Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
Sensors (Basel) ; 24(9)2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38732996

ABSTRACT

X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but it is difficult to implement due to the competing requirements of X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while addressing the limitations of conventional tomography tools. The instrument combines the electron beam of a scanning electron microscope (SEM) with the precise, broadband X-ray detection of a superconducting transition-edge sensor (TES) microcalorimeter. The electron beam generates a highly focused X-ray spot on a metal target held micrometers away from the sample of interest, while the TES spectrometer isolates target photons with a high signal-to-noise ratio. This combination of a focused X-ray spot, energy-resolved X-ray detection, and unique system geometry enables nanoscale, element-specific X-ray imaging in a compact footprint. The proof of concept for this approach to X-ray nanotomography is demonstrated by imaging 160 nm features in three dimensions in six layers of a Cu-SiO2 integrated circuit, and a path toward finer resolution and enhanced imaging capabilities is discussed.

2.
Am J Pharm Educ ; 88(3): 100649, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38215940

ABSTRACT

OBJECTIVE: The purpose of this study was to investigate if a correlation exists between a student's self-identified race or ethnicity and their rates of participating in the match or matching with a pharmacy residency. METHODS: This retrospective cohort study included pharmacy graduates from 2016 through 2021 at two schools/colleges of pharmacy, a Historically Black College or University and a non-Historically Black College or University. The primary outcome was to compare the percentage of underrepresented minority (URM) students and non-URM students who successfully matched with a postgraduate year 1 pharmacy residency. The secondary outcomes compared rates of participation in the match and the effects of student-related factors that influenced match success and participation rates between URM students and non-URM students. RESULTS: Of the 900 included students, 273 participated in the match. The match rate among students participating in the match was 53.5% (146 of 273) with 50.3% (84 of 167) in the URM group compared to 58.5% (62 of 106) in the non-URM group (P = .186) successfully matching. Rates of match participation were lower for students identified as URM (26% vs 39.3%, P < .001). When adjusting for previously published predictors of match success, URM status did not significantly affect match rates or match participation. CONCLUSION: At two schools of pharmacy, URM students were less likely to participate in the match but just as likely to match to an American Society of Health-System Pharmacists residency in the univariable analysis. However, when adjusting for other characteristics, there was no difference in match participation or match success in students who self-identified as URM.


Subject(s)
Education, Pharmacy , Internship and Residency , Pharmacy Residencies , Students, Pharmacy , Humans , United States , Ethnicity , Retrospective Studies , Minority Groups
3.
Article in English | MEDLINE | ID: mdl-35529769

ABSTRACT

Feature sizes in integrated circuits have decreased substantially over time, and it has become increasingly difficult to three-dimensionally image these complex circuits after fabrication. This can be important for process development, defect analysis, and detection of unexpected structures in externally sourced chips, among other applications. Here, we report on a non-destructive, tabletop approach that addresses this imaging problem through x-ray tomography, which we uniquely realize with an instrument that combines a scanning electron microscope (SEM) with a transition-edge sensor (TES) x-ray spectrometer. Our approach uses the highly focused SEM electron beam to generate a small x-ray generation region in a carefully designed target layer that is placed over the sample being tested. With the high collection efficiency and resolving power of a TES spectrometer, we can isolate x-rays generated in the target from background and trace their paths through regions of interest in the sample layers, providing information about the various materials along the x-ray paths through their attenuation functions. We have recently demonstrated our approach using a 240 Mo/Cu bilayer TES prototype instrument on a simplified test sample containing features with sizes of ∼ 1 µm. Currently, we are designing and building a 3000 Mo/Au bilayer TES spectrometer upgrade, which is expected to improve the imaging speed by factor of up to 60 through a combination of increased detector number and detector speed.

4.
Rev Sci Instrum ; 90(11): 113101, 2019 Nov 01.
Article in English | MEDLINE | ID: mdl-31779391

ABSTRACT

We present results obtained with a new soft X-ray spectrometer based on transition-edge sensors (TESs) composed of Mo/Cu bilayers coupled to bismuth absorbers. This spectrometer simultaneously provides excellent energy resolution, high detection efficiency, and broadband spectral coverage. The new spectrometer is optimized for incident X-ray energies below 2 keV. Each pixel serves as both a highly sensitive calorimeter and an X-ray absorber with near unity quantum efficiency. We have commissioned this 240-pixel TES spectrometer at the Stanford Synchrotron Radiation Lightsource beamline 10-1 (BL 10-1) and used it to probe the local electronic structure of sample materials with unprecedented sensitivity in the soft X-ray regime. As mounted, the TES spectrometer has a maximum detection solid angle of 2 × 10-3 sr. The energy resolution of all pixels combined is 1.5 eV full width at half maximum at 500 eV. We describe the performance of the TES spectrometer in terms of its energy resolution and count-rate capability and demonstrate its utility as a high throughput detector for synchrotron-based X-ray spectroscopy. Results from initial X-ray emission spectroscopy and resonant inelastic X-ray scattering experiments obtained with the spectrometer are presented.

5.
Article in English | MEDLINE | ID: mdl-33456289

ABSTRACT

We are designing an array of transition-edge sensor (TES) microcalorimeters for a soft X-ray spectrometer at the Linac Coherent Light Source at SLAC National Accelerator Laboratory to coincide with upgrades to the free electron laser facility. The complete spectrometer will have 1000 TES pixels with energy resolution of 0.5 eV full-width at half-maximum (FWHM) for incident energies below 1 keV while maintaining pulse decay-time constants shorter than 100 µs. Historically, TES pixels have often been designed for a particular scientific application via a combination of simple scaling relations and trial-and-error experimentation with device geometry. We have improved upon this process by using our understanding of transition physics to guide TES design. Using the two-fluid approximation of the phase-slip line model for TES resistance, we determine how the geometry and critical temperature of a TES will affect the shape of the transition. We have used these techniques to design sensors with a critical temperature of 55 mK. The best sensors achieve an energy resolution of 0.75 eV FWHM at 1.25 keV. Building upon this result, we show how the next generation of sensors can be designed to reach our goal of 0.5 eV resolution.

6.
Appl Phys Lett ; 114(23)2019.
Article in English | MEDLINE | ID: mdl-38487744

ABSTRACT

The development of a superconducting analog to the transistor with extremely low power dissipation will accelerate the proliferation of low-temperature circuitry operating in the milliKelvin regime. The thin-film, magnetically actuated cryotron switch is a candidate building block for more complicated and flexible milliKelvin circuitry. We demonstrate its utility for implementing reconfigurable circuitry by integrating a cryotron switch into flux-summed code-division SQUID multiplexed readout for large arrays of transition-edge-sensor (TES) microcalorimeters. Code-division multiplexing eliminates the noise penalty of time-division multiplexing while being drop-in compatible with the latter's control electronics. However, code-division multiplexing is susceptible to single-point failure mechanisms which can result in an unconstrained demodulation matrix and the loss of information from many sensing elements. In the event of a failure, the integrated cryotron switch provides a zero-signal output from a single TES, enabling the demodulation matrix used to compute TES signals from SQUID signals to be constrained and data recovered from the remaining sensors. This demonstration of configurable error correction provides both a realworld application of the cryotron switch and a foundation for more complex circuitry at milliKelvin temperatures.

7.
J Chem Phys ; 147(21): 214201, 2017 Dec 07.
Article in English | MEDLINE | ID: mdl-29221417

ABSTRACT

We present X-ray absorption spectroscopy and resonant inelastic X-ray scattering (RIXS) measurements on the iron L-edge of 0.5 mM aqueous ferricyanide. These measurements demonstrate the ability of high-throughput transition-edge-sensor (TES) spectrometers to access the rich soft X-ray (100-2000 eV) spectroscopy regime for dilute and radiation-sensitive samples. Our low-concentration data are in agreement with high-concentration measurements recorded by grating spectrometers. These results show that soft-X-ray RIXS spectroscopy acquired by high-throughput TES spectrometers can be used to study the local electronic structure of dilute metal-centered complexes relevant to biology, chemistry, and catalysis. In particular, TES spectrometers have a unique ability to characterize frozen solutions of radiation- and temperature-sensitive samples.

8.
J Appl Phys ; 121(7)2017 Feb 21.
Article in English | MEDLINE | ID: mdl-31359885

ABSTRACT

We have measured the resistance R(T, I, B ext) of a superconducting transition edge sensor over the entire transition region on a fine scale, producing a 4-dimensional map of the resistance surface. The dimensionless temperature and current sensitivities ( α ≡ ∂ log R / ∂ log T | I and ß ≡ ∂ log R / ∂ log I | T ) of the TES resistance have been determined at each point. α and ß are closely related to the sensor performance, but show a great deal of complex, large amplitude fine structure over large portions of the surface that is sensitive to the applied magnetic field. We discuss the relation of this structure to the presence of Josephson "weak link" fringes.

9.
J Low Temp Phys ; 184(3-4): 647-653, 2016 Aug.
Article in English | MEDLINE | ID: mdl-31186583

ABSTRACT

Superconducting/normal metal bilayers with tunable transition temperature are a critical ingredient to the fabrication of high performance transition edge-sensors (TES). Popular material choices include Mo/Au and Mo/Cu, which exhibit good environmental stability and provide low resistivity films to achieve adequate thermal conductivity. The deposition of high quality Mo films requires sufficient adatom mobility, which can be provided by energetic ions in sputter deposition, or by heating the substrate in an e-beam evaporation process. The bilayer T c depends sensitively on the exact deposition conditions of the Mo layer and the superconducting/normal metal interface. Because the individual contributions (strain, crystalline structure, contamination) are difficult to disentangle and control, reproducibility remains a challenge. Recently, we have demonstrated that low energy ion beam assist during e-beam evaporation offers an alternative route to reliably produce high quality Mo films without the use of substrate heating. The energy and momentum delivered by the ion beam provides an additional control knob to tune film properties such as resistivity and stress. In this report we describe modifications made to the commercial end-Hall ion-source to avoid iron contamination allowing us to produce superconducting Mo films. We show that the ion beam is effective at enhancing the bilayer interface transparency and that bilayers can be further tuned to reduced T c and higher conductivity by vacuum annealing.

10.
Appl Phys Lett ; 109(14)2016.
Article in English | MEDLINE | ID: mdl-38495106

ABSTRACT

Low-temperature superconducting circuits have become important for many scientific applications. However, there are presently no high current-capacity switches (~1 mA) with low power dissipation for sub-Kelvin operation. One candidate for a sub-Kelvin switch is the cryotron, a device in which the superconductivity of a wire is suppressed with a magnetic field. Here, we demonstrate a cryotron switch suitable for sub-Kelvin temperatures. In the closed state, the maximum device current is about 900 µA. The device is switched to its open state with 2 mA of control current and has a leakage of approximately 500 nA. The transition between the closed and open states of the device is faster than 200 ns, where the measurement is limited by the speed of our measurement apparatus. We also discuss low-temperature applications for our cryotron such as a single-pole, double-throw switch.

SELECTION OF CITATIONS
SEARCH DETAIL
...