Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters











Database
Language
Publication year range
1.
Pediatr Pulmonol ; 2024 Jul 18.
Article in English | MEDLINE | ID: mdl-39023392

ABSTRACT

INTRODUCTION: Major methodological issues with the existing algorithm (WBreath) used for the analysis of speed-of-sound-based infant sulfur hexafluoride (SF6) multiple-breath washout (MBW) measurements lead to implausible results and complicate the comparison between different age groups and centers. METHODS: We developed OASIS-a novel algorithm to analyze speed-of-sound-based infant SF6 MBW measurements. This algorithm uses known context of the measurements to replace the dependence of WBreath on model input parameters. We validated the functional residual capacity (FRC) measurement accuracy of this new algorithm in vitro, and investigated its use in existing infant MBW data sets from different infant cohorts from Switzerland and South Africa. RESULTS: In vitro, OASIS managed to outperform WBreath at FRC measurement accuracy, lowering mean (SD) absolute error from 5.1 (3.2) % to 2.1 (1.6) % across volumes relevant for the infant age range, in variable temperature, respiratory rate, tidal volume and ventilation inhomogeneity conditions. We showed that changes in the input parameters to WBreath had a major impact on MBW results, a methodological drawback which does not exist in the new algorithm. OASIS produced more plausible results than WBreath in longitudinal tracking of lung clearance index (LCI), provided improved measurement stability in LCI over time, and improved comparability between centers. DISCUSSION: This new algorithm represents a meaningful advance in obtaining results from a legacy system of lung function measurement by allowing a single method to analyze measurements from different age groups and centers.

2.
Pediatr Pulmonol ; 57(5): 1180-1187, 2022 05.
Article in English | MEDLINE | ID: mdl-35182057

ABSTRACT

BACKGROUND: The recently described sensor-crosstalk error in the multiple-breath washout (MBW) device Exhalyzer D (Eco Medics AG) could highly influence clinimetric properties and the current interpretation of MBW results. This study reanalyzes MBW data from clinical routine in the corrected software version Spiroware® 3.3.1 and evaluates the effect on outcomes. METHODS: We included nitrogen-MBW data from healthy children and children with cystic fibrosis (CF) from previously published trials and ongoing cohort studies. We specifically compared lung clearance index (LCI) analyzed in Spiroware 3.2.1 and 3.3.1 with regard to (i) feasibility, (ii) repeatability, and (iii) validity as outcome parameters in children with CF. RESULTS: (i) All previously collected measurements could be reanalyzed and resulted in unchanged feasibility in Spiroware 3.3.1. (ii) Short- and midterm repeatability of LCI was similar in both software versions. (iii) Clinical validity of LCI remained similar in Spiroware 3.3.1; however, this resulted in lower values. Discrimination between health and disease was comparable between both software versions. The increase in LCI over time was less pronounced with 0.16 LCI units/year (95% confidence interval [CI] 0.08; 0.24) versus 0.30 LCI units/year (95% CI 0.21; 0.38) in 3.2.1. Response to intervention in children receiving CF transmembrane conductance-modulator therapy resulted in a comparable improvement in LCI, in both Spiroware versions. CONCLUSION: Our study confirms that clinimetric properties of LCI remain unaffected after correction for the cross-sensitivity error in Spiroware software.


Subject(s)
Breath Tests , Cystic Fibrosis , Breath Tests/methods , Child , Humans , Lung , Nitrogen , Respiratory Function Tests/methods
3.
Investig Genet ; 3(1): 25, 2012 Dec 04.
Article in English | MEDLINE | ID: mdl-23211019

ABSTRACT

BACKGROUND: Profiling sperm DNA present on vaginal swabs taken from rape victims often contributes to identifying and incarcerating rapists. Large amounts of the victim's epithelial cells contaminate the sperm present on swabs, however, and complicate this process. The standard method for obtaining relatively pure sperm DNA from a vaginal swab is to digest the epithelial cells with Proteinase K in order to solubilize the victim's DNA, and to then physically separate the soluble DNA from the intact sperm by pelleting the sperm, removing the victim's fraction, and repeatedly washing the sperm pellet. An alternative approach that does not require washing steps is to digest with Proteinase K, pellet the sperm, remove the victim's fraction, and then digest the residual victim's DNA with a nuclease. METHODS: The nuclease approach has been commercialized in a product, the Erase Sperm Isolation Kit (PTC Labs, Columbia, MO, USA), and five crime laboratories have tested it on semen-spiked female buccal swabs in a direct comparison with their standard methods. Comparisons have also been performed on timed post-coital vaginal swabs and evidence collected from sexual assault cases. RESULTS: For the semen-spiked buccal swabs, Erase outperformed the standard methods in all five laboratories and in most cases was able to provide a clean male profile from buccal swabs spiked with only 1,500 sperm. The vaginal swabs taken after consensual sex and the evidence collected from rape victims showed a similar pattern of Erase providing superior profiles. CONCLUSIONS: In all samples tested, STR profiles of the male DNA fractions obtained with Erase were as good as or better than those obtained using the standard methods.

SELECTION OF CITATIONS
SEARCH DETAIL