Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
JACC Cardiovasc Interv ; 16(22): 2722-2732, 2023 Nov 27.
Article in English | MEDLINE | ID: mdl-38030358

ABSTRACT

BACKGROUND: Scarce data exist on the evolution of device-related thrombus (DRT) after left atrial appendage closure (LAAC). OBJECTIVES: This study sought to assess the incidence, predictors, and clinical impact of persistent and recurrent DRT in LAAC recipients. METHODS: Data were obtained from an international multicenter registry including 237 patients diagnosed with DRT after LAAC. Of these, 214 patients with a subsequent imaging examination after the initial diagnosis of DRT were included. Unfavorable evolution of DRT was defined as either persisting or recurrent DRT. RESULTS: DRT resolved in 153 (71.5%) cases and persisted in 61 (28.5%) cases. Larger DRT size (OR per 1-mm increase: 1.08; 95% CI: 1.02-1.15; P = 0.009) and female (OR: 2.44; 95% CI: 1.12-5.26; P = 0.02) were independently associated with persistent DRT. After DRT resolution, 82 (53.6%) of 153 patients had repeated device imaging, with 14 (17.1%) cases diagnosed with recurrent DRT. Overall, 75 (35.0%) patients had unfavorable evolution of DRT, and the sole predictor was average thrombus size at initial diagnosis (OR per 1-mm increase: 1.09; 95% CI: 1.03-1.16; P = 0.003), with an optimal cutoff size of 7 mm (OR: 2.51; 95% CI: 1.39-4.52; P = 0.002). Unfavorable evolution of DRT was associated with a higher rate of thromboembolic events compared with resolved DRT (26.7% vs 15.1%; HR: 2.13; 95% CI: 1.15-3.94; P = 0.02). CONCLUSIONS: About one-third of DRT events had an unfavorable evolution (either persisting or recurring), with a larger initial thrombus size (particularly >7 mm) portending an increased risk. Unfavorable evolution of DRT was associated with a 2-fold higher risk of thromboembolic events compared with resolved DRT.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Stroke , Thromboembolism , Thrombosis , Humans , Female , Incidence , Atrial Appendage/diagnostic imaging , Treatment Outcome , Atrial Fibrillation/epidemiology , Atrial Fibrillation/therapy , Atrial Fibrillation/complications , Thromboembolism/diagnostic imaging , Thromboembolism/epidemiology , Thromboembolism/etiology , Thrombosis/diagnostic imaging , Thrombosis/epidemiology , Thrombosis/etiology , Stroke/etiology
2.
J Am Coll Cardiol ; 78(4): 297-313, 2021 07 27.
Article in English | MEDLINE | ID: mdl-34294267

ABSTRACT

BACKGROUND: Device-related thrombus (DRT) has been considered an Achilles' heel of left atrial appendage occlusion (LAAO). However, data on DRT prediction remain limited. OBJECTIVES: This study constructed a DRT registry via a multicenter collaboration aimed to assess outcomes and predictors of DRT. METHODS: Thirty-seven international centers contributed LAAO cases with and without DRT (device-matched and temporally related to the DRT cases). This study described the management patterns and mid-term outcomes of DRT and assessed patient and procedural predictors of DRT. RESULTS: A total of 711 patients (237 with and 474 without DRT) were included. Follow-up duration was similar in the DRT and no-DRT groups, median 1.8 years (interquartile range: 0.9-3.0 years) versus 1.6 years (interquartile range: 1.0-2.9 years), respectively (P = 0.76). DRTs were detected between days 0 to 45, 45 to 180, 180 to 365, and >365 in 24.9%, 38.8%, 16.0%, and 20.3% of patients. DRT presence was associated with a higher risk of the composite endpoint of death, ischemic stroke, or systemic embolization (HR: 2.37; 95% CI, 1.58-3.56; P < 0.001) driven by ischemic stroke (HR: 3.49; 95% CI: 1.35-9.00; P = 0.01). At last known follow-up, 25.3% of patients had DRT. Discharge medications after LAAO did not have an impact on DRT. Multivariable analysis identified 5 DRT risk factors: hypercoagulability disorder (odds ratio [OR]: 17.50; 95% CI: 3.39-90.45), pericardial effusion (OR: 13.45; 95% CI: 1.46-123.52), renal insufficiency (OR: 4.02; 95% CI: 1.22-13.25), implantation depth >10 mm from the pulmonary vein limbus (OR: 2.41; 95% CI: 1.57-3.69), and non-paroxysmal atrial fibrillation (OR: 1.90; 95% CI: 1.22-2.97). Following conversion to risk factor points, patients with ≥2 risk points for DRT had a 2.1-fold increased risk of DRT compared with those without any risk factors. CONCLUSIONS: DRT after LAAO is associated with ischemic events. Patient- and procedure-specific factors are associated with the risk of DRT and may aid in risk stratification of patients referred for LAAO.


Subject(s)
Atrial Appendage/surgery , Atrial Fibrillation/surgery , Cardiac Catheterization/adverse effects , Postoperative Complications/etiology , Registries , Septal Occluder Device/adverse effects , Thrombosis/etiology , Aged , Atrial Appendage/diagnostic imaging , Echocardiography, Transesophageal , Europe/epidemiology , Female , Follow-Up Studies , Heart Diseases/diagnosis , Heart Diseases/epidemiology , Heart Diseases/etiology , Humans , Incidence , Male , Postoperative Complications/diagnosis , Postoperative Complications/epidemiology , Risk Factors , Survival Rate/trends , Thrombosis/diagnosis , Thrombosis/epidemiology , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...