Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
ACS Omega ; 9(1): 1858-1869, 2024 Jan 09.
Article in English | MEDLINE | ID: mdl-38222597

ABSTRACT

A search for novel sources of biologically active compounds is at the top of the agenda for biomedical technologies. Natural humic substances (HSs) contain a large variety of different chemotypes, such as condensed tannins, hydrolyzable tannins, terpenoids, lignins, etc. The goal of this work was to develop an efficient separation technique based on solid-phase extraction (SPE) for the isolation of narrow fractions of HS with higher biological activity compared to the initial material. We used lignite humic acid as the parent humic material, which showed moderate inhibition activity toward beta-lactamase TEM 1 and antioxidant activity. We applied two different SPE techniques: the first one was based on a gradient elution with water/methanol mixtures of the humic material sorbed at pH 2, and the second one implied separation by a difference in the pKa value by the use of sequential sorption of HS at pH from 8 to 3. SPE cartridges Bond Elute PPL (Agilent) were used in the fractionation experiments. The first and second techniques yielded 9 and 7 fractions, respectively. All fractions were characterized using high-resolution mass spectrometry and biological assays, including the determination of beta-lactamase (TEM 1) inhibition activity and antioxidant activity. The acidity-based separation technique demonstrated substantial advantages: it enabled the isolation of components, outcompeting the initial material at the first step of separation (sorption at pH 8). It showed moderate orthogonality in separation with regard to the polarity-based technique. Good perspectives are shown for developing a 2D separation scheme using a combination of polarity and acidity-based approaches to reduce structural heterogeneity of the narrow fractions of HS.

2.
Biomedicines ; 9(12)2021 Nov 29.
Article in English | MEDLINE | ID: mdl-34944604

ABSTRACT

Natural products (e.g., polyphenols) have been used as biologically active compounds for centuries. Still, the mechanisms of biological activity of these multicomponent systems are poorly understood due to a lack of appropriate experimental techniques. The method of tritium thermal bombardment allows for non-selective labeling and tracking of all components of complex natural systems. In this study, we applied it to label two well-characterized polyphenolic compounds, peat fulvic acid (FA-Vi18) and oxidized lignin derivative (BP-Cx-1), of predominantly hydrophilic and hydrophobic character, respectively. The identity of the labeled samples was confirmed using size exclusion chromatography. Using ultra-high resolution Fourier transform ion cyclotron resonance mass spectrometry (FT ICR MS), key differences in the molecular composition of BP-Cx-1 and FA-Vi18 were revealed. The labeled samples ([3H]-FA-Vi18 (10 mg/kg) and [3H]-BP-Cx-1 (100 mg/kg)) were administered to female BALB/c mice intravenously (i.v.) and orally. The label distribution was assessed in blood, liver, kidneys, brain, spleen, thymus, ovaries, and heart using liquid scintillation counting. Tritium label was found in all organs studied at different concentrations. For the fulvic acid sample, the largest accumulation was observed in the kidney (Cmax 28.5 mg/kg and 5.6 mg/kg, respectively) for both routes. The organs of preferential accumulation of the lignin derivative were the liver (Cmax accounted for 396.7 and 16.13 mg/kg for i.v. and p.o. routes, respectively) and kidney (Cmax accounted for 343.3 and 17.73 mg/kg for i.v. and p.o. routes, respectively). Our results demonstrate that using the tritium labeling technique enabled successful pharmacokinetic studies on polyphenolic drugs with very different molecular compositions. It proved to be efficient for tissue distribution studies. It was also shown that the dosage of the polyphenolic drug might be lower than 10 mg/kg due to the sensitivity of the 3H detection technique.

SELECTION OF CITATIONS
SEARCH DETAIL
...