Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 18 de 18
Filter
1.
Clin Res Cardiol ; 112(9): 1164-1174, 2023 Sep.
Article in English | MEDLINE | ID: mdl-35776144

ABSTRACT

AIM: We evaluated a decision algorithm for percutaneous coronary interventions (PCI) based on a no-stent strategy, corresponding to a combination of scoring balloon angioplasty (SCBA) and drug-coated balloon (DCB), as a first line approach. Stents were used only in unstable patients, or in case of mandatory bailout stenting (BO-stent). METHODS: From April 2019 to March 2020, 984 consecutive patients, including 1922 lesions, underwent PCI. The 12-month primary end-point was a composite of major adverse cardiac events (MACE) defined as all-cause death, nonfatal myocardial infarction, nonfatal stroke, and target lesion revascularization. Patients were classified into conventional or no-stent strategy groups according to the PCI strategy. In the no-stent strategy group, they were further classified into BO-stent or DCB-only groups. Their metal index was calculated by stent length divided by the total lesion length. RESULTS: The no-stent strategy was applied in 85% of the patients, and it was successful for 65% of them. MACE occurred in 7.1% of the study population, including 4.2% of all-cause death. Target lesion revascularization was required in 1.4%, 3.6%, and 1.5% of patients in the conventional DES, BO-stent, and DCB-only groups, respectively. MACE occurred more often in the elderly and in those treated with at least one stent (metal index greater than 0). CONCLUSIONS: The no-stent strategy, i.e., revascularization of coronary lesions by SCBA followed by DCB and with DES bailout stenting, was effective and safe at 1 year. This PCI approach was applicable on a daily practice in our cath lab. TRIAL REGISTRATION: This study was registered with clinicaltrials.gov (NCT03893396, first posted on March 28, 2019). Feasibility, safety and efficacy of percutaneous coronary interventions following a decision tree proposing a no-stent strategy in stable patients with coronary artery disease. DES: drug eluting stent; SCBA: scoring balloon angioplasty; BO-stent: at least one stent; DCB: drug coated balloon; BMS: bare metal stent; Bailout (dash lines); MACE: major adverse cardiac event.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Humans , Aged , Coronary Artery Disease/diagnosis , Coronary Artery Disease/surgery , Percutaneous Coronary Intervention/adverse effects , Prospective Studies , Treatment Outcome , Decision Trees
3.
Molecules ; 27(24)2022 Dec 13.
Article in English | MEDLINE | ID: mdl-36557975

ABSTRACT

In the last decade, microfluidic techniques have been explored in radiochemistry, and some of them have been implemented in preclinical production. However, these are not suitable and reliable for preparing different types of radiotracers or dose-on-demand production. A fully automated iMiDEV™ microfluidic radiosynthesizer has been introduced and this study is aimed at using of the iMiDEV™ radiosynthesizer with a microfluidic cassette to produce [11C]flumazenil and [11C]L-deprenyl. These two are known PET radioligands for benzodiazepine receptors and monoamine oxidase-B (MAO-B), respectively. Methods were successfully developed to produce [11C]flumazenil and [11C]L-deprenyl using [11C]methyl iodide and [11C]methyl triflate, respectively. The final products 1644 ± 504 MBq (n = 7) and 533 ± 20 MBq (n = 3) of [11C]flumazenil and [11C]L-deprenyl were produced with radiochemical purities were over 98% and the molar activity for [11C]flumazenil and [11C]L-deprenyl was 1912 ± 552 GBq/µmol, and 1463 ± 439 GBq/µmol, respectively, at the end of synthesis. All the QC tests complied with the European Pharmacopeia. Different parameters, such as solvents, bases, methylating agents, precursor concentration, and different batches of cassettes, were explored to increase the radiochemical yield. Synthesis methods were developed using 3-5 times less precursor than conventional methods. The fully automated iMiDEV™ microfluidic radiosynthesizer was successfully applied to prepare [11C]flumazenil and [11C]L-deprenyl.


Subject(s)
Positron-Emission Tomography , Selegiline , Positron-Emission Tomography/methods , Carbon , Flumazenil , Microfluidics , Carbon Radioisotopes , Radiopharmaceuticals
4.
J Am Coll Cardiol ; 78(19): 1875-1885, 2021 11 09.
Article in English | MEDLINE | ID: mdl-34736563

ABSTRACT

BACKGROUND: There is limited evidence that fractional flow reserve (FFR) is effective in guiding therapeutic strategy in multivessel coronary artery disease (CAD) beyond prespecified percutaneous coronary intervention or coronary graft surgery candidates. OBJECTIVES: The FUTURE (FUnctional Testing Underlying coronary REvascularization) trial aimed to evaluate whether a treatment strategy based on FFR was superior to a traditional strategy without FFR in the treatment of multivessel CAD. METHODS: The FUTURE trial is a prospective, randomized, open-label superiority trial. Multivessel CAD candidates were randomly assigned (1:1) to treatment strategy based on FFR in all stenotic (≥50%) coronary arteries or to a traditional strategy without FFR. In the FFR group, revascularization (percutaneous coronary intervention or surgery) was indicated for FFR ≤0.80 lesions. The primary endpoint was a composite of major adverse cardiac or cerebrovascular events at 1 year. RESULTS: The trial was stopped prematurely by the data safety and monitoring board after a safety analysis and 927 patients were enrolled. At 1-year follow-up, by intention to treat, there were no significant differences in major adverse cardiac or cerebrovascular events rates between groups (14.6% in the FFR group vs 14.4% in the control group; hazard ratio: 0.97; 95% confidence interval: 0.69-1.36; P = 0.85). The difference in all-cause mortality was nonsignificant, 3.7% in the FFR group versus 1.5% in the control group (hazard ratio: 2.34; 95% confidence interval: 0.97-5.18; P = 0.06), and this was confirmed with a 24 months' extended follow-up. FFR significantly reduced the proportion of revascularized patients, with more patients referred to exclusively medical treatment (P = 0.02). CONCLUSIONS: In patients with multivessel CAD, we did not find evidence that an FFR-guided treatment strategy reduced the risk of ischemic cardiovascular events or death at 1-year follow-up. (Functional Testing Underlying Coronary Revascularisation; NCT01881555).


Subject(s)
Coronary Artery Bypass , Coronary Artery Disease , Coronary Stenosis , Coronary Vessels , Fractional Flow Reserve, Myocardial/physiology , Percutaneous Coronary Intervention , Postoperative Complications/mortality , Aged , Coronary Angiography/methods , Coronary Artery Bypass/adverse effects , Coronary Artery Bypass/methods , Coronary Artery Disease/diagnosis , Coronary Artery Disease/mortality , Coronary Artery Disease/physiopathology , Coronary Artery Disease/surgery , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/etiology , Coronary Stenosis/surgery , Coronary Vessels/diagnostic imaging , Coronary Vessels/physiopathology , Early Termination of Clinical Trials , Female , Humans , Long Term Adverse Effects/mortality , Male , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/methods , Predictive Value of Tests , Risk Assessment/methods , Severity of Illness Index
5.
Arch Cardiovasc Dis ; 110(3): 179-187, 2017 Mar.
Article in English | MEDLINE | ID: mdl-28117244

ABSTRACT

BACKGROUND: Literature suggests that radial access is associated with higher radiation doses than femoral access. AIMS: To compare patient radiation exposure during coronary angiography (CA) and percutaneous coronary intervention (PCI) with radial versus femoral access. METHODS: RAY'ACT is a nationwide, multicentre, French survey evaluating patient radiation in interventional cardiology. Variables of patient exposure from 21,675 CAs and 17,109 PCIs performed at 44 centres during 2010 were analysed retrospectively. RESULTS: Radial access was used in 71% of CAs and 69% of PCIs. Although median fluoroscopy times were longer for radial versus femoral access (CA, 3.8 vs 3.5minutes [P<0.001]; PCI, 10.4 vs 10.1minutes [P=0.001]), the Kerma-area product (KAP) was lower with radial access (CA, 26.8 vs 28.1Gy·cm2; PCI, 55.6 vs 59.4Gy·cm2; both P=0.001). Differences in KAP remained significant in the multivariable analysis (P<0.01), and in a propensity score-matched analysis (P=0.01). A significant interaction was found between KAP and the percentage of procedures with radial access by centre (P<0.001). KAP was higher by radial versus femoral access in low-radial-volume centres, and lower in high-radial-volume centres. Radiation protection techniques, such as the use of low frame rates (7.5 frame/s), were used more frequently in high-radial-volume radial centres. CONCLUSIONS: In this multicentre study, radial access was associated with lower radiation doses to patient than femoral access in high-radial-volume centres. Provided that radioprotection methods are implemented, radial access could be associated with lower patient radiation exposure.


Subject(s)
Catheterization, Peripheral/methods , Coronary Angiography/methods , Femoral Artery , Hospitals, High-Volume , Percutaneous Coronary Intervention/methods , Radial Artery , Radiation Dosage , Radiation Exposure/prevention & control , Aged , Catheterization, Peripheral/adverse effects , Chi-Square Distribution , Coronary Angiography/adverse effects , Female , Femoral Artery/diagnostic imaging , France , Hospitals, Low-Volume , Humans , Linear Models , Logistic Models , Male , Middle Aged , Multivariate Analysis , Patient Safety , Percutaneous Coronary Intervention/adverse effects , Propensity Score , Punctures , Radial Artery/diagnostic imaging , Radiation Exposure/adverse effects , Radiation Injuries/etiology , Radiation Injuries/prevention & control , Radiation Protection , Radiography, Interventional , Retrospective Studies , Risk Assessment , Risk Factors , Time Factors
6.
J Nucl Med ; 56(12): 1876-81, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26405171

ABSTRACT

UNLABELLED: A novel PET radiotracer, Flurpiridaz F 18, has undergone phase II clinical trial evaluation as a high-resolution PET cardiac perfusion imaging agent. In a subgroup of patients imaged with this agent, we assessed the feasibility and benefit of simultaneous correction of respiratory and cardiac motion. METHODS: In 16 patients, PET imaging was performed on a 4-ring scanner in dual cardiac and respiratory gating mode. Four sets of data were reconstructed with high-definition reconstruction (HD•PET): ungated and 8-bin electrocardiography-gated images using 5-min acquisition, optimal respiratory gating (ORG)-as developed for oncologic imaging-using a narrow range of breathing amplitude around end-expiration level with 35% of the counts in a 7-min acquisition, and 4-bin respiration-gated and 8-bin electrocardiography-gated images (32 bins in total) using the 7-min acquisition (dual-gating, using all data). Motion-frozen (MF) registration algorithms were applied to electrocardiography-gated and dual-gated data, creating cardiac-MF and dual-MF images. We computed wall thickness, wall/cavity contrast, and contrast-to-noise ratio for standard, ORG, cardiac-MF, and dual-MF images to assess image quality. RESULTS: The wall/cavity contrast was similar for ungated (9.3 ± 2.9) and ORG (9.5 ± 3.2) images and improved for cardiac-MF (10.8 ± 3.6) and dual-MF images (14.8 ± 8.0) (P < 0.05). The contrast-to-noise ratio was 22.2 ± 9.1 with ungated, 24.7 ± 12.2 with ORG, 35.5 ± 12.8 with cardiac-MF, and 42.1 ± 13.2 with dual-MF images (all P < 0.05). The wall thickness was significantly decreased (P < 0.05) with dual-MF (11.6 ± 1.9 mm) compared with ungated (13.9 ± 2.8 mm), ORG (13.1 ± 2.9 mm), and cardiac-MF images (12.1 ± 2.7 mm). CONCLUSION: Dual (respiratory/cardiac)-gated perfusion imaging with Flurpiridaz F 18 is feasible and improves image resolution, contrast, and contrast-to-noise ratio when MF registration methods are applied.


Subject(s)
Heart/diagnostic imaging , Positron-Emission Tomography/methods , Pyridazines , Radiopharmaceuticals , Adult , Aged , Algorithms , Electrocardiography , Female , Gated Blood-Pool Imaging , Heart/physiology , Humans , Image Processing, Computer-Assisted , Male , Middle Aged , Myocardium/cytology , Respiratory Mechanics
7.
J Nucl Med ; 53(4): 575-83, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22419753

ABSTRACT

UNLABELLED: Whether (18)F-FDG PET can detect inflammation in the coronary arteries remains controversial. We examined (18)F-FDG uptake at the culprit sites of acute myocardial infarction (AMI) after percutaneous coronary stenting (PCS) by coregistering PET and coronary CT angiography (CTA). METHODS: Twenty nondiabetic patients with AMI (median age, 62 y; 16 men and 4 women) and 7 nondiabetic patients with stable coronary artery disease (CAD; median age, 67 y; 4 men and 3 women) underwent (18)F-FDG PET and coronary CTA 1-6 d after PCS of culprit stenoses. After a low-carbohydrate dietary preparation and more than 12 h of fasting, 480 MBq of (18)F-FDG were injected, and PET images were acquired 3 h later. Helical CTA was performed on a dual-source scanner. Stent position on attenuation-correction noncontrast CT and CTA was used to fuse PET and CTA. Two experienced readers masked to patient data independently quantified maximum target-to-background ratio (maxTBR) at each PCS site. A maxTBR greater than 2.0 was the criterion for significant uptake. RESULTS: Compared with stable CAD patients, more AMI patients exhibited a PCS site maxTBR greater than 2.0 (12/20 vs. 1/7, P = 0.04). More AMI patients were active smokers (9/20 vs. 0/7 in stable CAD, P = 0.03). After adjusting for baseline demographic differences, stent-myocardium distance, and myocardial (18)F-FDG uptake, presentation of AMI was positively associated with a PCS site maxTBR greater than 2.0 (odds ratio, 31.6; P = 0.044). Prevalence of excess myocardial (18)F-FDG uptake was similar in both populations (8/20 AMI vs. 3/7 stable CAD, P = 0.89). CONCLUSION: Systematic fusion of (18)F-FDG PET and coronary CTA demonstrated increased culprit site (18)F-FDG uptake more commonly in patients with AMI than in patients with stable CAD. However, this approach failed to detect increased signal at the culprit site in nearly half of AMI patients, highlighting the challenging nature of in vivo coronary artery plaque metabolic imaging. Nonetheless, our findings suggest that imaging of coronary artery inflammation is feasible, and further work evaluating (18)F-FDG uptake in high-risk coronary plaques prior to rupture would be of great interest.


Subject(s)
Coronary Angiography , Coronary Artery Disease/diagnosis , Coronary Vessels/metabolism , Fluorodeoxyglucose F18/metabolism , Myocardial Infarction/diagnosis , Positron-Emission Tomography , Stents , Acute Disease , Aged , Aged, 80 and over , Biological Transport , Coronary Artery Disease/metabolism , Coronary Artery Disease/therapy , Coronary Vessels/diagnostic imaging , Female , Humans , Image Processing, Computer-Assisted , Male , Middle Aged , Myocardial Infarction/metabolism , Myocardial Infarction/therapy , Skin
8.
J Nucl Med ; 53(2): 171-81, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22228795

ABSTRACT

UNLABELLED: Several models for the quantitative analysis of myocardial blood flow (MBF) at stress and rest and myocardial flow reserve (MFR) with (13)N-ammonia myocardial perfusion PET have been implemented for clinical use. We aimed to compare quantitative results obtained from 3 software tools (QPET, syngo MBF, and PMOD), which perform PET MBF quantification with either a 2-compartment model (QPET and syngo MBF) or a 1-compartment model (PMOD). METHODS: We considered 33 adenosine stress and rest (13)N-ammonia studies (22 men and 11 women). Average age was 54.5 ± 15 y, and average body mass index was 26 ± 4.2. Eighteen patients had a very low likelihood of disease, with no chest pain, normal relative perfusion results, and normal function. All data were obtained on a PET/CT scanner in list mode with CT attenuation maps. Sixteen dynamic frames were reconstructed (twelve 10-s, two 30-s, one 1-min, and one 6-min frames). Global and regional stress and rest MBF and MFR values were obtained with each tool. Left ventricular contours and input function region were obtained automatically in system QPET and syngo MBF and manually in PMOD. RESULTS: The flow values and MFR values were highly correlated among the 3 packages (R(2) ranging from 0.88 to 0.92 for global values and from 0.78 to 0.94 for regional values. Mean reference MFR values were similar for QPET, syngo MBF, and PMOD (3.39 ± 1.22, 3.41 ± 0.76, and 3.66 ± 1.19, respectively) by 1-way ANOVA (P = 0.74). The lowest MFR in very low likelihood patients in any given vascular territory was 2.25 for QPET, 2.13 for syngo MBF, and 2.23 for PMOD. CONCLUSION: Different implementations of 1- and 2-compartment models demonstrate an excellent correlation in MFR for each vascular territory, with similar mean MFR values.


Subject(s)
Ammonia , Coronary Circulation , Multimodal Imaging/methods , Positron-Emission Tomography , Rest/physiology , Stress, Physiological/physiology , Tomography, X-Ray Computed , Female , Fractional Flow Reserve, Myocardial , Humans , Linear Models , Male , Middle Aged , Myocardial Perfusion Imaging , Nitrogen Radioisotopes , Retrospective Studies , Software
9.
J Nucl Cardiol ; 19(2): 265-76, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22203445

ABSTRACT

BACKGROUND: We aimed to characterize normal limits and to determine the diagnostic accuracy for an automated quantification of 3D 82-Rubidium (Rb-82) PET/CT myocardial perfusion imaging (MPI). METHODS: We studied 125 consecutive patients undergoing Rb-82 PET/CT MPI, including patients with suspected coronary artery disease (CAD) and invasive coronary angiography, and 42 patients with a low likelihood (LLk) of CAD. Normal limits for perfusion and function were derived from LLk patients. QPET software was used to quantify perfusion abnormality at rest and stress expressed as total perfusion deficit (TPD). RESULTS: Relative perfusion databases did not differ in any of the 17 segments between males and females. The areas under the receiver operating characteristic curve for detection of CAD were 0.86 for identification of ≥50% and ≥70% stenosis. The sensitivity/specificity was 86%/86% for detecting ≥50% stenosis and 93%/77% for ≥70% stenosis, respectively. In regard to normal limits, mean rest and stress left ventricular ejection fraction (LVEF) were 67% ± 10% and 75% ± 9%, respectively. Mean transient ischemic dilation ratio was 1.06 ± 0.14 and mean increase in LVEF with stress was 7.4% ± 6.1% (95th percentile of 0%). CONCLUSION: Normal limits have been established for 3D Rb-82 PET/CT analysis with QPET software. Fully automated quantification of myocardial perfusion PET data shows high diagnostic accuracy for detecting obstructive CAD.


Subject(s)
Coronary Artery Disease/diagnosis , Imaging, Three-Dimensional/methods , Myocardial Perfusion Imaging/methods , Pattern Recognition, Automated/methods , Positron-Emission Tomography/methods , Rubidium Radioisotopes , Tomography, X-Ray Computed/methods , Aged , Coronary Angiography , Female , Humans , Image Interpretation, Computer-Assisted/methods , Male , Radiopharmaceuticals , Reference Values , Reproducibility of Results , Sensitivity and Specificity , Statistics as Topic , Subtraction Technique
10.
Med Phys ; 38(11): 6313-26, 2011 Nov.
Article in English | MEDLINE | ID: mdl-22047396

ABSTRACT

PURPOSE: The authors aimed to develop an image-based registration scheme to detect and correct patient motion in stress and rest cardiac positron emission tomography (PET)/CT images. The patient motion correction was of primary interest and the effects of patient motion with the use of flurpiridaz F 18 and (82)Rb were demonstrated. METHODS: The authors evaluated stress/rest PET myocardial perfusion imaging datasets in 30 patients (60 datasets in total, 21 male and 9 female) using a new perfusion agent (flurpiridaz F 18) (n = 16) and (82)Rb (n = 14), acquired on a Siemens Biograph-64 scanner in list mode. Stress and rest images were reconstructed into 4 ((82)Rb) or 10 (flurpiridaz F 18) dynamic frames (60 s each) using standard reconstruction (2D attenuation weighted ordered subsets expectation maximization). Patient motion correction was achieved by an image-based registration scheme optimizing a cost function using modified normalized cross-correlation that combined global and local features. For comparison, visual scoring of motion was performed on the scale of 0 to 2 (no motion, moderate motion, and large motion) by two experienced observers. RESULTS: The proposed registration technique had a 93% success rate in removing left ventricular motion, as visually assessed. The maximum detected motion extent for stress and rest were 5.2 mm and 4.9 mm for flurpiridaz F 18 perfusion and 3.0 mm and 4.3 mm for (82)Rb perfusion studies, respectively. Motion extent (maximum frame-to-frame displacement) obtained for stress and rest were (2.2 ± 1.1, 1.4 ± 0.7, 1.9 ± 1.3) mm and (2.0 ± 1.1, 1.2 ±0 .9, 1.9 ± 0.9) mm for flurpiridaz F 18 perfusion studies and (1.9 ± 0.7, 0.7 ± 0.6, 1.3 ± 0.6) mm and (2.0 ± 0.9, 0.6 ± 0.4, 1.2 ± 1.2) mm for (82)Rb perfusion studies, respectively. A visually detectable patient motion threshold was established to be ≥2.2 mm, corresponding to visual user scores of 1 and 2. After motion correction, the average increases in contrast-to-noise ratio (CNR) from all frames for larger than the motion threshold were 16.2% in stress flurpiridaz F 18 and 12.2% in rest flurpiridaz F 18 studies. The average increases in CNR were 4.6% in stress (82)Rb studies and 4.3% in rest (82)Rb studies. CONCLUSIONS: Fully automatic motion correction of dynamic PET frames can be performed accurately, potentially allowing improved image quantification of cardiac PET data.


Subject(s)
Imaging, Three-Dimensional/methods , Movement , Myocardial Perfusion Imaging/methods , Positron-Emission Tomography/methods , Pyridazines , Rubidium Radioisotopes , Stress, Physiological , Algorithms , Automation , Female , Humans , Male , Middle Aged , Rest
11.
J Nucl Cardiol ; 18(2): 259-66, 2011 Apr.
Article in English | MEDLINE | ID: mdl-21161704

ABSTRACT

BACKGROUND: PET reconstruction incorporating spatially variant 3D Point Spread Function (PSF) improves contrast and image resolution. "Cardiac Motion Frozen" (CMF) processing eliminates the influence of cardiac motion in static summed images. We have evaluated the combined use of CMF- and PSF-based reconstruction for high-resolution cardiac PET. METHODS: Static and 16-bin ECG-gated images of 20 patients referred for (18)F-FDG myocardial viability scans were obtained on a Siemens Biograph-64. CMF was applied to the gated images reconstructed with PSF. Myocardium to blood contrast, maximum left ventricle (LV) counts to defect contrast, contrast-to-noise (CNR) and wall thickness with standard reconstruction (2D-AWOSEM), PSF, ED-gated PSF, and CMF-PSF were compared. RESULTS: The measured wall thickness was 18.9 ± 5.2 mm for 2D-AWOSEM, 16.6 ± 4.5 mm for PSF, and 13.8 ± 3.9 mm for CMF-PSF reconstructed images (all P < .05). The CMF-PSF myocardium to blood and maximum LV counts to defect contrasts (5.7 ± 2.7, 10.0 ± 5.7) were higher than for 2D-AWOSEM (3.5 ± 1.4, 6.5 ± 3.1) and for PSF (3.9 ± 1.7, 7.7 ± 3.7) (CMF vs all other, P < .05). The CNR for CMF-PSF (26.3 ± 17.5) was comparable to PSF (29.1 ± 18.3), but higher than for ED-gated dataset (13.7 ± 8.8, P < .05). CONCLUSION: Combined CMF-PSF reconstruction increased myocardium to blood contrast, maximum LV counts to defect contrast and maintained equivalent noise when compared to static summed 2D-AWOSEM and PSF reconstruction.


Subject(s)
Fluorodeoxyglucose F18 , Heart/diagnostic imaging , Myocardial Perfusion Imaging/methods , Positron-Emission Tomography/methods , Radiopharmaceuticals , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Retrospective Studies
12.
J Nucl Cardiol ; 17(3): 414-26, 2010 Jun.
Article in English | MEDLINE | ID: mdl-20151238

ABSTRACT

BACKGROUND: We aimed to determine in phantom and cardiac clinical studies the impact of a new high-resolution PET image reconstruction. METHODS: A phantom with cardiac insert filled with (18)F, 14 (18)F-FDG viability studies and 15 (82)Rb perfusion studies were acquired on a Siemens Biograph-64 (4-ring). The data were reconstructed with 2D- and 3D-attenuation weighted ordered subsets expectation maximization (AWOSEM), and high-definition reconstruction (HD.PET). We calculated wall/cavity contrast, contrast-to-noise ratio (CNR), wall thickness, motion/thickening and ejection fraction. RESULTS: In the phantom study, we found an increase in defect size (up to 26%), contrast (up to 48%) and CNR (1.9) with HD.PET as compared to standard techniques. The contrast increased on HD.PET images compared to 2D- and 3D-AWOSEM for viability (14.0% +/- 4.8%) and perfusion studies (7.3% +/- 4.3%) (P < .05). Average CNR increased with HD.PET by 79.4% +/- 17.1% and 68.8% +/- 3.0% in viability and perfusion studies respectively (all P < .05). Average wall thickness with HD.PET decreased in the phantom study by 1.3 +/- 0.3 mm and the viability studies by 1.9 +/- 0.7 mm but not in the perfusion studies. The functional measurements were not significantly different for any techniques. CONCLUSIONS: We demonstrated both in phantom and patient cardiac studies that HD.PET improves image contrast, defect definition, and CNR.


Subject(s)
Heart/diagnostic imaging , Image Enhancement , Positron-Emission Tomography , Female , Fluorodeoxyglucose F18 , Humans , Image Processing, Computer-Assisted , Male , Myocardial Contraction , Phantoms, Imaging , Radiopharmaceuticals , Rubidium Radioisotopes , Stroke Volume
13.
J Cardiovasc Comput Tomogr ; 3(6): 394-400, 2009.
Article in English | MEDLINE | ID: mdl-20083060

ABSTRACT

BACKGROUND: Technical advances to minimize radiation exposure because of imaging are in accord with the "as low as reasonably achievable" principle. OBJECTIVE: We aimed to determine whether coronary calcium scoring (CCS) by multidetector CT at a tube voltage of 100 kVp yields comparable results to the standard 120-kVp protocol while reducing radiation dose. METHODS: Sixty consecutive outpatients were scanned with a dual-source CT scanner with both the120- and 100-kVp protocols. The calcium threshold was 130 Hounsfield units (HUs) for 120 kVp and 147 HU for 100 kVp, as determined from phantom data. All 100-kVp scans were scored by an experienced reader blinded to 120-kVp data. RESULTS: Image quality was comparable for 100- and 120- kVp scans. Mean Agatston scores for 100 and 120 kVp were 189 +/- 484 and 189 +/- 498 (P = 0.92), with perfect correlation (r = 1.0; P < 0.0001; 95% limits of agreement, -36 to 37; bias, 0.6). Mean coronary calcium volume scores for 100 and 120 kVp were 143 +/- 370 mm(3) and 149 +/- 392 mm(3) (P = 0.26), with perfect correlation (r = 1.0; P < 0.0001; 95% limits of agreement, -35 to 32 mm(3); bias, -1.4 mm(3)). The mean absolute difference for Agatston scores between the protocols was 16.9, with excellent agreement (kappa = 0.95; P < 0.0001). Mean effective radiation dose for the 100-kVp protocol was significantly lower (1.17 mSv versus 1.70 mSv; P < 0.0001). CONCLUSION: A reduced tube current protocol using 100 kVp gives equivalent CCS results at reduced radiation exposure compared with a standard protocol at 120 kVp.


Subject(s)
Calcinosis/diagnostic imaging , Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Radiation Dosage , Tomography, X-Ray Computed , Aged , Artifacts , Coronary Angiography/adverse effects , Coronary Angiography/instrumentation , Female , Humans , Male , Middle Aged , Phantoms, Imaging , Predictive Value of Tests , Prospective Studies , Radiation Injuries/etiology , Radiation Injuries/prevention & control , Severity of Illness Index , Tomography, X-Ray Computed/adverse effects , Tomography, X-Ray Computed/instrumentation
14.
J Cardiovasc Comput Tomogr ; 2(2): 105-14, 2008.
Article in English | MEDLINE | ID: mdl-19083930

ABSTRACT

INTRODUCTION: We aimed to characterize artifacts observed in a routine clinical coronary CT angiography (CCTA) performed by a dual-source CT (DSCT) scanner (Definition; Siemens Medical Solutions). METHODS: Studies of 167 consecutive patients referred for CCTA, performed after beta-blockade (if not contraindicated), were prospectively analyzed for artifacts with a predefined visual approach. American Heart Association coronary segments (n = 2589) were assessed in 40%-80% R-R interval phases by 2 experts for stenosis, plaque presence or composition, and presence or type of artifacts. Each segment was considered evaluable when image quality was diagnostic in at least one cardiac phase. Artifacts included motion (cardiac, respiratory, patient), phase misregistration because of varying heart beats, calcified plaque blooming or beam hardening, metal beam hardening, large patient size, and contrast timing error. RESULTS: Maximum HR (HR) during CCTA ranged from 45 to 120 beats/min (66.4 +/- 14.8 beats/min). Artifacts of some type were observed in 69 (41.3%) of 167 studies. Calcified plaque was the most common source of artifacts (14.4%), followed by misregistration (13.8%). Only 25 (1%) of 2589 coronary segments, in 6 (4%) of 167 patients were unevaluable, primarily because of calcified plaque blooming (coronary calcium score [CCS], 1112 +/- 1255]. Artifacts were associated with CCS (P = 0.002), change in HR (P = 0.01), age (P = 0.03), and body mass index (P = 0.048). The optimal phase for evaluation of all coronary arteries was 70% (mid-diastole), with a shift toward the systolic phases for HR > 70 beats/min. CONCLUSION: CCTA artifacts with DSCT were related primarily to calcified plaque and cardiac phase misregistration. When correctly recognized, the artifacts did not have a serious effect on the final interpretation.


Subject(s)
Artifacts , Coronary Angiography/statistics & numerical data , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/epidemiology , Radiographic Image Enhancement/methods , Tomography, X-Ray Computed/statistics & numerical data , Adult , Aged , Aged, 80 and over , California/epidemiology , Female , Humans , Incidence , Male , Middle Aged , Pilot Projects , Prognosis , Reproducibility of Results , Sensitivity and Specificity
15.
J Cardiovasc Comput Tomogr ; 2(5): 311-22, 2008.
Article in English | MEDLINE | ID: mdl-19083968

ABSTRACT

BACKGROUND: Strategies to reduce the radiation dose of coronary computed tomography angiography (CCTA), while maintaining diagnostic image quality, are imperative for cardiac CT. OBJECTIVE: We aimed to reduce radiation dose during helical dual-source CCTA by combining lower tube voltage, shortest possible full tube current (FTC) window, and minimal tube current outside the FTC window, and to develop a patient-based algorithm for applying these dose-reduction components. METHODS: We compared FTC at 70% of the cardiac cycle (FTC70) to a 45% to 75% window (FTC45-75) using both 100 and 120 kVp (N=118). FTC70 was used in patients with heart rates <70 beats/min, no arrhythmia, age <65 years; 100 kVp was used in patients with body mass index (BMI) <30, a low coronary calcium score (CCS), and no stents. Objective and subjective image quality were assessed. RESULTS: Compared with FTC45-75 at 120 kVp, radiation dose was reduced by 66% for FTC70 at 100 kVp (mean radiation dose: 4.4 +/- 0.9 mSv) and by 43% for FTC70 at 120 kVp. 99% of 780 segments in the FTC70 group were of diagnostic quality. Noise, signal-to-noise ratio, and contrast-to-noise ratio were comparable between FTC70 and FTC45-75 for both 100 and 120 kVp. BMI, CCS and maximal heart rate variation were predictors of image quality. Tube voltage, FTC window width, scan length, and average heart rate were predictors of radiation dose. CONCLUSIONS: A successful patient-based algorithm for radiation dose reduction during helical CCTA using DSCT has been developed and validated in clinical practice.


Subject(s)
Algorithms , Body Burden , Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Radiation Protection/methods , Tomography, Spiral Computed/methods , Aged , Female , Humans , Male , Middle Aged , Radiation Dosage , Relative Biological Effectiveness
16.
J Nucl Med ; 49(12): 1992-8, 2008 Dec.
Article in English | MEDLINE | ID: mdl-19038996

ABSTRACT

UNLABELLED: CT-based attenuation correction (AC) for myocardial perfusion PET studies is challenging because of respiratory motion. Our study aimed to compare the transmission CT (TCT)-based and CT-based AC for myocardial perfusion PET/CT images with a direct semiquantitative approach comparing differences in segmental count distribution. METHODS: Stress and rest (82)Rb PET scans from 54 consecutive patients acquired on a PET/CT scanner with dual CT-based and TCT-based AC were considered. TCT- and CT-based AC images were automatically registered to each other, and direct voxel-based and American Heart Association segment-based estimation of positive and negative changes between these scans was performed. Additionally, visual quality control (QC) of CT map alignment with PET emission data was performed by 2 expert observers, and studies with significant (>/=5 mm) misalignment were reprocessed with corrected CT alignment. RESULTS: We used the 17-segment American Heart Association model for TCT-to-CT regional change analysis in all patients and found that 4 segments on rest and 4 segments on stress scans differed more than 3% between CT- and TCT-corrected images for studies without significant misalignments (<5 mm); only 1 differed by more than 5%. In cases with significant misalignment of greater than or equal to 3% TCT-CT AC, changes were observed on 14 rest and 10 stress segments; after alignment, these differences were still seen in 13 rest segments and 11 stress segments. Visual QC revealed that 46% of rest and 54% of stress PET scans were misaligned by greater than or equal to 5 mm with the CT maps acquired during normal breathing. The range of the reported PET/CT misalignment was 0-15 mm in x, 0-16 mm in y, and 0-20 mm in z directions. The overall agreement in visual QC of PET/CT alignment between the observers was 72.2% CONCLUSION: There are significant differences between TCT and CT AC applied to cardiac PET/CT studies, which remain after alignment of CT maps to emission data.


Subject(s)
Artifacts , Coronary Artery Disease/diagnosis , Image Enhancement/methods , Positron-Emission Tomography/methods , Rubidium Radioisotopes , Tomography, X-Ray Computed/methods , Ventricular Dysfunction, Left/diagnosis , Aged , Algorithms , Coronary Artery Disease/complications , Humans , Image Interpretation, Computer-Assisted/methods , Radiopharmaceuticals , Reproducibility of Results , Sensitivity and Specificity , Subtraction Technique , Ventricular Dysfunction, Left/complications
17.
J Nucl Cardiol ; 13(6): 821-30, 2006 Nov.
Article in English | MEDLINE | ID: mdl-17174813

ABSTRACT

BACKGROUND: Positron emission tomography (PET) attenuation correction (AC) using computed tomography (CT) can be affected by respiratory motion: hi-speed CT captures 1 point of the respiratory cycle while PET emission data averages many cycles. We quantified the changes in apparent myocardial uptake due to this respiratory-induced CT attenuation mismatch. METHODS: Twenty-two patients undergoing fluorine-18 fluorodeoxyglucose (FDG) PET/CT received 3 sequential CT scans at normal resting end-inspiration (CT(INSPIR)), ending expiration (CT(EXPIR)), and at midvolume between end-expiration and end-inspiration (CT(MIDVOL)). A pneumotachometer measured absolute changes in lung volume. Seven subjects also underwent a 3-minute transmission scan with a 68Ge rotating rod source (RRS). The PET emission data set was reconstructed up to 4 times using CT(EXPIR), CT(INSPIR), CT(MIDVOL), and RRS AC maps. Relative heart position and cardiac uptake was measured for each CT attenuation correction. RESULTS: Respiratory motion produced marked changes in global and regional myocardial uptake. Changes were large in the lateral and anterior regions at the lung-soft tissue interface (up to 30% using CT(INSPIR) compared to CT(EXPIR) for AC) and smaller in the septal region (10% or less). Data corrected with CT(EXPIR) agreed best with the RRS. CONCLUSION: Respiratory effects can introduce large inhomogeneities in apparent myocardial uptake when CT is used for attenuation correction.


Subject(s)
Fluorodeoxyglucose F18/pharmacokinetics , Movement/physiology , Myocardium/metabolism , Positron-Emission Tomography/methods , Respiratory Mechanics/physiology , Tomography, X-Ray Computed/methods , Adult , Artifacts , Heart/diagnostic imaging , Humans , Radiopharmaceuticals/pharmacokinetics , Reproducibility of Results , Sensitivity and Specificity , Subtraction Technique
18.
Acta Cardiol ; 58(1): 23-9, 2003 Feb.
Article in English | MEDLINE | ID: mdl-12625491

ABSTRACT

OBJECTIVE: Rates of coronary angiography (CA) after myocardial infarction (MI) vary widely between institutions. Furthermore, the indications for CA are often in conflict with recognized guidelines. The present study sought to determine the characteristics and the one-year mortality in patients with MI, regardless of age and hospital facilities, according to the use of CA after MI. METHODS AND RESULTS: Data were prospectively collected in all patients with MI admitted to all hospitals in three departments in the Rhône-Alpes region. Among 2493 patients, 1117 (45%) underwent CA. In multivariate analysis, CA rate was lower with increasing age, female sex, in patients with comorbidity or heart failure. CA was performed in 49% of patients admitted to hospitals with on-site CA vs. 32% in hospitals without on-site CA (OR: 3.54, after adjustment for patients' characteristics). One-year mortality rate was 6.5% for the CA group and 36.9% for the no-CA group. In multivariate analysis, age, history of angina pectoris, presence of Q waves, Killip class at admission II, III, or IV and CPK ratio > or = 9 were significant predictors of a higher one-year mortality, but performance of CA did not significantly influence it: RR: 0.79 (95% CI 0.58 to 1.07). CONCLUSIONS: Among patients with MI in a large unselected cohort in a French region, the one-year mortality was significantly lower in those referred for angiography. However, after correction for the confounding effects of simple baseline clinical indicators of risk, this apparent benefit reflected the fact that angiography was performed in those at lowest risk.


Subject(s)
Coronary Angiography/statistics & numerical data , Myocardial Infarction/diagnostic imaging , Myocardial Infarction/mortality , Adult , Aged , Cardiology Service, Hospital/statistics & numerical data , Female , France/epidemiology , Humans , Male , Middle Aged , Multivariate Analysis , Myocardial Infarction/therapy , Prospective Studies , Risk Factors , Survival Analysis , Survival Rate , Thrombolytic Therapy/statistics & numerical data
SELECTION OF CITATIONS
SEARCH DETAIL
...