Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 59
Filter
1.
ACS Appl Nano Mater ; 7(12): 14146-14153, 2024 Jun 28.
Article in English | MEDLINE | ID: mdl-38962509

ABSTRACT

We present CdSe@CdS nanorods coated with a redox-active polydopamine (PDA) layer functionalized with cobaloxime-derived photocatalysts for efficient solar-driven hydrogen evolution in aqueous environments. The PDA-coating provides reactive groups for the functionalization of the nanorods with different molecular catalysts, facilitates charge separation and transfer of electrons from the excited photosensitizer to the catalyst, and reduces photo-oxidation of the photosensitizer. X-ray photoelectron spectroscopy (XPS) confirms the successful functionalization of the nanorods with cobalt-based catalysts, whereas the catalyst loading per nanorod is quantified by total reflection X-ray fluorescence spectrometry (TXRF). A systematic comparison of different types of cobalt-based catalysts was carried out, and their respective performance was analyzed in terms of the number of nanorods and the amount of catalyst in each sample [turnover number, (TON)]. This study shows that the performance of these multicomponent photocatalysts depends strongly on the catalyst loading and less on the specific structure of the molecular catalyst. Lower catalyst loading is advantageous for increasing the TON because the catalysts compete for a limited number of charge carriers at the nanoparticle surface. Therefore, increasing the catalyst loading relative to the absolute amount of hydrogen produced does not lead to a steady increase in the photocatalytic activity. In our work, we provide insights into how the performance of a multicomponent photocatalytic system is determined by the intricate interplay of its components. We identify the stable attachment of the catalyst and the ratio between the catalyst and photosensitizer as critical parameters that must be fine-tuned for optimal performance.

2.
Nature ; 2024 Jul 17.
Article in English | MEDLINE | ID: mdl-39020167

ABSTRACT

A single dose of psilocybin, a psychedelic that acutely causes distortions of space-time perception and ego dissolution, produces rapid and persistent therapeutic effects in human clinical trials1-4. In animal models, psilocybin induces neuroplasticity in cortex and hippocampus5-8. It remains unclear how human brain network changes relate to subjective and lasting effects of psychedelics. Here we tracked individual-specific brain changes with longitudinal precision functional mapping (roughly 18 magnetic resonance imaging visits per participant). Healthy adults were tracked before, during and for 3 weeks after high-dose psilocybin (25 mg) and methylphenidate (40 mg), and brought back for an additional psilocybin dose 6-12 months later. Psilocybin massively disrupted functional connectivity (FC) in cortex and subcortex, acutely causing more than threefold greater change than methylphenidate. These FC changes were driven by brain desynchronization across spatial scales (areal, global), which dissolved network distinctions by reducing correlations within and anticorrelations between networks. Psilocybin-driven FC changes were strongest in the default mode network, which is connected to the anterior hippocampus and is thought to create our sense of space, time and self. Individual differences in FC changes were strongly linked to the subjective psychedelic experience. Performing a perceptual task reduced psilocybin-driven FC changes. Psilocybin caused persistent decrease in FC between the anterior hippocampus and default mode network, lasting for weeks. Persistent reduction of hippocampal-default mode network connectivity may represent a neuroanatomical and mechanistic correlate of the proplasticity and therapeutic effects of psychedelics.

3.
Animals (Basel) ; 14(13)2024 Jul 07.
Article in English | MEDLINE | ID: mdl-38998113

ABSTRACT

In calf fattening, housing climate conditions are essential for optimal performance and welfare. Validated methods to measure the long-term housing climate are lacking. The present study investigated climate parameters for 14 weeks in Swiss calf fattening housing with two different ammonia (NH3) sensors: six stationary sensors (Dräger Polytron 8100) were installed at animal level and four mobile sensors (Dräger x-AM 5100) were attached to the calves' heads. Temperature, relative humidity, and carbon dioxide (CO2) concentrations were recorded by two stationary data loggers (testo 160 IAQ). Data were analyzed descriptively, and 4 h mean values of maximum NH3 concentrations of mobile and stationary sensors were compared using the Wilcoxon test for paired data. The 4 h mean values of temperature, relative humidity, and CO2 concentrations and the 4 h mean values of maximum NH3 concentrations of stationary and mobile sensors were analyzed by ANOVA in two linear models. The overall 4 h mean of maximum NH3 concentrations ranged between 5.9-9.4 ppm for measurements of stationary sensors and between 11.3-14.7 ppm for measurements of mobile sensors. The NH3 concentrations measured by mobile sensors showed significantly higher peak values and more fluctuations. Additionally, an interaction effect was observed between the NH3 concentrations measured by either sensor and CO2 concentrations (p < 0.01 (mobile sensors); p < 0.0001 (stationary sensors), temperature values (p < 0.0001 (both sensors)), and relative humidity (p < 0.0001 (both sensors)). The measurements of the implemented method showed that corresponding housing climate parameters fluctuated strongly, and NH3 reached high peak values. Validated measurement methods might allow for a detailed assessment of the housing climate in practice, and for further research on suitable management methods for housing climate optimization in the future.

5.
bioRxiv ; 2023 Nov 01.
Article in English | MEDLINE | ID: mdl-37961636

ABSTRACT

The characterization of individual functional brain organization with Precision Functional Mapping has provided important insights in recent years in adults. However, little is known about the ontogeny of inter-individual differences in brain functional organization during human development, but precise characterization of systems organization during periods of high plasticity might be most influential towards discoveries promoting lifelong health. Collecting and analyzing precision fMRI data during early development has unique challenges and emphasizes the importance of novel methods to improve data acquisition, processing, and analysis strategies in infant samples. Here, we investigate the applicability of two such methods from adult MRI research, multi-echo (ME) data acquisition and thermal noise removal with Noise reduction with distribution corrected principal component analysis (NORDIC), in precision fMRI data from three newborn infants. Compared to an adult example subject, T2* relaxation times calculated from ME data in infants were longer and more variable across the brain, pointing towards ME acquisition being a promising tool for optimizing developmental fMRI. The application of thermal denoising via NORDIC increased tSNR and the overall strength of functional connections as well as the split-half reliability of functional connectivity matrices in infant ME data. While our findings related to NORDIC denoising are coherent with the adult literature and ME data acquisition showed high promise, its application in developmental samples needs further investigation. The present work reveals gaps in our understanding of the best techniques for developmental brain imaging and highlights the need for further developmentally-specific methodological advances and optimizations, towards precision functional imaging in infants.

6.
Trends Cogn Sci ; 27(12): 1135-1149, 2023 12.
Article in English | MEDLINE | ID: mdl-37838614

ABSTRACT

Although each of us was once a baby, infant consciousness remains mysterious and there is no received view about when, and in what form, consciousness first emerges. Some theorists defend a 'late-onset' view, suggesting that consciousness requires cognitive capacities which are unlikely to be in place before the child's first birthday at the very earliest. Other theorists defend an 'early-onset' account, suggesting that consciousness is likely to be in place at birth (or shortly after) and may even arise during the third trimester. Progress in this field has been difficult, not just because of the challenges associated with procuring the relevant behavioral and neural data, but also because of uncertainty about how best to study consciousness in the absence of the capacity for verbal report or intentional behavior. This review examines both the empirical and methodological progress in this field, arguing that recent research points in favor of early-onset accounts of the emergence of consciousness.


Subject(s)
Consciousness , Infant, Newborn , Child , Infant , Humans , Uncertainty
7.
J Cardiovasc Electrophysiol ; 34(9): 1802-1807, 2023 09.
Article in English | MEDLINE | ID: mdl-37473404

ABSTRACT

INTRODUCTION: Pulsed-field ablation (PFA) and the multielectrode radiofrequency balloon (RFB) are two novel ablation technologies to perform pulmonary vein isolation (PVI). It is currently unknown whether these technologies differ in lesion formation and lesion extent. We compared the acute lesion extent after PVI induced by PFA and RFB by measuring low-voltage area in high-density maps and the release of biomolecules reflecting cardiac injury. METHODS: PVI was performed with a pentaspline catheter (FARAPULSE) applying PFA or with the compliant multielectrode RFB (HELIOSTAR). Before and after PVI high-density mapping with CARTO 3 was performed. In addition, blood samples were taken before transseptal puncture and after post-PVI remapping and serum concentrations of high-sensitive Troponin I were quantified by immunoassay. RESULTS: Sixty patients undergoing PVI by PFA (n = 28, age 69 ± 12 year, 60% males, 39.3% persistent atrial fibrillation [AF]) or RFB (n = 32, age 65 ± 13 year, 53% males, 21.9% persistent AF) were evaluated. Acute PVI was achieved in all patients in both groups. Mean number of PFA pulses was 34.2 ± 4.5 and mean number RFB applications was 8.5 ± 3 per patient. Total posterior ablation area was significantly larger in PFA (20.7 ± 7.7 cm²) than in RFB (7.1 ± 2.09 cm²; p < .001). Accordingly, posterior ablation area for each PV resulted in larger lesions after PFA versus RFB (LSPV 5.2 ± 2.7 vs. 1.9 ± 0.8 cm², LIPV 5.5 ± 2.3 vs. 1.9 ± 0.8 cm², RSPV 4.7 ± 1.9 vs. 1.6 ± 0.5 cm², RIPV 5.3 ± 2.1 vs. 1.6 ± 0.7 cm,² respectively; p < .001). In a subset of 38 patients, increase of hsTropI was higher after PFA (625 ± 138 pg/mL, n = 28) versus RFB (148 ± 36 pg/mL, n = 10; p = .049) supporting the evidence of larger lesion extent by PFA. CONCLUSION: PFA delivers larger acute lesion areas and higher troponin release upon successful PVI than multielectrode RFB-based PVI in this single-center series.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Male , Humans , Middle Aged , Aged , Aged, 80 and over , Female , Pulmonary Veins/surgery , Treatment Outcome , Catheter Ablation/adverse effects , Catheter Ablation/methods , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheters
8.
Circ J ; 87(7): 950-956, 2023 06 23.
Article in English | MEDLINE | ID: mdl-37286488

ABSTRACT

BACKGROUND: A novel multielectrode radiofrequency balloon (RFB) catheter has been released for pulmonary vein isolation (PVI).Methods and Results: In this observational study consecutive patients with drug-refractory paroxysmal or persistent atrial fibrillation (AF) undergoing first-time PVI were enrolled in 2 high-volume ablation centers. All procedures were conducted in conjunction with a 3D-mapping system. Clinical, procedural and ablation parameters were systematically analyzed. 105 patients (58% male; 52% paroxysmal AF, 68±11.3 years mean age, left atrial volume index 38.6±14.8 mL/m2) were included. 241/412 (58.5%) PVs were successfully isolated with a single shot (SS), with a time-to-isolation of 11.6±8 s. Total number of radiofrequency applications was 892 (mean 2.2/PV), resulting in successful isolation of 408/412 (99%) PVs at the end of the procedure. Mean electrodes' impedance drop was significantly higher in the SS-PVI compared with non-SS applications (21.5±6.6 vs. 18.6±6.5 Ohm). Concordantly, higher temperature rise was observed in the SS vs. non-SS applications (10.9±4.9℃ vs. 9.6±4.7℃). CONCLUSIONS: In this multicenter real-world study, mean impedance drop and temperature rise were associated with successful SS-PVI applying the novel RFB catheter. These parameters may help to guide efficient usage of the new RF balloon.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Male , Female , Treatment Outcome , Catheter Ablation/methods , Atrial Fibrillation/surgery , Heart Atria , Pulmonary Veins/surgery , Catheters , Recurrence
10.
Neuroimage ; 273: 120057, 2023 06.
Article in English | MEDLINE | ID: mdl-37001834

ABSTRACT

When does the mind begin? Infant psychology is mysterious in part because we cannot remember our first months of life, nor can we directly communicate with infants. Even more speculative is the possibility of mental life prior to birth. The question of when consciousness, or subjective experience, begins in human development thus remains incompletely answered, though boundaries can be set using current knowledge from developmental neurobiology and recent investigations of the perinatal brain. Here, we offer our perspective on how the development of a sensory perturbational complexity index (sPCI) based on auditory ("beep-and-zip"), visual ("flash-and-zip"), or even olfactory ("sniff-and-zip") cortical perturbations in place of electromagnetic perturbations ("zap-and-zip") might be used to address this question. First, we discuss recent studies of perinatal cognition and consciousness using techniques such as functional magnetic resonance imaging (fMRI), electroencephalography (EEG), and, in particular, magnetoencephalography (MEG). While newborn infants are the archetypal subjects for studying early human development, researchers may also benefit from fetal studies, as the womb is, in many respects, a more controlled environment than the cradle. The earliest possible timepoint when subjective experience might begin is likely the establishment of thalamocortical connectivity at 26 weeks gestation, as the thalamocortical system is necessary for consciousness according to most theoretical frameworks. To infer at what age and in which behavioral states consciousness might emerge following the initiation of thalamocortical pathways, we advocate for the development of the sPCI and similar techniques, based on EEG, MEG, and fMRI, to estimate the perinatal brain's state of consciousness.


Subject(s)
Brain , Consciousness , Infant , Child , Infant, Newborn , Pregnancy , Female , Humans , Cognition , Magnetoencephalography , Electroencephalography/methods
11.
Macromol Rapid Commun ; 44(16): e2200332, 2023 Aug.
Article in English | MEDLINE | ID: mdl-35689352

ABSTRACT

Bioderived polymers are one of many current research areas that promise a sustainable future. Due to their unique properties, the bioderived polymer polydopamine has been in the spotlight over the last decades. Its ability to adhere to virtually any surface and its stability over a wide pH range as well as in several organic solvents make it a suitable candidate for various applications like coatings and biosensors. However, strong light absorption over a broad range of wavelengths and high quenching efficiency limit its uses. Therefore, new bioderived polymers with similar features to polydopamine but without fluorescence quenching properties are highly desirable. Herein, the electropolymerization of a bioderived analog of dopamine, 3-amino-l-tyrosine, is demonstrated. The resulting polymer, poly(amino-l-tyrosine), exhibits several characteristics complementary to or even exceeding those of polydopamine and its analog, polynorepinephrine, rendering poly(amino-l-tyrosine) attractive for the development of sensors and photoactive devices. Cyclic voltammetry, spectro-electrochemistry, and electrochemical quartz crystal microbalance measurements are applied to study the electrodeposition of this material, and the resulting films are compared to polydopamine and polynorepinephrine. Impedance spectroscopy reveals increased ion permeability of poly(amino-l-tyrosine) compared to polydopamine and polynorepinephrine. Moreover, the reduced fluorescence quenching of poly(amino-l-tyrosine) supports its use as coating for biosensors and organic semiconductors.


Subject(s)
Biosensing Techniques , Polymers , Polymers/chemistry , Tyrosine , Dopamine/chemistry , Quartz Crystal Microbalance Techniques
12.
Clin Res Cardiol ; 112(12): 1727-1737, 2023 Dec.
Article in English | MEDLINE | ID: mdl-35713695

ABSTRACT

BACKGROUND: Despite continued efforts to improve the safety of catheter ablation, pericardial tamponade remains one of its more frequent, potentially life-threatening complications. Management of cardiac tamponade is not standardized and uncertainties regarding acute treatment remain. METHODS: This survey sought to evaluate the management of cardiac tamponade in German EP centers via a standardized postal questionnaire. All 341 identified German EP centers were invited to return a questionnaire on their standards for the management of cardiac tamponade. RESULTS: A total of 189 German EP centers completed the questionnaire. Several precautions are followed to avoid pericardial tamponade: A minority of centers preclude very old patients (19%) or those with a high body mass index (30%) from ablation. Non-vitamin K antagonist oral anticoagulants are briefly paused in most centers (88%) before procedures, while vitamin K antagonists are continued. Pericardial tamponade is usually treated using reversal of heparin by applying protamine (86%) and pericardiocentesis under both, fluoroscopic and echocardiographic guidance (62%). A pigtail catheter is mostly inserted (97%) and autotransfusion of aspirated blood is performed in 47% of centers. The decision for surgical repair depends on different clinical and infrastructural aspects. The timing of reinitiation of anticoagulation widely differs between the centers. Approximately 1/3 of centers prescribe nonsteroidal anti-inflammatory agents, colchicine or steroids after pericardiocentesis. CONCLUSION: The present survey shows that the management of cardiac tamponade is still inhomogeneous in German ablation centers. However, multiple findings of this survey can be generalized and might guide especially less experienced operators and centers in their treatment and decision strategies.


Subject(s)
Cardiac Tamponade , Humans , Cardiac Tamponade/diagnosis , Cardiac Tamponade/etiology , Cardiac Tamponade/therapy , Pericardiocentesis/adverse effects , Pericardiocentesis/methods , Anticoagulants/therapeutic use , Heparin , Cardiac Electrophysiology
13.
Clin Res Cardiol ; 112(6): 795-806, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36131138

ABSTRACT

PURPOSE: Pulsed-field ablation (PFA) is a new energy source to achieve pulmonary vein isolation (PVI) by targeted electroporation of cardiomyocytes. Experimental and controlled clinical trial data suggest good efficacy of PFA-based PVI. We aimed to assess efficacy, safety and follow-up of PFA-based PVI in an early adopter routine care setting. METHODS: Consecutive patients with symptomatic paroxysmal or persistent atrial fibrillation (AF) underwent PVI using the Farawave® PFA ablation catheter in conjunction with three-dimensional mapping at two German high-volume ablation centers. PVI was achieved by applying 8 PFA applications in each PV. RESULTS: A total of 138 patients undergoing a first PVI (67 ± 12 years, 66% male, 62% persistent AF) were treated. PVI was achieved in all patients by deploying 4563 applications in 546 PVs (8.4 ± 1.0/PV). Disappearance of PV signals after the first application was demonstrated in 544/546 PVs (99.6%). More than eight PFA applications were performed in 29/546 PVs (6%) following adapted catheter positioning or due to reconnection as assessed during remapping. Mean procedure time was 78 ± 22 min including pre- and post PVI high-density voltage mapping. PFA catheter LA dwell-time was 23 ± 9 min. Total fluoroscopy time and dose area product were 16 ± 7 min and 505 [275;747] cGy*cm2. One pericardial tamponade (0.7%), one transient ST-elevation (0.7%) and three groin complications (2.2%) occurred. 1-year follow-up showed freedom of arrhythmia in 90% in patients with paroxysmal AF (n = 47) and 60% in patients with persistent AF (n = 82, p = 0.015). CONCLUSIONS: PFA-based PVI is acutely highly effective and associated with a beneficial safety and low recurrence rate.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Male , Female , Follow-Up Studies , Pulmonary Veins/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Fluoroscopy , Treatment Outcome , Recurrence
15.
Front Cardiovasc Med ; 9: 1046956, 2022.
Article in English | MEDLINE | ID: mdl-36505349

ABSTRACT

Background: The novel DiamondTemp™ (DT)-catheter (Medtronic®) was designed for high-power, short-duration ablation in a temperature-controlled mode. Aim: To evaluate the performance of the DT-catheter for ablation of the mitral isthmus line (MIL) using two different energy dosing strategies. Materials and methods: Twenty patients with recurrence of atrial fibrillation (AF) and/or atrial tachycardia (AT) following pulmonary vein (PV) isolation were included. All patients underwent reisolation of PVs in case of electrical reconnection and ablation of a MIL using the DT-catheter. Application durations of 10 (group A, n = 10) or 20 s (group B, n = 10) were applied. If bidirectional block was not reached with endocardial ablation, additional ablation from within the coronary sinus (CS) was conducted. Results: In 19/20 (95%) patients, DT ablation of the MIL resulted in bidirectional block. Mean procedure and fluoroscopy time, and dose area product did not differ significantly between the two groups. In group B, fewer radiofrequency applications were needed to achieve bidirectional block of the MIL when compared to group A (26 ± 12 vs. 42 ± 17, p = 0.04). Ablation from within the CS was performed in 8/10 patients (80%) of group A and in 5/10 (50%) patients of group B (p = 0.34). No major complication occurred. Conclusion: Mitral isthmus line ablation with use of the DT-catheter is highly effective and safe. Longer radiofrequency-applications appear to be favorable without compromising safety.

16.
Geburtshilfe Frauenheilkd ; 82(11): 1265-1273, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36339634

ABSTRACT

Introduction During the COVID-19 pandemic, stress and anxiety in the population increased due to concerns about people's own health and that of their relatives, as well as changes in everyday life due to measures taken to reduce the infection rate. Pregnant women are particularly stressed. The present study examines how the COVID-19 pandemic affects the stress experience and mental health of pregnant women and mothers of newborns and how care could be optimized. Methods As part of the international COVGEN initiative ( https://www.covgen.org ) to investigate the effects of the COVID-19 pandemic on the peripartum period, pregnant and postpartum women were asked about their experience with stress using the COPE-IS (Coronavirus Perinatal Experiences - Impact Survey) questionnaire developed for this purpose and translated from the English. In addition, demographic data, pre-existing diseases, pregnancy complications and the care situation were recorded. The questionnaire was either administered as hardcopy to inpatients at the Department of Women's Health, University Hospital Tübingen, Germany, or online. All pregnant women and mothers who were pregnant or had given birth after the official start of the COVID-19 pandemic (11 March 2020) were eligible to participate. Results Complete data sets of n = 156 pregnant women and n = 221 postpartum women were available for evaluation. The general stress level assessed with the COPE-IS was significantly increased by the COVID-19 pandemic in both, pregnant and postpartum women, with pre-existing conditions such as respiratory diseases and pregnancy-related diseases like gestational diabetes adding to the stress. The subjectively perceived quality of care/support during pregnancy also influenced the stress level. Conclusions Fears of a COVID-19 infection and changes in preventive and aftercare services were a burden for the women surveyed. Intensified care during pregnancy and puerperium could help to stabilize the mental situation and reduce stress.

17.
Int Heart J ; 63(3): 504-509, 2022.
Article in English | MEDLINE | ID: mdl-35650152

ABSTRACT

Pulmonary vein (PV) isolation (PVI) by continuous, transmural and durable lesions is decisive for ensuring long-term freedom from atrial fibrillation (AF). AF ablation requires irrigated tip catheters to reduce thromboembolic complications. This precluded temperature-controlled delivery of radiofrequency (RF) energy.The aim of this study was to evaluate feasibility, acute efficacy, and safety of an irrigated, temperature-controlled ablation catheter [DiamondTemp™ (DT) Medtronic®] for PVI.Consecutive patients with AF underwent PVI using the DT catheter combined with high-power short-duration RF applications. Ablation settings were (1) a catheter tip temperature limit of 60°C, (2) a temperature-controlled power of 50 W, and (3) application duration of 10 seconds. The primary endpoint was acute isolation of PVs, reassessed after a 30-minute waiting period. Secondary endpoints included procedural parameters (defined as a catheter tip temperature of 50°C > 3 seconds, an impedance drop of 5-10 Ω) and the occurrence of serious adverse events.Fifty consecutive patients [mean age 66 ± 12 years, 38 (76%) women, 24 patients with paroxysmal AF (48%)] were included. Median procedure and left atrial dwell time was 89 [68; 107] and 63 [52; 79] minutes, respectively. Mean number of RF applications was 59 ± 20, and mean total RF duration was 14 ± 6 minutes. Acute PVI was achieved in all patients solely using DT ablation. Acute PV reconnection within the waiting period occurred in five patients; all reconnected PVs were successfully reisolated. One major complication occurred.In this study, the DT ablation system demonstrated high acute efficacy for PVI. Temperature-controlled ablation in conjunction with high-power short-duration applications might be effectively supported.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Aged , Atrial Fibrillation/surgery , Catheter Ablation/methods , Equipment Design , Female , Humans , Male , Middle Aged , Pulmonary Veins/surgery , Treatment Outcome
18.
Sci Rep ; 12(1): 9139, 2022 06 01.
Article in English | MEDLINE | ID: mdl-35650230

ABSTRACT

Ultra-high-density (UHD) mapping can improve scar area detection and fast activation mapping in patients undergoing catheter ablation of ventricular tachycardia (VT). The aim of the present study was to compare the outcome after VT ablation guided by UHD and conventional point-by-point 3D-mapping. The acute and long-term ablation outcome of 61 consecutive patients with UHD mapping (64-electrode mini-basket catheter) was compared to 61 consecutive patients with conventional point-by-point 3D-mapping using a 3.5 mm tip catheter. Patients, whose ablation was guided by UHD mapping had an improved 24-months outcome in comparison to patients with conventional mapping (cumulative incidence estimate of the combination of recurrence or disease-related death of 52.4% (95% confidence interval (CI) [36.9-65.7]; recurrence: n = 25; disease-related death: n = 4) versus 69.6% (95% CI [55.9-79.8]); recurrence: n = 31; disease-related death n = 11). In a cause-specific Cox proportional hazards model, UHD mapping (hazard ratio (HR) 0.623; 95% CI [0.390-0.995]; P = 0.048) and left ventricular ejection fraction > 30% (HR 0.485; 95% CI [0.290-0.813]; P = 0.006) were independently associated with lower rates of recurrence or disease-related death. Other procedural parameters were similar in both groups. In conclusion, UHD mapping during VT ablation was associated with fewer VT recurrences or disease-related deaths during long-term follow-up in comparison to conventional point-by-point mapping. Complication rates and other procedural parameters were similar in both groups.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Body Surface Potential Mapping , Catheter Ablation/adverse effects , Humans , Stroke Volume , Treatment Outcome , Ventricular Function, Left
19.
Front Cardiovasc Med ; 9: 910042, 2022.
Article in English | MEDLINE | ID: mdl-35694678

ABSTRACT

Introduction: Catheter ablation of ventricular arrhythmias emerging from the ventricular outflow tracts and adjacent structures is very effective and considered almost curative in patients without structural heart disease (SHD). Outcomes of patients with SHD undergoing ablation of outflow tract arrhythmias are not known. Methods: Consecutive patients (2019-2021) undergoing catheter ablation of ventricular arrhythmias in a single high-volume center were retrospectively analyzed. Patients with ablation of outflow tract arrhythmias were identified and divided in individuals with and without SHD. Procedural parameters and acute outcome were compared. Results: We identified 215 patients with outflow tract arrhythmias (35.3% female, mean age 58.3 ± 16.0 years). Of those, 93 (43.3%) had SHD. Patients with SHD and outflow tract arrhythmias were older (65.0 ± 12.8 vs. 53.3 ± 16.3 years; p < 0.001), more often male (82.8 vs. 50.0%; p < 0.001) and had more comorbidities than patients without SHD (arterial hypertension: 62.4 vs. 34.4%, p < 0.001; diabetes: 22.6 vs. 8.2%, p = 0.005; chronic lung disease: 20.4 vs. 7.4%, p = 0.007). Outflow tract arrhythmias in patients with SHD had their origin more often in the left ventricle (68.8 vs. 53.3%, p = 0.025). The acute success rate was similar in both patient groups (93.4 vs. 94.2%, p = 0.781). Patients with SHD were discharged later {median length of hospital stay with SHD 5 [6 (interquartile range)] days, without SHD 2 [4] days, p < 0.001}. Periprocedural complications were numerically more frequent in patients with SHD [with SHD 12 (12.9%), without SHD 8 (6.6%), p = 0.154]. Conclusion: Outflow tract arrhythmia ablation has a high success rate irrespective of the presence of SHD. Longer hospital stay and potentially a higher risk of periprocedural complications should be considered when discussing this treatment option with patients.

20.
Zootaxa ; 5105(1): 105-130, 2022 Mar 02.
Article in English | MEDLINE | ID: mdl-35391312

ABSTRACT

The outer shelf and upper slope region under the influence of the Amazon River mouth harbors an extensive reef system with a rich sponge fauna, but no hexactinellids were recorded in the area so far. In this work, manned submersibles were used to describe for the first time three species of Hexactinellida off the Amazon River mouth: Hyalonema (Cyliconemaoida) alucia sp. nov., Dactylocalyx pumiceus and Claviscopulia facunda. We found two morphotypes of Dactylocalyx pumiceus, suggesting that it may be a complex of cryptic species. The populations of the three species off Par State were sparse, but a large aggregation of D. pumiceus was found off Maranho State from 145 to 230 m depth. These findings indicate that hexactinellid grounds may be more common along the Northern Brazilian continental outer shelf and slope than previously thought.


Subject(s)
Porifera , Rivers , Animals , Brazil
SELECTION OF CITATIONS
SEARCH DETAIL
...