Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Surg Endosc ; 37(8): 6185-6196, 2023 08.
Article in English | MEDLINE | ID: mdl-37165173

ABSTRACT

BACKGROUND: Gastrectomy with extended (D2) lymphadenectomy is considered standard of care for gastric cancer to provide the best possible outcomes and pathologic staging. However, D2 gastrectomy is a technically demanding operation and reported to be associated with increased complications and mortality. Application of sentinel lymph node (SLN) concept in gastric cancer has the potential to reduce patient morbidity; however, SLN techniques are not established for gastrectomy, in part due to lack of practical tracers. An effective and convenient tracer with enhanced SLN accumulation is critically needed. METHODS: Mannose-labelled magnetic tracer 'FerroTrace' and fluorescent dye indocyanine green (ICG) were injected laparoscopically into the stomach submucosa of 8 healthy swine under general anaesthesia. Intraoperative fluorescence imaging was used to highlight draining lymphatic pathways containing ICG, while preoperative T2-weighted MRI and ex vivo magnetometer probe measurements were used to identify nodes containing FerroTrace. Lymphadenectomy was performed either robotically (n = 2) or via laparotomy (n = 6). RESULTS: Mixing ICG and FerroTrace ensured concurrence of fluorescent and magnetic signals in SLNs. An initial trial with robotic dissection removed all magnetic LNs (n = 4). In the subsequent laparotomy study that targeted all ICG-LNs based on intraoperative fluorescence imaging, dissection removed an average of 4.7 ± 1.2 fluorescent, and 2.0 ± 1.3 magnetic LNs per animal. Both MRI and magnetometer detected 100% of SLNs (n = 7). FerroTrace demonstrated high specificity to SLNs, which contained 76 ± 30% of total lymphotropic iron, and 88 ± 20 % of the overall magnetometer signal. CONCLUSIONS: Through utilisation of this dual tracer approach, SLNs were identified via preoperative MRI, visualised intraoperatively with fluorescence imaging, and confirmed with a magnetometer. This combination pairs the sensitivity of ICG with SLN-specific FerroTrace and can be used for reliable SLN detection in gastric cancer, with potential applications in neoadjuvant therapy.


Subject(s)
Magnetite Nanoparticles , Sentinel Lymph Node , Stomach Neoplasms , Animals , Swine , Sentinel Lymph Node/diagnostic imaging , Sentinel Lymph Node/surgery , Sentinel Lymph Node/pathology , Indocyanine Green , Sentinel Lymph Node Biopsy/methods , Mannose , Stomach Neoplasms/diagnostic imaging , Stomach Neoplasms/surgery , Stomach Neoplasms/pathology , Coloring Agents , Lymph Node Excision , Fluorescent Dyes , Lymph Nodes/diagnostic imaging , Lymph Nodes/surgery , Lymph Nodes/pathology
2.
Small ; 19(21): e2204956, 2023 05.
Article in English | MEDLINE | ID: mdl-36840671

ABSTRACT

Accurate delineation of gross tumor volumes remains a barrier to radiotherapy dose escalation and boost dosing in the treatment of solid tumors, such as prostate cancer. Magnetic resonance imaging (MRI) of tumor targets has the power to enable focal dose boosting, particularly when combined with technological advances such as MRI-linear accelerator. Fibroblast activation protein (FAP) is overexpressed in stromal components of >90% of epithelial carcinomas. Herein, the authors compare targeted MRI of prostate specific membrane antigen (PSMA) with FAP in the delineation of orthotopic prostate tumors. Control, FAP, and PSMA-targeting iron oxide nanoparticles were prepared with modification of a lymphotropic MRI agent (FerroTrace, Ferronova). Mice with orthotopic LNCaP tumors underwent MRI 24 h after intravenous injection of nanoparticles. FAP and PSMA nanoparticles produced contrast enhancement on MRI when compared to control nanoparticles. FAP-targeted MRI increased the proportion of tumor contrast-enhancing black pixels by 13%, compared to PSMA. Analysis of changes in R2 values between healthy prostates and LNCaP tumors indicated an increase in contrast-enhancing pixels in the tumor border of 15% when targeting FAP, compared to PSMA. This study demonstrates the preclinical feasibility of PSMA and FAP-targeted MRI which can enable targeted image-guided focal therapy of localized prostate cancer.


Subject(s)
Nanoparticles , Prostatic Neoplasms , Male , Humans , Animals , Mice , Prostate , Magnetic Resonance Imaging , Fibroblasts
3.
Nanoscale ; 15(3): 1236-1247, 2023 Jan 19.
Article in English | MEDLINE | ID: mdl-36541661

ABSTRACT

Immuno-specific enrichment of extracellular vesicles (EVs) can provide important information into cellular pathways underpinning various pathologies and for non-invasive diagnostics, including mass spectrometry-based analyses. Herein, we report an optimised protocol for immuno-magnetic enrichment of specific EV subtypes and their subsequent processing with liquid chromatography-tandem mass spectrometry (LC-MS/MS). Specifically, we conjugated placental alkaline phosphatase (PLAP) antibodies to magnetic iron oxide nanowires (NWs) derived from bacterial biofilms and demonstrated the utility of this approach by enriching placenta-specific EVs (containing PLAP) from cell culture media. We demonstrate efficient PLAP+ve EV enrichment for both NW-PLAP and Dynabeads™-PLAP, with high PLAP protein recovery (83.7 ± 8.9% and 83.2 ± 5.9%, respectively), high particle-to-protein ratio (7.5 ± 0.7 × 109 and 7.1 ± 1.2 × 109, respectively), and low non-specific binding of non-target EVs (7 ± 3.2% and 5.4 ± 2.2%, respectively). Furthermore, our optimized EV enrichment and processing approach identified 2518 and 2545 protein groups with LC-MS/MS for NW-PLAP and Dynabead™-PLAP, respectively, with excellent reproducibility (Pearson correlation 0.986 and 0.988). These findings demonstrate that naturally occurring iron oxide NWs have comparable performance to current gold standard immune-magnetic beads. The optimized immuno-specific EV enrichment for LC-MS/MS method provides a low-cost and highly-scalable yet efficient, high-throughput approach for quality EV proteomic studies.


Subject(s)
Extracellular Vesicles , Nanowires , Female , Pregnancy , Humans , Chromatography, Liquid/methods , Proteomics/methods , Reproducibility of Results , Tandem Mass Spectrometry , Placenta , Extracellular Vesicles/chemistry , Proteins/analysis
4.
Head Neck ; 44(12): 2696-2707, 2022 12.
Article in English | MEDLINE | ID: mdl-36082404

ABSTRACT

BACKGROUND: Sentinel lymph node biopsy (SLNB) is a staging procedure dependent on accurate mapping of draining lymphatics via tracers. Robot-assisted SLNB enables access to multiple neck levels with a single incision and intraoperative fluorescence guidance to the SLN. METHODS: Lymphatic mapping in swine was done using a magnetic tracer and fluorescent dye, injected into the tongue. MRI preoperatively mapped lymphatic spread of the magnetic tracer. Dissection was performed using a da Vinci Xi robot guided by fluorescence-imaging of the dye. RESULTS: Robot-assisted SLNB was successfully performed in all animals (n = 5). A novel MRI protocol differentiated SLNs (n = 6) from lower echelon nodes (n = 11) based on flow progression. Fluorescence imaging provided valuable intraoperative guidance and correlated with magnetic-positive nodes. CONCLUSIONS: This study demonstrates preclinical feasibility of a robot-assisted approach to SLNB using magnetic and fluorescent tracers in the head and neck, enabling both preoperative mapping and intraoperative guidance.


Subject(s)
Robotics , Sentinel Lymph Node Biopsy , Animals , Swine , Sentinel Lymph Node Biopsy/methods , Fluorescence , Feasibility Studies , Indocyanine Green , Fluorescent Dyes , Lymph Nodes/diagnostic imaging , Lymph Nodes/surgery , Lymph Nodes/pathology
5.
Nanomedicine ; 42: 102546, 2022 06.
Article in English | MEDLINE | ID: mdl-35278683

ABSTRACT

Sentinel lymph node biopsy in cancers of the head and neck offers demonstrated clinical and diagnostic value, but adoption is limited by concerns about the detrimental consequence to survival of false negative results in a highly curable setting. The aim of this study was to demonstrate potential to overcome this via application of a novel mannose-labeled magnetic iron oxide tracer. In a large animal model, preoperative imaging and intraoperative magnetometer detection were used to identify magnetic lymph nodes. Iron quantification mapped the distribution of tracer within lymphatic levels. Over a 4-week test period, uptake of magnetic tracer in lymph nodes increased in a linear-like fashion, with a substantial percentage of accumulated iron (83%) being retained in the sentinel node. This result indicates a high affinity of mannose-labeled particles to the sentinel node, while providing a means for the magnetometer probe to indicate node status based on intraoperative signal.


Subject(s)
Magnetite Nanoparticles , Sentinel Lymph Node , Animals , Iron , Lymph Nodes , Magnetic Phenomena , Mannose , Sentinel Lymph Node/diagnostic imaging , Sentinel Lymph Node/surgery , Sentinel Lymph Node Biopsy/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...