2.
Int Ophthalmol ; 43(12): 5063-5069, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37874439

ABSTRACT

PURPOSE: To assess the repeatability and reliability of semi-automated EyeMark Python program measurements compared to manual ImageJ image processing of anterior segment-optical coherence tomography (AS-OCT) structures in healthy and keratoconus eyes. METHODS: Heidelberg AS-OCT was used to image 25 eyes from 14 healthy subjects and 25 eyes from 15 subjects with keratoconus between the ages of 20 and 80 years, collected prospectively, in this observational case-control study. Visual axis scan containing vertical fixation light beam was selected from the 15-line AS-OCT scan raster. Central corneal thickness (CCT), anterior corneal radius of curvature (ACRC), posterior corneal radius of curvature (PCRC), and truncated anterior vault (TAV) were measured using ImageJ software and the EyeMark Python program. MedCalc and R were used to calculate the intraclass correlation coefficient (ICC) and generate Bland-Altman plots (BAP). RESULTS: When comparing the measurements of CCT, ACRC, PCRC, and TAV between manual ImageJ analysis and the EyeMark Python program, ICC values were consistently greater than 0.9, indicating excellent agreement. BAPs comparing the ImageJ and Python measurements of anterior segment structures show no systematic proportional bias and the average differences were near zero and within 95% of the limits of agreement. CONCLUSIONS: Semi-automated tools may provide the necessary efficiency for point-of-care quantitative corneal analysis of raw AS-OCT images. The semi-automated EyeMark Python program offers a repeatable and reliable tool compared to manual ImageJ analysis for measuring anterior segment structures from AS-OCT images among individuals with keratoconus.


Subject(s)
Keratoconus , Humans , Young Adult , Adult , Middle Aged , Aged , Aged, 80 and over , Keratoconus/diagnosis , Tomography, Optical Coherence/methods , Reproducibility of Results , Case-Control Studies , Cornea/diagnostic imaging
3.
Int Ophthalmol ; 42(7): 2117-2126, 2022 Jul.
Article in English | MEDLINE | ID: mdl-34989951

ABSTRACT

PURPOSE: To determine through a feasibility study whether anterior and posterior corneal arc length and cross-sectional area measured using anterior segment ocular coherence tomography (AS-OCT) can distinguish between healthy and keratoconic corneas. METHODS: Patients diagnosed with keratoconus along with healthy controls underwent AS-OCT. ImageJ was used to determine the central 6 mm anterior and posterior corneal arc lengths and cross-sectional areas. Each length and area was then divided into 1-mm segment and relative differences compared. RESULTS: Twenty-five eyes from 15 patients with keratoconus, along with 25 eyes from 14 healthy controls were enrolled. There was a statistically significant difference in anterior and posterior corneal arc lengths as well as corneal cross-sectional area (p = 0.006, p = 0.005, p = 0.01, respectively). When selecting for the less advanced keratoconus eye, it was noted that posterior corneal arc length was longer in the paracentral temporal segment (1003 vs. 1010 µm, p = 0.04) and that greater change in corneal cross-sectional areas occurred between adjacent segments in less advanced keratoconus eyes. CONCLUSION: AS-OCT is capable of reliably measuring corneal arc lengths in patients with keratoconus and healthy patients. Both anterior and posterior corneal arc lengths along with central cross-sectional areas are statistically different between healthy and keratoconus eyes.


Subject(s)
Keratoconus , Biometry , Cornea/diagnostic imaging , Corneal Topography/methods , Humans , Keratoconus/diagnosis , Tomography, Optical Coherence/methods
4.
Eye Contact Lens ; 47(9): 494-499, 2021 Sep 01.
Article in English | MEDLINE | ID: mdl-34294643

ABSTRACT

OBJECTIVES: To determine the repeatability of corneal measurements from anterior segment optical coherence tomography (AS-OCT) images using ImageJ software in healthy eyes compared with eyes with keratoconus. METHODS: Anterior segment OCT images of 25 eyes from 14 healthy subjects and 25 eyes from 15 subjects with keratoconus between the ages of 20 and 80 years were evaluated. Two trained observers used ImageJ to measure the central corneal cross-sectional area and anterior and posterior corneal arc lengths. MedCalc statistical software was used to generate the intraclass correlation coefficient (ICC) and Bland-Altman plots (BAPs) for observer measurements. RESULTS: Observer measurements of the central corneal cross-sectional area and anterior and posterior corneal arc lengths yielded an ICC >0.7. The ICC comparing the 3 parameters ranged from 0.75 to 0.84 for the control and 0.96 to 0.98 for the keratoconus group. No systematic proportional bias was detected by the BAPs. There were minimal differences between the 2 observer's measurements, with a mean of the difference of 0.3 mm2, 0 mm, and 0 mm, for the 3 measurements, respectively. CONCLUSIONS: This study suggests that ImageJ software is a repeatable and reliable tool in the analysis of corneal parameters from AS-OCT images among patients with keratoconus and may be applicable to AS-OCT imaging protocol development, an area of active keratoconus research.


Subject(s)
Keratoconus , Tomography, Optical Coherence , Adult , Aged , Aged, 80 and over , Cornea/diagnostic imaging , Healthy Volunteers , Humans , Keratoconus/diagnostic imaging , Middle Aged , Reproducibility of Results , Young Adult
5.
Sci Rep ; 9(1): 20178, 2019 12 27.
Article in English | MEDLINE | ID: mdl-31882799

ABSTRACT

Changes in retinal blood flow may be involved in the pathogenesis of glaucoma and other ocular diseases. Erythrocyte mediated velocimetry (EMV) is a novel technique where indocyanine green (ICG) dye is sequestered in erythrocyte ghosts and autologously re-injected to allow direct visualization of erythrocytes for in vivo measurement of speed. The purpose of this study is to determine the mean erythrocyte speed in the retinal microvasculature, as well as the intravisit and intervisit variability of EMV. Data from 23 EMV sessions from control, glaucoma suspect, and glaucoma patients were included in this study. In arteries with an average diameter of 43.11 µm ± 6.62 µm, the mean speed was 7.17 mm/s ± 2.35 mm/s. In veins with an average diameter of 45.87 µm ± 12.04 µm, the mean speed was 6.05 mm/s ± 1.96 mm/s. Intravisit variability, as measured by the mean coefficient of variation, was 3.57% (range 0.44-9.68%). Intervisit variability was 4.85% (range 0.15-8.43%). EMV may represent reliable method for determination of retinal blood speed, potentially allowing insights into the effects of pharmacologic agents or pathogenesis of ocular diseases.


Subject(s)
Blood Flow Velocity/physiology , Erythrocytes/physiology , Glaucoma/physiopathology , Microvessels/physiopathology , Retinal Vessels/physiopathology , Aged , Case-Control Studies , Female , Humans , Intraocular Pressure , Male , Middle Aged , Rheology
6.
Perfusion ; 32(4): 301-305, 2017 May.
Article in English | MEDLINE | ID: mdl-27881701

ABSTRACT

AIM: We sought to quantify the location and volume of thrombus in used hollow-fiber membrane oxygenators and correlate the volume of thrombus with patient demographics, flow characteristics and anticoagulation parameters. METHODS: Hollow-fiber membrane oxygenators (Quadrox D, Maquet, Rastatt, Germany) were collected after clinical use in ECMO circuits and divided into sections. Each section was digitally imaged and analyzed using ImageJ software. The location and total volume (cm3) of thrombus was calculated for different sections. In an effort to predict thrombus formation, we correlated thrombus volume with possible aggravating and mitigating variables. RESULTS: We collected 41 oxygenators from 27 patients. Twenty-seven (66%) were configured in the veno-venous mode and 14 (34%) in the veno-arterial mode. The median duration of use was 131 hours (interquartile range 61-214 hours). Eighteen (44%) were removed when the patient recovered, six (15%) were removed after withdrawal of care and seventeen (41%) were exchanged. The median volume of thrombus was 11.4 cm3 (interquartile range 2.2-44.5 cm3). CONCLUSIONS: A multivariable linear regression model suggested that the combination of median flow, configuration of ECMO and visible thrombus partially predicted internal thrombus volume (adjusted R2=0.39).


Subject(s)
Extracorporeal Membrane Oxygenation/instrumentation , Extracorporeal Membrane Oxygenation/methods , Oxygenators, Membrane , Thrombosis/pathology , Adult , Female , Humans , Male , Middle Aged , Thrombosis/blood