Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Rev Lett ; 126(24): 241301, 2021 Jun 18.
Article in English | MEDLINE | ID: mdl-34213923

ABSTRACT

Precision measurements are reported of the cross-spectrum of rotationally induced differential position displacements in a pair of colocated 39 m long, high-power Michelson interferometers. One arm of each interferometer is bent 90° near its midpoint to obtain sensitivity to rotations about an axis normal to the plane of the instrument. The instrument achieves quantum-limited sensing of spatially correlated signals in a broad frequency band extending beyond the 3.9-MHz inverse light travel time of the apparatus. For stationary signals with bandwidth Δf>10 kHz, the sensitivity to rotation-induced strain h of classical or exotic origin surpasses CSD_{δh}

2.
Appl Opt ; 59(25): 7726-7733, 2020 Sep 01.
Article in English | MEDLINE | ID: mdl-32902475

ABSTRACT

This paper presents the simulation and calibration of a Fourier transform spectrometer (FTS) developed to measure the spectrum of radiation sources between 50 GHz and 330 GHz, such as the cosmic microwave background. The recorded signal is modified from the ideal by properties of the interferometer and the detection system. We have developed a ray-trace-based simulation with which we can model these effects. The model can be verified with measurements and used to understand the instrument's systematic effects and to design new optimized configurations. The optimization comprises parameters of the design, such as large étendu, maximal spectral resolution, compact size, operational simplicity, and light weight, that conflict and need to be balanced. The numerical simulation consists of two parts: time-stream signal analysis and a ray-trace-based simulation that includes polarization and path length calculations and can account for the effects of beam loss and change of focus as the delay-generating mirror travels on its path. The simulation can study the coherence level and frequency resolution of the FTS instrument. While not exercised in this study, the simulation also can be used to study the effect of mirror figure and polarizer non-idealities, walk-off rays in the beam due to the large étendu, as well as misalignment of optical elements. We then present the comparison between simulations of a spectrally unresolved source and measurements by the FTS.

3.
Appl Opt ; 58(23): 6257-6267, 2019 Aug 10.
Article in English | MEDLINE | ID: mdl-31503767

ABSTRACT

We have constructed a Fourier-transform spectrometer (FTS) operating between 50 GHz and 330 GHz with minimum volume (355×260×64 mm) and weight (5.9 kg) while maximizing optical throughput (100 mm2 sr) and optimizing the spectral resolution (4 GHz). This FTS is designed as a polarizing Martin-Puplett interferometer with unobstructed input and output in which both input polarizations undergo interference. The instrument construction is simple with mirrors milled on the box walls and one motorized stage as the single moving element. We characterize the performance of the FTS, compare the measurements to an optical simulation, and discuss features that relate to details of the FTS design. The simulation is also used to determine the tolerance of optical alignments for the required specifications. We detail the FTS mechanical design and provide the control software as well as the analysis code online.

4.
Phys Rev Lett ; 117(11): 111102, 2016 Sep 09.
Article in English | MEDLINE | ID: mdl-27661676

ABSTRACT

Measurements are reported of the cross-correlation of spectra of differential position signals from the Fermilab Holometer, a pair of colocated 39 m long, high power Michelson interferometers with flat broadband frequency response in the MHz range. The instrument obtains sensitivity to high frequency correlated signals far exceeding any previous measurement in a broad frequency band extending beyond the 3.8 MHz inverse light-crossing time of the apparatus. The dominant but uncorrelated shot noise is averaged down over 2×10^{8} independent spectral measurements with 381 Hz frequency resolution to obtain 2.1×10^{-20}m/sqrt[Hz] sensitivity to stationary signals. For signal bandwidths Δf>11 kHz, the sensitivity to strain h or shear power spectral density of classical or exotic origin surpasses a milestone PSD_{δh}

SELECTION OF CITATIONS
SEARCH DETAIL
...