Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
1.
Intensive Care Med ; 50(5): 697-711, 2024 May.
Article in English | MEDLINE | ID: mdl-38598124

ABSTRACT

PURPOSE: Patients with hematological malignancies are at high risk for life-threatening complications. To date, little attention has been paid to the impact of hyperoxemia and excess oxygen use on mortality. The aim of this study was to investigate the association between partial pressure of arterial oxygen (PaO2) and 28-day mortality in critically ill patients with hematologic malignancies. METHODS: Data from three international cohorts (Europe, Canada, Oceania) of patients who received respiratory support (noninvasive ventilation, high-flow nasal cannula, invasive mechanical ventilation) were obtained. We used mixed-effect Cox models to investigate the association between day one PaO2 or excess oxygen use (inspired fraction of oxygen ≥ 0.6 with PaO2 > 100 mmHg) on day-28 mortality. RESULTS: 11,249 patients were included. On day one, 5716 patients (50.8%) had normoxemia (60 ≤ PaO2 ≤ 100 mmHg), 1454 (12.9%) hypoxemia (PaO2 < 60 mmHg), and 4079 patients (36.3%) hyperoxemia (PaO2 > 100 mmHg). Excess oxygen was used in 2201 patients (20%). Crude day-28 mortality rate was 40.6%. There was a significant association between PaO2 and day-28 mortality with a U-shaped relationship (p < 0.001). Higher PaO2 levels (> 100 mmHg) were associated with day-28 mortality with a dose-effect relationship. Subgroup analyses showed an association between hyperoxemia and mortality in patients admitted with neurological disorders; however, the opposite relationship was seen across those admitted with sepsis and neutropenia. Excess oxygen use was also associated with subsequent day-28 mortality (adjusted hazard ratio (aHR) [95% confidence interval (CI)]: 1.11[1.04-1.19]). This result persisted after propensity score analysis (matched HR associated with excess oxygen:1.31 [1.20-1.1.44]). CONCLUSION: In critically-ill patients with hematological malignancies, exposure to hyperoxemia and excess oxygen use were associated with increased mortality, with variable magnitude across subgroups. This might be a modifiable factor to improve mortality.


Subject(s)
Critical Illness , Hematologic Neoplasms , Oxygen , Humans , Hematologic Neoplasms/mortality , Hematologic Neoplasms/therapy , Hematologic Neoplasms/complications , Hematologic Neoplasms/blood , Male , Critical Illness/mortality , Female , Middle Aged , Aged , Oxygen/blood , Canada/epidemiology , Proportional Hazards Models , Europe/epidemiology , Adult , Respiration, Artificial/statistics & numerical data , Hyperoxia/mortality , Hyperoxia/etiology
2.
J Vis Exp ; (201)2023 Nov 03.
Article in English | MEDLINE | ID: mdl-37982511

ABSTRACT

The diaphragm is the main component of the respiratory muscle pump. Diaphragm dysfunction can cause dyspnea and exercise intolerance, and predisposes affected individuals to respiratory failure. In mechanically ventilated patients, the diaphragm is susceptible to atrophy and dysfunction through disuse and other mechanisms. This contributes to failure to wean and poor long-term clinical outcomes. Point-of-care ultrasound provides a valid and reproducible method for evaluating diaphragm thickness and contractile activity (thickening fraction during inspiration) that can be readily employed by clinicians and researchers alike. This article presents best practices for measuring diaphragm thickness and quantifying diaphragm thickening during tidal breathing or maximal inspiration. Once mastered, this technique can be used to diagnose and prognosticate diaphragm dysfunction, and guide and monitor response to treatment over time in both healthy individuals and acute or chronically ill patients.


Subject(s)
Diaphragm , Point-of-Care Systems , Humans , Diaphragm/diagnostic imaging , Thorax , Respiratory Muscles , Point-of-Care Testing
3.
Respir Care ; 68(12): 1736-1747, 2023 Nov 25.
Article in English | MEDLINE | ID: mdl-37875317

ABSTRACT

Diaphragm inactivity during invasive mechanical ventilation leads to diaphragm atrophy and weakness, hemodynamic instability, and ventilatory heterogeneity. Absent respiratory drive and effort can, therefore, worsen injury to both lung and diaphragm and is a major cause of failure to wean. Phrenic nerve stimulation (PNS) can maintain controlled levels of diaphragm activity independent of intrinsic drive and as such may offer a promising approach to achieving lung and diaphragm protective ventilatory targets. Whereas PNS has an established role in the management of chronic respiratory failure, there is emerging interest in how its multisystem putative benefits may be temporarily harnessed in the management of invasively ventilated patients with acute respiratory failure.


Subject(s)
Electric Stimulation Therapy , Respiratory Distress Syndrome , Respiratory Insufficiency , Humans , Phrenic Nerve , Respiration, Artificial , Diaphragm/injuries , Respiratory Insufficiency/etiology , Respiratory Insufficiency/therapy
5.
Am J Respir Crit Care Med ; 208(1): 111-112, 2023 Jul 01.
Article in English | MEDLINE | ID: mdl-37159944
6.
Am J Respir Crit Care Med ; 207(10): 1275-1282, 2023 05 15.
Article in English | MEDLINE | ID: mdl-36917765

ABSTRACT

Diaphragm neurostimulation consists of placing electrodes directly on or in proximity to the phrenic nerve(s) to elicit diaphragmatic contractions. Since its initial description in the 18th century, indications have shifted from cardiopulmonary resuscitation to long-term ventilatory support. Recently, the technical development of devices for temporary diaphragm neurostimulation has opened up the possibility of a new era for the management of mechanically ventilated patients. Combining positive pressure ventilation with diaphragm neurostimulation offers a potentially promising new approach to the delivery of mechanical ventilation which may benefit multiple organ systems. Maintaining diaphragm contractions during ventilation may attenuate diaphragm atrophy and accelerate weaning from mechanical ventilation. Preventing atelectasis and preserving lung volume can reduce lung stress and strain and improve homogeneity of ventilation, potentially mitigating ventilator-induced lung injury. Furthermore, restoring the thoracoabdominal pressure gradient generated by diaphragm contractions may attenuate the drop in cardiac output induced by positive pressure ventilation. Experimental evidence suggests diaphragm neurostimulation may prevent neuroinflammation associated with mechanical ventilation. This review describes the historical development and evolving approaches to diaphragm neurostimulation during mechanical ventilation and surveys the potential mechanisms of benefit. The review proposes a research agenda and offers perspectives for the future of diaphragm neurostimulation assisted mechanical ventilation for critically ill patients.


Subject(s)
Diaphragm , Respiration, Artificial , Humans , Diaphragm/physiology , Critical Illness/therapy , Positive-Pressure Respiration , Respiration
7.
Am J Respir Crit Care Med ; 207(11): 1441-1450, 2023 06 01.
Article in English | MEDLINE | ID: mdl-36705985

ABSTRACT

ICU clinicians rely on bedside physiological measurements to inform many routine clinical decisions. Because deranged physiology is usually associated with poor clinical outcomes, it is tempting to hypothesize that manipulating and intervening on physiological parameters might improve outcomes for patients. However, testing these hypotheses through mathematical models of the relationship between physiology and outcomes presents a number of important methodological challenges. These models reflect the theories of the researcher and can therefore be heavily influenced by one's assumptions and background beliefs. Model building must therefore be approached with great care and forethought, because failure to consider relevant sources of measurement error, confounding, coupling, and time dependency or failure to assess the direction of causality for associations of interest before modeling may give rise to spurious results. This paper outlines the main challenges in analyzing and interpreting these models and offers potential solutions to address these challenges.


Subject(s)
Respiration, Artificial , Respiratory Insufficiency , Humans , Respiration, Artificial/methods , Respiratory Insufficiency/etiology , Intensive Care Units
10.
Curr Opin Crit Care ; 28(3): 348-359, 2022 06 01.
Article in English | MEDLINE | ID: mdl-35275878

ABSTRACT

PURPOSE OF REVIEW: Extracorporeal membrane oxygenation (ECMO) offers advanced mechanical support to patients with severe acute respiratory and/or cardiac failure. Ensuring an adequate therapeutic approach as well as prevention of ECMO-associated complications, by means of timely liberation, forms an essential part of standard ECMO care and is only achievable through continuous monitoring and evaluation. This review focus on the cardiorespiratory monitoring tools that can be used to assess and titrate adequacy of ECMO therapy; as well as methods to assess readiness to wean and/or discontinue ECMO support. RECENT FINDINGS: Surrogates of tissue perfusion and near infrared spectroscopy are not standards of care but may provide useful information in select patients. Echocardiography allows to determine cannulas position, evaluate cardiac structures, and function, and diagnose complications. Respiratory monitoring is mandatory to achieve lung protective ventilation and identify early lung recovery, surrogate measurements of respiratory effort and ECMO derived parameters are invaluable in optimally managing ECMO patients. SUMMARY: Novel applications of existing monitoring modalities alongside evolving technological advances enable the advanced monitoring required for safe delivery of ECMO. Liberation trials are necessary to minimize time sensitive ECMO related complications; however, these have yet to be standardized.


Subject(s)
Extracorporeal Membrane Oxygenation , Heart Failure , Echocardiography , Extracorporeal Membrane Oxygenation/methods , Humans , Monitoring, Physiologic , Respiration, Artificial
12.
Perfusion ; 37(8): 819-824, 2022 11.
Article in English | MEDLINE | ID: mdl-34254557

ABSTRACT

INTRODUCTION: The Crescent® is a recently introduced dual lumen cannula by which veno-venous extracorporeal membrane oxygenation (VV ECMO) is delivered. It has a number of features that enhance its ease of placement, pressure-flow dynamics and may reduce catheter-related complication rates. METHODS: We present the first case series of its kind analysing this device by means of a retrospective observational study of prospectively collected data from the first year of its use in a high volume severe acute respiratory failure centre (Glenfield, UK). We compare complication rates of the Crescent®, with data from the international ELSO database and our own historic centre data and discuss subjective clinician experience of introducing this device. RESULTS: Over the first 12 months of its use (23/09/2019-23/09/2020), 54 patients were cannulated using a Crescent® catheter. There were no serious/life-threatening adverse events and a low number of minor cannula-related complications. Subjectively users found it has a number of advantages over other devices and configurations, not captured within current data collection frameworks. CONCLUSION: The Crescent® is a safe and effective device by which to deliver VV ECMO support to patients with severe acute respiratory failure.


Subject(s)
Extracorporeal Membrane Oxygenation , Respiratory Distress Syndrome , Respiratory Insufficiency , Adult , Humans , Extracorporeal Membrane Oxygenation/adverse effects , Cannula , Respiratory Distress Syndrome/therapy , Catheters , Respiratory Insufficiency/therapy , Respiratory Insufficiency/etiology
15.
J Intensive Care Soc ; 18(3): 198-205, 2017 Aug.
Article in English | MEDLINE | ID: mdl-29118831

ABSTRACT

BACKGROUND: Assessment of competence in basic critical care echocardiography is complex. Competence relies on not only imaging accuracy but also interpretation and appropriate management decisions. The experience to achieve these skills, real-time, is likely more than required for imaging accuracy alone. We aimed to assess the feasibility of using simulation to assess number of studies required to attain competence in basic critical care echocardiography. METHODS: This is a prospective pilot study recruiting trainees at various degrees of experience in basic critical care echocardiography using experts as reference standard. We used high fidelity simulation to assess speed and accuracy using total time taken, total position difference and total angle difference across the basic acoustic windows. Interpretation and clinical application skills were assessed using a clinical scenario. 'Cut-off' values for number of studies required for competence were estimated. RESULTS: Twenty-seven trainees and eight experts were included. The subcostal view was achieved quickest by trainees (median 23 s, IQR 19-37). Eighty-seven percent of trainees did not achieve accuracy across all views; 81% achieved accuracy with the parasternal long axis and the least accurate was the parasternal short axis (44% of trainees). Fewer studies were required to be considered competent with imaging acquisition compared with competence in correct interpretation and integration (15 vs. 40 vs. 50, respectively). DISCUSSION: The use of echocardiography simulation to determine competence in basic critical care echocardiography is feasible. Competence in image acquisition appears to be achieved with less experience than correct interpretation and correct management decisions. Further studies are required.

SELECTION OF CITATIONS
SEARCH DETAIL