Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
World J Pediatr Congenit Heart Surg ; 15(1): 109-111, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37750506

ABSTRACT

We describe the perventricular device closure of a large mid-muscular ventricular septal defect (VSD) in a 2.9 kg infant born with hypoplastic aortic arch and VSD using an Occlutech perimembranous occluder. In this case, the anatomy required a short low-profile device and hence a perimembranous occluder was used. To our knowledge, this is the first described use of this device for hybrid closure of a muscular VSD and the application of this technique in a patient <3 kg.


Subject(s)
Heart Septal Defects, Ventricular , Septal Occluder Device , Infant , Humans , Treatment Outcome , Aorta, Thoracic/surgery , Cardiac Catheterization/methods , Heart Septal Defects, Ventricular/diagnostic imaging , Heart Septal Defects, Ventricular/surgery
2.
J Magn Reson Imaging ; 2023 Oct 19.
Article in English | MEDLINE | ID: mdl-37855630

ABSTRACT

BACKGROUND: Recent advances in hardware and software permit the use of cardiac MRI of late gestation fetuses, however there is a paucity of MRI-based reference values. PURPOSE: To provide initial data on fetal cardiac MRI-derived cardiac dimensions, volumes, ventricular function, and left ventricular longitudinal strain in healthy developing fetuses >30 weeks gestational age. STUDY TYPE: Prospective. POPULATION: Twenty-five third trimester (34 ± 1 weeks, range of 32-37 weeks gestation) women with healthy developing fetuses. FIELD STRENGTH/SEQUENCE: Studies were performed at 1.5 T and 3 T. Cardiac synchronization was achieved with a Doppler ultrasound device. The protocol included T2 single shot turbo spin echo stacks for fetal weight and ultrasound probe positioning, and multiplanar multi-slice cine balanced steady state free precession gradient echo sequences. ASSESSMENT: Primary analyses were performed by a single observer. Weight indexed right ventricular (RV) and left ventricular (LV) volumes and function were calculated from short axis (SAX) stacks. Cardiac dimensions were calculated from the four-chamber and SAX stacks. Single plane LV longitudinal strain was calculated from the four-chamber stack. Interobserver variability was assessed in 10 participants. Cardiac MRI values were compared against available published normative fetal echocardiogram data using z-scores. STATISTICAL TESTS: Mean and SDs were calculated for baseline maternal/fetal demographics, cardiac dimensions, volumes, ventricular function, and left ventricular longitudinal strain. Bland-Altman and intraclass correlation coefficient analysis was performed to test interobserver variability. RESULTS: The mean gestational age was 34 ± 1.4 weeks. The mean RV and LV end diastolic volumes were 3.1 ± 0.6 mL/kg and 2.4 ± 0.5 mL/kg respectively. The mean RV cardiac output was 198 ± 49 mL/min/kg while the mean LV cardiac output was 173 ± 43 mL/min/kg. DATA CONCLUSION: This paper reports initial reference values obtained by cardiac MRI in healthy developing third trimester fetuses. MRI generally resulted in slightly larger indexed values (by z-score) compared to reports in literature using fetal echocardiography. EVIDENCE LEVEL: 1 TECHNICAL EFFICACY: Stage 2.

3.
Cureus ; 15(3): e36093, 2023 Mar.
Article in English | MEDLINE | ID: mdl-37065296

ABSTRACT

Introduction Coronavirus disease 2019 (COVID-19) is known to cause cardiac abnormalities in adults. Cardiac abnormalities are well-described in multisystem inflammatory syndrome in children, but effects in children with acute COVID-19 are less understood. In this multicenter study, we assessed the cardiac effects of acute COVID-19 among hospitalized children (<21 years) admitted to three large healthcare systems in New York City. Methods We performed a retrospective observational study. We examined electrocardiograms, echocardiograms, troponin, or B-type natriuretic peptides. Results Of 317 admitted patients, 131 (41%) underwent cardiac testing with 56 (43%) demonstrating cardiac abnormalities. Electrocardiogram abnormalities were the most common (46/117 patients (39%)), including repolarization abnormalities and QT prolongation. Elevated troponin occurred in 14/77 (18%) patients and B-type natriuretic peptide in 8/39 (21%) patients. Ventricular dysfunction was identified in 5/27 (19%) patients with an echocardiogram, all of whom had elevated troponin. Ventricular dysfunction resolved by first outpatient follow-up. Conclusion Electrocardiogram and troponin can assist clinicians in identifying children at risk for cardiac injury in acute COVID-19.

4.
Cardiol Young ; 32(12): 2005-2008, 2022 Dec.
Article in English | MEDLINE | ID: mdl-35383549

ABSTRACT

Congenital left ventricle to coronary sinus fistula is a rare entity. We report a case of an infant with prenatal finding of left ventricle to right atrial shunt. The anatomy was defined by multi-modality imaging. Baseline electrocardiogram was notable for a Wolff-Parkinson-White pattern. He underwent successful catheter device closure of the left ventricle to coronary sinus fistula. The patient developed supraventricular tachycardia and underwent successful ablation of the accessory pathway.


Subject(s)
Catheter Ablation , Coronary Sinus , Fistula , Heart Defects, Congenital , Wolff-Parkinson-White Syndrome , Wolves , Male , Animals , Pregnancy , Female , Coronary Sinus/diagnostic imaging , Coronary Sinus/surgery , Heart Ventricles , Wolff-Parkinson-White Syndrome/complications , Wolff-Parkinson-White Syndrome/diagnosis , Wolff-Parkinson-White Syndrome/surgery , Electrocardiography , Heart Defects, Congenital/surgery , Fistula/surgery
5.
Cardiol Young ; 32(8): 1353-1356, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35199639

ABSTRACT

We present the case of a 4-month-old, former 23-week premature baby who underwent patent ductus arteriosus device closure in the cardiac catheterisation lab with an Amplatzer Piccolo™ device at 12 weeks of life. This was complicated by late migration of the device into the aorta resulting in severe obstruction and requiring surgical intervention.


Subject(s)
Ductus Arteriosus, Patent , Septal Occluder Device , Aorta , Cardiac Catheterization/methods , Ductus Arteriosus, Patent/surgery , Humans , Infant , Infant, Low Birth Weight , Infant, Newborn , Septal Occluder Device/adverse effects , Treatment Outcome
6.
J Pediatr ; 243: 240-241, 2022 04.
Article in English | MEDLINE | ID: mdl-35051414
7.
Ann Pediatr Cardiol ; 15(5-6): 459-466, 2022.
Article in English | MEDLINE | ID: mdl-37152504

ABSTRACT

Context: Cardiac injury has been described in both acute COVID-19 and the multisystem inflammatory syndrome in children (MIS-C). Echocardiographic strain has been shown to be a sensitive measure of systolic function. Aims: We sought to describe strain findings in both the groups on initial presentation and follow-up. Settings and Design: A retrospective study analyzing echocardiograms of all patients presenting with acute COVID-19 infection and MIS-C at our institution between March 2020 and December 2020 was performed. Subjects and Methods: TOMTEC software was used for strain analysis in both the study groups (COVID-19 and MIS-C) and age-matched healthy controls. Strain was correlated with LV ejection fraction (EF) and serum troponin levels. Results: Forty-five patients (34 - MIS-C and 11 - COVID-19) met the inclusion criteria. There was a statistically significant decrease in LV longitudinal strain (P < 0.001), LV circumferential strain (P < 0.001), and left atrial strain (P = 0.014) in the MIS-C group when compared to the control group. There was a statistically significant decrease in LV longitudinal strain (P = 0.028) in the acute COVID-19 group. All patients with abnormal left ventricular EF (LVEF) had abnormal strain. However, 14 (41%) patients in the MIS-C group and 3 (27%) in the acute COVID-19 group had preserved LVEF but abnormal strain. There was a significant correlation with LV longitudinal strain (P = 0.005) and LVEF (P = 0.002) and troponin in patients with MIS-C. Abnormal strain persisted in one-third of patients in the MIS-C and acute COVID-19 groups on outpatient follow-up. Conclusions: Patients with MIS-C and acute COVID-19 can develop myocardial dysfunction as seen by abnormal strain. LV longitudinal strain correlates with cardiac injury as measured by serum troponin in patients with MIS-C. Strain may provide an additional tool in detecting subtle myocardial dysfunction. It can be routinely employed at diagnosis and at follow-up evaluation of these patients.

9.
Clin Pediatr (Phila) ; 60(2): 119-126, 2021 02.
Article in English | MEDLINE | ID: mdl-32975439

ABSTRACT

BACKGROUND: The overall severity of cardiac disease secondary to acute SARS-CoV-2 (severe acute respiratory syndrome coronavirus-2) infection in children appears to be much lower when compared with adults. However, the newly described multisystem inflammatory syndrome in children (MIS-C) associated with coronavirus disease 2019 (COVID-19) has been associated with cardiac complications. METHODS: We reviewed the clinical course and cardiac testing results in pediatric patients hospitalized with MIS-C at 2 large hospital systems in the New York City metropolitan area over a 3-month period. RESULTS: Of the 33 patients (median age 2.8 years) in the study cohort, 24 (73%) had at least one abnormality in cardiac testing: abnormal electrocardiogram (48%), elevated brain natriuretic peptide (43%), abnormal echocardiogram (30%), and/or elevated troponin (21%). Electrocardiogram and echocardiogram abnormalities all resolved by the 2-week outpatient follow-up cardiology visit. CONCLUSION: While 73% of pediatric patients with MIS-C had evidence of abnormal cardiac testing on hospital admission in our study, all cardiac testing was normal by outpatient hospital discharge follow-up. Cardiac screening tests should be performed in all patients diagnosed with MIS-C given the high rate of abnormal cardiac findings in our study cohort.


Subject(s)
COVID-19/complications , Cardiovascular Diseases/virology , Systemic Inflammatory Response Syndrome/complications , COVID-19/epidemiology , Child , Child, Preschool , Female , Humans , Infant , Male , New York City/epidemiology , SARS-CoV-2 , Systemic Inflammatory Response Syndrome/epidemiology
10.
Cardiol Young ; 31(2): 297-299, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33103641

ABSTRACT

Cardiac tumours are relatively uncommon, particularly in children. Myofibroma is an extremely rare variety of cardiac tumour, which nearly always arises in the context of infantile myofibromatosis. Herein, we present a case of a solitary cardiac myofibroma causing right ventricular outflow tract obstruction in a 2-month-old male infant.


Subject(s)
Heart Defects, Congenital , Heart Neoplasms , Myofibroma , Myofibromatosis , Skin Neoplasms , Ventricular Outflow Obstruction , Child , Heart Neoplasms/diagnosis , Heart Neoplasms/diagnostic imaging , Humans , Infant , Male , Myofibroma/complications , Myofibroma/diagnosis , Myofibroma/surgery , Ventricular Outflow Obstruction/diagnosis , Ventricular Outflow Obstruction/etiology , Ventricular Outflow Obstruction/surgery
11.
Case Rep Pediatr ; 2014: 626198, 2014.
Article in English | MEDLINE | ID: mdl-25328741

ABSTRACT

Background. Lymphatic malformations or lymphangiomas are rare benign hamartomas that result from maldevelopment of primitive lymphatic sacs. They are most frequently found in the neck and axilla, while intra-abdominal and mediastinal lymphangiomas are uncommon. These are primarily tumours of infancy and childhood and are successfully treated with surgical excision. Summary of Cases. Five cases of lymphangioma comprising three intra-abdominal lymphangiomas and two unilateral axillary lymphangiomas presenting at one institution in Trinidad W.I. between 2005 and 2012 were examined. The presentations, location, workup, treatment, and outcome of these patients were studied. Conclusion. This paper discusses a range of extracervical lymphangioma cases seen at San Fernando General Hospital, Trinidad W.I. We report three intra-abdominal cases and the most common clinical presentations were abdominal pain and distension. Also two axillary cases were reported, which presented as painless axillary masses. The major concerns for excision of axillary lymphangioma by parents and surgeons were cosmesis and feasibility of complete resection without disruption of developing breast tissue and axillary vessels. We believe that ultrasound scan is very good at detection of the lesion, while CT is better at determining tumour content and planning for the operation. It is our opinion that complete surgical excision can be achieved.

SELECTION OF CITATIONS
SEARCH DETAIL
...