Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-38903962

ABSTRACT

Objectives: For early gastrointestinal lesions, size is an important factor in the selection of treatment. Virtual scale endoscope (VSE) is a newly developed endoscope that can measure size more accurately than visual measurement. This study aimed to investigate whether VSE measurement is accurate for early gastrointestinal lesions of various sizes and morphologies. Methods: This study prospectively enrolled patients with early gastrointestinal lesions ≤20 mm in size visually. Lesion sizes were measured in the gastrointestinal tract visually, on endoscopic resection specimens with VSE, and finally on endoscopic resection specimens using a ruler. The primary endpoint was the normalized difference (ND) of VSE measurement. The secondary endpoints were the ND of visual measurement and the variation between NDs of VSE and visual measurements. ND was calculated as (100 × [measured size - true size] / true size) (%). True size was defined as size measured using a ruler. Results: This study included 60 lesions from April 2022 to December 2022, with 20 each in the esophagus, stomach, and colon. The lesion size was 14.0 ± 6.3 mm (mean ± standard deviation). Morphologies were protruded, slightly elevated, and flat or slightly depressed type in 8, 24, and 28 lesions, respectively. The primary endpoint was 0.3 ± 8.8%. In the secondary endpoints, the ND of visual measurement was -1.7 ± 29.3%, and the variability was significantly smaller in the ND of VSE measurement than in that of visual measurement (p < 0.001, F-test). Conclusions: VSE measurement is accurate for early gastrointestinal lesions of various sizes and morphologies.

3.
Dig Endosc ; 36(4): 455-462, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37572330

ABSTRACT

OBJECTIVES: The resection of vertical margin-negative submucosally invasive colorectal cancer (CRC) relies on the pathological risk assessment of lymph node metastasis. However, no large-scale study has clarified the endoscopic resection (ER) outcome for submucosally invasive CRC, focusing on the vertical margin status. This retrospective study aimed to examine vertical margin involvement in ER for submucosally invasive CRC and explore the treatment consequences associated with vertical margin status. METHODS: We analyzed 395 submucosally invasive CRC cases in 389 patients who underwent ER at our hospital between 2008 and 2020. The presence of residual tumors and simultaneous lymph node metastasis in patients who underwent additional surgery was assessed and compared between the vertical incomplete ER and the vertical margin-negative groups. RESULTS: Among the patients, 270 were men, with a median age of 69 years. The vertical incomplete ER rate was 21.5%, with positive vertical margins and unclear vertical margins identified in 12.2% and 9.3% of the cases, respectively. Among 154 patients who underwent additional surgery after ER, the vertical incomplete ER group had a significantly higher residual tumor rate than the vertical margin-negative group (P = 0.001). The vertical incomplete ER group had a significantly higher lymph node metastasis rate than the vertical margin-negative group (P = 0.029). CONCLUSION: This study clarified the substantial risk of vertical incomplete ER in submucosally invasive CRC and revealed the high risk of residual tumor and lymph node metastasis in vertical incomplete ER for submucosal CRC.


Subject(s)
Colorectal Neoplasms , Male , Humans , Aged , Female , Lymphatic Metastasis , Retrospective Studies , Neoplasm, Residual/surgery , Risk Assessment , Colorectal Neoplasms/surgery , Colorectal Neoplasms/pathology , Risk Factors
4.
World J Gastroenterol ; 29(23): 3668-3677, 2023 Jun 21.
Article in English | MEDLINE | ID: mdl-37398881

ABSTRACT

BACKGROUND: Endoscopic resection (ER) with bipolar snare, in which the electric current only passes through the tissue between the device's two electrodes, is a prominent method used to prevent perforation due to electricity potentially. ER using bipolar snare with or without submucosal injection enabled safe resection of colorectal lesions measuring 10-15 mm in an ex vivo porcine model. ER with bipolar snare is expected to have good treatment outcomes in 10-15 mm colorectal lesions, with high safety even without submucosal injection. However, no clinical reports have compared treatment outcomes with and without submucosal injection. AIM: To compare the treatment outcomes of bipolar polypectomy with hot snare polypectomy (HSP) to those with endoscopic mucosal resection (EMR). METHODS: In this single-centre retrospective study, we enrolled 10-15 mm nonpedunculated colorectal lesions (565 Lesions in 463 patients) diagnosed as type 2A based on the Japan Narrow-band Imaging Expert Team classification, resected by either HSP or EMR between January 2018 and June 2021 at the National Cancer Center Hospital East. Lesions were divided into HSP and EMR groups, and propensity score matching was performed. In the matched cohort, en bloc and R0 resection rates and adverse events were compared between the two groups. RESULTS: Of the 565 lesions in 463 patients, 117 lesions each in the HSP and EMR groups were selected after propensity score matching. In the original cohort, there was a significant difference in antithrombotic drug use (P < 0.05), lesion size (P < 0.01), location (P < 0.01), and macroscopic type (P < 0.05) between the HSP and EMR groups. In the matched cohort, the en bloc resection rates were comparable between both groups [93.2% (109/117) vs 92.3% (108/117), P = 0.81], and there was no significant difference in the R0 resection rate [77.8% (91/117) vs 80.3% (94/117), P = 0.64]. The incidence of delayed bleeding was similar in both groups [1.7% (2/117)]. Perforation occurred in the EMR group [0.9% (1/117)] but not in the HSP group. CONCLUSION: Using bipolar snare, ER of nonpedunculated 10-15 mm colorectal lesions may be performed safely and effectively, even without submucosal injection.


Subject(s)
Colonic Polyps , Colorectal Neoplasms , Endoscopic Mucosal Resection , Animals , Swine , Colonoscopy/adverse effects , Colonoscopy/methods , Endoscopic Mucosal Resection/adverse effects , Endoscopic Mucosal Resection/methods , Propensity Score , Retrospective Studies , Colorectal Neoplasms/surgery , Colorectal Neoplasms/etiology , Colonic Polyps/pathology
5.
Cancer Med ; 12(15): 15809-15819, 2023 08.
Article in English | MEDLINE | ID: mdl-37329213

ABSTRACT

BACKGROUND: Hypoxic microenvironment is prominent in advanced esophageal squamous cell carcinoma (ESCC). However, it is unclear whether ESCC becomes hypoxic when it remains in the mucosal layer or as it invades the submucosal layer. We aimed to investigate whether intramucosal (Tis-T1a) or submucosal invasive (T1b) ESCC becomes hypoxic using endoscopic submucosal dissection samples. METHODS: We evaluated the expression of hypoxia markers including hypoxia inducible factor 1α (HIF-1α), carbonic anhydrase IX (CAIX), and glucose transporter 1 (GLUT1) by H-score and vessel density by microvessel count (MVC) and microvessel density (MVD) for CD31 and α-smooth muscle actin (α-SMA) with immunohistochemical staining (n = 109). Further, we quantified oxygen saturation (StO2 ) with oxygen saturation endoscopic imaging (OXEI) (n = 16) and compared them to non-neoplasia controls, Tis-T1a, and T1b. RESULTS: In Tis-T1a, cccIX (13.0 vs. 0.290, p < 0.001) and GLUT1 (199 vs. 37.6, p < 0.001) were significantly increased. Similarly, median MVC (22.7/mm2 vs. 14.2/mm2 , p < 0.001) and MVD (0.991% vs. 0.478%, p < 0.001) were markedly augmented. Additionally, in T1b, the mean expression of HIF-1α (16.0 vs. 4.95, p < 0.001), CAIX (15.7 vs. 0.290, p < 0.001), and GLUT1 (177 vs. 37.6, p < 0.001) were significantly heightened, and median MVC (24.8/mm2 vs. 14.2/mm2 , p < 0.001) and MVD (1.51% vs. 0.478%, p < 0.001) were markedly higher. Furthermore, OXEI revealed that median StO2 was significantly lower in T1b than in non-neoplasia (54% vs. 61.5%, p = 0.00131) and tended to be lower in T1b than in Tis-T1a (54% vs. 62%, p = 0.0606). CONCLUSION: These results suggest that ESCC becomes hypoxic even at an early stage, and is especially prominent in T1b.


Subject(s)
Esophageal Neoplasms , Esophageal Squamous Cell Carcinoma , Humans , Esophageal Neoplasms/diagnostic imaging , Esophageal Neoplasms/pathology , Immunohistochemistry , Glucose Transporter Type 1 , Oxygen Saturation , Hypoxia , Hypoxia-Inducible Factor 1, alpha Subunit , Cell Hypoxia , Tumor Microenvironment
6.
J Gastroenterol ; 58(8): 741-750, 2023 08.
Article in English | MEDLINE | ID: mdl-37256409

ABSTRACT

BACKGROUND: Precise area diagnosis of early gastric cancer (EGC) is critical for reliable endoscopic resection. Computer-aided diagnosis (CAD) shows strong potential for detecting EGC and reducing cancer-care disparities caused by differences in endoscopists' skills. To be used in clinical practice, CAD should enable both the detection and the demarcation of lesions. This study proposes a scheme for the detection and delineation of EGC under white-light endoscopy and validates its performance using 1-year consecutive cases. METHODS: Only 300 endoscopic images randomly selected from 68 consecutive cases were used for training a convolutional neural network. All cases were treated with endoscopic submucosal dissection, enabling the accumulation of a training dataset in which the extent of lesions was precisely determined. For validation, 462 cancer images and 396 normal images from 137 consecutive cases were used. From the validation results, 38 randomly selected images were compared with those delineated by six endoscopists. RESULTS: Successful detections of EGC in 387 cancer images (83.8%) and the absence of lesions in 307 normal images (77.5%) were achieved. Positive and negative predictive values were 81.3% and 80.4%, respectively. Successful detection was achieved in 130 cases (94.9%). We achieved precise demarcation of EGC with a mean intersection over union of 66.5%, showing the extent of lesions with a smooth boundary; the results were comparable to those achieved by specialists. CONCLUSIONS: Our scheme, validated using 1-year consecutive cases, shows potential for demarcating EGC. Its performance matched that of specialists; it might therefore be suitable for clinical use in the future.


Subject(s)
Endoscopic Mucosal Resection , Stomach Neoplasms , Humans , Stomach Neoplasms/diagnostic imaging , Stomach Neoplasms/surgery , Gastroscopy/methods , Predictive Value of Tests , Endoscopic Mucosal Resection/methods , Computers , Early Detection of Cancer/methods
7.
J Cancer Res Clin Oncol ; 149(9): 6467-6477, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36773090

ABSTRACT

PURPOSE: The pathological diagnosis of surgically resected gastric cancer involves both a macroscopic diagnosis by gross observation and a microscopic diagnosis by microscopy. Macroscopic diagnosis determines the location and stage of the disease and the involvement of other organs and surgical margin. Lesion recognition is, thus, an important diagnostic step that requires a skilled pathologist. Nonetheless, artificial intelligence (AI) technologies could allow even inexperienced doctors and laboratory technicians to examine surgically resected specimens without the need for pathologists. However, organ imaging conditions vary across hospitals, and an AI algorithm created in one setting may not work properly in another. Thus, we identified and standardized factors affecting the quality of pathological macroscopic images, which could further affect lesion identification using AI. METHODS: We examined necessary image standardization for developing cancer detection AI for surgically resected gastric cancer by changing the following imaging conditions: focus, resolution, brightness, and contrast. RESULTS: Regarding focus, brightness, and contrast, the farther away the test data were from the training macro-image, the less likely the inference was to be correct. Little change was observed for resolution, even with differing conditions for the training and test data. Regarding focus, brightness, and contrast, there were conditions appropriate for AI. Contrast, in particular, was far from the conditions appropriate for humans. CONCLUSION: Standardizing focus, brightness, and contrast is important in the development of AI methodologies for lesion detection in surgically resected gastric cancer. This standardization is essential for AI to be implemented across hospitals.


Subject(s)
Artificial Intelligence , Stomach Neoplasms , Humans , Stomach Neoplasms/diagnostic imaging , Stomach Neoplasms/surgery , Algorithms , Hospitals , Margins of Excision
SELECTION OF CITATIONS
SEARCH DETAIL
...