Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 129
Filter
1.
PLoS One ; 19(5): e0303682, 2024.
Article in English | MEDLINE | ID: mdl-38758920

ABSTRACT

The implantation of uncemented prostheses requires the application of sufficient forces to achieve a press-fit of the implant in the bone. Excessive forces have to be omitted to limit bone damage. Force measurements along the force transmission path between mallet and implant are frequently used to investigate this trade-off. Placing a load cell at a position of interest (PoI), which might be the implant bone interface or the head taper junction, is technically challenging or even impossible so that nearby positions are chosen. Thus, a certain inertia and stiffness remain between the PoI and the sensor, and consequently the measured dynamic forces differ from those at the PoI. This experimental and numerical study aimed to investigate the amount of force reduction along the transmission path while joining femoral heads to stem tapers. Forces were measured in vitro at the tip of the mallet, directly above the polymer tip of the impactor and below the stem taper. Springs and masses were used to represent the responding tissue of a patient. A semi-empirical numerical model of the force transmission path was developed and validated in order to simulate a larger range of responding tissue properties than experimentally possible and to investigate the influence of different surgical instruments. A distinct attenuation was observed since the peak forces at the impactor reached 35% of the applied peak forces and 21% at the stem taper, respectively. The force curves were replicated with a median root mean square error of 3.8% of the corresponding mallet blow for the impactor and 3.6% for the stem. The force measurement position and the used surgical instruments have a strong influence on the measured forces. Consequently, the exact measurement conditions with regard to sensor positioning and used surgical instruments have to be specified and hence only studies with similar setups should be compared to avoid misestimation of the forces at the PoI. The proposed dynamic numerical model is a useful tool to calculate the impact of the chosen or changed mechanical parameters prior to executing experiments and also to extrapolate the effect of changing the applied forces to the resulting forces at the PoI.


Subject(s)
Hip Prosthesis , Humans , Stress, Mechanical , Biomechanical Phenomena , Femur Head/physiology , Femur Head/surgery , Models, Theoretical
2.
PLoS One ; 19(4): e0300956, 2024.
Article in English | MEDLINE | ID: mdl-38630711

ABSTRACT

Increasing the stem size during surgery is associated with a higher incidence of intraoperative periprosthetic fractures in cementless total hip arthroplasty with fully coated tapered wedge stems, especially in femurs of Dorr type A. If in contrast a stem is implanted and sufficient primary stability is not achieved, such preventing successful osseointegration due to increased micromotions, it may also fail, especially if the stem is undersized. Stem loosening or periprosthetic fractures due to stem subsidence can be the consequence. The adaptation of an established stem design to femurs of Dorr type A by design modifications, which increase the stem width proximally combined with a smaller stem tip and an overall shorter stem, might reduce the risk of distal locking of a proximally inadequately fixed stem and provide increased stability. The aim of this study was to investigate whether such a modified stem design provides improved primary stability without increasing the periprosthetic fracture risk compared to the established stem design. The established (Corail, DePuy Synthes, Warsaw, IN, US) and modified stem designs (Emphasys, DePuy Synthes, Warsaw, IN, US) were implanted in cadaveric femur pairs (n = 6 pairs) using the respective instruments. Broaching and implantation forces were recorded and the contact areas between the prepared cavity and the stem determined. Implanted stems were subjected to two different cyclic loading conditions according to ISO 7206-4 using a material testing machine (1 Hz, 600 cycles @ 80 to 800 N, 600 cycles @ 80 to 1600 N). Translational and rotational relative motions between stem and femur were recorded using digital image correlation. Broaching and implantation forces for the modified stem were up to 40% higher (p = 0.024), achieving a 23% larger contact area between stem and bone (R2 = 0.694, p = 0.039) resulting in a four times lower subsidence during loading (p = 0.028). The slight design modifications showed the desired effect in this in-vitro study resulting in a higher primary stability suggesting a reduced risk of loosening. The higher forces required during the preparation of the cavity with the new broaches and during implantation of the stem could bare an increased risk for intraoperative periprosthetic fractures, which did not occur in this study.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Periprosthetic Fractures , Humans , Hip Prosthesis/adverse effects , Periprosthetic Fractures/epidemiology , Prosthesis Design , Arthroplasty, Replacement, Hip/adverse effects , Osseointegration , Femur/surgery , Reoperation/adverse effects , Retrospective Studies
3.
Orthopadie (Heidelb) ; 53(1): 47-55, 2024 Jan.
Article in German | MEDLINE | ID: mdl-38095661

ABSTRACT

INTRODUCTION: In revision surgery, modular implant components allow the surgeon to tailor the characteristics of the implant to the bone situation. Relative motion can occur at the tapered modular connection, leading to fretting corrosion and subsequent biological reactions, particularly due to poor assembly and contamination of the tapered connection. The aim of this study was to demonstrate whether incomplete assembly and inadvertent contamination of the modular taper causes a change in junction strength. MATERIAL AND METHODS: Modular taper junctions between the neck and the stem (n = 48) were divided into seven groups that differed with respect to contamination (native, contaminated, cleaned) and assembly conditions (secured, pre-tensioned and secured). Contamination was achieved by a combination of porcine bone particles and bovine blood. For each group, the number of rotations of the torque limiter while securing the conical connection was recorded. The implants were subjected to cyclic loading. DIC was used to determine neck rotation, micromotion and axial subsidence. Loosening torque of the locking screw and pull-off forces were measured as an equivalent of residual taper junction strength. RESULTS: Contamination of the taper junction, especially in combination with improper assembly of the components, significantly increased the rotation (35.3 ± 13.7° vs. 2.4 ± 4.4°; p <0.001), micromotion (67.8 ± 16.9 µm vs. 5.1 ± 12.1 µm, p <0.001) and axial subsidence (­34.1 ± 16.9 µm vs. 4.3 ± 10.9 µm; p <0.001) of the neck relative to the stem. CONCLUSION: Intra-operatively, contamination of the taper surface can be identified by the need for multiple turns when tightening the locking screw. Correct cleaning with the new taper cleaning instrument and complete assembly with pre-tensioning may reduce the risk of early failure and fatigue fracture of the modular taper connection.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Animals , Cattle , Prosthesis Design , Prosthesis Failure , Mechanical Phenomena
4.
J Orthop Res ; 42(4): 829-836, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37971200

ABSTRACT

The ideal stem size and stem position is important for the success of total hip arthroplasty, since it can affect early implant loosening and periprosthetic fractures (PPF). This study aimed to investigate how small deviations from the ideal stem size and position influences the PPF risk and primary stability. Six experienced surgeons performed preoperative templating based on which the benchmark size for each femur was determined. Consecutive implantations were performed in six cadaveric femur pairs-one side was implanted with an undersized stem followed by the benchmark size and the contralateral side with a benchmark size followed by an oversized stem (Corail, Depuy Synthes). Moreover, three different alignments (six varus, six neutral, six valgus-undersized) were compared using 18 femurs. Cortical strains during broaching and implantation were measured, and laser scans were used to determine final stem position. All specimens underwent dynamic loading. Primary stability was estimated from stem subsidence and pull-out forces. Templated stem size varied between surgeons (±1 size; p = 0.005). Undersizing increased stem subsidence by 320% (p < 0.001). Oversized stems exhibited 52% higher pull-out forces (p = 0.001) and 240% higher cortical strains (p = 0.056). Cortex strains increased with varus alignment (R2 = 0.356, p = 0.011) while primary stability decreased with valgus stem alignment (p = 0.043). Surgeons should be aware that small deviations from the ideal stem size and malalignments of the stem can significantly alter the mechanical situation and affect the success of their surgery.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Periprosthetic Fractures , Humans , Arthroplasty, Replacement, Hip/adverse effects , Periprosthetic Fractures/etiology , Prosthesis Design , Femur/surgery , Retrospective Studies
5.
J Imaging ; 9(12)2023 Nov 21.
Article in English | MEDLINE | ID: mdl-38132673

ABSTRACT

Three-dimensional body scanners are attracting increasing interest in various application areas. To evaluate their accuracy, their 3D point clouds must be compared to a reference system by using a reference object. Since different scanning systems use different coordinate systems, an alignment is required for their evaluation. However, this process can result in translational and rotational misalignment. To understand the effects of alignment errors on the accuracy of measured circumferences of the human lower body, such misalignment is simulated in this paper and the resulting characteristic error patterns are analyzed. The results show that the total error consists of two components, namely translational and tilt. Linear correlations were found between the translational error (R2 = 0.90, … 0.97) and the change in circumferences as well as between the tilt error (R2 = 0.55, … 0.78) and the change in the body's mean outline. Finally, by systematic analysis of the error patterns, recommendations were derived and applied to 3D body scans of human subjects resulting in a reduction of error by 67% and 84%.

6.
PLoS One ; 18(9): e0291599, 2023.
Article in English | MEDLINE | ID: mdl-37708193

ABSTRACT

BACKGROUND: Despite the success of primary total hip arthroplasty, the number of revisions remains high. Infection, aseptic loosening, periprosthetic fractures and dislocations are the leading causes of hip revision. Current revision stem designs feature a tapered body with circumferential placed longitudinal thin metal splines that cut into the femoral cortex of the diaphysis to provide axial and rotational stability. Modifications to the spline design may help improve primary stability in various bone qualities. The purpose of this study was to evaluate whether the rotational stability of a revision hip stem can be improved by an additional set of less prominent, wider splines in addition to the existing set of splines. It is hypothesized that the additional splines will result in greater cortical contact, thereby improving torsional strength. METHODS AND FINDINGS: The ultimate torsional strength of an established modular revision stem (Reclaim®, DePuy Synthes) was compared to a Prototype stem design with two sets of splines, differing in prominence by 0.25 mm. Five pairs of fresh-frozen human femurs (n = 10) were harvested and an extended trochanteric osteotomy was performed to obtain common bone defects in revision. Stems were implanted using successive droptower impacts to omit variability caused by mallet blows. The applied energy was increased from 2 J in 1 J increments until the planned implantation depth was reached or seating was less than 0.5 mm at 5 J impact. The ultimate torsional strength of the bone-to-implant interface was determined immediately after implantation. Image superposition was used to analyze and quantify the contact situation between bone and implant within the femoral canal. Cortical contact was larger for the Prototype design with the additional set of splines compared to the Reclaim stem (p = 0.046), associated with a higher torsional stability (35.2 ± 6.0 Nm vs. 28.2 ± 3.5 Nm, p = 0.039). CONCLUSIONS: A second set of splines with reduced prominence could be shown to improve primary stability of a revision stem in the femoral diaphysis in the presence of significant proximal bone loss. The beneficial effect of varying spline size and number has the potential to further improve the longevity of revision hip stems.


Subject(s)
Arthroplasty, Replacement, Hip , Bone Diseases, Metabolic , Humans , Femur/surgery , Bone-Implant Interface , Data Accuracy
7.
J Mech Behav Biomed Mater ; 140: 105742, 2023 04.
Article in English | MEDLINE | ID: mdl-36857975

ABSTRACT

BACKGROUND: Patient-specific 3D-printed miniplates for free flap fixation in mandibular reconstruction were recently associated with enhanced osseous union. Higher mechanical strains resulting from these plates are discussed as reasons, but biomechanical studies are missing. This study aims to examine, whether patient-specific 3D-printed miniplates provide an increased interosteotomy movement (IOM) and lower stiffness compared with reconstruction plates. METHODS: Polyurethane (PU) mandible and fibula models (Synbone AG, Malans, Schweiz) were used to simulate mandibular reconstruction with a one segment fibula flap equivalent. Osteosynthesis was performed using either four patient-specific 3D-printed miniplates (3D-Mini) or one patient-specific 3D-printed reconstruction plate (3D-Recon). Mastication was simulated using cyclic dynamic loading with increasing loads until material failure or a maximum load of 1000 N. Continuous IOM recording was carried out using a 3D optical tracking system (ARAMIS, Carl Zeiss GOM Metrology, Braunschweig, Germany). FINDINGS: The averaged stiffness at a load of 100-300 N load did not differ between the groups (p = 0.296). There was a faster 1.0 mm vertical displacement in the 3D-Mini group (26 376 ± 14 190 cycles versus 44 817 ± 30 430 cycles, p = 0.018). The IOM were higher with miniplate fixation in the distal gap (p = 0.040). In the mesial gap, there was no significant difference between the groups (p = 0.160). INTERPRETATION: Fixation with patient-specific 3D-printed miniplates results in higher mechanical strains. Lower rates of pseudarthrosis, as seen in clinical studies, might be caused by this phenomenon. Surgeons should evaluate the primary use of 3D-printed miniplates in mandibular reconstruction due to advantages of intraoral plate removal alongside safe osteosynthesis.


Subject(s)
Mandibular Reconstruction , Humans , Mandibular Reconstruction/methods , Mandible/surgery , Bone Plates , Fracture Fixation, Internal , Printing, Three-Dimensional
8.
Bone Joint J ; 105-B(3): 261-268, 2023 Mar 01.
Article in English | MEDLINE | ID: mdl-36854327

ABSTRACT

The aim of the study was to investigate whether the primary stability of press-fit acetabular components can be improved by altering the impaction procedure. Three impaction procedures were used to implant acetabular components into human cadaveric acetabula using a powered impaction device. An impaction frequency of 1 Hz until complete component seating served as reference. Overimpaction was simulated by adding ten strokes after complete component seating. High-frequency implantation was performed at 6 Hz. The lever-out moment of the acetabular components was used as measure for primary stability. Permanent bone deformation was assessed by comparison of double micro-CT (µCT) measurements before and after impaction. Acetabular component deformation and impaction forces were recorded, and the extent of bone-implant contact was determined from 3D laser scans. Overimpaction reduced primary acetabular component stability (p = 0.038) but did not significantly increase strain release after implantation (p = 0.117) or plastic deformations (p = 0.193). Higher press-fits were associated with larger polar gaps for the 1 Hz reference impaction (p = 0.002, R2 = 0.77), with a similar trend for overimpaction (p = 0.082, R2 = 0.31). High-frequency impaction did not significantly increase primary stability (p = 0.170) at lower impaction forces (p = 0.001); it was associated with smaller plastic deformations (p = 0.035, R2 = 0.34) and a trend for increased acetabular component relaxation between strokes (p = 0.112). Higher press-fit was not related to larger polar gaps for the 6 Hz impaction (p = 0.346). Overimpaction of press-fit acetabular components should be prevented since additional strokes can be associated with increased bone damage and reduced primary stability as shown in this study. High-frequency impaction at 6 Hz was shown to be beneficial compared with 1 Hz impaction. This benefit has to be confirmed in clinical studies.


Subject(s)
Acetabulum , Plastics , Humans , Acetabulum/surgery , X-Ray Microtomography
9.
Orthopadie (Heidelb) ; 52(3): 222-232, 2023 Mar.
Article in German | MEDLINE | ID: mdl-36635446

ABSTRACT

BACKGROUND: Instability constitutes the main reason for revision hip arthroplasties. Modified polyethylene liners are designed to improve the stability of a hip replacement. In July 2022 The Bone & Joint Journal published a study with data of the German Arthroplasty Registry (EPRD). The study investigated mechanical failure of standard and modified liner designs in primary, cementless total hip arthroplasty. Following the study, the EPRD conducted a survey of German clinics to research the utilization of lipped liners in primary total hip replacement. METHODS: The liner study included 151,096 primary, elective, cementless total hip arthroplasties. Data from November 2012 to November 2020 were obtained from the EPRD. Standard polyethylene liners were compared with lipped, angulated, offset and angulated/offset inlays. Cumulative incidences for endpoint revision due to mechanical complication were calculated with a competing risk analysis. The influence of other variables was investigated with a multivariate Cox regression. In the following online survey, 237 out of 789 hospitals completed a form. RESULTS AND CONCLUSION: In our analysis, only offset liners were, compared to standard liners, associated with a reduced risk of mechanical failure in a short to medium follow up. However, the resultant joint reaction force is increased with offset liners due to the lateralization of the hip center of rotation. Thus, the long-term performance of offset liners needs to be observed. Our survey indicated that lipped liners were implanted more often if the posterior approach was used. Moreover, lipped liners were mostly positioned with the elevated rim in the biomechanically less optimal posterior-superior quadrant. To improve stability it is suggested to position the elevated rim in the posterior-inferior quadrant.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Prosthesis Design , Reoperation , Polyethylene , Registries
10.
J Orthop Res ; 41(6): 1283-1290, 2023 06.
Article in English | MEDLINE | ID: mdl-36370133

ABSTRACT

Aseptic loosening is one of the major reasons for re-revisions of cementless revision stems. Insufficient primary stability is associated with bone characteristics and the surgical process. This study aimed to investigate how femur morphology and preparation methods influence the primary stability of revision stems. The Femur morphology was described by the upper femoral curvature (UFC) and an individualized Dorr type classification based on the ratio between the canal-to-calcar ratio (CCR*) and the cortical index (CI*) introduced as the cortical-canal shape (CCS). Manual and powered reaming in combination with helical and straight reamers were used to prepare the bone cavity of 10 cadaveric human femur pairs. Forces during stem impaction were recorded (Reclaim, Depuy Synthes). Micromotion at the bone-implant interface during cyclic axial loading and torsional load to failure was determined. The CCS and impaction forces (R2 = 0.817, p < 0.001) or torsional strength (R2 = 0.577, p < 0.001) are inversely related. CCS did not correlate with micromotion during axial loading (R2 = 0.001, p > 0.999), but proximal femoral curvature did (R2 = 0.462, p = 0.015). Powered reaming and straight reamers led to an improved torsional strength (both: p = 0.043). The Individualized Dorr classification CCS and UFC allows a good estimation of the primary stability of revision stems. For severely curved Dorr type-C femurs, an alternative anchorage method should be considered clinically.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Arthroplasty, Replacement, Hip/methods , Prosthesis Design , Femur/surgery , Lower Extremity/surgery , Reoperation , Retrospective Studies
11.
J Biomech ; 139: 111149, 2022 06.
Article in English | MEDLINE | ID: mdl-35609491

ABSTRACT

Sufficient primary stability is one of the most important prerequisites for successful osseointegration of cementless implants. Bone grafts, densification and compaction methods have proven clinically successful, but the related effects and causes have not been systematically investigated. Postoperatively, the frictional properties of the bone-implant interface determine the amount of tolerable shear stress. Frictional properties of different implant surfaces have been widely studied. Less attention has been paid to the influence of host bone modifications. The purpose of this study was to investigate the influence of densification of cancellous bone with bone particles on the interface friction coefficient. Cancellous bone samples from femoral heads were densified with bone particles obtained during sample preparation. The densification was quantified using micro-Ct. Friction coefficients of the densified and paired native samples were determined. Densification increased the BV/TV in the first two millimeters of the bone samples by 10.5 ± 2.7% to 30.5 ± 2.7% (p < 0.001). The static friction coefficient was increased by 10.5 ± 6.1% to 0.43 ± 0.03. The static friction coefficient increased with higher BV/TV of the bone interface, which is represented by the top 2 mm of the bone. The increase in contact area, intertrabecular anchorage and particle bracing could be responsible for the increase in friction. Optimization of particle shape and size based on the patient's individual bone microstructure could further increase frictional resistance. Bone densification has the potential to improve the primary stability of uncemented implants.


Subject(s)
Cancellous Bone , Osseointegration , Bone-Implant Interface , Femur Head , Friction , Humans
12.
Arthroplast Today ; 14: 14-21, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35106353

ABSTRACT

BACKGROUND: The influence of the surgical process on implant loosening and periprosthetic fractures (PPF) as major complications in uncemented total hip arthroplasty (THA) has rarely been studied because of the difficulty in quantification. Meanwhile, registry analyses have clearly shown a decrease in complications with increasing experience. The goal of this study was to determine the extent of variability in THA stem implantation between highly experienced surgeons with respect to implant size, position, press-fit, contact area, primary stability, and the effect of using a powered impaction tool. METHODS: Primary hip stems were implanted in 16 cadaveric femur pairs by three experienced surgeons using manual and powered impaction. Quantitative CTs were taken before and after each process step, and stem tilt, canal-fill-ratio, press-fit, and contact determined. Eleven femur pairs were additionally tested for primary stability under cyclic loading conditions. RESULTS: Manual impactions led to higher variations in press-fit and contact area between the surgeons than powered impactions. Stem tilt and implant sizing varied between surgeons but not between impaction methods. Larger stems exhibited less micromotion than smaller stems. CONCLUSIONS: Larger implants may increase PPF risk, while smaller implants reduce primary stability. The reduced variation for powered impactions indicates that appropriate measures may promote a more standardized process. The variations between these experienced surgeons may represent an acceptable range for this specific stem design. Variability in the implantation process warrants further investigations since certain deviations, for example, a stem tilt toward varus, might increase bone stresses and PPF risk.

13.
Clin Biomech (Bristol, Avon) ; 94: 105286, 2022 04.
Article in English | MEDLINE | ID: mdl-33678413

ABSTRACT

BACKGROUND: Fractures of modular revision stems at the taper junction are rare but severe clinical problems. The purpose of this study was the estimation of taper loading to identify configurations which are less prone to failure. METHODS: A parametrical analytical 3-D model was developed to determine the influence of neck segment length, offset and anteversion on the loading at the modular taper junction between neck segment and stem. Published in-vivo hip joint forces were used to simulate different activities. FINDINGS: No unique ideal neck segment length can be specified due to the differences in loading magnitude and direction between activities. The best neck segment length for walking is longer than for high loading activities as stair climbing and jogging. A medium length between 70 mm and 90 mm appears to be a good compromise. A shorter offset (37 mm vs. 47 mm) reduces the stress by about 25% for walking and jogging. Retroverted implantation by 5° increases the loading whereas an anteverted implantation by 5° reduces it. A high offset (47 mm) combined with a short neck segment length (50 mm) reaches about 80% of the taper yield strength for jogging (taper diameter 13 mm). INTERPRETATION: Simplified 2-D modelling falsely predicts no bending at the taper junction for a long neck segment, whereas the 3-D model shows substantial stress load along the whole stem length. Stem tapers of short as well as very long neck segments are higher risk for failure. Neck segment length should lie in the range between 70 mm and 90 mm.


Subject(s)
Hip Prosthesis , Hip Joint , Humans , Prosthesis Design
14.
J Orthop Res ; 40(9): 2139-2146, 2022 09.
Article in English | MEDLINE | ID: mdl-34855229

ABSTRACT

Insufficient primary stability of acetabular hip cups is a complication resulting in early cup loosening. Available cup designs vary in terms of wall thickness, potentially affecting implant fixation. This study investigated the influence of different wall thicknesses on the implantation process and the resulting primary stability using excised human acetabula. Implantations were performed using a powered impaction device providing consistent energy with each stroke. Two different wall thicknesses were compared in terms of seating progress, polar gap remaining after implantation, bone-to-implant contact area, cup deflection, and lever out moment. Thin-walled cups showed higher lever out resistance (p < 0.001) and smaller polar gaps (p < 0.001) with larger bone contact toward the dome of the cup (p < 0.001) compared to thick-walled cups. Small seating steps at the end of the impaction process were observed if a high number of strokes were needed to seat the cup (p = 0.045). A high number of strokes led to a strain release of the cup during the final strokes (p = 0.003). This strain release is indicative for over-impaction of the cup associated with bone damage and reduced primary stability. Adequate cup seating can be achieved with thin-walled cups with lower energy input in comparison to thicker ones. Thin-walled cups showed improved primary stability and enable implantation with lower energy input, reducing the risk of over-impaction and bone damage. Additional strokes should be avoided as soon as no further seating progress has been observed.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Acetabulum/surgery , Humans , Prosthesis Design , Prosthesis Failure
15.
Case Rep Orthop ; 2021: 9989395, 2021.
Article in English | MEDLINE | ID: mdl-34659855

ABSTRACT

We report a case of extended osteolysis, requiring a third revision of the left hip in an 85-year-old man 46 years after index operation. Major polyethylene (PE) wear occurred due to a missmatched combination of a bipolar Hastings head with a PE liner and head damage of the originally maintained stem. This case demonstrates that bipolar heads should not be used with PE cup liners since the respective bearing diameters cannot be guaranteed to match due to missing specifications. Furthermore, putting a Hastings head on an already damaged head of the stem should be omitted and rather the stem should initially be revised.

16.
Med Eng Phys ; 95: 25-29, 2021 09.
Article in English | MEDLINE | ID: mdl-34479689

ABSTRACT

BACKGROUND: Gross taper failure (GTF) is a rare but catastrophic failure mode of the head-stem-taper junction of hip prostheses, facilitated by massive material loss. GTF is a two stage process initiated by corrosion leading to head bottoming out, followed by abrasive wear due to the head rotating on the stem. The purpose of this study was to reproduce the clinical failure patterns and to determine the material loss during simulated gait. METHODS: Six cobalt-chromium alloy heads (36 mm, 12/14 taper) with three different head lengths (short / medium / extra long) were combined with stem taper replicas made from titanium alloy sized to achieve bottoming out. A hip simulator was used to simulate gait loading after (ISO 14242-1 for 2 million cycles). RESULTS: Wear patterns from in-vitro testing match the clinical failure patterns. Stem taper wear increased linearly with time (p< 0.001). After two million cycles the material loss of short / medium / extra long heads was (M+-STD) 1168±242 mg / 400±23 mg / 94±12 mg on the stem side and 46±36 mg / 46±24 mg / 70±8 mg on the head side. Stem taper wear decreased with increasing head length (p=0.01), whereas clinical failures are mostly seen for long and extra long heads.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Chromium Alloys , Corrosion , Humans , Prosthesis Design , Prosthesis Failure
17.
World Neurosurg ; 152: e369-e376, 2021 08.
Article in English | MEDLINE | ID: mdl-34087457

ABSTRACT

OBJECTIVE: Loosening of pedicle screws is a frequently observed complication in spinal surgery. Because additional stabilization procedures such as cement augmentation or lengthening of the instrumentation involve relevant risks, optimal stability of the primarily implanted pedicle screw is of essential importance. The aim of the present study was to investigate the effect of increasing the screw diameter on pedicle screw stability. METHODS: A total of 10 human cadaveric vertebral bodies (L4) were included in the present study. The bone mineral density was evaluated using quantitative computed tomography and the pedicle diameter using computed tomography. The vertebrae underwent instrumentation using 6.0-mm × 45-mm pedicle screws on 1 side and screws with the largest possible diameter (8-10-mm × 45-mm) on the other side. Fatigue testing was performed by applying a cyclic loading (craniocaudal sinusoidal 0.5 Hz) with increasing peak force (100 N + 0.1 N/cycle) until screw head displacement of 5.4 mm was reached. RESULTS: The mean fatigue load was 334 N for the 6-mm diameter screws and was increased significantly to 454 N (+36%) for the largest possible diameter screws (P < 0.001). With an increase in the fatigue load by 52%, this effect was even more pronounced in vertebrae with reduced bone density (bone mineral density <120 mg/cm3; n = 7; P < 0.001). The stiffness of the construct was significantly greater in the largest diameter screw group compared with the standard screw group during the entire testing period (start, P < 0.001; middle, P < 0.001; end, P = 0.009). CONCLUSIONS: Increasing the pedicle screw diameter from a standard 6-mm screw to the largest possible diameter (8-10 mm) led to a significantly greater fatigue load.


Subject(s)
Equipment Design , Mechanical Phenomena , Pedicle Screws , Aged , Bone Cements , Bone Density , Cadaver , Female , Humans , Male , Materials Testing , Middle Aged , Spinal Fusion , Spine/diagnostic imaging , Spine/surgery , Tomography, X-Ray Computed , Treatment Outcome
18.
Global Spine J ; 11(5): 679-685, 2021 Jun.
Article in English | MEDLINE | ID: mdl-32875910

ABSTRACT

STUDY DESIGN: Biomechanical study. OBJECTIVES: Failure of pedicle screws is a major problem in spinal surgery not only postoperatively, but also intraoperatively. The aim of this study was to evaluate whether cement augmentation may restore mounting of initially loosened pedicle screws. METHODS: A total of 14 osteoporotic or osteopenic human cadaveric vertebral bodies (L2)-according to quantitative computed tomography (QCT)-were instrumented on both sides by conventional pedicle screws and cement augmented on 1 side. In vitro fatigue loading (cranial-caudal sinusoidal, 0.5 Hz) with increasing peak force (100 N + 0.1 N/cycles) was applied until a screw head displacement of 5.4 mm (∼20°) was reached. After loosening, the nonaugmented screw was rescue augmented, and fatigue testing was repeated. RESULTS: The fatigue load reached 207.3 N for the nonaugmented screws and was significantly (P = .009) exceeded because of initial cement augmentation (300.6 N). The rescue augmentation after screw loosening showed a fatigue load of 370.1 N which was significantly higher (P < .001) compared with the nonaugmented screws. The impact of bone density on fatigue strength decreased from the nonaugmented to the augmented to the rescue-augmented screws and shows the greatest effect of cement augmentation on fatigue strength at low bone density. CONCLUSIONS: Rescue augmentation leads to similar or higher fatigue strengths compared with those of the initially augmented screws. Therefore, the cement augmentation of initially loosened pedicle screws is a promising option to restore adequate screw stability.

19.
Eur Spine J ; 30(1): 128-135, 2021 01.
Article in English | MEDLINE | ID: mdl-32940741

ABSTRACT

PURPOSE: Inadequate anchoring of pedicle screws in vertebrae with poor bone quality is a major problem in spine surgery. The aim was to evaluate whether a modified thread in the area of the pedicle could significantly improve the pedicle screw fatigue strength. METHODS: Fourteen human cadaveric vertebral bodies (L2 and L3) were used for in vitro testing. Bone density (BMD) was determined by quantitative computed tomography. Vertebral bodies were instrumented by standard pedicle screws with a constant double thread on the right pedicle and a partial doubling of the threads-quad thread-(cortical thread) in the area of the pedicle on the left pedicle. Pulsating sinusoidal, cyclic load (0.5 Hz) with increasing peak force (100 N + 0.1 N/cycles) was applied orthogonal to the screw axis. The baseline force remained constant (50 N). Fatigue test was terminated after exceeding 5.4-mm head displacement (~ 20° screw tilting). RESULTS: The mean fatigue load at failure was 264.9 N (1682 cycles) for the standard screws and was increased significantly to 324.7 N (2285 cycles) by the use of cortical threaded screws (p = 0.014). This effect is particularly evident in reduced BMD (standard thread 241.2 N vs. cortical thread 328.4 N; p = 0.016), whereas in the group of vertebrae with normal BMD no significant difference could be detected (standard thread 296.5 N vs. cortical thread 319.8 N; p = 0.463). CONCLUSIONS: Compared to a conventional pedicle screw, the use of a cortical threaded pedicle screw promises superior fatigue load in vertebrae with reduced bone quality.


Subject(s)
Pedicle Screws , Biomechanical Phenomena , Bone Density , Humans , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/surgery , Tomography, X-Ray Computed
20.
Global Spine J ; 11(7): 1089-1098, 2021 Sep.
Article in English | MEDLINE | ID: mdl-32744071

ABSTRACT

STUDY DESIGN: Biomechanical. OBJECTIVE: This study evaluates the biomechanical properties of lag-screws used in vertebral pincer fractures at the thoracolumbar junction. METHODS: Pincer fractures were created in 18 bisegmental human specimens. The specimens were assigned to three groups depending on their treatment perspective, either bolted, with the thread positioned in the cortical or cancellous bone, or control. The specimens were mounted in a servo-hydraulic testing machine and loaded with a 500 N follower load. They were consecutively tested in 3 different conditions: intact, fractured, and bolted/control. For each condition 10 cycles in extension/flexion, torsion, and lateral bending were applied. After each tested condition, a computed tomography (CT) scan was performed. Finally, an extension/flexion fatigue loading was applied to all specimens. RESULTS: Biomechanical results revealed a nonsignificant increase in stiffness in extension/flexion of the fractured specimens compared with the intact ones. For lateral bending and torsion, the stiffness was significantly lower. Compared with the fractured specimens, no changes in stiffness due to bolting were discovered. CT scans showed an increasing fracture gap during axial loading both in extension/flexion, torsion, and lateral bending in the control specimens. In bolted specimens, the anterior fragment was approximated, and the fracture gap nullified. This refers to both the cortical and the cancellous thread positions. CONCLUSION: The results of this study concerning the effect of lag-screws on pincer fractures appear promising. Though there was little effect on stiffness, CT scans reveal a bony contact in the bolted specimens, which is a requirement for bony healing.

SELECTION OF CITATIONS
SEARCH DETAIL
...