Radiol Med ; 129(6): 901-911, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38700556

ABSTRACT

PURPOSE: High PSMA expression might be correlated with structural characteristics such as growth patterns on histopathology, not recognized by the human eye on MRI images. Deep structural image analysis might be able to detect such differences and therefore predict if a lesion would be PSMA positive. Therefore, we aimed to train a neural network based on PSMA PET/MRI scans to predict increased prostatic PSMA uptake based on the axial T2-weighted sequence alone. MATERIAL AND METHODS: All patients undergoing simultaneous PSMA PET/MRI for PCa staging or biopsy guidance between April 2016 and December 2020 at our institution were selected. To increase the specificity of our model, the prostatic beds on PSMA PET scans were dichotomized in positive and negative regions using an SUV threshold greater than 4 to generate a PSMA PET map. Then, a C-ENet was trained on the T2 images of the training cohort to generate a predictive prostatic PSMA PET map. RESULTS: One hundred and fifty-four PSMA PET/MRI scans were available (133 [68Ga]Ga-PSMA-11 and 21 [18F]PSMA-1007). Significant cancer was present in 127 of them. The whole dataset was divided into a training cohort (n = 124) and a test cohort (n = 30). The C-ENet was able to predict the PSMA PET map with a dice similarity coefficient of 69.5 ± 15.6%. CONCLUSION: Increased prostatic PSMA uptake on PET might be estimated based on T2 MRI alone. Further investigation with larger cohorts and external validation is needed to assess whether PSMA uptake can be predicted accurately enough to help in the interpretation of mpMRI.


Subject(s)
Deep Learning , Magnetic Resonance Imaging , Prostatic Neoplasms , Humans , Male , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology , Aged , Magnetic Resonance Imaging/methods , Middle Aged , Prostate/diagnostic imaging , Positron-Emission Tomography/methods , Retrospective Studies , Glutamate Carboxypeptidase II/metabolism , Antigens, Surface/metabolism , Predictive Value of Tests , Organ Size , Gallium Radioisotopes , Radiopharmaceuticals/pharmacokinetics
2.
Int J Cardiovasc Imaging ; 40(5): 951-966, 2024 May.
Article in English | MEDLINE | ID: mdl-38700819

ABSTRACT

Almost 35 years after its introduction, coronary artery calcium score (CACS) not only survived technological advances but became one of the cornerstones of contemporary cardiovascular imaging. Its simplicity and quantitative nature established it as one of the most robust approaches for atherosclerotic cardiovascular disease risk stratification in primary prevention and a powerful tool to guide therapeutic choices. Groundbreaking advances in computational models and computer power translated into a surge of artificial intelligence (AI)-based approaches directly or indirectly linked to CACS analysis. This review aims to provide essential knowledge on the AI-based techniques currently applied to CACS, setting the stage for a holistic analysis of the use of these techniques in coronary artery calcium imaging. While the focus of the review will be detailing the evidence, strengths, and limitations of end-to-end CACS algorithms in electrocardiography-gated and non-gated scans, the current role of deep-learning image reconstructions, segmentation techniques, and combined applications such as simultaneous coronary artery calcium and pulmonary nodule segmentation, will also be discussed.


Subject(s)
Coronary Angiography , Coronary Artery Disease , Coronary Vessels , Deep Learning , Predictive Value of Tests , Radiographic Image Interpretation, Computer-Assisted , Vascular Calcification , Humans , Vascular Calcification/diagnostic imaging , Vascular Calcification/therapy , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Vessels/diagnostic imaging , Prognosis , Computed Tomography Angiography , Reproducibility of Results , Severity of Illness Index , Artificial Intelligence , Cardiac-Gated Imaging Techniques
3.
EJNMMI Res ; 14(1): 36, 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38578516

ABSTRACT

BACKGROUND: Liver uptake in [68Ga]Ga-PSMA-11 PET is used as an internal reference in addition to clinical parameters to select patients for [177Lu]Lu-PSMA-617 radioligand therapy (RLT). Due to increased demand, [68Ga]Ga-PSMA-11 was replaced by [18F]F-PSMA-1007, a more lipophilic tracer with different biodistribution and splenic uptake was suggested as a new internal reference. We compared the intra-patient tracer distribution between [68Ga]Ga-PSMA-11 and [18F]F-PSMA-1007. METHODS: Fifty patients who underwent PET examinations in two centers with both [18F]F-PSMA-1007 and [68Ga]Ga-PSMA-11 within one year were included. Mean standardized uptake values (SUVmean) were obtained for liver, spleen, salivary glands, blood pool, and bone. Primary tumor, local recurrence, lymph node, bone or visceral metastasis were also assessed for intra- and inter-individual comparison. RESULTS: Liver SUVmean was significantly higher with [18F]F-PSMA-1007 (11.7 ± 3.9) compared to [68Ga]Ga-PSMA-11 (5.4 ± 1.7, p < .05) as well as splenic SUVmean (11.2 ± 3.5 vs.8.1 ± 3.5, p < .05). The blood pool was comparable between the two scans. Malignant lesions did not show higher SUVmean on [18F]F-PSMA-1007. Intra-individual comparison of liver uptake between the two scans showed a linear association for liver uptake with SUVmean [68Ga]Ga-PSMA-11 = 0.33 x SUVmean [18F]F-PSMA-1007 + 1.52 (r = .78, p < .001). CONCLUSION: Comparing biodistribution of [68Ga]Ga and [18F]F tracers, liver uptake on [68Ga]Ga-PSMA-11 PET is the most robust internal reference value. Liver uptake of [18F]F-PSMA-1007 was significantly higher, but so was the splenic uptake. The strong intra-individual association of hepatic accumulation between the two scans may allow using of a conversion factor for [18F]F-PSMA-1007 as a basis for RLT selection.

4.
Clin Nucl Med ; 2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38651767

ABSTRACT

BACKGROUND: The aim of our study was to retrospectively analyze FDG PET/CT data in patients with facial nerve palsy (FNP) for the presence of the monocle sign. PATIENTS AND METHODS: A total of 85 patients with unilateral FNP were included into our study, thereof 73 with peripheral FNP and 12 with central FNP. FDG uptake (SUVmax, SUVmean, total lesion glycolysis) was measured in both orbicularis oculi muscles (OOMs). FDG uptake of paretic and nonparetic muscles was compared in patients with FNP (Wilcoxon test and Mann-Whitney U test) and was also compared with FDG uptake in 33 patients without FNP (Mann-Whitney U test). SUVmax ratios of OOM were compared. A receiver operating characteristic curve and Youden Index were used to determine the optimal cutoff SUVmax ratio for the prevalence of contralateral peripheral FNP. RESULTS: The SUVmax ratio of OOM was significantly higher in patients with peripheral FNP compared with patients with central FNP and those without FNP (1.70 ± 0.94 vs 1.16 ± 0.09 vs 1.18 ± 0.21, respectively; P < 0.001). The SUVmax ratio of OOM yielded an area under the curve (AUC) of 0.719 (95% confidence interval, 0.630-0.809), with an optimal cutoff of 1.41, yielding a specificity of 94.4% and a sensitivity of 44.1% for identifying contralateral peripheral FNP. One hundred percent specificity is achieved using a cutoff of 1.91 (sensitivity, 29.4%). CONCLUSIONS: Asymmetrically increased FDG uptake of the OOM (the "monocle sign") indicates contralateral peripheral FNP. A nearly 2-fold higher SUVmax represents a practically useful cutoff.

5.
Erkenntnis ; 89(1): 65-87, 2024.
Article in English | MEDLINE | ID: mdl-38303983

ABSTRACT

In the last seven years, philosophers have discussed the topic of transformative experiences. In this paper, we contribute to a crucial issue that is currently under-researched: transformative experiences' influence on cognitive modelling. We argue that cognitive modelling can be operationalized as affective forecasting, and we compare transformative and non-transformative experiences with respect to the ability of affective forecasting. Our finding is that decision-makers' performance in cognitively modelling transformative experiences does not systematically differ from decision-makers' performance in cognitively modelling non-transformative experiences. This claim stands in strict opposition to L.A. Paul's main argument.

6.
Euro Surveill ; 29(2)2024 Jan.
Article in English | MEDLINE | ID: mdl-38214079

ABSTRACT

BackgroundWomen are overrepresented among individuals with post-acute sequelae of SARS-CoV-2 infection (PASC). Biological (sex) as well as sociocultural (gender) differences between women and men might account for this imbalance, yet their impact on PASC is unknown.AimWe assessed the impact of sex and gender on PASC in a Swiss population.MethodOur multicentre prospective cohort study included 2,856 (46% women, mean age 44.2 ± 16.8 years) outpatients and hospitalised patients with PCR-confirmed SARS-CoV-2 infection.ResultsAmong those who remained outpatients during their first infection, women reported persisting symptoms more often than men (40.5% vs 25.5% of men; p < 0.001). This sex difference was absent in hospitalised patients. In a crude analysis, both female biological sex (RR = 1.59; 95% CI: 1.41-1.79; p < 0.001) and a score summarising gendered sociocultural variables (RR = 1.05; 95% CI: 1.03-1.07; p < 0.001) were significantly associated with PASC. Following multivariable adjustment, biological female sex (RR = 0.96; 95% CI: 0.74-1.25; p = 0.763) was outperformed by feminine gender-related factors such as a higher stress level (RR = 1.04; 95% CI: 1.01-1.06; p = 0.003), lower education (RR = 1.16; 95% CI: 1.03-1.30; p = 0.011), being female and living alone (RR = 1.91; 95% CI: 1.29-2.83; p = 0.001) or being male and earning the highest income in the household (RR = 0.76; 95% CI: 0.60-0.97; p = 0.030).ConclusionSpecific sociocultural parameters that differ in prevalence between women and men, or imply a unique risk for women, are predictors of PASC and may explain, at least in part, the higher incidence of PASC in women. Once patients are hospitalised during acute infection, sex differences in PASC are no longer evident.


Subject(s)
COVID-19 , Female , Humans , Male , Adult , Middle Aged , COVID-19/epidemiology , Post-Acute COVID-19 Syndrome , Switzerland/epidemiology , Prospective Studies , SARS-CoV-2 , Disease Progression
7.
Angiology ; 75(4): 367-374, 2024 Apr.
Article in English | MEDLINE | ID: mdl-36786297

ABSTRACT

Myocardial bridging (MB) is a segment of coronary arteries with an intramural course, typically spared from atherosclerosis, while the adjacent proximal segment is reported to be atherosclerosis-prone, a phenomenon contributed to local endothelial shear stress (ESS). We aimed to describe the ESS milieu in coronaries with MBs combining coronary computed tomography angiography with computational fluid dynamics and to investigate the association of atherosclerosis presence proximal to MBs with hemorheological characteristics. Patients (n = 36) were identified and 36 arteries with MBs (11 deep and 25 superficial) were analyzed. ESS did not fluctuate 5 mm proximally to MBs vs 5 mm within MBs (0.94 vs 1.06 Pa, p = .56). There was no difference when comparing ESS in the proximal versus mid versus distal MB segments (1.48 vs 1.37 vs 1.9 Pa, p = ns). In arteries with plaques (n = 12), no significant ESS variances were observed around the MB entrance, when analyzing all arteries (p = .81) and irrespective of morphological features of the bridged segment (deep MBs; p = .65, superficial MBs; p = .84). MBs are characterized by homogeneous, atheroprotective ESS, possibly explaining the absence of atherosclerosis within bridged segments. The interplay between ESS and atherosclerosis is potentially not different in arteries with MB compared with arteries without bridges.


Subject(s)
Atherosclerosis , Coronary Artery Disease , Humans , Coronary Artery Disease/diagnostic imaging , Computed Tomography Angiography , Coronary Angiography/methods , Heart , Coronary Vessels/diagnostic imaging
8.
Diagn Interv Imaging ; 105(4): 151-158, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38007373

ABSTRACT

PURPOSE: The invasive British Cardiovascular Intervention Society Jeopardy Score (iBCIS-JS) is a simple angiographic scoring system, enabling quantification of the extent of jeopardized myocardium related to clinically significant coronary artery disease (CAD). The purpose of this study was to develop and validate the coronary CT angiography-based BCIS-JS (CT-BCIS-JS) against the iBCIS-JS in patients with suspected or stable CAD. MATERIALS AND METHODS: Patients who underwent coronary CT angiography followed by invasive coronary angiography, within 90 days were retrospectively included. CT-BCIS-JS and iBCIS-JS were calculated, with a score ≥ 6 indicating extensive CAD. Correlation between the CT-BCIS-JS and iBCIS-JS was searched for using Spearman's coefficient, and agreement with weighted Kappa (κ) analyses. RESULTS: A total of 122 patients were included. There were 102 men and 20 women with a median age of 62 years (Q1, Q3: 54, 68; age range: 19-83 years). No differences in median CT-BCIS-JS (4; Q1, Q3: 0, 8) and median iBCIS-JS (4; Q1, Q3: 0, 8) were found (P = 0.18). Extensive CAD was identified in 53 (43.4%) and 52 (42.6%) patients using CT-BCIS-JS and iBCIS-JS, respectively (P = 0.88). CT-based and iBCIS-JS showed excellent correlation (r = 0.98; P < 0.001) and almost perfect agreement (κ = 0.93; 95% confidence interval: 0.90-0.97). Agreement for identification of an iBCIS-JS ≥ 6 was almost perfect (κ = 0.94; 95 % confidence interval: 0.87-0.99). CONCLUSION: The CT-BCIS-JS represents a feasible, and accurate method for quantification of CAD, with capabilities not different from those of iBCIS-JS. It enables simple, non-invasive identification of patients with anatomically extensive CAD.


Subject(s)
Coronary Artery Disease , Male , Humans , Female , Middle Aged , Young Adult , Adult , Aged , Aged, 80 and over , Coronary Artery Disease/diagnostic imaging , Coronary Angiography/methods , Computed Tomography Angiography , Retrospective Studies , Tomography, X-Ray Computed , Predictive Value of Tests
9.
Eur Radiol ; 34(3): 1716-1723, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37644149

ABSTRACT

OBJECTIVES: To introduce an automated computational algorithm that estimates the global noise level across the whole imaging volume of PET datasets. METHODS: [18F]FDG PET images of 38 patients were reconstructed with simulated decreasing acquisition times (15-120 s) resulting in increasing noise levels, and with block sequential regularized expectation maximization with beta values of 450 and 600 (Q.Clear 450 and 600). One reader performed manual volume-of-interest (VOI) based noise measurements in liver and lung parenchyma and two readers graded subjective image quality as sufficient or insufficient. An automated computational noise measurement algorithm was developed and deployed on the whole imaging volume of each reconstruction, delivering a single value representing the global image noise (Global Noise Index, GNI). Manual noise measurement values and subjective image quality gradings were compared with the GNI. RESULTS: Irrespective of the absolute noise values, there was no significant difference between the GNI and manual liver measurements in terms of the distribution of noise values (p = 0.84 for Q.Clear 450, and p = 0.51 for Q.Clear 600). The GNI showed a fair to moderately strong correlation with manual noise measurements in liver parenchyma (r = 0.6 in Q.Clear 450, r = 0.54 in Q.Clear 600, all p < 0.001), and a fair correlation with manual noise measurements in lung parenchyma (r = 0.52 in Q.Clear 450, r = 0.33 in Q.Clear 600, all p < 0.001). Classification performance of the GNI for subjective image quality was AUC 0.898 for Q.Clear 450 and 0.919 for Q.Clear 600. CONCLUSION: An algorithm provides an accurate and meaningful estimation of the global noise level encountered in clinical PET imaging datasets. CLINICAL RELEVANCE STATEMENT: An automated computational approach that measures the global noise level of PET imaging datasets may facilitate quality standardization and benchmarking of clinical PET imaging within and across institutions. KEY POINTS: • Noise is an important quantitative marker that strongly impacts image quality of PET images. • An automated computational noise measurement algorithm provides an accurate and meaningful estimation of the global noise level encountered in clinical PET imaging datasets. • An automated computational approach that measures the global noise level of PET imaging datasets may facilitate quality standardization and benchmarking as well as protocol harmonization.


Subject(s)
Image Processing, Computer-Assisted , Positron-Emission Tomography , Humans , Image Processing, Computer-Assisted/methods , Positron-Emission Tomography/methods , Fluorodeoxyglucose F18 , Liver/diagnostic imaging , Algorithms , Positron Emission Tomography Computed Tomography , Phantoms, Imaging
10.
Sci Rep ; 13(1): 18847, 2023 11 01.
Article in English | MEDLINE | ID: mdl-37914764

ABSTRACT

The purpose of this retrospective study was to investigate response of sinonasal mucosal melanoma (SMM) patients to treatment with immune checkpoint inhibitors (ICI), using hybrid PET imaging. Fifteen SMM patients underwent hybrid PET imaging before and three months after initiation of ICI. The disease-specific survival (DSS) was calculated. Quantitative PET parameters of the primary tumor and their association with DSS and therapy response were investigated. Nine of the fifteen (60%) patients responded to ICI therapy. Patients with therapy response depicted on hybrid PET imaging had better DSS than those without (p = 0.0058). Quantitative PET parameters of the initial PET harbored no association with DSS or therapy response. However, these findings lack of sufficient statistical power and must be interpreted with caution. The first restaging PET-imaging after ICI initiation can help stratify patients with regard to DSS.


Subject(s)
Melanoma , Paranasal Sinus Neoplasms , Humans , Immune Checkpoint Inhibitors/pharmacology , Immune Checkpoint Inhibitors/therapeutic use , Positron Emission Tomography Computed Tomography/methods , Retrospective Studies , Melanoma/diagnostic imaging , Melanoma/drug therapy , Melanoma/pathology , Positron-Emission Tomography , Paranasal Sinus Neoplasms/pathology , Fluorodeoxyglucose F18
11.
Cancers (Basel) ; 15(22)2023 Nov 19.
Article in English | MEDLINE | ID: mdl-38001731

ABSTRACT

OBJECTIVE: The increasing use of PSMA-PET/CT for restaging prostate cancer (PCa) leads to a patient shift from a non-metastatic situation based on conventional imaging (CI) to a metastatic situation. Since established therapeutic pathways have been designed according to CI, it is unclear how this should be translated to the PSMA-PET/CT results. This study aimed to investigate whether PSMA-PET/CT and clinical parameters could predict the visibility of PSMA-positive lesions on a bone scan (BS). METHODS: In four different centers, all PCa patients with BS and PSMA-PET/CT within 6 months without any change in therapy or significant disease progression were retrospectively selected. Up to 10 non-confluent clear bone metastases were selected per PSMA-PET/CT and SUVmax, SUVmean, PSMAtot, PSMAvol, density, diameter on CT, and presence of cortical erosion were collected. Clinical variables (age, PSA, Gleason Score) were also considered. Two experienced double-board physicians decided whether a bone metastasis was visible on the BS, with a consensus readout for discordant findings. For predictive performance, a random forest was fit on all available predictors, and its accuracy was assessed using 10-fold cross-validation performed 10 times. RESULTS: A total of 43 patients were identified with 222 bone lesions on PSMA-PET/CT. A total of 129 (58.1%) lesions were visible on the BS. In the univariate analysis, all PSMA-PET/CT parameters were significantly associated with the visibility on the BS (p < 0.001). The random forest reached a mean accuracy of 77.6% in a 10-fold cross-validation. CONCLUSIONS: These preliminary results indicate that there might be a way to predict the BS results based on PSMA-PET/CT, potentially improving the comparability between both examinations and supporting decisions for therapy selection.

12.
Sci Rep ; 13(1): 18357, 2023 10 26.
Article in English | MEDLINE | ID: mdl-37884535

ABSTRACT

This study aimed to evaluate the diagnostic accuracy of Node Reporting and Data System (Node-RADS) in discriminating between normal, reactive, and metastatic axillary LNs in patients with melanoma who underwent SARS-CoV-2 vaccination. Patients with proven melanoma who underwent a 2-[18F]-fluoro-2-deoxy-D-glucose positron emission tomography/computed tomography (2-[18F]-FDG PET/CT) between February and April 2021 were included in this retrospective study. Primary melanoma site, vaccination status, injection site, and 2-[18F]-FDG PET/CT were used to classify axillary LNs into normal, inflammatory, and metastatic (combined classification). An adapted Node-RADS classification (A-Node-RADS) was generated based on LN anatomical characteristics on low-dose CT images and compared to the combined classification. 108 patients were included in the study (54 vaccinated). HALNs were detected in 42 patients (32.8%), of whom 97.6% were vaccinated. 172 LNs were classified as normal, 30 as inflammatory, and 14 as metastatic using the combined classification. 152, 22, 29, 12, and 1 LNs were classified A-Node-RADS 1, 2, 3, 4, and 5, respectively. Hence, 174, 29, and 13 LNs were deemed benign, equivocal, and metastatic. The concordance between the classifications was very good (Cohen's k: 0.91, CI 0.86-0.95; p-value < 0.0001). A-Node-RADS can assist the classification of axillary LNs in melanoma patients who underwent 2-[18F]-FDG PET/CT and SARS-CoV-2 vaccination.


Subject(s)
COVID-19 , Melanoma , Humans , Positron Emission Tomography Computed Tomography/methods , COVID-19 Vaccines , SARS-CoV-2 , Fluorodeoxyglucose F18 , Retrospective Studies , Neoplasm Staging , Lymphatic Metastasis/pathology , COVID-19/diagnostic imaging , COVID-19/pathology , Lymph Nodes/diagnostic imaging , Lymph Nodes/pathology , Melanoma/diagnostic imaging , Melanoma/pathology , Vaccination , Radiopharmaceuticals
13.
Eur Radiol ; 2023 Oct 19.
Article in English | MEDLINE | ID: mdl-37855853

ABSTRACT

OBJECTIVES: To assess the evolution of administered radiotracer activity for F-18-fluorodeoxyglucose (18F-FDG) PET/CT or PET/MR in pediatric patients (0-16 years) between years 2000 and 2021. METHODS: Pediatric patients (≤ 16 years) referred for 18F-FDG PET/CT or PET/MR imaging of the body during 2000 and 2021 were retrospectively included. The amount of administered radiotracer activity in megabecquerel (MBq) was recorded, and signal-to-noise ratio (SNR) was measured in the right liver lobe with a 4 cm3 volume of interest as an indicator for objective image quality. Descriptive statistics were computed. RESULTS: Two hundred forty-three children and adolescents underwent a total of 466 examinations. The median injected 18F-FDG activity in MBq decreased significantly from 296 MBq in 2000-2005 to 100 MBq in 2016-2021 (p < 0.001), equaling approximately one-third of the initial amount. The median SNR ratio was stable during all years with 11.7 (interquartile range [IQR] 10.7-12.9, p = 0.133). CONCLUSIONS: Children have benefited from a massive reduction in the administered 18F-FDG dose over the past 20 years without compromising objective image quality. CLINICAL RELEVANCE STATEMENT: Radiotracer dose was reduced considerably over the past two decades of pediatric F-18-fluorodeoxyglucose PET/CT and PET/MR imaging highlighting the success of technical innovations in pediatric PET imaging. KEY POINTS: • The evolution of administered radiotracer activity for F-18-fluorodeoxyglucose (18F-FDG) PET/CT or PET/MR in pediatric patients (0-16 years) between 2000 and 2021 was assessed. • The injected tracer activity decreased by 66% during the study period from 296 megabecquerel (MBq) to 100 MBq (p < 0.001). • The continuous implementation of technical innovations in pediatric hybrid 18F-FDG PET has led to a steady decrease in the amount of applied radiotracer, which is particularly beneficial for children who are more sensitive to radiation.

14.
Br J Radiol ; 96(1152): 20220482, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37751216

ABSTRACT

OBJECTIVES: To evaluate the evolution of CT radiation dose in pediatric patients undergoing hybrid 2-[18F]fluoro-2-deoxy-D-glucose (2-[18F]FDG) PET/CT between 2007 and 2021. METHODS AND MATERIALS: Data from all pediatric patients aged 0-18 years who underwent hybrid 2-[18F]FDG PET/CT of the body between January 2007 and May 2021 were reviewed. Demographic and imaging parameters were collected. A board-certified radiologist reviewed all CT scans and measured image noise in the brain, liver, and adductor muscles. RESULTS: 294 scans from 167 children (72 females (43%); median age: 14 (IQR 10-15) years; BMI: median 17.5 (IQR 15-20.4) kg/m2) were included. CT dose index-volume (CTDIvol) and dose length product (DLP) both decreased significantly from 2007 to 2021 (both p < 0.001, Spearman's rho coefficients -0.46 and -0.35, respectively). Specifically, from 2007 to 2009 to 2019-2021 CTDIvol and DLP decreased from 2.94 (2.14-2.99) mGy and 309 (230-371) mGy*cm, respectively, to 0.855 (0.568-1.11) mGy and 108 (65.6-207) mGy*cm, respectively. From 2007 to 2021, image noise in the brain and liver remained constant (p = 0.26 and p = 0.06), while it decreased in the adductor muscles (p = 0.007). Peak tube voltage selection (in kilovolt, kV) of CT scans shifted from high kV imaging (140 or 120kVp) to low kV imaging (100 or 80kVp) (p < 0.001) from 2007 to 2021. CONCLUSION: CT radiation dose in pediatric patients undergoing hybrid 2-[18F]FDG PET/CT has decreased in recent years equaling approximately one-third of the initial amount. ADVANCES IN KNOWLEDGE: Over the past 15 years, CT radiation dose decreased considerably in pediatric patients undergoing hybrid imaging, while objective image quality may not have been compromised.


Subject(s)
Fluorodeoxyglucose F18 , Positron Emission Tomography Computed Tomography , Female , Humans , Child , Adolescent , Radiation Dosage , Tomography, X-Ray Computed/methods , Brain
15.
Nat Commun ; 14(1): 5154, 2023 08 24.
Article in English | MEDLINE | ID: mdl-37620318

ABSTRACT

Immune checkpoint inhibitor treatment has the potential to prolong survival in non-small cell lung cancer (NSCLC), however, some of the patients develop resistance following initial response. Here, we analyze the immune phenotype of matching tumor samples from a cohort of NSCLC patients showing good initial response to immune checkpoint inhibitors, followed by acquired resistance at later time points. By using imaging mass cytometry and whole exome and RNA sequencing, we detect two patterns of resistance¨: One group of patients is characterized by reduced numbers of tumor-infiltrating CD8+ T cells and reduced expression of PD-L1 after development of resistance, whereas the other group shows high CD8+ T cell infiltration and high expression of PD-L1 in addition to markedly elevated expression of other immune-inhibitory molecules. In two cases, we detect downregulation of type I and II IFN pathways following progression to resistance, which could lead to an impaired anti-tumor immune response. This study thus captures the development of immune checkpoint inhibitor resistance as it progresses and deepens our mechanistic understanding of immunotherapy response in NSCLC.


Subject(s)
Carcinoma, Non-Small-Cell Lung , Lung Neoplasms , Humans , Carcinoma, Non-Small-Cell Lung/drug therapy , Carcinoma, Non-Small-Cell Lung/genetics , CD8-Positive T-Lymphocytes , B7-H1 Antigen/genetics , Immune Checkpoint Inhibitors , Lung Neoplasms/drug therapy , Lung Neoplasms/genetics , Immunosuppressive Agents , Phenotype
16.
Sci Rep ; 13(1): 11332, 2023 07 13.
Article in English | MEDLINE | ID: mdl-37443158

ABSTRACT

To evaluate whether a machine learning classifier can evaluate image quality of maximum intensity projection (MIP) images from F18-FDG-PET scans. A total of 400 MIP images from F18-FDG-PET with simulated decreasing acquisition time (120 s, 90 s, 60 s, 30 s and 15 s per bed-position) using block sequential regularized expectation maximization (BSREM) with a beta-value of 450 and 600 were created. A machine learning classifier was fed with 283 images rated "sufficient image quality" and 117 images rated "insufficient image quality". The classification performance of the machine learning classifier was assessed by calculating sensitivity, specificity, and area under the receiver operating characteristics curve (AUC) using reader-based classification as the target. Classification performance of the machine learning classifier was AUC 0.978 for BSREM beta 450 and 0.967 for BSREM beta 600. The algorithm showed a sensitivity of 89% and 94% and a specificity of 94% and 94% for the reconstruction BSREM 450 and 600, respectively. Automated assessment of image quality from F18-FDG-PET images using a machine learning classifier provides equivalent performance to manual assessment by experienced radiologists.


Subject(s)
Fluorodeoxyglucose F18 , Positron Emission Tomography Computed Tomography , Positron Emission Tomography Computed Tomography/methods , Positron-Emission Tomography , Neural Networks, Computer , Algorithms , Image Processing, Computer-Assisted/methods
17.
Diagnostics (Basel) ; 13(4)2023 Feb 08.
Article in English | MEDLINE | ID: mdl-36832118

ABSTRACT

BACKGROUND: To assess the impact of the lung cancer screening protocol recommended by the European Society of Thoracic Imaging (ESTI) on nodule diameter, volume, and density throughout different computed tomography (CT) scanners. METHODS: An anthropomorphic chest phantom containing fourteen different-sized (range 3-12 mm) and CT-attenuated (100 HU, -630 HU and -800 HU, termed as solid, GG1 and GG2) pulmonary nodules was imaged on five CT scanners with institute-specific standard protocols (PS) and the lung cancer screening protocol recommended by ESTI (ESTI protocol, PE). Images were reconstructed with filtered back projection (FBP) and iterative reconstruction (REC). Image noise, nodule density and size (diameter/volume) were measured. Absolute percentage errors (APEs) of measurements were calculated. RESULTS: Using PE, dosage variance between different scanners tended to decrease compared to PS, and the mean differences were statistically insignificant (p = 0.48). PS and PE(REC) showed significantly less image noise than PE(FBP) (p < 0.001). The smallest size measurement errors were noted with volumetric measurements in PE(REC) and highest with diametric measurements in PE(FBP). Volume performed better than diameter measurements in solid and GG1 nodules (p < 0.001). However, in GG2 nodules, this could not be observed (p = 0.20). Regarding nodule density, REC values were more consistent throughout different scanners and protocols. CONCLUSION: Considering radiation dose, image noise, nodule size, and density measurements, we fully endorse the ESTI screening protocol including the use of REC. For size measurements, volume should be preferred over diameter.

18.
J Nucl Cardiol ; 30(1): 313-320, 2023 02.
Article in English | MEDLINE | ID: mdl-35301677

ABSTRACT

BACKGROUND: To assess the accuracy of fully automated deep learning (DL) based coronary artery calcium scoring (CACS) from non-contrast computed tomography (CT) as acquired for attenuation correction (AC) of cardiac single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI). METHODS AND RESULTS: Patients were enrolled in this study as part of a larger prospective study (NCT03637231). In this study, 56 Patients who underwent cardiac SPECT-MPI due to suspected coronary artery disease (CAD) were prospectively enrolled. All patients underwent non-contrast CT for AC of SPECT-MPI twice. CACS was manually assessed (serving as standard of reference) on both CT datasets (n = 112) and by a cloud-based DL tool. The agreement in CAC scores and CAC score risk categories was quantified. For the 112 scans included in the analysis, interscore agreement between the CAC scores of the standard of reference and the DL tool was 0.986. The agreement in risk categories was 0.977 with a reclassification rate of 3.6%. Heart rate, image noise, body mass index (BMI), and scan did not significantly impact (p=0.09 - p=0.76) absolute percentage difference in CAC scores. CONCLUSION: A DL tool enables a fully automated and accurate estimation of CAC scores in patients undergoing non-contrast CT for AC of SPECT-MPI.


Subject(s)
Coronary Artery Disease , Deep Learning , Myocardial Perfusion Imaging , Humans , Calcium , Myocardial Perfusion Imaging/methods , Prospective Studies , Tomography, Emission-Computed, Single-Photon/methods
19.
J Nucl Cardiol ; 30(2): 616-625, 2023 04.
Article in English | MEDLINE | ID: mdl-35819716

ABSTRACT

BACKGROUND: Positron emission tomography (PET) myocardial perfusion imaging (MPI) can be used to evaluate left ventricular (LV) volumes and function. We performed a head-to-head comparison of LV function and volumes obtained simultaneously using [13N]-ammonia-PET and cardiac magnetic resonance (CMR), with the latter serving as the reference standard. METHODS AND RESULTS: In this prospective study, 51 patients underwent [13N]-ammonia-PET MPI and CMR using a hybrid PET/MR device. Left ventricular end-systolic volumes (LVESV), end-diastolic volumes (LVEDV), stroke volumes (LVSV), ejection fractions (LVEF), and segmental wall motion were analyzed for both methods and were compared using correlational and Bland-Altman (BA) analysis; segmental wall motion was compared using ANOVA. The agreement between [13N]-ammonia-PET and CMR for LVEF was good, with minimal bias (- .6%) and narrow BA limits of agreement (- 7.9% to 6.8%), but [13N]-ammonia-PET systematically underestimated LV volumes, with high bias in LVESV (- 11.2 ml), LVEDV (- 28.9 ml), and LVSV (- 17.5 ml). Mean segmental wall motion in [13N]-ammonia-PET differed significantly among the corresponding normokinetic (6.6 ± 2 mm), hypokinetic (5.1 ± 2 mm), and akinetic (3.3 ± 2 mm) segments in CMR (P < .01). CONCLUSION: LVEF and LV wall motion can be accurately assessed using [13N]-ammonia-PET MPI, although LV volumes are significantly underestimated compared to CMR.


Subject(s)
Coronary Artery Disease , Ventricular Dysfunction, Left , Humans , Ventricular Function, Left , Prospective Studies , Ammonia , Tomography, X-Ray Computed , Positron-Emission Tomography/methods , Stroke Volume , Magnetic Resonance Spectroscopy , Perfusion
20.
Eur Radiol ; 33(6): 3832-3838, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36480026

ABSTRACT

BACKGROUND: Deep learning image reconstructions (DLIR) have been recently introduced as an alternative to filtered back projection (FBP) and iterative reconstruction (IR) algorithms for computed tomography (CT) image reconstruction. The aim of this study was to evaluate the effect of DLIR on image quality and quantification of coronary artery calcium (CAC) in comparison to FBP. METHODS: One hundred patients were consecutively enrolled. Image quality-associated variables (noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR)) as well as CAC-derived parameters (Agatston score, mass, and volume) were calculated from images reconstructed by using FBP and three different strengths of DLIR (low (DLIR_L), medium (DLIR_M), and high (DLIR_H)). Patients were stratified into 4 risk categories according to the Coronary Artery Calcium - Data and Reporting System (CAC-DRS) classification: 0 Agatston score (very low risk), 1-99 Agatston score (mildly increased risk), Agatston 100-299 (moderately increased risk), and ≥ 300 Agatston score (moderately-to-severely increased risk). RESULTS: In comparison to standard FBP, increasing strength of DLIR was associated with a significant and progressive decrease of image noise (p < 0.001) alongside a significant and progressive increase of both SNR and CNR (p < 0.001). The use of incremental levels of DLIR was associated with a significant decrease of Agatston CAC score and CAC volume (p < 0.001), while mass score remained unchanged when compared to FBP (p = 0.232). The underestimation of Agatston CAC led to a CAC-DRS misclassification rate of 8%. CONCLUSION: DLIR systematically underestimates Agatston CAC score. Therefore, DLIR should be used cautiously for cardiovascular risk assessment. KEY POINTS: • In coronary artery calcium imaging, the implementation of deep learning image reconstructions improves image quality, by decreasing the level of image noise. • Deep learning image reconstructions systematically underestimate Agatston coronary artery calcium score. • Deep learning image reconstructions should be used cautiously in clinical routine to measure Agatston coronary artery calcium score for cardiovascular risk assessment.


Subject(s)
Coronary Artery Disease , Deep Learning , Humans , Coronary Artery Disease/diagnostic imaging , Calcium , Image Processing, Computer-Assisted/methods , Algorithms , Radiographic Image Interpretation, Computer-Assisted/methods , Radiation Dosage
SELECTION OF CITATIONS