Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
2.
Eur J Obstet Gynecol Reprod Biol ; 294: 128-134, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38237311

ABSTRACT

OBJECTIVE: to investigate the correlation between the intrapartum CardioTocoGraphic (CTG) findings "suggestive of fetal inflammation" ("SOFI") and the interleukin (IL)-6 level in the umbilical arterial blood. STUDY DESIGN: prospective cohort study conducted at a tertiary maternity unit and including 447 neonates born at term. METHODS: IL-6 levels were systematically measured at birth from a sample of blood taken from the umbilical artery. The intrapartum CTG traces were retrospectively reviewed by two experts who were blinded to the postnatal umbilical arterial IL-6 values as well as to the neonatal outcomes. The CTG traces were classified into "suggestive of fetal inflammation (SOFI)" and "no evidence of fetal inflammation (NEFI) according to the principles of physiologic interpretation the CTG traces. The CTG was classified as "SOFI" if there was a persistent fetal heart rate (FHR) increase > 10 % compared with the observed baseline FHR observed at the admission or at the onset of labor without any preceding repetitive decelerations. The occurrence of Composite Adverse Outcome (CAO) was defined as Neonatal Intensive Care Unit (NICU) or Special Care Baby Unit (SCBU) admission due to one or more of the following: metabolic acidaemia, Apgar score at 5 min ≤ 7, need of neonatal resuscitation, respiratory distress, tachypnoea/polypnea, jaundice requiring phototherapy, hypotension, body temperature instability, poor perinatal adaptation, suspected or confirmed early neonatal sepsis. MAIN OUTCOME MEASURES: To compare the umbilical IL-6 values between the cases with intrapartum CTG traces classified as "SOFI" and those classified as "NEFI"; to assess the correlation of umbilical IL-6 values with the neonatal outcome. RESULTS: 43 (9.6 %) CTG traces were categorized as "SOFI"; IL-6 levels were significantly higher in this group compared with the "NEFI" group (82.0[43.4-325.0] pg/ml vs. 14.5[6.8-32.6] pg/mL; p <.001). The mean FHR baseline assessed 1 h before delivery and the total labor length showed an independent and direct association with the IL-6 levels in the umbilical arterial blood (p <.001 and p = 0.005, respectively). CAO occurred in 33(7.4 %) cases; IL-6 yielded a good prediction of the occurrence of the CAO with an AUC of 0.72 (95 % CI 0.61-0.81). CONCLUSION: Intrapartum CTG findings classified as "SOFI" are associated with higher levels of IL-6 in the umbilical arterial blood.


Subject(s)
Cardiotocography , Interleukin-6 , Pregnancy , Infant, Newborn , Humans , Female , Retrospective Studies , Prospective Studies , Resuscitation , Umbilical Arteries , Inflammation , Heart Rate, Fetal
3.
Am J Obstet Gynecol MFM ; 5(8): 101038, 2023 08.
Article in English | MEDLINE | ID: mdl-37245605

ABSTRACT

BACKGROUND: Perineal injury following vaginal delivery represents a major cause of long-term maternal morbidity, and its prevention is among the priorities of modern obstetrical practice. OBJECTIVE: This study aimed to investigate whether the systematic implementation of a bundle of maneuvers to prevent perineal injury (ie, the "shoulder-up" bundle) may reduce the rate of spontaneous perineal tears in women delivering at a single tertiary maternity unit. STUDY DESIGN: This was a single-center retrospective intervention study including all vaginal deliveries between April 1, 2020 and March 31, 2022. On March 1, 2021, a bundle focused on perineal injury prevention in vaginal deliveries was implemented and introduced as a standard of care. The "shoulder-up" bundle includes the addition of a hands-on technique for the delivery of the posterior shoulder, which is slowly lifted up under the direct visualization of the perineal body, immediately after the disengagement of the anterior shoulder. The labor ward staff underwent dedicated training to acquire expertise on the "shoulder-up" bundle. Little changes in terms of medical and midwifery staffing were recorded during the study period. The incidence of spontaneous second-degree or higher perineal tears was compared between the patients who gave birth before the clinical implementation of the bundle (standard-care group) and those who were delivered following the implementation of the bundle (shoulder-up group). A 1:1 propensity score matching of the 2 groups was done for the variables that proved to be independently associated with the perineal outcome. RESULTS: From April 1, 2020 to March 31, 2022, 3671 patients had a vaginal birth at our tertiary care unit (1786 in the standard-care group and 1885 in the "shoulder-up" group) and were enrolled in the study population. Of these, 1191 (32.4%) had a spontaneous second-degree or higher perineal tear. At univariate analysis, nulliparity (59.6% vs 39.1%; P<.001), higher gestational age at delivery (39.8±1.28 vs 39.4±1.97 weeks; P<.001), epidural analgesia (40.6% vs 31.2%; P<.001), vacuum-assisted delivery (9.6% vs 4.0%; P<.001), and birthweight >4 kg (11.0% vs 6.3%; P<.001) were independently associated with the perineal outcome. Following propensity score matching for the above cited factors, the 1703 patients of each group were compared. A significant increase in the rate of intact perineum (71.0% vs 64.1%; P=.014) and a reduction in the incidence of second- (27.2% vs 32.9%; P=.006) and third to fourth-degree perineal tears (1.3% vs 3.0%; P<.001) was demonstrated in the "shoulder-up" group. Among the subgroup of patients undergoing vacuum-assisted delivery, a borderline significant reduction in the rate of obstetrical anal sphincter injury (10.4% vs 2.9%; P=.052) was also observed. CONCLUSION: Our study showed that the clinical implementation of the "shoulder-up" bundle at vaginal delivery is associated with a significant reduction in the incidence of spontaneous second-degree or higher perineal tears.


Subject(s)
Perineum , Shoulder , Pregnancy , Humans , Female , Infant , Retrospective Studies , Perineum/injuries , Incidence , Propensity Score , Delivery, Obstetric/adverse effects , Delivery, Obstetric/methods
4.
Am J Obstet Gynecol MFM ; 4(6): 100710, 2022 11.
Article in English | MEDLINE | ID: mdl-35964934

ABSTRACT

BACKGROUND: Labor arrest is estimated to account for approximately one-third of all primary cesarean deliveries, and is associated with an increased risk of adverse maternal and perinatal outcomes. One of the main causes is the mismatch between the size of the birth canal and that of the fetus, a condition usually referred to as cephalopelvic disproportion. OBJECTIVE: This study aimed to describe a new ultrasound predictor of labor arrest leading to cesarean delivery because of suspected cephalopelvic disproportion. STUDY DESIGN: This was a multicenter prospective study conducted at 3 maternity units from January 2021 to January 2022. A nonconsecutive series of singleton pregnancies with cephalic-presenting fetuses, gestational age of 34 weeks+0 days or above, and no contraindication to vaginal delivery attending at the antenatal clinics of each institution were considered eligible. Between 34+0 and 38+0 weeks of gestation, all eligible patients were submitted to transabdominal 2D ultrasound measurement of the obstetrical conjugate. On admission to the labor ward, the fetal head circumference was measured on the standard transthalamic plane by transabdominal ultrasound. The primary outcome of the study was the accuracy of the ratio between the fetal head circumference and the obstetrical conjugate measurement (ie, head circumference/obstetrical conjugate ratio) in predicting the occurrence of cesarean delivery secondary to labor arrest. The secondary outcome was the relationship between the head circumference/obstetrical conjugate ratio and labor duration. RESULTS: A total of 263 women were included. Cesarean delivery for labor arrest was performed in 7.6% (20/263) of the included cases and was associated with more frequent use of epidural analgesia (95.0% vs 45.7%; P<.001), longer second stage of labor (193 [120-240] vs 34.0 [13.8-66.5] minutes; P=.002), shorter obstetrical conjugate (111 [108-114] vs 121 [116-125] mm; P<.001), higher head circumference/obstetrical conjugate ratio (3.2 [3.2-3.35] vs 2.9 [2.8-3.0]; P<.001), and higher birthweight (3678 [3501-3916] vs 3352 [3095-3680] g; P=.003) compared with vaginal delivery. At logistic regression analysis, the head circumference/obstetrical conjugate ratio expressed as Z-score was the only parameter independently associated with risk of cesarean delivery for labor arrest (odds ratio, 8.8; 95% confidence interval, 3.6-21.7) and had higher accuracy in predicting cesarean delivery compared with the accuracy of fetal head circumference and obstetrical conjugate alone, with an area under the curve of 0.91 (95% confidence interval, 81.7-99.5; P<.001). A positive correlation between the head circumference/obstetrical conjugate ratio and length of the second stage of labor was found (Pearson coefficient, 0.16; P=.018). CONCLUSION: Our study, conducted on an unselected low-risk population, demonstrated that the head circumference/obstetrical conjugate ratio is a reliable antenatal predictor of labor arrest leading to cesarean delivery.


Subject(s)
Cephalopelvic Disproportion , Labor, Obstetric , Female , Pregnancy , Humans , Infant , Prospective Studies , Cephalopelvic Disproportion/diagnosis , Cephalopelvic Disproportion/epidemiology , Cephalopelvic Disproportion/etiology , Ultrasonography, Prenatal/methods , Risk Factors
5.
Acta Obstet Gynecol Scand ; 100(10): 1917-1923, 2021 Oct.
Article in English | MEDLINE | ID: mdl-34240404

ABSTRACT

INTRODUCTION: The obstetric conjugate represents the shortest anteroposterior diameter of the birth canal and it reflects the capacity of the pelvic inlet to allow the passage and the engagement of the fetal head. The antepartum evaluation of this parameter may be attempted at digital examination to predict the risk of cephalopelvic disproportion, but the accuracy of clinical pelvimetry is notoriously poor. The aim of our study was to describe the sonographic measurement of the obstetric conjugate at transabdominal 2D-ultrasound and to assess its reproducibility. MATERIAL AND METHODS: This is a prospective cohort study conducted at a tertiary University hospital. A non-consecutive series of pregnant women with uncomplicated singleton pregnancies attending the antenatal clinic for routine booking from 34 weeks of gestation onward were included. The ultrasound probe was longitudinally placed above the level of the symphysis and the interpubic fibrocartilaginous disk was visualized. Then the promontory was identified as the most prominent segment of the sacral vertebral column. The obstetric conjugate was measured as the distance between the inner edge of the interpubic disk and the promontory. The inter- and intraobserver repeatability of this measurement was calculated using the intraclass correlation coefficient (ICC) and the Bland-Altman method. RESULTS: In all, 119 women were considered eligible for the study; of these, 111/119 (93.3%) women were included in the analysis with a median gestational age of 36.0 (35.0-37.0) weeks. The mean obstetric conjugate measurement was 11.4 ± 0.93 mm for the first operator and 11.4 ± 0.91 mm for the second operator. The overall interobserver ICC was 0.95 (95% [confidence interval] CI 0.92-0.96) and the overall intraobserver ICC was 0.97 (95% CI 0.96-0.98). Limits of agreement ranged from -0.84 to 0.80 for interobserver measures and from -0.64 to 0.62 for intraobserver measures. The degree of reliability was also analyzed for women with a body mass index ≥30 and for women with a gestational age ≥37 weeks. The inter- and intraobserver ICCs were respectively 0.97 (95% CI 0.90-0.98) and 0.98 (0.95-0.99) in the former group and 0.96 (95% CI 0.93-0.98) and 0.97 (95% CI 0.95-0.98) in the latter group. CONCLUSIONS: Our study demonstrated that among pregnant women at term gestation, sonographic measurement of the obstetric conjugate is feasible and reproducible.


Subject(s)
Cephalopelvic Disproportion/diagnostic imaging , Ultrasonography, Prenatal , Adult , Cohort Studies , Female , Humans , Infant, Newborn , Pregnancy , Prenatal Care , Prospective Studies , Reproducibility of Results
6.
Am J Obstet Gynecol ; 225(2): 171.e1-171.e12, 2021 08.
Article in English | MEDLINE | ID: mdl-33675795

ABSTRACT

BACKGROUND: To date, no research has focused on the sonographic quantification of the degree of flexion of the fetal head in relation to the labor outcome in women with protracted active phase of labor. OBJECTIVE: This study aimed to assess the relationship between the transabdominal sonographic indices of fetal head flexion and the mode of delivery in women with protracted active phase of labor. STUDY DESIGN: Prospective evaluation of women with protracted active phase of labor recruited across 3 tertiary maternity units. Eligible cases were submitted to transabdominal ultrasound for the evaluation of the fetal head position and flexion, which was measured by means of the occiput-spine angle in fetuses in nonocciput posterior position and by means of the chin-to-chest angle in fetuses in occiput posterior position. The occiput-spine angle and the chin-to-chest angle were compared between women who had vaginal delivery and those who had cesarean delivery. Cases where obstetrical intervention was performed solely based on suspected fetal distress were excluded. RESULTS: A total of 129 women were included, of whom 43 (33.3%) had occiput posterior position. Spontaneous vaginal delivery, instrumental delivery, and cesarean delivery were recorded in 66 (51.2%), 17 (13.1%), and 46 (35.7%) cases, respectively. A wider occiput-spine angle was measured in women who had vaginal delivery compared with those submitted to cesarean delivery owing to labor dystocia (126±14 vs 115±24; P<.01). At the receiver operating characteristic curve, the area under the curve was 0.675 (95% confidence interval, 0.538-0.812; P<.01), and the optimal occiput-spine angle cutoff value discriminating between cases of vaginal delivery and those delivered by cesarean delivery was 109°. A narrower chin-to-chest angle was measured in cases who had vaginal delivery compared with those undergoing cesarean delivery (27±33 vs 56±28 degrees; P<.01). The area under the curve of the chin-to-chest angle in relation to the mode of delivery was 0.758 (95% confidence interval, 0.612-0.904; P<.01), and the optimal cutoff value discriminating between vaginal delivery and cesarean delivery was 33.0°. CONCLUSION: In women with protracted active phase of labor, the sonographic demonstration of fetal head deflexion in occiput posterior and in nonocciput posterior fetuses is associated with an increased incidence of cesarean delivery owing to labor dystocia. Such findings suggest that intrapartum ultrasound may contribute in the categorization of the etiology of labor dystocia.


Subject(s)
Cesarean Section/statistics & numerical data , Dystocia/diagnostic imaging , Extraction, Obstetrical/statistics & numerical data , Fetus/diagnostic imaging , Labor Presentation , Labor Stage, First , Adult , Delivery, Obstetric/statistics & numerical data , Dystocia/therapy , Female , Head/diagnostic imaging , Humans , Logistic Models , Neck/diagnostic imaging , Pregnancy , Spine/diagnostic imaging , Ultrasonography
7.
Minerva Obstet Gynecol ; 73(1): 34-44, 2021 02.
Article in English | MEDLINE | ID: mdl-33249820

ABSTRACT

The automatic analysis of fetal ECG in labor has been introduced as an adjunct of traditional cardiotocography with the aim to improve the identification of fetuses with intrapartum hypoxia. Several randomized controlled trials and meta-analyses have produced conflicting results, with the most recent randomized controlled trial not demonstrating any improvement in either neonatal outcomes or reduction in operative birth rates. The objective of this review article is to present the state of art about the use of STAN technology in labor ward.


Subject(s)
Cardiotocography , Labor, Obstetric , Electrocardiography , Female , Humans , Hypoxia , Infant, Newborn , Parturition , Pregnancy
8.
J Obstet Gynaecol ; 41(5): 779-784, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33063589

ABSTRACT

Endometrial cancer is the most frequently diagnosed gynecological tumour. Transvaginal ultrasound has a leading role in the preoperative evaluation of endometrial cancer patients. The study aimed to identify factors that can worsen the diagnostic accuracy of transvaginal ultrasound in endometrial cancer patients. We retrospectively analysed 290 patients with histological diagnosis of endometrial adenocarcinoma. Two-dimensional (2D) gray-scale ultrasound and power Doppler imaging were performed. Age, menopause status, obesity, parity, Figo stage and benign uterine disorders were evaluated as possible factors worsening the diagnostic accuracy of the ultrasonography. FIGO stage IB was the main significant confounding factor in the univariate analysis (p = .004). Furthermore, 2D transvaginal ultrasound showed worse diagnostic accuracy in endometrial cancer patients with concomitant benign uterine pathologies.Impact statementWhat is already known on this subject? Many studies have analysed the reliability and diagnostic accuracy of transvaginal ultrasound in predicting myometrial invasion, but few studies have underlined the importance of confounding factors. Shin et al. (2011) showed that diffuse fibromatosis is a quality ultrasound confounding factor. Furthermore, Fischerova et al. (2014) showed that body mass index (BMI) did not influence the diagnostic accuracy of ultrasound assessment.What do the results of this study add? FIGO stage IB is the main factor worsening the diagnostic accuracy of transvaginal ultrasound in endometrial cancer patients (p = .004). Among the 82 patients with histologically proven FIGO stage IB, 27 (32.9%) had a wrong ultrasound prediction of myometrial infiltration. Twenty-one (36.2%) patients in whom there was no agreement between ultrasound prediction of myometrial infiltration and pathological analysis had fibromatosis and/or adenomyosis (p = 0.04).What are the implications of these findings for clinical practice and/or further research? Two-dimensional ultrasound represents a useful tool in the correct pre-operative setting of patients with endometrial cancer. In FIGO stages IB endometrial cancer patients and in conjunction with benign uterine pathologies, 2D transvaginal ultrasound has less diagnostic accuracy. In these cases, MRI still plays a leading role.


Subject(s)
Adenocarcinoma/diagnostic imaging , Endometrial Neoplasms/diagnostic imaging , Ultrasonography/statistics & numerical data , Vagina/diagnostic imaging , Adenocarcinoma/pathology , Adult , Confounding Factors, Epidemiologic , Endometrial Neoplasms/pathology , Female , Humans , Middle Aged , Neoplasm Staging , Preoperative Care , Preoperative Period , Reproducibility of Results , Retrospective Studies , Ultrasonography/methods , Vagina/pathology
9.
Eur J Obstet Gynecol Reprod Biol ; 203: 297-302, 2016 Aug.
Article in English | MEDLINE | ID: mdl-27423030

ABSTRACT

BACKGROUND: The RCOG classification system of CTG trace is widely used for the analysis of the fetal heart rate during the first and second stage of labor. Other authors proposed specific classification systems for the second stage traces. OBJECTIVE: To evaluate the accuracy of RCOG and Piquard cardiotocographic patterns classification systems in predicting fetal acidemia in the second stage of labor. STUDY DESIGN: This was a nested retrospective case-control study including fetuses delivered with metabolic acidemia in the second stage of labor and a matched group of non-acidemic fetuses as controls. Cases and controls were selected from the electronic medical records of the University Hospital of Bologna between 2008 and 2013. The last 60min of the cardiotocograms recorded during the second stage of labor were independently classified by a senior consultant and a trainee according to RCOG and Piquard classifications. The inter-observer agreement and the accuracy of the two classifications in predicting fetal acidemia were evaluated. RESULTS: In all, 82 acidemic fetuses and 164 controls were recruited in the study period. Regarding the CTG traces assessment, the inter-observer agreement was moderate for both the categorizations (RCOG κ=0.584). Unclassifiable CTG patterns were more frequent among acidemic fetuses vs controls either at RCOG and at Piquard evaluation (26.8% vs 7.9%, p<0.001). Both systems yielded a moderate and comparable ability to predict fetal acidemia (RCOG ROC AUC=0.731; 95% CI 0.660-0.795; Piquard ROC AUC=0.773; 95% CI 0.704-0.833. DeLong z-test=1.186, p=0.236). CONCLUSIONS: RCOG and Piquard systems have a moderate accuracy in identifying acidemic fetuses during the second stage of labor. The occurrence of unclassifiable findings seems significantly more common among the acidemic fetuses.


Subject(s)
Acidosis/physiopathology , Cardiotocography/classification , Heart Rate, Fetal/physiology , Labor Stage, Second/physiology , Adult , Case-Control Studies , Female , Humans , Pregnancy , Retrospective Studies
10.
Prenat Diagn ; 35(5): 493-9, 2015 May.
Article in English | MEDLINE | ID: mdl-25619335

ABSTRACT

OBJECTIVE: To perform a sequential analysis of the main cortical fissures in normal fetuses using 3D ultrasound. METHODS: A cohort of patients with uncomplicated singleton pregnancies underwent three consecutive transabdominal scans at 19-21, 26-28 and 30-34 weeks. Volumes of the fetal head were acquired and searched in the multiplanar mode for the following cortical fissures: sylvian, parieto-occipital, calcarine, hippocampus and cingulate. A qualitative analysis of these sulci was performed in each volume by an experienced operator (A) and a trainee (B). By placing the dot on the sulcus in one plane, it was evaluated whether it was visible also in other planes. RESULTS: Fifty patients were included in the study. At 19-21 weeks, the sylvian and parieto-occipital sulci were visualized on at least one plane by both operators in all cases. At 26-28 weeks, all fissures were visualized by both operators on at least one plane, with no significant difference between the performances of the two operators. At 30-34 weeks, a mild overall decline in the accuracy of identification of all the cerebral fissures was observed. CONCLUSIONS: 3D multiplanar mode allows a systematic evaluation of the cortical fissures in normal fetuses since midtrimester.


Subject(s)
Cerebral Cortex/diagnostic imaging , Echoencephalography , Gestational Age , Imaging, Three-Dimensional , Ultrasonography, Prenatal , Adult , Cerebral Cortex/embryology , Cohort Studies , Female , Humans , Longitudinal Studies , Occipital Lobe/diagnostic imaging , Occipital Lobe/embryology , Pregnancy , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...