Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Am Coll Health ; : 1-9, 2023 Jan 03.
Article in English | MEDLINE | ID: mdl-36595575

ABSTRACT

OBJECTIVE: A small percentage of universities and colleges conducted mass SARS-CoV-2 testing. However, universal testing is resource-intensive, strains national testing capacity, and false negative tests can encourage unsafe behaviors. PARTICIPANTS: A large urban university campus. METHODS: Virus control centered on three pillars: mitigation, containment, and communication, with testing of symptomatic and a random subset of asymptomatic students. RESULTS: Random surveillance testing demonstrated a prevalence among asymptomatic students of 0.4% throughout the term. There were two surges in cases that were contained by enhanced mitigation and communication combined with targeted testing. Cumulative cases totaled 445 for the term, most resulting from unsafe undergraduate student behavior and among students living off-campus. A case rate of 232/10,000 undergraduates equaled or surpassed several peer institutions that conducted mass testing. CONCLUSIONS: An emphasis on behavioral mitigation and communication can control virus transmission on a large urban campus combined with a limited and targeted testing strategy.

2.
J Clin Virol ; 48(4): 234-8, 2010 Aug.
Article in English | MEDLINE | ID: mdl-20580600

ABSTRACT

BACKGROUND: In April 2009, the United States Secretary of the Department of Health and Human Services declared a public health emergency concerning the 2009 influenza H1N1 outbreak. This declaration allowed the FDA to issue Emergency Use Authorization (EUA) of approved in vitro diagnostics to detect the 2009 influenza H1N1 in clinical specimens. OBJECTIVES: This report outlines the validation testing of the Cepheid Xpert Flu A Panel for the qualitative detection of 2009 H1N1 viral RNA. STUDY DESIGN: This study was a multi-site, dual-method clinical evaluation comparing the results of testing between the Xpert Panel assay to the FDA-cleared Luminex Molecular Diagnostics xTAG Respiratory Viral Panel (Luminex RVP) assay and the EUA-granted Focus Diagnostics Influenza A/H1N1 (2009) Real Time RT-PCR (Focus H1N1) assay. RESULTS: When compared to Luminex RVP (n=300) for influenza A detection, the Xpert Panel had a sensitivity of 91.2% (95% CI: 85.1-95.4), specificity of 99.4% (95% CI: 96.7-100), positive predictive value (PPV) of 99.2% (95% CI: 95.6-100), and a negative predictive value (NPV) of 93.1% (95% CI: 88.3-96.4). When compared to the Focus H1N1 (n=258) for detection of H1N1, the Xpert Panel had a sensitivity of 92.1% (95% CI: 82.4-97.4), specificity of 100% (95% CI: 98.5-100), PPV of 100% (95% CI: 95.0-100), and a NPV of 97.5% (95% CI: 94.3-99.2). CONCLUSIONS: The results show the Cepheid Xpert Flu A Panel to be comparable to both the Luminex RVP and the Focus H1N1 assays. The Cepheid Xpert Panel was granted an EUA on 24 Dec 2009.


Subject(s)
Influenza A Virus, H1N1 Subtype/isolation & purification , Influenza, Human/diagnosis , Influenza, Human/virology , RNA, Viral/isolation & purification , Reverse Transcriptase Polymerase Chain Reaction/methods , Virology/methods , Humans , Predictive Value of Tests , RNA, Viral/genetics , Reagent Kits, Diagnostic , Sensitivity and Specificity , United States
SELECTION OF CITATIONS
SEARCH DETAIL
...