Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 32
Filter
1.
Circ Cardiovasc Interv ; : e013729, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38666384

ABSTRACT

BACKGROUND: Transverse aortic arch obstruction is a challenging lesion for which stent implantation provides a potentially important alternate therapy. The objectives were to evaluate the technical, procedural, and medium-to-long-term clinical outcomes of percutaneous stent implantation of transverse aortic arch obstruction. METHODS: This is a retrospective, multicenter study of transverse aortic arch stent implantation. Univariable and multivariable analyses were performed. RESULTS: Index catheterization included 187 stent implants in 146 patients. The median age is 14.3 years (interquartile range, 9.3-19), weight is 53 kg (30-69), and follow-up is 53 months (12-120). The most common stent design was open cell (n=90, 48%). Stents overlapped 142 arch vessels (37 carotid arteries) in 118 (81%) cases. Technical and procedural success rates were 100% and 88%, respectively. Lower weight (P=0.018), body surface area (P=0.013), and minimum-to-descending aortic diameter ratio (P<0.001) were associated with higher baseline aortic gradient. The residual gradient was inversely associated with implant and final dilation diameters (P<0.001). The combined incidence of aortic injury and stent-related complications was 14%. There were no reports of abnormal brain scans or stroke. Blood pressure cuff gradient, echocardiographic arch velocity, and hypertension rates improved within 1-year follow-up with increased antihypertensive medication use. Reintervention was reported in 60 (41%) patients at a median of 84 (22-148) months to first reintervention. On multivariable logistic regression, residual aortic gradient >10 mm Hg was associated with increased odds of reintervention at all time points when controlling for each final dilation diameter, weight, and minimum-to-descending aortic diameter ratio. CONCLUSIONS: Transverse aortic arch stent implantation has high rates of technical, procedural, and medium-to-long-term clinical success. Aortic gradient >10 mm Hg is associated with increased odds of reintervention at 1-year and most recent follow-ups. Open cell stent design was frequently used for its advantages in conformability, perfusion of arch vessels, low fracture rate, and the ability to perform effective angioplasty of side cells.

2.
J Am Coll Cardiol ; 83(14): 1310-1321, 2024 Apr 09.
Article in English | MEDLINE | ID: mdl-38569760

ABSTRACT

BACKGROUND: Transcatheter pulmonary valve replacement (TPVR) with the self-expanding Harmony valve (Medtronic) is an emerging treatment for patients with native or surgically repaired right ventricular outflow tract (RVOT) pulmonary regurgitation (PR). Limited data are available since U.S. Food and Drug Administration approval in 2021. OBJECTIVES: In this study, the authors sought to evaluate the safety and short-term effectiveness of self-expanding TPVR in a real-world experience. METHODS: This was a multicenter registry study of consecutive patients with native RVOT PR who underwent TPVR through April 30, 2022, at 11 U.S. CENTERS: The primary outcome was a composite of hemodynamic dysfunction (PR greater than mild and RVOT mean gradient >30 mm Hg) and RVOT reintervention. RESULTS: A total of 243 patients underwent TPVR at a median age of 31 years (Q1-Q3: 19-45 years). Cardiac diagnoses were tetralogy of Fallot (71%), valvular pulmonary stenosis (21%), and other (8%). Acute technical success was achieved in all but 1 case. Procedural serious adverse events occurred in 4% of cases, with no device embolization or death. Hospital length of stay was 1 day in 86% of patients. Ventricular arrhythmia prompting treatment occurred in 19% of cases. At a median follow-up of 13 months (Q1-Q3: 8-19 months), 98% of patients had acceptable hemodynamic function. Estimated freedom from the composite clinical outcome was 99% at 1 year and 96% at 2 years. Freedom from TPVR-related endocarditis was 98% at 1 year. Five patients died from COVID-19 (n = 1), unknown causes (n = 2), and bloodstream infection (n = 2). CONCLUSIONS: In this large multicenter real-world experience, short-term clinical and hemodynamic outcomes of self-expanding TPVR therapy were excellent. Ongoing follow-up of this cohort will provide important insights into long-term outcomes.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency , Pulmonary Valve , Humans , Adult , Pulmonary Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Cardiac Catheterization/adverse effects , Treatment Outcome , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve Insufficiency/etiology , Registries , Prosthesis Design , Retrospective Studies
3.
Circ Cardiovasc Interv ; : e013889, 2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38606564

ABSTRACT

BACKGROUND: Anatomic selection for Harmony valve implant is determined with the aid of a screening report and perimeter plot (PP) that depicts the perimeter-derived radius along the right ventricular outflow tract (RVOT) and projects device oversizing. The PP provides an estimation of suitability for implant, but its sensitivity as a screening method is unknown. This study was performed to describe anatomic features and outcomes in patients who underwent Harmony TPV25 implant despite a PP that predicted inadequate oversizing. METHODS: We reviewed RVOT anatomic features and measurements in patients who underwent transcatheter pulmonary valve replacement with the Harmony TPV25 device despite a PP that predicted inadequate oversizing. RESULTS: This study included 22 patients. There were no unsuccessful implants or adverse valve-related events. Anatomic features varied, but all patients fit into 1 of 3 anatomic types characterized by differences in RVOT dimensions. Type 1 patients (n=9) had a long RVOT with a choke point and a wide main pulmonary artery. Type 2 patients (n=6) had a short RVOT that was pyramidal in shape, with no choke point, and extensive main pulmonary artery lengthening/expansion during systole. Type 3 patients (n=7) had a short, bulbous main pulmonary artery with a choke point and an open pulmonary artery bifurcation. CONCLUSIONS: Transcatheter pulmonary valve replacement with the Harmony valve is feasible in some patients whose PP fit analysis predicts inadequate oversizing. All cases in this series fit into 1 of 3 anatomic patterns, which are not identified in the screening report. Implanters must review cases individually to assess the feasibility of the implant.

4.
Pediatr Cardiol ; 45(2): 323-330, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37707592

ABSTRACT

Therapies to support small infants in decompensated heart failure that are failing medical management are limited. We have used the hybrid approach, classically reserved for high-risk infants with single ventricle physiology, in patients with biventricular physiology with left ventricular failure. This approach secures systemic circulation, relieves left atrial hypertension, protects the pulmonary vasculature, and allows the right ventricle to support cardiac output. This approach can be used as a bridge to transplantation in select individuals. Infants without single ventricle congenital heart disease who were treated with the hybrid approach between 2008 and 2021 were included in analysis. Eight patients were identified. At the time of hybrid procedure, the median weight was 3.2 kg (range 2.4-3.6 kg) and the median age was 18 days (range 1-153 days). Seventy five percent were mechanically ventilated and 88% were on inotropic support. The median duration from hybrid procedure to transplant was 63 days (range 4-116 days). All patients experienced a good outcome (delisted for improvement or transplanted). The hybrid procedure is an appropriate therapeutic bridge to transplantation in a carefully selected subset of critically ill infants without single ventricle congenital heart disease in whom alternate therapies may confer increased risk for morbidity and mortality.


Subject(s)
Heart Defects, Congenital , Heart Transplantation , Hypoplastic Left Heart Syndrome , Infant , Humans , Treatment Outcome , Heart Ventricles , Retrospective Studies
5.
Catheter Cardiovasc Interv ; 102(6): 1078-1087, 2023 11.
Article in English | MEDLINE | ID: mdl-37925624

ABSTRACT

BACKGROUND: The Harmony TPV25 transcatheter pulmonary valve (Medtronic Inc.) is constructed with a self-expanding stent frame comprising six zigged nitinol wires sewn together and covered with knitted polyester fabric, with flared inflow and outflow ends and a porcine pericardial valve sutured to the central portion of the device. It was approved for treatment of pulmonary regurgitation after prior right ventricular outflow tract repair in 2021. Early outcomes of this procedure have been excellent, but little is known about valve durability or ultimate mechanisms of dysfunction. METHODS: We collected data on patients who underwent reintervention for TPV25 dysfunction and described findings related to distortion of the stent frame and tissue accumulation. RESULTS: We describe six patients who underwent valve-in-valve implant for TPV25 obstruction (peak catheterization gradient peak 28-73 mmHg) 10-28 months after implant. In all cases, there was tissue accumulation within the inflow and valve-housing segments of the device and deformation of the self-expanding valve frame characterized by variable circumferential narrowing at the junction between the valve housing and the inflow and outflow portions of the device, with additional geometric changes in all segments. All six patients underwent valve-in-valve implant that results in a final peak gradient ≤10 mmHg and no regurgitation. DISCUSSION: The occurrence of short-term Harmony TPV25 dysfunction in multiple patients with a similar appearance of frame distortion and tissue accumulation within the inflow and valve housing portions of the device suggests that this may be an important failure mechanism for this valve. Potential causes of the observed findings are discussed. It is possible to treat this mechanism of TPV25 dysfunction with valve-in-valve implant using balloon expandable transcatheter valves.


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Pulmonary Valve Insufficiency , Pulmonary Valve , Ventricular Outflow Obstruction, Right , Ventricular Outflow Obstruction , Humans , Swine , Animals , Heart Valve Prosthesis/adverse effects , Ventricular Outflow Obstruction/diagnostic imaging , Ventricular Outflow Obstruction/etiology , Ventricular Outflow Obstruction/surgery , Treatment Outcome , Cardiac Catheterization , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/etiology , Pulmonary Valve Insufficiency/surgery , Stents/adverse effects , Prosthesis Design
6.
Pediatr Transplant ; 28(2): e14636, 2023 Nov 05.
Article in English | MEDLINE | ID: mdl-37927113

ABSTRACT

BACKGROUND: Pulmonary vein stenosis (PVS) is a rare pediatric condition associated with significant mortality and morbidity. PVS in patients following heart transplant (HT) has not yet been described. METHODS: Patients who had clinically significant PVS following a heart transplant during the time period of April 1, 2013 to April 30, 2023, at Seattle Children's Hospital were identified. Clinically significant PVS was defined as an atretic vein or a vein with a gradient of ≥4 mmHg across at least one vein by echocardiogram or during cardiac catheterization. Patients who had a diagnosis of PVS prior to their transplant were excluded. A total of six patients were identified. We collected clinical data on these patients from their pre-transplant course to their most recent status. RESULTS: The median age at HT was 7.5 months (range 2-13 months). The median time from HT to diagnosis of PVS was 3.5 months (range 0.3-13 months). At the last follow-up, the patients had had two to five pulmonary vein interventions, and there were no mortalities. The donor-to-recipient weight and total cardiac volume (TCV) ratios were less than 2.0 in five of six of the patients. CONCLUSIONS: PVS is a rare complication that is associated with patients who undergo HT during infancy. PVS develops soon after HT and screening should occur accordingly. Interestingly, high donor-to-recipient weight and TCV ratios are not necessarily associated with the development of PVS. Further work will need to be performed in order to determine the significance of PVS in post-HT patients.

7.
J Perinatol ; 43(10): 1238-1244, 2023 10.
Article in English | MEDLINE | ID: mdl-37587183

ABSTRACT

OBJECTIVE: This study describes 3-year follow-up of 200 infants weighing ≥ 700 grams who underwent transcatheter patent ductus arteriosus (PDA) closure with the Amplatzer Piccolo™ Occluder. STUDY DESIGN: Between June 2017 and February 2019, 200 children were enrolled in this U.S. study (NCT03055858). PDA closure, survival, and device- or procedure-related events were evaluated. A total of 156 of the available 182 patients (86%) completed the study. RESULTS: The implant success rate was 95.5% (191/200). At 3 years, PDA closure was observed in 100% (33/33) of patients. Survival was >95% with 9 reported deaths. No deaths were adjudicated as device- or procedure-related. Notable events included aortic obstruction (2) requiring stent placement and tricuspid regurgitation (5), for which no interventions were required. CONCLUSIONS: This follow-up study demonstrates high rates of PDA closure, low serious complication rates, and survival > 95% at 3 years. The Amplatzer Piccolo™ Occluder is a safe and effective therapy for PDA treatment in premature infants. CLINICALTRIALS: gov identifier: NCT0305585.


Subject(s)
Ductus Arteriosus, Patent , Septal Occluder Device , Infant , Humans , Child , Follow-Up Studies , Ductus Arteriosus, Patent/surgery , Prospective Studies , Cardiac Catheterization/adverse effects , Septal Occluder Device/adverse effects , Treatment Outcome
8.
Circ Cardiovasc Interv ; 16(7): e012697, 2023 07.
Article in English | MEDLINE | ID: mdl-37417230

ABSTRACT

BACKGROUND: Covered stent (CS) use for the transcatheter treatment of coarctation of the aorta (COA) was first described over 20 years ago. The covered Cheatham-platinum stent received Food and Drug Administration approval for COA treatment in 2016. Data collected as part of the National Cardiovascular Data Registry IMPACT registry were evaluated for contemporary usage patterns of CS for the treatment of COA from 2016 to 2021. METHODS: Version 2 of the IMPACT registry was queried for all patients who underwent stent placement for treatment of COA from 2016 to 2021. Trends in CS use were evaluated by year and age of patient at the time of implant. Analysis was limited to clinical factors collected as part of the registry and was performed to identify factors associated with CS use. RESULTS: Data were available for 1989 case entries. Most patients (92%) received a single stent. The overall percentage of CS use in the cohort was 23% and remained consistent throughout the study period. The probability of CS use was significantly associated with increasing patient age at implant. Additional factors associated with CS use included smaller initial COA diameter, native COA, and the presence of a pseudoaneurysm. Procedural adverse event rates were low. CONCLUSIONS: CS use to treat COA was more common in adult patients and remained stable over the study period. Factors associated with CS use, including smaller COA diameter and aortic pseudoaneurysm, demonstrate the perceived value of CS as a tool to reduce the risk of aortic wall injury during treatment of COA.


Subject(s)
Aneurysm, False , Aortic Coarctation , Aortic Diseases , Adult , Humans , Aortic Coarctation/diagnostic imaging , Aortic Coarctation/therapy , Aortography , Treatment Outcome , Aneurysm, False/etiology , Stents/adverse effects , Aortic Diseases/complications
9.
Pediatr Cardiol ; 43(7): 1438-1443, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35274168

ABSTRACT

Determine outcomes of catheter intervention for aortic coarctation in infants. Aortic coarctation in infants following surgical repair and in high surgical risk native cases remains a challenging problem. Catheter intervention is an alternative to surgical intervention. Single-center, chart review of infants with biventricular anatomy who underwent coarctation stent placement or balloon angioplasty between 04/2004 and 04/2020. Outcomes of interest included change in aortic lumen diameter, peak gradient, number of re-interventions, time to re-intervention, and adverse events. Thirty-four patients were included in analysis, of those 16 underwent stent placement. Patients' mean age was 4.0 ± 3.0 months and weight of 5.3 ± 1.9 kg. Follow-up interval was 5.4 ± 5.1 years (0.2-16.1 years). Twelve (35%) patients underwent procedure due to ventricular dysfunction; the rest were for high resting gradient. Coarctation diameter increased from 2.4 ± 1.0 to 4.5 ± 1.3 (p < 0.01) and gradient decreased from 32.0 ± 18.4 mmHg to 9.2 ± 8.8 mmHg (p < 0.01). Thirteen (81%) of the stented patients required at least one re-intervention, at an average of 1.7 ± 3.2 years from the index procedure. Five (28%) of those undergoing balloon angioplasty required repeat intervention. There was no mortality due to the procedure and one late mortality. One patient had a serious procedural adverse event. On follow-up, 12 (35%) were on anti-hypertensive medications. Catheter intervention, including stent placement, for aortic coarctation in infants is feasible with an acceptable adverse event profile. Repeat interventions are common.


Subject(s)
Angioplasty, Balloon , Aortic Coarctation , Angioplasty, Balloon/adverse effects , Angioplasty, Balloon/methods , Antihypertensive Agents , Aortic Coarctation/diagnostic imaging , Aortic Coarctation/surgery , Follow-Up Studies , Humans , Infant , Recurrence , Retrospective Studies , Stents , Treatment Outcome
10.
J Am Coll Cardiol ; 79(1): 18-32, 2022 01 04.
Article in English | MEDLINE | ID: mdl-34991785

ABSTRACT

BACKGROUND: Transcatheter pulmonary valve (TPV) replacement (TPVR) has become the standard therapy for postoperative pulmonary outflow tract dysfunction in patients with a prosthetic conduit/valve, but there is limited information about risk factors for death or reintervention after this procedure. OBJECTIVES: This study sought to evaluate mid- and long-term outcomes after TPVR in a large multicenter cohort. METHODS: International registry focused on time-related outcomes after TPVR. RESULTS: Investigators submitted data for 2,476 patients who underwent TPVR and were followed up for 8,475 patient-years. A total of 95 patients died after TPVR, most commonly from heart failure (n = 24). The cumulative incidence of death was 8.9% (95% CI: 6.9%-11.5%) 8 years after TPVR. On multivariable analysis, age at TPVR (HR: 1.04 per year; 95% CI: 1.03-1.06 per year; P < 0.001), a prosthetic valve in other positions (HR: 2.1; 95% CI: 1.2-3.7; P = 0.014), and an existing transvenous pacemaker/implantable cardioverter-defibrillator (HR: 2.1; 95% CI: 1.3-3.4; P = 0.004) were associated with death. A total of 258 patients underwent TPV reintervention. At 8 years, the cumulative incidence of any TPV reintervention was 25.1% (95% CI: 21.8%-28.5%) and of surgical TPV reintervention was 14.4% (95% CI: 11.9%-17.2%). Risk factors for surgical reintervention included age (0.95 per year [95% CI: 0.93-0.97 per year]; P < 0.001), prior endocarditis (2.5 [95% CI: 1.4-4.3]; P = 0.001), TPVR into a stented bioprosthetic valve (1.7 [95% CI: 1.2-2.5]; P = 0.007), and postimplant gradient (1.4 per 10 mm Hg [95% CI: 1.2-1.7 per 10 mm Hg]: P < 0.001). CONCLUSIONS: These findings support the conclusion that survival and freedom from reintervention or surgery after TPVR are generally comparable to outcomes of surgical conduit/valve replacement across a wide age range.


Subject(s)
Heart Valve Prosthesis Implantation , Pulmonary Valve/surgery , Reoperation/statistics & numerical data , Adolescent , Adult , Age Factors , Child , Child, Preschool , Defibrillators, Implantable , Endocarditis/epidemiology , Female , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/mortality , Humans , Infant , Infant, Newborn , Male , Middle Aged , Pacemaker, Artificial , Registries , Young Adult
11.
Semin Pediatr Surg ; 30(6): 151123, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34930590

ABSTRACT

Patent ductus arteriosus (PDA) may be found in 0.1-0.2% of term infants, but the average incidence is at least five-fold higher in premature infants, correlating inversely with birth weight and gestational age. While not all patients with a PDA require treatment, the deleterious effects of persistent left-to-right shunting across the ductus can have important short- and long-term consequences. Medical and interventional approaches to PDA closure have evolved greatly in the past decade and add to the decision-making pathways. This article summarizes the pathophysiology of PDA and characterizes the medical, surgical and endovascular treatment approaches.


Subject(s)
Ductus Arteriosus, Patent , Ductus Arteriosus, Patent/surgery , Humans
12.
J Am Coll Cardiol ; 78(6): 575-589, 2021 08 10.
Article in English | MEDLINE | ID: mdl-34353535

ABSTRACT

BACKGROUND: Endocarditis has emerged as one of the most impactful adverse events after transcatheter pulmonary valve replacement (TPVR), but there is limited information about risk factors for and outcomes of this complication. OBJECTIVES: The purpose of this study was to evaluate risk factors for and outcomes of endocarditis in a large multicenter cohort. METHODS: The authors established an international registry focused on characterizing endocarditis after TPVR, including the incidence, risk factors, characteristics, and outcomes. RESULTS: Investigators submitted data for 2,476 patients who underwent TPVR between July 2005 and March 2020 and were followed for 8,475 patient-years. In total, 182 patients were diagnosed with endocarditis a median of 2.7 years after TPVR, for a cumulative incidence of 9.5% (95% CI: 7.9%-11.1%) at 5 years and 16.9% (95% CI: 14.2%-19.8%) at 8 years (accounting for competing risks: death, heart transplant, and explant) and an annualized incidence of 2.2 per 100 patient-years. Staphylococcus aureus and Viridans group Streptococcus species together accounted for 56% of cases. Multivariable analysis confirmed that younger age, a previous history of endocarditis, and a higher residual gradient were risk factors for endocarditis, but transcatheter pulmonary valve type was not. Overall, right ventricular outflow tract (RVOT) reintervention was less often to treat endocarditis than for other reasons, but valve explant was more often caused by endocarditis. Endocarditis was severe in 44% of patients, and 12 patients (6.6%) died, nearly all of whom were infected with Staphylococcus aureus. CONCLUSIONS: The incidence of endocarditis in this multicenter registry was constant over time and consistent with prior smaller studies. The findings of this study, along with ongoing efforts to understand and mitigate risk, will be critical to improve the lifetime management of patients with heart disease involving the RVOT. Although endocarditis can be a serious adverse outcome, TPVR remains an important tool in the management of RVOT dysfunction.


Subject(s)
Endocarditis , Heart Valve Prosthesis Implantation , Pulmonary Valve/surgery , Reoperation , Adult , Cardiac Catheterization/methods , Endocarditis/etiology , Endocarditis/microbiology , Endocarditis/mortality , Endocarditis/surgery , Female , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/statistics & numerical data , Humans , Incidence , International Cooperation , Male , Registries/statistics & numerical data , Reoperation/methods , Reoperation/statistics & numerical data , Staphylococcus aureus/isolation & purification , Ventricular Outflow Obstruction/etiology , Ventricular Outflow Obstruction/surgery , Viridans Streptococci/isolation & purification
13.
Catheter Cardiovasc Interv ; 98(5): 904-913, 2021 11 01.
Article in English | MEDLINE | ID: mdl-34398509

ABSTRACT

The Society for Cardiovascular Angiography and Interventions (SCAI) Think Tank is a collaborative venture that brings together interventional cardiologists, administrative partners, and select members of the cardiovascular industry community annually for high-level field-wide discussions. The 2021 Think Tank was organized into four parallel sessions reflective of the field of interventional cardiology: (a) coronary intervention, (b) endovascular medicine, (c) structural heart disease, and (d) congenital heart disease. Each session was moderated by a senior content expert and co-moderated by a member of SCAI's Emerging Leader Mentorship program. This document presents the proceedings to the wider cardiovascular community in order to enhance participation in this discussion, create additional dialog from a broader base, and thereby aid SCAI, the industry community and external stakeholders in developing specific action items to move these areas forward.


Subject(s)
Cardiologists , Cardiology , Heart Defects, Congenital , Angiography , Humans , Treatment Outcome
14.
J Am Coll Cardiol ; 77(1): 71-79, 2021 01 05.
Article in English | MEDLINE | ID: mdl-33413944

ABSTRACT

Transcatheter balloon valvuloplasty for the treatment of aortic and pulmonary valve stenosis was first described nearly 40 years ago. Since that time, the technique has been refined in an effort to optimize acute outcomes while reducing the long-term need for reintervention and valve replacement. Balloon pulmonary valvuloplasty is considered first-line therapy for pulmonary valve stenosis and generally results in successful relief of valvar obstruction. Larger balloon to annulus (BAR) diameter ratios can increase the risk for significant valvar regurgitation. However, the development of regurgitation resulting in right ventricular dilation and dysfunction necessitating pulmonary valve replacement is uncommon in long-term follow-up. Balloon aortic valvuloplasty has generally been the first-line therapy for aortic valve stenosis, although some contemporary studies have documented improved outcomes following surgical valvuloplasty in a subset of patients who achieve tri-leaflet valve morphology following surgical repair. Over time, progressive aortic regurgitation is common and frequently results in the need for aortic valve replacement. Neonates with critical aortic valve stenosis remain a particularly high-risk group. More contemporary data suggest that acutely achieving an aortic valve gradient <35 mm Hg with mild aortic regurgitation may improve long-term valve performance and reduce the need for valve replacement. Continued study will help to further improve outcomes and reduce the need for future reinterventions.


Subject(s)
Aortic Valve Stenosis/therapy , Balloon Valvuloplasty , Heart Defects, Congenital/therapy , Pulmonary Valve Stenosis/therapy , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery , Aortic Valve Stenosis/etiology , Balloon Valvuloplasty/adverse effects , Heart Defects, Congenital/complications , Heart Valve Prosthesis Implantation , Humans , Pulmonary Valve/surgery , Pulmonary Valve Insufficiency/etiology , Pulmonary Valve Stenosis/etiology
15.
J Am Coll Cardiol ; 76(24): 2847-2858, 2020 12 15.
Article in English | MEDLINE | ID: mdl-33303074

ABSTRACT

BACKGROUND: There are limited published data focused on outcomes of transcatheter pulmonary valve replacement (TPVR) with either a Sapien XT or Sapien 3 (S3) valve. OBJECTIVES: This study sought to report short-term outcomes in a large cohort of patients who underwent TPVR with either a Sapien XT or S3 valve. METHODS: Data were entered retrospectively into a multicenter registry for patients who underwent attempted TPVR with a Sapien XT or S3 valve. Patient-related, procedural, and short-term outcomes data were characterized overall and according to type of right ventricular outflow tract (RVOT) anatomy. RESULTS: Twenty-three centers enrolled a total of 774 patients: 397 (51%) with a native/patched RVOT; 183 (24%) with a conduit; and 194 (25%) with a bioprosthetic valve. The S3 was used in 78% of patients, and the XT was used in 22%, with most patients receiving a 29-mm (39%) or 26-mm (34%) valve. The implant was technically successful in 754 (97.4%) patients. Serious adverse events were reported in 67 patients (10%), with no difference between RVOT anatomy groups. Fourteen patients underwent urgent surgery. Nine patients had a second valve implanted. Among patients with available data, tricuspid valve injury was documented in 11 (1.7%), and 9 others (1.3%) had new moderate or severe regurgitation 2 grades higher than pre-implantation, for 20 (3.0%) total patients with tricuspid valve complications. Valve function at discharge was excellent in most patients, but 58 (8.5%) had moderate or greater pulmonary regurgitation or maximum Doppler gradients >40 mm Hg. During limited follow-up (n = 349; median: 12 months), 9 patients were diagnosed with endocarditis, and 17 additional patients underwent surgical valve replacement or valve-in-valve TPVR. CONCLUSIONS: Acute outcomes after TPVR with balloon-expandable valves were generally excellent in all types of RVOT. Additional data and longer follow-up will be necessary to gain insight into these issues.


Subject(s)
Endovascular Procedures/statistics & numerical data , Heart Valve Prosthesis Implantation/statistics & numerical data , Heart Valve Prosthesis , Pulmonary Valve , Registries , Adolescent , Adult , Bioprosthesis , Child , Endovascular Procedures/instrumentation , Endovascular Procedures/methods , Female , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/methods , Humans , Male , Middle Aged , Retrospective Studies , Young Adult
16.
Catheter Cardiovasc Interv ; 96(6): 1258-1265, 2020 11.
Article in English | MEDLINE | ID: mdl-32840956

ABSTRACT

The society for cardiovascular angiography and interventions (SCAI) think tank is a collaborative venture that brings together interventional cardiologists, administrative partners, and select members of the cardiovascular industry community for high-level field-wide discussions. The 2020 think tank was organized into four parallel sessions reflective of the field of interventional cardiology: (a) coronary intervention, (b) endovascular medicine, (c) structural heart disease, and (d) congenital heart disease (CHD). Each session was moderated by a senior content expert and co-moderated by a member of SCAI's emerging leader mentorship program. This document presents the proceedings to the wider cardiovascular community in order to enhance participation in this discussion, create additional dialogue from a broader base, and thereby aid SCAI and the industry community in developing specific action items to move these areas forward.


Subject(s)
Cardiac Catheterization/trends , Cardiology/trends , Coronary Angiography/trends , Heart Diseases/diagnostic imaging , Heart Diseases/therapy , Percutaneous Coronary Intervention/trends , Diffusion of Innovation , Heart Diseases/physiopathology , Humans
17.
Catheter Cardiovasc Interv ; 96(6): 1266-1276, 2020 11.
Article in English | MEDLINE | ID: mdl-32433821

ABSTRACT

OBJECTIVES: Characterize the safety and effectiveness of the Amplatzer Piccolo Occluder for patent ductus arteriosus (PDA) closure. BACKGROUND: The presence of a hemodynamically significant PDA has been associated with an increased risk of morbidity and mortality in children born premature. METHODS: This was a single arm, prospective, multicenter, non-randomized study to evaluate the Amplatzer Piccolo Occluder to treat PDA in patients ≥700 g. From June 2017 to February 2019, 200 patients were enrolled at nine centers, with 100 patients weighing ≤2 kg. Primary effectiveness endpoint was the rate of PDA closure at 6-month follow-up. Primary safety endpoint was the rate of major complications through 6 months. Secondary endpoint was rate of significant pulmonary or aortic obstruction through 6 months' follow-up. RESULTS: The implant success rate was 95.5% (191/200) overall and 99% in patients ≤2 kg (99/100). The primary effectiveness endpoint was achieved in 99.4% of implanted patients. Four patients experienced a primary safety endpoint event (2 transfusions, 1 hemolysis, and 1 aortic obstruction). There were no branch pulmonary artery obstructions. Five patients, all ≤2 kg, were noted to have worsening of tricuspid regurgitation (TR) after the procedure. None of the TR incidences manifested clinically. The Amplatzer Piccolo Occluder received FDA approval in January 2019 and became the first device approved for PDA closure in patients ≥700 g. CONCLUSIONS: This study supports the safety and effectiveness of the Amplatzer Piccolo Occluder, particularly in patients between 700 g and 2 kg where there is currently a significant unmet need in the United States. ClinicalTrials.gov identifier: NCT03055858.


Subject(s)
Cardiac Catheterization/instrumentation , Ductus Arteriosus, Patent/therapy , Infant, Extremely Premature , Infant, Very Low Birth Weight , Septal Occluder Device , Birth Weight , Cardiac Catheterization/adverse effects , Coronary Circulation , Ductus Arteriosus, Patent/diagnostic imaging , Ductus Arteriosus, Patent/physiopathology , Female , Gestational Age , Hemodynamics , Humans , Infant, Newborn , Male , Prospective Studies , Prosthesis Design , Time Factors , Treatment Outcome , United States
18.
J Invasive Cardiol ; 32(5): E103-E109, 2020 05.
Article in English | MEDLINE | ID: mdl-32269177

ABSTRACT

BACKGROUND: The novel coronavirus (COVID-19) pandemic has placed severe stress on healthcare systems around the world. There is limited information on current practices in pediatric cardiac catheterization laboratories in the United States (US). OBJECTIVES: To describe current practice patterns and make recommendations regarding potential resource allocation for congenital cardiac catheterization during the COVID-19 pandemic. METHODS: A web-based survey was distributed regarding case candidacy and catheterization laboratory preparedness. Centers were categorized based on the current degree of disease burden in that community (as of April 1, 2020). Data and consensus opinion were utilized to develop recommendations. RESULTS: Respondents belonged to 56 unique US centers, with 27 (48.2%) located in counties with a high number of COVID-19 cases. All centers have canceled elective procedures. There was relative uniformity (>88% agreement) among centers as to which procedures were considered elective. To date, only three centers have performed a catheterization on a confirmed COVID-19 positive patient. Centers located in areas with a higher number of COVID-9 cases have been more involved in a simulation of donning and doffing personal protective equipment (PPE) than low-prevalence centers (46.7% vs 10.3%, respectively; P<.001). Currently, only a small fraction of operators has been reassigned to provide clinical services outside their scope of practice. CONCLUSIONS: At this stage in the COVID-19 pandemic, pediatric/congenital catheterization laboratories have dramatically reduced case volumes. This document serves to define current patterns and provides guidance and recommendations on the preservation and repurposing of resources to help pediatric cardiac programs develop strategies for patient care during this unprecedented crisis.


Subject(s)
Cardiac Catheterization/methods , Coronavirus Infections/complications , Health Care Rationing/methods , Pneumonia, Viral/complications , Betacoronavirus , COVID-19 , Child , Coronavirus Infections/epidemiology , Decision Making , Heart Defects, Congenital , Humans , Intensive Care Units, Pediatric , Pandemics , Personal Protective Equipment , Pneumonia, Viral/epidemiology , Resource Allocation , SARS-CoV-2 , Surveys and Questionnaires , United States/epidemiology
19.
Catheter Cardiovasc Interv ; 94(4): 618-624, 2019 Oct 01.
Article in English | MEDLINE | ID: mdl-31424167

ABSTRACT

OBJECTIVES: To define patient and ventricular size parameters to guide Impella device (Abiomed, Inc., Danvers, MA) placement for mechanical circulatory support (MCS) in small pediatric patients (10-30 kg). BACKGROUND: There are few options for MCS in children, and there are no data on minimum patient size requirements for placement of the Impella 2.5 device. METHODS: This was a multicenter study of echocardiographic and magnetic resonance imaging (MRI) derived dimensions of the left ventricle (LV) length and ascending aorta used to define minimum size parameters that are necessary for the placement of the Impella catheter. RESULTS: Data were collected from 44 cardiac MRIs conducted in healthy pediatric patients and 39 echocardiograms performed in pediatric patients with cardiomyopathy prior to surgical ventricular assist device (VAD) placement. The Impella 2.5 catheter is 7.5 cm from the pigtail to the aortic annulus marker, thus requiring an LV apical length of 7.5 cm to allow the device to function in an unconstrained fashion. In the cohort of patients undergoing consideration for VAD placement, a minimum LV length of 7.5 cm corresponded to a height of 122 cm, weight of 23 kg, and body surface area (BSA) of 0.89 m2 . In the MRI cohort, this corresponded to a height of 121 cm, weight of 23.9 kg, and BSA of 0.89 m2 . CONCLUSION: MCS with Impella devices is feasible in pediatric patients. This study defines anthropomorphic and anatomic measurements to guide providers in patient selection for MCS using the Impella devices.


Subject(s)
Body Height , Body Weight , Clinical Decision-Making , Heart Failure/therapy , Heart-Assist Devices , Prosthesis Implantation/instrumentation , Ventricular Function, Left , Body Surface Area , Child , Child, Preschool , Echocardiography , Female , Heart Failure/diagnostic imaging , Heart Failure/physiopathology , Humans , Infant , Magnetic Resonance Imaging , Male , Patient Selection , Prosthesis Design , Prosthesis Implantation/adverse effects , Recovery of Function , Retrospective Studies , Treatment Outcome , United States
20.
Catheter Cardiovasc Interv ; 93(3): 474-480, 2019 02 15.
Article in English | MEDLINE | ID: mdl-30419603

ABSTRACT

OBJECTIVES: This study describes procedural and 1-year outcomes of the 16 mm Melody PB1016 valve in patients with dysfunctional RVOT conduits. BACKGROUND: The Melody PB1016 is a standard Melody valve produced from a 16 mm bovine jugular vein and is intended for deployment up to 20 mm. METHODS: This is a prospective, non-randomized, multicenter study of the procedural and short-term outcomes of Melody PB1016 TPV replacement within dysfunctional RVOT conduits. Data from eight centers were included in the analysis. RESULTS: During the study period, 39 patients underwent attempted Melody TPVR. Of the 39 patients, 30 underwent successful Melody TPVR. The majority of patients underwent placement of one or more stents prior to TPVR. There was a significant reduction in peak conduit pressure gradient following TPVR (38 mmHg vs. 11 mmHg, P < 0.001). There were three cases of confined conduit tears successfully treated with covered stents or the valve itself. Repeat catheterization was performed in one patient for early re-obstruction that was successfully treated with balloon valvuloplasty. At recent follow-up, there were no cases of more than mild valve regurgitation and the mean pulmonary valve gradient by echocardiogram remained reduced relative to pre-TPVR implant measurements (33.5 mmHg vs. 15.2 mmHg). There were no cases of valve stent fracture or endocarditis reported at the 1-year follow-up. CONCLUSIONS: Our analysis of TPVR with the PB1016 valve in RVOT conduits showed it to be safe and effective and can be performed in a wide range of conduit sizes with preserved valve function. ClinicalTrials.gov Identifier: NCT02347189.


Subject(s)
Bioprosthesis , Cardiac Catheterization/instrumentation , Cardiac Surgical Procedures/adverse effects , Heart Defects, Congenital/surgery , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis , Jugular Veins/transplantation , Pulmonary Valve Insufficiency/surgery , Pulmonary Valve/surgery , Stents , Adolescent , Adult , Animals , Canada , Cardiac Catheterization/adverse effects , Cattle , Child , Europe , Female , Heart Defects, Congenital/physiopathology , Heart Valve Prosthesis Implantation/adverse effects , Heterografts , Humans , Male , Prospective Studies , Prosthesis Design , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/physiopathology , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/etiology , Pulmonary Valve Insufficiency/physiopathology , Recovery of Function , Treatment Outcome , United States , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...