIMS: We aimed to evaluate the safety and feasibility of the DurAVR transcatheter heart valve (THV), a first-in-class biomimetic valve, in the treatment of patients with symptomatic severe AS. METHODS: This was a first-in-human (FIH), prospective, non-randomised, single-arm, single-centre study. Patients with severe, symptomatic AS of any surgical risk and who were eligible for the DurAVR THV prosthesis were recruited; they were assessed at baseline, 30 days, 6 months, and 1 year post-procedure for implant success, haemodynamic performance, and safety. RESULTS: Thirteen patients (73.9±6.4 years old, 77% female) were enrolled. The DurAVR THV was successfully implanted in 100% of cases with no device-related complications. One access site complication, one permanent pacemaker implantation, and one case of moderate aortic regurgitation occurred. Otherwise, no deaths, stroke, bleeding, reinterventions, or myocardial infarction were reported during any of the follow-up visits. Despite a mean annulus size of 22.95±1.09 mm, favourable haemodynamic results were observed at 30 days (effective orifice area [EOA] 2.00±0.17 cm2, and mean pressure gradient [MPG] 9.02±2.68 mmHg) and were sustained at 1 year (EOA 1.96±0.11 cm2, MPG 8.82±1.38 mmHg), resulting in zero patients with any degree of prosthesis-patient mismatch. Additionally, new valve performance measures derived from cardiovascular magnetic resonance displayed restoration of laminar flow, consistent with a predisease state, in conjunction with a mean coaptation length of 8.3±1.7 mm. CONCLUSIONS: Preliminary results from the FIH study with DurAVR THV demonstrate a good safety profile with promising haemodynamic performance sustained at 1 year and restoration of near-normal flow dynamics. Further clinical investigation is warranted to evaluate how DurAVR THV may play a role in addressing the challenge of lifetime management in AS patients.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , Aged, 80 and over , Male , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/surgery , Prospective Studies , Feasibility Studies , Biomimetics , Treatment Outcome , Prosthesis Design
6.
JACC Heart Fail ; 11(8 Pt 2): 1121-1130, 2023 08.
Article in English | MEDLINE | ID: mdl-37115132

ABSTRACT

BACKGROUND: Most approaches to the creation of an interatrial shunt require placement of a permanent implant to maintain patency. OBJECTIVES: The goal of this study was to investigate the safety and efficacy of a no-implant interatrial shunt for patients with heart failure with preserved ejection fraction (HFpEF) and heart failure with mildly reduced ejection fraction (HFmrEF). METHODS: This was a multicenter, uncontrolled study of patients with HFpEF/HFmrEF and NYHA functional class ≥II, ejection fraction >40%, and pulmonary capillary wedge pressure (PCWP) during supine exercise ≥25 mm Hg with PCWP-to-right atrial gradient ≥5 mm Hg. Follow-up was through 6 months with imaging to assess shunt durability. RESULTS: A total of 28 patients were enrolled: mean age was 68 ± 9 years, and 68% were female. Baseline resting and peak exercise PCWP were 19 ± 7 mm Hg and 40 ± 11 mm Hg, respectively. All procedures displayed technical success with confirmation of left-to-right flow (shunt diameter 7.1 ± 0.9 mm). At 1 month, peak exercise PCWP decreased 5.4 ± 9.6 mm Hg (P = 0.011) with no change in right atrial pressure. There were no serious device or procedure-related adverse events through 6 months. Mean 6-minute walk distance increased 101 ± 71 meters (P < 0.001); Kansas City Cardiomyopathy Questionnaire Overall Summary Score increased 26 ± 19 points (P < 0.001); N-terminal pro-B-type natriuretic peptide decreased 372 ± 857 pg/mL (P = 0.018); and shunt patency was confirmed with unchanged diameter. CONCLUSIONS: In these feasibility studies of a no-implant interatrial shunt, HFpEF/HFmrEF shunts exhibited stability with favorable safety and early efficacy signals. The results show promise toward this new approach for treating patients with HFpEF/HFmrEF and an appropriate hemodynamic profile. (Evaluation of the Safety and Feasibility of a Percutaneously Created Interatrial Shunt to Alleviate Heart Failure Symptoms in Patients With Chronic Heart Failure and Preserved or Mid-Range Left Ventricular Ejection Fraction [ALLEVIATE-HF-1]; NCT04583527; Evaluation of the Safety and Effectiveness of a Percutaneously Created Interatrial Shunt to Alleviate Heart Failure Symptoms in Patients With Chronic Heart Failure and Preserved or Mid-Range Left Ventricular Ejection Fraction [ALLEVIATE-HF-2]; NCT04838353).


Subject(s)
Heart Failure , Ventricular Dysfunction, Left , Humans , Female , Middle Aged , Aged , Male , Stroke Volume , Ventricular Function, Left , Feasibility Studies , Cardiac Catheterization , Ventricular Dysfunction, Left/etiology
7.
JACC Cardiovasc Interv ; 16(6): 670-677, 2023 03 27.
Article in English | MEDLINE | ID: mdl-36990556

ABSTRACT

BACKGROUND: Commissural alignment has become an important topic in transcatheter aortic valve replacement (TAVR) because it may improve coronary access, facilitate future valve procedures, and possibly improve valve durability. The efficacy of commissural alignment with ACURATE neo2 has not yet been shown in a large population. OBJECTIVES: The authors sought to determine the feasibility and success of attempting commissural alignment in an unselected TAVR population treated with the ACURATE neo2 prosthetic heart valve. METHODS: A total of 170 consecutive patients underwent TAVR with a dedicated implantation technique to align the TAVR valve to the native valve. Using right-left overlap and 3-cusp views, valve orientation was adjusted by rotation of the unexpanded valve at the level of the aortic root. Effectiveness was assessed postprocedure as the degree of misalignment determined by analyzing fluoroscopic valve orientation to corresponding cusp orientation on preprocedural computed tomography. Safety endpoints included mortality, stroke/transient ischemic attack, and additional complications through 30 days. RESULTS: Of 170 patients, 167 (98.2%) could be analyzed for alignment, and all 170, for safety outcomes. Most patients (97%) had successful alignment (≤ mild misalignment), with 80% with commissural alignment, while the degrees of misalignment were 17% mild, 1.2% moderate, 1.8% severe. CONCLUSIONS: In this large evaluation of a commissural alignment technique, alignment was achieved in nearly all patients without safety concerns or impact to procedure duration. Commissural alignment appears effective and safe across all patients with this novel technique.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/etiology , Risk Factors , Prosthesis Design , Treatment Outcome , Transcatheter Aortic Valve Replacement/adverse effects , Multidetector Computed Tomography
8.
Int J Cardiol ; 377: 26-32, 2023 04 15.
Article in English | MEDLINE | ID: mdl-36640966

ABSTRACT

BACKGROUND: Cardiac tamponade caused by temporary right ventricular (RV) pacemaker perforation is a rare but serious complication in transcatheter aortic valve replacement (TAVR). AIMS: To study the incidence of temporary pacemaker related cardiac tamponade in TAVR, and the relation to the type of pacemaker lead used in periprocedural temporary transvenous pacing. METHODS: A single center registry of transfemoral TAVRs in 2014-2020. Main inclusion criterion was peri-operative use of a temporary RV pacing lead. Main exclusion criteria were a preoperatively implanted permanent pacemaker or the exclusive use of left ventricular guidewire pacing. Incident cardiac tamponade was classified as pacemaker lead related, or other. Patients were grouped according to type of temporary RV pacing wire. RESULTS: 810 patients were included (age 80.5 ± 7.3 [mean ± standard deviation], female 319, 39.4%). Of these, 566 (69.9%) received a standard RV temporary pacing wire (RV-TPW), and 244 (30.1%) received temporary RV pacing through a permanent, passive pacemaker lead (RV-TPPL). In total, 18 (2.2%) events of cardiac tamponade occurred, 12 (67%) were pacemaker lead related. All pacemaker lead-related cardiac tamponades occurred in the group who received a standard RV-TPW and none in the group who received RV-TPPL (n = 12 [2.1%] vs. n = 0 [0%], p = 0.022). No difference in cardiac tamponade due to other causes was seen between the groups (p = 0.82). CONCLUSIONS: The use of soft-tip RV-TPPL was associated with a lower risk of pacemaker related cardiac tamponade in TAVR. When perioperative pacing is indicated, temporary RV-TPPL may contribute to a significant reduction of cardiac tamponade in TAVR.


Subject(s)
Aortic Valve Stenosis , Cardiac Tamponade , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Female , Aged , Aged, 80 and over , Transcatheter Aortic Valve Replacement/adverse effects , Cardiac Tamponade/diagnosis , Cardiac Tamponade/epidemiology , Cardiac Tamponade/etiology , Treatment Outcome , Pacemaker, Artificial/adverse effects , Cardiac Pacing, Artificial , Aortic Valve Stenosis/surgery , Risk Factors , Aortic Valve/surgery
9.
J Clin Med ; 11(20)2022 Oct 17.
Article in English | MEDLINE | ID: mdl-36294424

ABSTRACT

(1) Background: Hemodynamic assessment of prosthetic heart valves using conventional 2D transthoracic Echocardiography-Doppler (2D-TTE) has limitations. Of those, left ventricular outflow tract (LVOT) area measurement is one of the major limitations of the continuity equation, which assumes a circular LVOT. (2) Methods: This study comprised 258 patients with severe aortic stenosis (AS), who were treated with the ACURATE neo2. The LVOT area and its dependent Doppler-derived parameters, including effective orifice area (EOA) and stroke volume (SV), in addition to their indexed values, were calculated from post-TAVI 2D-TTE. In addition, the 3D-LVOT area from pre-procedural MDCT scans was obtained and used to calculate corrected Doppler-derived parameters. The incidence rates of prosthesis patient mismatch (PPM) were compared between the 2D-TTE and MDCT-based methods (3) Results: The main results show that the 2D-TTE measured LVOT is significantly smaller than 3D-MDCT (350.4 ± 62.04 mm2 vs. 405.22 ± 81.32 mm2) (95% Credible interval (CrI) of differences: -55.15, -36.09), which resulted in smaller EOA (2.25 ± 0.59 vs. 2.58 ± 0.63 cm2) (Beta = -0.642 (95%CrI of differences: -0.85, -0.43), and lower SV (73.88 ± 21.41 vs. 84.47 ± 22.66 mL), (Beta = -7.29 (95% CrI: -14.45, -0.14)), respectively. PPM incidence appears more frequent with 2D-TTE- than 3D-MDCT-corrected measurements (based on the EOAi) 8.52% vs. 2.32%, respectively. In addition, significant differences regarding the EOA among the three valve sizes (S, M and L) were seen only with the MDCT, but not on 2D-TTE. (4) Conclusions: The corrected continuity equation by combining the 3D-LVOT area from MDCT with the TTE Doppler parameters might provide a more accurate assessment of hemodynamic parameters and PPM diagnosis in patients treated with TAVI. The ACURATE neo2 THV has a large EOA and low incidence of PPM using the 3D-corrected LVOT area than on 2D-TTE. These findings need further confirmation on long-term follow-up and in other studies.

10.
J Invasive Cardiol ; 34(11): E776-E783, 2022 11.
Article in English | MEDLINE | ID: mdl-36227011

ABSTRACT

OBJECTIVES: We aimed to develop and validate an effective prediction model for 1-year mortality risk in elective transfemoral transcatheter aortic valve replacement (TAVR), ie, the TAVR-Risk (TARI) model. BACKGROUND: TAVR is the primary treatment for patients with symptomatic severe aortic valve stenosis; however, risk assessment tools for longer-term outcomes after TAVR remain scarce. METHODS: This retrospective cohort study used logistic regression to test univariate and multivariate associations. The German Aortic Valve Registry (GARY) was the derivation (n = 20,704) and the Swedish SWEDEHEART TAVR Registry (SWENTRY) was the validation cohort (n = 3982). The main outcome was the area under the curve (AUC) in the prediction of 1-year mortality. The final model included 12 parameters that were associated with 1-year mortality in a multivariate analysis. RESULTS: The TARI model (AUC, 0.66; 95% confidence interval [CI] 0.65-0.67) performed better as compared with the Society of Thoracic Surgeons (STS) score (AUC, 0.63; 95% CI, 0.62-0.64; P<.001) and logistic EuroSCORE I (AUC, 0.60; 95% CI, 0.59-0.61; P<.001) in the GARY derivation cohort, and discriminated the risk for 1-year mortality better than logistic EuroSCORE I in the SWENTRY validation cohort (AUC, 0.62; 95% CI, 0.60-0.64 vs AUC, 0.59; 95% CI, 0.57-0.61; P=.04). CONCLUSIONS: This novel TARI score provides a relatively easy-to-use risk model and offers a superior prediction for 1-year mortality in European TAVR patients.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/surgery , Retrospective Studies , Aortic Valve Stenosis/surgery , Risk Factors , Risk Assessment , Treatment Outcome
11.
Int J Cardiol ; 359: 7-13, 2022 07 15.
Article in English | MEDLINE | ID: mdl-35427700

ABSTRACT

BACKGROUND: Arterial access-site related complications constitute a large proportion of adverse events related to cardiac interventions requiring large-bore devices and have significant implications on morbidity, mortality and hospital cost. AIMS: To evaluate the safety and effectiveness of a novel percutaneous plug-based vascular closure device (VCD) in 1000 consecutive patients undergoing transfemoral transcatheter aortic valve implantation (TAVI). METHODS: A single-center observational study evaluating a plug-based VCD (MANTA, Teleflex/Essential Medical Inc., Malvern, Pennsylvania, USA) in patients undergoing TAVI at the Karolinska University Hospital, Stockholm, Sweden. The primary outcome was VCD-related major vascular complication according to the criteria of the Valve Academic Research Consortium (VARC)-2. RESULTS: From May 2017 to September 2020 a total of 1000 consecutive patients underwent transfemoral TAVI with arterial access-site management using the MANTA VCD. VARC-2 major vascular complications occurred in 42 (4.2%) patients: 17 (1.7%) patients intraoperatively received a covered stent, 17 (1.7%) patients underwent surgical repair during hospital stay, 3 (0.3%) patients underwent vascular surgery after discharge, 3 (0.3%) patients had major bleeding and 2 (0.2%) patients had symptoms of claudication with conservative treatment. No significant differences in major complications were seen between individual interventionists irrespective of experience with the device. A larger sheath outer diameter to femoral artery inner diameter ratio was the only factor associated with a significant increase of VCD-related major vascular complications. CONCLUSION: This largest ever real-world evaluation of MANTA for large-bore arteriotomy closure in transfemoral TAVI patients indicates effective and safe arterial access-site management with low complication rates and short learning curve. CLINICAL TRIAL REGISTRATION: http://www. CLINICALTRIALS: gov. Unique identifier: NCT04392492.


Subject(s)
Aortic Valve Stenosis , Catheterization, Peripheral , Transcatheter Aortic Valve Replacement , Vascular Closure Devices , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Catheterization, Peripheral/adverse effects , Femoral Artery/surgery , Hemostatic Techniques , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Vascular Closure Devices/adverse effects
14.
Am Heart J ; 245: 100-109, 2022 03.
Article in English | MEDLINE | ID: mdl-34932999

ABSTRACT

BACKGROUND: Tricuspid valve disease (TVD) is presumed common, however, little is known about its prevalence or the impact of tricuspid valve surgery (TVS) on healthcare resource use. METHODS: To describe the prevalence of TVD and assess the impact of TVS on resource utilization, Medicare Fee-For-Service beneficiaries from 2011 -2019 were assessed for the prevalence of non-rheumatic TVD. Hospital costs and rates of all-cause, cardiovascular (CV), and heart failure (HF) hospitalizations were compared in the 3 months pre TVS to acute (0-3 months) and chronic (3 -12 months) post TVS periods. RESULTS: Among 80.3 million beneficiaries from 2011 - 2019 Q1, over 700,000 (0.9%) had non-rheumatic TVD with 1.4% undergoing TVS. Thirty-day and 1 year mortality after TVS was 5.5% to15.5%. Compared with pre-surgery, CV and HF hospitalizations decreased from 0.12 to 0.08 per patient-month (P <.001), and 0.06 to 0.04 (P <.001) acutely. All-cause hospitalizations increased from 0.18 per patient-month to 0.23 per patient-month acutely post-surgery (P <.001), before decreasing to 0.09 per patient-month chronically (P <.001). Hospital costs increased from $2,174 per patient-month to $4,171 per patient-month acutely (P < .001), before falling to $1,441 per patient-month (P < .001) chronically. Lower costs for HF and CV hospitalization in both acute (P = .028 and P < .001, respectively) and chronic (P < .001 for both) periods were observed. CONCLUSIONS: TVS is associated with reduced CV and HF hospitalizations and associated hospital costs. Future work should determine whether transcatheter tricuspid valve repair offers similar or additional benefits.


Subject(s)
Heart Valve Diseases , Tricuspid Valve , Aged , Heart Valve Diseases/epidemiology , Heart Valve Diseases/surgery , Hospitals , Humans , Medicare , Prevalence , Retrospective Studies , Tricuspid Valve/surgery , United States/epidemiology
15.
Struct Heart ; 6(4): 100078, 2022 Aug.
Article in English | MEDLINE | ID: mdl-37288335

ABSTRACT

Background: Heart failure with preserved ejection fraction represents a major unmet clinical need with limited treatment options. Recent device therapies under investigation have focused on decompression of the left atrium through an implantable interatrial shunt. Although these devices have shown favorable safety and efficacy signals, an implant is required to maintain shunt patency, which may increase the patient risk profile and complicate subsequent interventions requiring transseptal access. Methods: The Alleviant System is a no-implant approach to creating an interatrial shunt using radiofrequency energy to securely capture, excise, and extract a precise disk of tissue from the interatrial septum. Acute preclinical studies in healthy swine (n = 5) demonstrated the feasibility of the Alleviant System to repeatably create a 7 mm interatrial orifice with minimal collateral thermal effect and minimal platelet and fibrin deposition observed histologically. Results: Chronic animal studies (n = 9) were carried out to 30- and 60-day time points and exhibited sustained shunt patency with histology demonstrating completely healed margins, endothelialization, and no trauma to adjacent atrial tissue. Preliminary clinical safety and feasibility were validated in a first-in-human study in patients with heart failure with preserved ejection fraction (n = 15). All patients demonstrated shunt patency by transesophageal echocardiographic imaging at 1, 3, and 6 months, as well as cardiac computed tomography imaging at 6-month follow-up timepoints. Conclusions: Combined, these data support the safety and feasibility of a novel no-implant approach to creating an interatrial shunt using the Alleviant System. Continued follow-up and subsequent clinical studies are currently ongoing.

16.
J Clin Med ; 10(20)2021 Oct 09.
Article in English | MEDLINE | ID: mdl-34682750

ABSTRACT

The new-generation ACURATE neo2 system was commercially released in September 2020. In this study, we sought to compare the aortic regurgitation (AR) severity of the ACURATE neo2 versus the ACURATE neo transcatheter heart valve, using quantitative videodensitometric angiography (qAR). This is a retrospective, Corelab analysis of final post-transcatheter aortic valve implantation (TAVI) aortograms of patients treated with the ACURATE neo2 and ACURATE neo systems. The ACURATE neo2 cohort comprised consecutive patients treated between September 2020 and January 2021 at two centers. The ACURATE neo cohort included consecutive patients treated before September 2020. Our primary objective was to compare AR severity on qAR following TAVI with ACURATE neo2 and ACURATE neo. Out of 401 aortograms, 228 (56.9%) were analyzable, with 120 in the ACURATE neo2 cohort, and 108 in the ACURATE neo cohort. The mean AR fraction was 4.4 ± 4.8% in the neo2 cohort, and 9.9 ± 8.2% in the neo cohort (p < 0.001). Furthermore, moderate or severe AR (qAR > 17%) was detected in 2 aortograms (1.7%) in the neo2 cohort and 15 aortograms (13.9%) in the neo cohort (p < 0.001). Quantitative aortography shows a lower rate of moderate or severe paravalvular AR in what is the first European experience of the new-generation, self-expanding ACURATE neo2 when compared to the first-generation ACURATE neo. Moreover, aortographic data need to be correlated and compared to Core Laboratory-adjudicated 30-day echocardiographic data.

17.
JACC Cardiovasc Interv ; 14(8): 830-845, 2021 04 26.
Article in English | MEDLINE | ID: mdl-33888229

ABSTRACT

OBJECTIVES: The aim of this study was to evaluate 1-year outcomes of valve-in-mitral annular calcification (ViMAC) in the MITRAL (Mitral Implantation of Transcatheter Valves) trial. BACKGROUND: The MITRAL trial is the first prospective study evaluating the feasibility of ViMAC using balloon-expandable aortic transcatheter heart valves. METHODS: A multicenter prospective study was conducted, enrolling high-risk surgical patients with severe mitral annular calcification and symptomatic severe mitral valve dysfunction at 13 U.S. sites. RESULTS: Between February 2015 and December 2017, 31 patients were enrolled (median age 74.5 years [interquartile range (IQR): 71.3 to 81.0 years], 71% women, median Society of Thoracic Surgeons score 6.3% [IQR: 5.0% to 8.8%], 87.1% in New York Heart Association functional class III or IV). Access was transatrial (48.4%), transseptal (48.4%), or transapical (3.2%). Technical success was 74.2%. Left ventricular outflow tract obstruction (LVOTO) with hemodynamic compromise occurred in 3 patients (transatrial, n = 1; transseptal, n = 1; transapical, n = 1). After LVOTO occurred in the first 2 patients, pre-emptive alcohol septal ablation was implemented to decrease risk in high-risk patients. No intraprocedural deaths or conversions to open heart surgery occurred during the index procedures. All-cause mortality at 30 days was 16.7% (transatrial, 21.4%; transseptal, 6.7%; transapical, 100% [n = 1]; p = 0.33) and at 1 year was 34.5% (transatrial, 38.5%; transseptal, 26.7%; p = 0.69). At 1-year follow-up, 83.3% of patients were in New York Heart Association functional class I or II, the median mean mitral valve gradient was 6.1 mm Hg (IQR: 5.6 to 7.1 mm Hg), and all patients had ≤1+ mitral regurgitation. CONCLUSIONS: At 1 year, ViMAC was associated with symptom improvement and stable transcatheter heart valve performance. Pre-emptive alcohol septal ablation may prevent transcatheter mitral valve replacement-induced LVOTO in patients at risk. Thirty-day mortality of patients treated via transseptal access was lower than predicted by the Society of Thoracic Surgeons score. Further studies are needed to evaluate safety and efficacy of ViMAC.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Aged , Aged, 80 and over , Cardiac Catheterization , Female , Humans , Male , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Prospective Studies , Retrospective Studies , Treatment Outcome
18.
JACC Cardiovasc Interv ; 14(8): 859-872, 2021 04 26.
Article in English | MEDLINE | ID: mdl-33888231

ABSTRACT

OBJECTIVES: The aim of this study was to assess 1-year clinical outcomes among high-risk patients with failed surgical mitral bioprostheses who underwent transseptal mitral valve-in-valve (MViV) with the SAPIEN 3 aortic transcatheter heart valve (THV) in the MITRAL (Mitral Implantation of Transcatheter Valves) trial. BACKGROUND: The MITRAL trial is the first prospective study evaluating transseptal MViV with the SAPIEN 3 aortic THV in high-risk patients with failed surgical mitral bioprostheses. METHODS: High-risk patients with symptomatic moderate to severe or severe mitral regurgitation (MR) or severe mitral stenosis due to failed surgical mitral bioprostheses were prospectively enrolled. The primary safety endpoint was technical success. The primary THV performance endpoint was absence of MR grade ≥2+ or mean mitral valve gradient ≥10 mm Hg (30 days and 1 year). Secondary endpoints included procedural success and all-cause mortality (30 days and 1 year). RESULTS: Thirty patients were enrolled between July 2016 and October 2017 (median age 77.5 years [interquartile range (IQR): 70.3 to 82.8 years], 63.3% women, median Society of Thoracic Surgeons score 9.4% [IQR: 5.8% to 12.0%], 80% in New York Heart Association functional class III or IV). The technical success rate was 100%. The primary performance endpoint in survivors was achieved in 96.6% (28 of 29) at 30 days and 82.8% (24 of 29) at 1 year. Thirty-day all-cause mortality was 3.3% and was unchanged at 1 year. The only death was due to airway obstruction after swallowing several pills simultaneously 29 days post-MViV. At 1-year follow-up, 89.3% of patients were in New York Heart Association functional class I or II, the median mean mitral valve gradient was 6.6 mm Hg (interquartile range: 5.5 to 8.9 mm Hg), and all patients had MR grade ≤1+. CONCLUSIONS: Transseptal MViV in high-risk patients was associated with 100% technical success, low procedural complication rates, and very low mortality at 1 year. The vast majority of patients experienced significant symptom alleviation, and THV performance remained stable at 1 year.


Subject(s)
Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Annuloplasty , Aged , Aged, 80 and over , Cardiac Catheterization/adverse effects , Female , Heart Valve Prosthesis Implantation/adverse effects , Humans , Male , Prospective Studies , Prosthesis Design , Treatment Outcome
19.
JACC Cardiovasc Interv ; 14(8): 846-858, 2021 04 26.
Article in English | MEDLINE | ID: mdl-33888230

ABSTRACT

OBJECTIVES: The authors report 1-year outcomes of high-risk patients with failed surgical annuloplasty rings undergoing transseptal mitral valve-in-ring (MViR) with the SAPIEN 3 aortic transcatheter heart valve (THV). BACKGROUND: The MITRAL (Mitral Implantation of Transcatheter Valves) trial is the first prospective study evaluating transseptal MViR with the SAPIEN 3 aortic THV in high-risk patients with failed surgical annuloplasty rings. METHODS: Prospective enrollment of high-risk patients with symptomatic moderate to severe or severe mitral regurgitation (MR) or severe mitral stenosis and failed annuloplasty rings at 13 U.S. sites. The primary safety endpoint was technical success. The primary THV performance endpoint was absence of MR grade ≥2+ or mean mitral valve gradient ≥10 mm Hg (30 days and 1 year). Secondary endpoints included procedural success and all-cause mortality (30 days and 1 year). RESULTS: Thirty patients were enrolled between January 2016 and October 2017 (median age 71.5 years [interquartile range: 67.0 to 76.8 years], 36.7% women, median Society of Thoracic Surgeons score 7.6% [interquartile range: 5.1% to 11.8%], 76.7% in New York Heart Association functional class III or IV). Technical success was 66.7% (driven primarily by need for a second valve in 6 patients). There was no intraprocedural mortality or conversion to surgery. The primary performance endpoint was achieved in 85.7% of survivors at 30 days (24 of 28) and 89.5% of patients alive at 1 year with echocardiographic data available (17 of 19). All-cause mortality at 30 days was 6.7% and at 1 year was 23.3%. Among survivors at 1-year follow-up, 84.2% were in New York Heart Association functional class I or II, the median mean mitral valve gradient was 6.0 mm Hg (interquartile range: 4.7 to 7.3 mm Hg), and all had ≤1+ MR. CONCLUSIONS: Transseptal MViR was associated with a 30-day mortality rate lower than predicted by the Society of Thoracic Surgeons score. At 1 year, transseptal MViR was associated with symptom improvement and stable THV performance.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Annuloplasty , Mitral Valve Insufficiency , Aged , Cardiac Catheterization/adverse effects , Female , Heart Valve Prosthesis Implantation/adverse effects , Humans , Male , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Annuloplasty/adverse effects , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Prospective Studies , Prosthesis Design , Treatment Outcome
SELECTION OF CITATIONS