Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
AJNR Am J Neuroradiol ; 42(7): 1270-1275, 2021 07.
Article in English | MEDLINE | ID: mdl-33766821

ABSTRACT

BACKGROUND AND PURPOSE: Spinal arteriovenous fistulas are challenging to cure by endovascular means, with a risk of incomplete occlusion or delayed recurrence. The authors report herein their preliminary experience using the pressure cooker technique for the embolization of spinal arteriovenous fistulas. MATERIALS AND METHODS: Fifteen patients (8 men; mean age, 60.3 years) underwent an endovascular treatment of a spinal arteriovenous fistula (12 dural spinal arteriovenous fistulas and 3 epidural spinal arteriovenous fistulas) in 2 different institutions using the pressure cooker technique. Two microcatheters could be navigated in the segmental artery in all patients using 2 guiding catheters. A proximal plug was achieved with highly concentrated cyanoacrylate ± coils. The liquid embolic agent injected to cure the fistula was diluted cyanoacrylate (n = 11) or ethylene-vinyl alcohol (n = 4). Technical and clinical complications were systematically recorded. Clinical and angiographic outcomes were systematically evaluated at follow-up. RESULTS: One (6.7%) procedure-related complication was recorded, which consisted of a transient radicular deficit, related to nerve root ischemia. Clinical improvement was observed in 10/14 (71%) patients for whom clinical follow-up was available. Complete spinal arteriovenous fistula occlusion on a follow-up angiography was observed in 11/12 patients (91.7%) for whom angiographic follow-up was available. One patient (8.3%) presented with a delayed recurrence at 29 months. CONCLUSIONS: The pressure cooker technique is feasible, with either glue or ethylene-vinyl alcohol, for the embolization of spinal arteriovenous fistulas. Our results suggest the safety and effectiveness of this technique.


Subject(s)
Arteriovenous Fistula , Endovascular Procedures , Arteriovenous Fistula/diagnostic imaging , Arteriovenous Fistula/therapy , Central Nervous System Vascular Malformations/diagnostic imaging , Central Nervous System Vascular Malformations/therapy , Embolization, Therapeutic , Female , Humans , Male , Middle Aged , Polyvinyls , Pressure , Retrospective Studies , Treatment Outcome
2.
AJNR Am J Neuroradiol ; 41(7): 1309-1315, 2020 07.
Article in English | MEDLINE | ID: mdl-32554417

ABSTRACT

BACKGROUND AND PURPOSE: Spine MR imaging plays a pivotal role in the diagnostic work-up of spontaneous intracranial hypotension. The aim of this study was to compare the diagnostic accuracy of unenhanced spine MR imaging and intrathecal gadolinium-enhanced spine MR imaging for identification and localization of CSF leaks in patients with spontaneous intracranial hypotension. MATERIALS AND METHODS: A retrospective study of patients with spontaneous intracranial hypotension examined from February 2013 to October 2017 was conducted. Their spine MR imaging was reviewed by 3 blinded readers for the presence of epidural CSF using 3 different sequences (T2WI, 3D T2WI fat-saturated, T1WI gadolinium). In patients with leaks, the presumed level of the leak was reported. RESULTS: In total, 103 patients with spontaneous intracranial hypotension (63/103 [61%] women; mean age, 50 years) were evaluated. Seventy had a confirmed CSF leak (57/70 [81%] proved intraoperatively), and 33 showed no epidural CSF on multimodal imaging. Intrathecal gadolinium-enhanced spine MR imaging was nonsuperior to unenhanced spine MR imaging for the detection of epidural CSF (P = .24 and .97). All MR imaging sequences had a low accuracy for leak localization. In all patients, only 1 leakage point was present, albeit multiple suspicious lesions were reported in all sequences (mean, 5.0). CONCLUSIONS: Intrathecal gadolinium-enhanced spine MR imaging does not improve the diagnostic accuracy for the detection of epidural CSF. Thus, it lacks a rationale to be included in the routine spontaneous intracranial hypotension work-up. Heavily T2-weighted images with fat saturation provide high accuracy for the detection of an epidural CSF collection. Low accuracy for leak localization is due to an extensive CSF collection spanning several vertebrae (false localizing sign), lack of temporal resolution, and a multiplicity of suspicious lesions, albeit only a single leakage site is present. Thus, dynamic examination is mandatory before targeted treatment is initiated.


Subject(s)
Cerebrospinal Fluid Leak/diagnostic imaging , Intracranial Hypotension/diagnostic imaging , Magnetic Resonance Imaging/methods , Spinal Cord/diagnostic imaging , Adult , Aged , Aged, 80 and over , Cerebrospinal Fluid Leak/complications , Female , Gadolinium DTPA , Humans , Image Enhancement/methods , Intracranial Hypotension/etiology , Male , Middle Aged , Myelography/methods , Retrospective Studies
3.
AJNR Am J Neuroradiol ; 39(10): 1848-1853, 2018 10.
Article in English | MEDLINE | ID: mdl-30166434

ABSTRACT

BACKGROUND AND PURPOSE: In 5%-10% of patients with acute ischemic stroke with an intention to treat with mechanical thrombectomy, no reperfusion can be achieved (Thrombolysis in Cerebral Infarction score = 0/1). Purpose of this analysis was a systematic assessment of underlying reasons for reperfusion failures. MATERIALS AND METHODS: An intention-to-treat single-center cohort (n = 592) was re-evaluated for all patients in whom no reperfusion could be achieved (n = 63). Baseline characteristics of patients were compared between patients with and without reperfusion failures. After qualitative review of all cases with reperfusion failures, a classification system was proposed and relative frequencies were reported. In a second step, occurrence of delayed recanalization at 24 hours after reperfusion failure and dependency on IV-tPA were evaluated. RESULTS: In 63/592 patients with an intention to perform stent-retriever thrombectomy, no reperfusion was achieved (TICI 0/1, 10.6%, 95% CI, 8.2%-13.1%). Older patients (adjusted OR per yr = 1.03; 95% CI, 1.01-1.05) and patients with M2 occlusion (adjusted OR = 3.36; 95% CI, 1.82-6.21) were at higher risk for reperfusion failure. In most cases, no reperfusion was a consequence of technical difficulties (56/63, 88.9%). In one-third of these cases, reperfusion failures were due to the inability to reach the target occlusion (20/63, 31.7%), while "stent-retriever failure" occurred in 39.7% (25/63) of patients. Delayed recanalization was very rare (18.2%), without dependence on IV-tPA pretreatment status. CONCLUSIONS: Reasons for reperfusion failure in stent-retriever thrombectomy are heterogeneous. The failure to establish intracranial or cervical access is almost as common as stent-retriever failure after establishing intracranial access. Systematic reporting standards of reasons may help to further estimate relative frequencies and thereby guide priorities for technical development and scientific effort.


Subject(s)
Stroke/surgery , Thrombectomy/methods , Treatment Failure , Aged , Cohort Studies , Female , Humans , Male , Middle Aged , Registries , Reperfusion , Stents , Thrombectomy/instrumentation
4.
AJNR Am J Neuroradiol ; 38(10): 1984-1989, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28818827

ABSTRACT

BACKGROUND AND PURPOSE: Combined transarterial balloon-assisted endovascular embolization with double-lumen balloon microcatheters and concomitant transvenous balloon protection was described as a promising treatment technique for dural arteriovenous fistulae of the transverse and sigmoid sinus. The purpose of this study was to evaluate the technical efficacy and safety of this combined treatment technique. MATERIALS AND METHODS: Nine consecutive patients presenting with dural arteriovenous fistulas of the transverse and sigmoid sinuses underwent combined transarterial and transvenous balloon-assisted endovascular embolization. Prospectively collected data were reviewed to assess the technical success rate, complication rate, and clinical outcome. RESULTS: Six patients presented with clinically symptomatic Borden type I, and 3 patients, with Borden type II dural arteriovenous fistulas of the transverse and sigmoid sinuses (3 men, 6 women; mean age, 50.4 years). Transarterial embolization was performed with a double-lumen balloon with Onyx and concomitant transvenous sinus protection with a dedicated venous remodeling balloon. Complete angiographic occlusion at the latest follow-up (mean, 4.8 months) was achieved in 6 patients, and near-complete occlusion, in 2 patients. Clinical cure or remission of symptoms was obtained in 6 and 2 patients, respectively. One patient with a residual fistula underwent further treatment in which the dural arteriovenous fistula was cured by sinus occlusion. Complete occlusion of the dural arteriovenous fistula was visible on the follow-up angiography after final treatment in 8 patients. One patient refused follow-up angiography but was free of symptoms. There were no immediate or delayed postinterventional complications. CONCLUSIONS: Transarterial balloon-assisted embolization of dural arteriovenous fistulas of the transverse and sigmoid sinuses with combined transvenous balloon protection is safe and offers a high rate of complete dural arteriovenous fistula occlusion and remission of clinical symptoms.


Subject(s)
Balloon Occlusion/methods , Central Nervous System Vascular Malformations/diagnostic imaging , Central Nervous System Vascular Malformations/surgery , Cranial Sinuses/diagnostic imaging , Cranial Sinuses/surgery , Embolization, Therapeutic/methods , Endovascular Procedures/methods , Adult , Aged , Balloon Occlusion/adverse effects , Cerebral Angiography , Combined Modality Therapy , Drug Combinations , Embolization, Therapeutic/adverse effects , Female , Follow-Up Studies , Humans , Male , Middle Aged , Polyvinyls , Prospective Studies , Tantalum , Treatment Outcome , Young Adult
5.
AJNR Am J Neuroradiol ; 38(5): 868-874, 2017 May.
Article in English | MEDLINE | ID: mdl-28302611

ABSTRACT

BACKGROUND AND PURPOSE: CTA can rapidly and accurately detect and localize occlusive disease in patients with ischemic stroke. We have used CTA to assess arterial stenosis and occlusion in an ischemic stroke population arriving at a tertiary stroke center within 24 hours of symptom onset in order to obtain a comprehensive picture of occlusive disease pattern, and to determine the proportion of eligible candidates for endovascular treatment. MATERIALS AND METHODS: Data from consecutive patients with acute ischemic stroke admitted to a single center between 2003 and 2012, collected in the Acute Stroke Registry and Analysis of Lausanne data base, were retrospectively analyzed. Patients with a diagnostic CTA within 24 hours of symptom onset were selected. Relevant extra- and intracranial pathology, defined as stenosis of ≥50% and occlusions, were registered and classified into 21 prespecified segments. RESULTS: Of the 2209 included patients (42.1% women; median age, 72 years), 1075 (48.7%) had pathology in and 308 (13.9%) had pathology outside the ischemic territory. In the 50,807 arterial segments available for revision, 1851 (3.6%) abnormal segments were in the ischemic (symptomatic) territory and another 408 (0.8%) were outside it (asymptomatic). In the 1211 patients with ischemic stroke imaged within 6 hours of symptom onset, 40.7% had symptomatic large, proximal occlusions potentially amenable to endovascular therapy. CONCLUSIONS: CTA in patients with acute ischemic stroke shows large individual variations of occlusion sites and degrees. Approximately half of such patients have no visible occlusive disease, and 40% imaged within 6 hours show large, proximal segment occlusions amenable to endovascular therapy. These findings show the importance of early noninvasive imaging of extra- and intracranial arteries for identifying occlusive disease, planning recanalization strategies, and designing interventional trials.


Subject(s)
Brain Ischemia/diagnostic imaging , Computed Tomography Angiography/methods , Stroke/diagnostic imaging , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged
7.
AJNR Am J Neuroradiol ; 34(10): 1996-9, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23764724

ABSTRACT

SUMMARY: Coil displacement during endovascular coiling procedures may require coil retrieval in the context of flow limitation or thromboembolic risk. No standard recommended method of coil retrieval exists. We present a consecutive series of 14 patients with displaced coil during aneurysm coiling in whom the complication was effectively managed with the use of a stent retriever system. Two illustrative cases from the 14 are described, and technical notes are detailed regarding use of the technique. The use of stent retrievers presents a simple, safe, and effective choice for removal of prolapsed coils during aneurysm coiling.


Subject(s)
Aneurysm, Ruptured/therapy , Device Removal/instrumentation , Embolization, Therapeutic/adverse effects , Foreign-Body Migration/etiology , Intracranial Aneurysm/therapy , Stents/adverse effects , Adult , Aged , Databases, Factual , Device Removal/methods , Embolization, Therapeutic/instrumentation , Female , Humans , Male , Middle Aged , Treatment Outcome
8.
Int J Legal Med ; 127(3): 639-52, 2013 May.
Article in English | MEDLINE | ID: mdl-23515679

ABSTRACT

BACKGROUND AND PURPOSE: Multi-phase postmortem CT angiography (MPMCTA) is increasingly being recognized as a valuable adjunct medicolegal tool to explore the vascular system. Adequate interpretation, however, requires knowledge about the most common technique-related artefacts. The purpose of this study was to identify and index the possible artefacts related to MPMCTA. MATERIAL AND METHODS: An experienced radiologist blinded to all clinical and forensic data retrospectively reviewed 49 MPMCTAs. Each angiographic phase, i.e. arterial, venous and dynamic, was analysed separately to identify phase-specific artefacts based on location and aspect. RESULTS: Incomplete contrast filling of the cerebral venous system was the most commonly encountered artefact, followed by contrast agent layering in the lumen of the thoracic aorta. Enhancement or so-called oedematization of the digestive system mucosa was also frequently observed. CONCLUSION: All MPMCTA artefacts observed and described here are reproducible and easily identifiable. Knowledge about these artefacts is important to avoid misinterpreting them as pathological findings.


Subject(s)
Angiography/methods , Artifacts , Autopsy/methods , Tomography, X-Ray Computed/methods , Adolescent , Adult , Aged , Aged, 80 and over , Cardiovascular System/diagnostic imaging , Cardiovascular System/pathology , Cause of Death , Digestive System/blood supply , Digestive System/diagnostic imaging , Digestive System/pathology , Female , Humans , Male , Middle Aged , Retrospective Studies , Single-Blind Method
SELECTION OF CITATIONS
SEARCH DETAIL
...