Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 183
Filter
1.
World J Gastroenterol ; 30(19): 2523-2537, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38817655

ABSTRACT

BACKGROUND: Autoimmune enteropathy (AIE) is a rare disease whose diagnosis and long-term prognosis remain challenging, especially for adult AIE patients. AIM: To improve overall understanding of this disease's diagnosis and prognosis. METHODS: We retrospectively analyzed the clinical, endoscopic and histopathological characteristics and prognoses of 16 adult AIE patients in our tertiary medical center between 2011 and 2023, whose diagnosis was based on the 2007 diagnostic criteria. RESULTS: Diarrhea in AIE patients was characterized by secretory diarrhea. The common endoscopic manifestations were edema, villous blunting and mucosal hyperemia in the duodenum and ileum. Villous blunting (100%), deep crypt lymphocytic infiltration (67%), apoptotic bodies (50%), and mild intraepithelial lymphocytosis (69%) were observed in the duodenal biopsies. Moreover, there were other remarkable abnormalities, including reduced or absent goblet cells (duodenum 94%, ileum 62%), reduced or absent Paneth cells (duodenum 94%, ileum 69%) and neutrophil infiltration (duodenum 100%, ileum 69%). Our patients also fulfilled the 2018 diagnostic criteria but did not match the 2022 diagnostic criteria due to undetectable anti-enterocyte antibodies. All patients received glucocorticoid therapy as the initial medication, of which 14/16 patients achieved a clinical response in 5 (IQR: 3-20) days. Immunosuppressants were administered to 9 patients with indications of steroid dependence (6/9), steroid refractory status (2/9), or intensified maintenance medication (1/9). During the median of 20.5 months of follow-up, 2 patients died from multiple organ failure, and 1 was diagnosed with non-Hodgkin's lymphoma. The cumulative relapse-free survival rates were 62.5%, 55.6% and 37.0% at 6 months, 12 months and 48 months, respectively. CONCLUSION: Certain histopathological findings, including a decrease or disappearance of goblet and Paneth cells in intestinal biopsies, might be potential diagnostic criteria for adult AIE. The long-term prognosis is still unsatisfactory despite corticosteroid and immunosuppressant medications, which highlights the need for early diagnosis and novel medications.


Subject(s)
Glucocorticoids , Humans , Female , Male , Retrospective Studies , Adult , Middle Aged , Prognosis , Biopsy , Glucocorticoids/therapeutic use , Polyendocrinopathies, Autoimmune/diagnosis , Polyendocrinopathies, Autoimmune/immunology , Polyendocrinopathies, Autoimmune/pathology , Polyendocrinopathies, Autoimmune/drug therapy , Polyendocrinopathies, Autoimmune/therapy , Ileum/pathology , Ileum/immunology , Duodenum/pathology , Duodenum/immunology , Diarrhea/etiology , Diarrhea/diagnosis , Diarrhea/immunology , Intestinal Mucosa/pathology , Intestinal Mucosa/immunology , Immunosuppressive Agents/therapeutic use , Aged , Young Adult , Endoscopy, Gastrointestinal
2.
Med Phys ; 51(6): 3932-3949, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38710210

ABSTRACT

BACKGROUND: In radiation therapy (RT), accelerated partial breast irradiation (APBI) has emerged as an increasingly preferred treatment modality over conventional whole breast irradiation due to its targeted dose delivery and shorter course of treatment. APBI can be delivered through various modalities including Cobalt-60-based systems and linear accelerators with C-arm, O-ring, or robotic arm design. Each modality possesses distinct features, such as beam energy or the degrees of freedom in treatment planning, which influence their respective dose distributions. These modality-specific considerations emphasize the need for a quantitative approach in determining the optimal dose delivery modality on a patient-specific basis. However, manually generating treatment plans for each modality across every patient is time-consuming and clinically impractical. PURPOSE: We aim to develop an efficient and personalized approach for determining the optimal RT modality for APBI by training predictive models using two different deep learning-based convolutional neural networks. The baseline network performs a single-task (ST), predicting dose for a single modality. Our proposed multi-task (MT) network, which is capable of leveraging shared information among different tasks, can concurrently predict dose distributions for various RT modalities. Utilizing patient-specific input data, such as a patient's computed tomography (CT) scan and treatment protocol dosimetric goals, the MT model predicts patient-specific dose distributions across all trained modalities. These dose distributions provide patients and clinicians quantitative insights, facilitating informed and personalized modality comparison prior to treatment planning. METHODS: The dataset, comprising 28 APBI patients and their 92 treatment plans, was partitioned into training, validation, and test subsets. Eight patients were dedicated to the test subset, leaving 68 treatment plans across 20 patients to divide between the training and validation subsets. ST models were trained for each modality, and one MT model was trained to predict doses for all modalities simultaneously. Model performance was evaluated across the test dataset in terms of Mean Absolute Percent Error (MAPE). We conducted statistical analysis of model performance using the two-tailed Wilcoxon signed-rank test. RESULTS: Training times for five ST models ranged from 255 to 430 min per modality, totaling 1925 min, while the MT model required 2384 min. MT model prediction required an average of 1.82 s per patient, compared to ST model predictions at 0.93 s per modality. The MT model yielded MAPE of 1.1033 ± 0.3627% as opposed to the collective MAPE of 1.2386 ± 0.3872% from ST models, and the differences were statistically significant (p = 0.0003, 95% confidence interval = [-0.0865, -0.0712]). CONCLUSION: Our study highlights the potential benefits of a MT learning framework in predicting RT dose distributions across various modalities without notable compromises. This MT architecture approach offers several advantages, such as flexibility, scalability, and streamlined model management, making it an appealing solution for clinical deployment. With such a MT model, patients can make more informed treatment decisions, physicians gain more quantitative insight for pre-treatment decision-making, and clinics can better optimize resource allocation. With our proposed goal array and MT framework, we aim to expand this work to a site-agnostic dose prediction model, enhancing its generalizability and applicability.


Subject(s)
Deep Learning , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Humans , Radiotherapy Planning, Computer-Assisted/methods , Radiation Dosage , Breast Neoplasms/radiotherapy , Breast Neoplasms/diagnostic imaging
3.
World J Hepatol ; 16(4): 625-639, 2024 Apr 27.
Article in English | MEDLINE | ID: mdl-38689750

ABSTRACT

BACKGROUND: Liver cirrhosis patients admitted to intensive care unit (ICU) have a high mortality rate. AIM: To establish and validate a nomogram for predicting in-hospital mortality of ICU patients with liver cirrhosis. METHODS: We extracted demographic, etiological, vital sign, laboratory test, comorbidity, complication, treatment, and severity score data of liver cirrhosis patients from the Medical Information Mart for Intensive Care IV (MIMIC-IV) and electronic ICU (eICU) collaborative research database (eICU-CRD). Predictor selection and model building were based on the MIMIC-IV dataset. The variables selected through least absolute shrinkage and selection operator analysis were further screened through multivariate regression analysis to obtain final predictors. The final predictors were included in the multivariate logistic regression model, which was used to construct a nomogram. Finally, we conducted external validation using the eICU-CRD. The area under the receiver operating characteristic curve (AUC), decision curve, and calibration curve were used to assess the efficacy of the models. RESULTS: Risk factors, including the mean respiratory rate, mean systolic blood pressure, mean heart rate, white blood cells, international normalized ratio, total bilirubin, age, invasive ventilation, vasopressor use, maximum stage of acute kidney injury, and sequential organ failure assessment score, were included in the multivariate logistic regression. The model achieved AUCs of 0.864 and 0.808 in the MIMIC-IV and eICU-CRD databases, respectively. The calibration curve also confirmed the predictive ability of the model, while the decision curve confirmed its clinical value. CONCLUSION: The nomogram has high accuracy in predicting in-hospital mortality. Improving the included predictors may help improve the prognosis of patients.

4.
Adv Radiat Oncol ; 9(6): 101476, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38690296

ABSTRACT

This article focuses on various aspects of breast radiation treatment planning, from simulation to field design. It covers the most common techniques including tangents, mono isocentric, dual isocentric, electron-photon match, and VMAT. This can serve as a guide for radiation oncology residents and medical students to advance their understanding of key aspects of breast radiation treatment and planning processes.

5.
Phys Imaging Radiat Oncol ; 30: 100577, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38707629

ABSTRACT

Background and purpose: Radiation-induced erectile dysfunction (RiED) commonly affects prostate cancer patients, prompting clinical trials across institutions to explore dose-sparing to internal-pudendal-arteries (IPA) for preserving sexual potency. IPA, challenging to segment, isn't conventionally considered an organ-at-risk (OAR). This study proposes a deep learning (DL) auto-segmentation model for IPA, using Computed Tomography (CT) and Magnetic Resonance Imaging (MRI) or CT alone to accommodate varied clinical practices. Materials and methods: A total of 86 patients with CT and MRI images and noisy IPA labels were recruited in this study. We split the data into 42/14/30 for model training, testing, and a clinical observer study, respectively. There were three major innovations in this model: 1) we designed an architecture with squeeze-and-excite blocks and modality attention for effective feature extraction and production of accurate segmentation, 2) a novel loss function was used for training the model effectively with noisy labels, and 3) modality dropout strategy was used for making the model capable of segmentation in the absence of MRI. Results: Test dataset metrics were DSC 61.71 ± 7.7 %, ASD 2.5 ± .87 mm, and HD95 7.0 ± 2.3 mm. AI segmented contours showed dosimetric similarity to expert physician's contours. Observer study indicated higher scores for AI contours (mean = 3.7) compared to inexperienced physicians' contours (mean = 3.1). Inexperienced physicians improved scores to 3.7 when starting with AI contours. Conclusion: The proposed model achieved good quality IPA contours to improve uniformity of segmentation and to facilitate introduction of standardized IPA segmentation into clinical trials and practice.

6.
J Appl Clin Med Phys ; : e14375, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38712917

ABSTRACT

PURPOSE: Online adaptive radiotherapy relies on a high degree of automation to enable rapid planning procedures. The Varian Ethos intelligent optimization engine (IOE) was originally designed for conventional treatments so it is crucial to provide clear guidance for lung SAbR plans. This study investigates using the Ethos IOE together with adaptive-specific optimization tuning structures we designed and templated within Ethos to mitigate inter-planner variability in meeting RTOG metrics for both online-adaptive and offline SAbR plans. METHODS: We developed a planning strategy to automate the generation of tuning structures and optimization. This was validated by retrospective analysis of 35 lung SAbR cases (total 105 fractions) treated on Ethos. The effectiveness of our planning strategy was evaluated by comparing plan quality with-and-without auto-generated tuning structures. Internal target volume (ITV) contour was compared between that drawn from CT simulation and from cone-beam CT (CBCT) at time of treatment to verify CBCT image quality and treatment effectiveness. Planning strategy robustness for lung SAbR was quantified by frequency of plans meeting reference plan RTOG constraints. RESULTS: Our planning strategy creates a gradient within the ITV with maximum dose in the core and improves intermediate dose conformality on average by 2%. ITV size showed no significant difference between those contoured from CT simulation and first fraction, and also trended towards decreasing over course of treatment. Compared to non-adaptive plans, adaptive plans better meet reference plan goals (37% vs. 100% PTV coverage compliance, for scheduled and adapted plans) while improving plan quality (improved GI (gradient index) by 3.8%, CI (conformity index) by 1.7%). CONCLUSION: We developed a robust and readily shareable planning strategy for the treatment of adaptive lung SAbR on the Ethos system. We validated that automatic online plan re-optimization along with the formulated adaptive tuning structures can ensure consistent plan quality. With the proposed planning strategy, highly ablative treatments are feasible on Ethos.

7.
Front Bioeng Biotechnol ; 12: 1387146, 2024.
Article in English | MEDLINE | ID: mdl-38638318

ABSTRACT

Butyrylcholinesterase (BChE) is widely expressed in multiple tissues and has a vital role in several key human disorders, such as Alzheimer's disease and tumorigenesis. However, the role of BChE in human disorders has not been investigated. Thus, to quantitatively detect and visualize dynamical variations in BChE activity is essential for exploring the biological roles of BChE in the progression of a number of human disorders. Herein, based on the substrate characteristics of BChE, we customized and synthesized three near-infrared (NIR) fluorescent probe substrates with cyanine-skeleton, and finally selected a NIR fluorescence probe substrate named CYBA. The CYBA demonstrated a significant increase in fluorescence when interacting with BChE, but mainly avoided AChE. Upon the addition of BChE, CYBA could be specifically hydrolyzed to TBO, resulting in a significant NIR fluorescence signal enhancement at 710 nm. Systematic evaluation revealed that CYBA exhibited exceptional chemical stability in complex biosamples and possessed remarkable selectivity and sensitivity towards BChE. Moreover, CYBA was successfully applied for real-time imaging of endogenous BChE activity in two types of nerve-related living cells. Additionally, CYBA demonstrated exceptional stability in the detection of complex biological samples in plasma recovery studies (97.51%-104.01%). Furthermore, CYBA was used to construct a high-throughput screening (HTS) method for BChE inhibitors using human plasma as the enzyme source. We evaluated inhibitory effects of a series of natural products and four flavonoids were identified as potent inhibitors of BChE. Collectively, CYBA can serve as a practical tool to track the changes of BChE activity in complicated biological environments due to its excellent capabilities.

8.
Hum Exp Toxicol ; 43: 9603271241249965, 2024.
Article in English | MEDLINE | ID: mdl-38662433

ABSTRACT

BACKGROUND: The mechanism of emamectin benzoate (EMB-a macrocyclic lactone insecticide like abamectin) action involves the disruption of glutamate-gated chloride channels and GABA receptors in insects, leading to paralysis and death. EMB overdose can breach the blood-brain barrier, resulting in severe poisoning and altered consciousness. AIM: Review EMB poisoning presentations in patients and reevaluate clinical manifestations. MATERIALS AND METHODS: This retrospective study reviewed (August 31, 2008-August 31, 2023) medical university hospital records. We analyzed symptoms, patient characteristics, vital signs, Glasgow Coma Scale scores, laboratory findings, and outcomes. RESULTS: Ten patients (males: 6, females: 4, median age = 64.5 years) experienced EMB poisoning. Common symptoms included sore throat, gastrointestinal distress, dyspnea, and altered consciousness; two patients showed laryngeal corrosive injuries. Management involved activated charcoal administration, gastric lavage, and intensive care unit admission. DISCUSSION: Sore throat and corrosive injuries were distinctive presentations of EMB poisoning, warranting vigilance. Potential mechanisms of corrosive injury include skin and eye irritation effects of EMB, the solvents of which might exert corrosive action. CONCLUSION: EMB poisoning manifests as diverse symptoms, including sore throat, gastrointestinal symptoms, central nervous system depression, and potential aspiration pneumonia. Recognizing and promptly managing EMB poisoning are crucial for enhancing patient outcomes and minimizing complications.


Subject(s)
Ivermectin , Ivermectin/analogs & derivatives , Humans , Ivermectin/poisoning , Ivermectin/toxicity , Female , Middle Aged , Male , Retrospective Studies , Aged , Insecticides/poisoning , Insecticides/toxicity , Adult , Aged, 80 and over
9.
Pract Radiat Oncol ; 2024 Apr 04.
Article in English | MEDLINE | ID: mdl-38579986

ABSTRACT

PURPOSE: Real-time adaptation of thoracic radiation plans is compelling because offline adaptive experiences show that tumor volumes and lung anatomy can change during therapy. We present and analyze a novel adaptive-on-demand (AOD) workflow combining online adaptive radiation therapy (o-ART) on the ETHOS system with image guided radiation therapy delivery on a Halcyon unit for conventional fractionated radiation therapy of locally advanced lung cancer (LALC). METHODS AND MATERIALS: We analyzed 26 patients with LALC treated with the AOD workflow, adapting weekly. We timed segments of the workflow to evaluate efficiency in a real-world clinic. Target coverage and organ at risk (OAR) doses were compared between adaptive plans (ADP) and nonadaptive scheduled plans (SCH). Planning robustness was evaluated by the frequency of preplanning goals achieved in ADP plans, stratified by tumor volume change. RESULTS: The AOD workflow was achievable within 30 minutes for most radiation fractions. Over the course of therapy, we observed an average 26.6% ± 23.3% reduction in internal target volume (ITV). Despite these changes, with o-ART, ITV and planning target volume (PTV) coverage (V100%) was 99.2% and 93.9% for all members of the cohort, respectively. This represented a 2.9% and 6.8% improvement over nonadaptive plans (P < .05), respectively. For tumors that grew >10%, V100% was 93.1% for o-ART and 76.4% for nonadaptive plans, representing a median 17.2% improvement in the PTV coverage (P < .05). In these plans, critical OAR constraints were met 94.1% of the time, whereas in nonadaptive plans, this figure was 81.9%. This represented reductions of 1.32 Gy, 1.34 Gy, or 1.75 Gy in the heart, esophagus, and lung, respectively. The effect was larger when tumors had shrunk more than 10%. Regardless of tumor volume alterations, the PTV/ITV coverage was achieved for all adaptive plans. Exceptional cases, where dose constraints were not met, were due to large initial tumor volumes or tumor growth. CONCLUSIONS: The AOD workflow is efficient and robust in responding to anatomic changes in LALC patients, providing dosimetric advantages over standard therapy. Weekly adaptation was adequate to keep pace with changes. This approach is a feasible alternative to conventional offline replanning workflows for managing anatomy changes in LALC radiation therapy.

10.
Radiother Oncol ; 197: 110178, 2024 Mar 06.
Article in English | MEDLINE | ID: mdl-38453056

ABSTRACT

OBJECTIVE: We explore the potential dosimetric benefits of reducing treatment volumes through daily adaptive radiation therapy for head and neck cancer (HNC) patients using the Ethos system/Intelligent Optimizer Engine (IOE). We hypothesize reducing treatment volumes afforded by daily adaption will significantly reduce the dose to adjacent organs at risk. We also explore the capability of the Ethos IOE to accommodate this highly conformal approach in HNC radiation therapy. METHODS: Ten HNC patients from a phase II trial were chosen, and their cone-beam CT (CBCT) scans were uploaded to the adaptive RT (ART) emulator. A new initial reference plan was generated using both a 1 mm and 5 mm planning target volume (PTV) expansion. Daily adaptive ART plans (1 mm) were simulated from the clinical CBCT taken every fifth fraction. Additionally, using physician-modified ART contours the larger 5 mm plan was recalculated on this recontoured on daily anatomy. Changes in target and OAR contours were measured using Dice coefficients as a surrogate of clinician effort. PTV coverage and organ-at-risk (OAR) doses were statistically compared, and the robustness of each ART plan was evaluated at fractions 5 and 35 to observe if OAR doses were within 3 Gy of pre-plan. RESULTS: This study involved six patients with oropharynx and four with larynx cancer, totaling 70 adaptive fractions. The primary and nodal gross tumor volumes (GTV) required the most adjustments, with median Dice scores of 0.88 (range: 0.80-0.93) and 0.83 (range: 0.66-0.91), respectively. For the 5th and 35th fraction plans, 80 % of structures met robustness criteria (quartile 1-3: 67-100 % and 70-90 %). Adaptive planning improved median PTV V100% coverage for doses of 70 Gy (96 % vs. 95.6 %), 66.5 Gy (98.5 % vs. 76.5 %), and 63 Gy (98.9 % vs. 74.9 %) (p < 0.03). Implementing ART with total volume reduction yielded median dose reductions of 7-12 Gy to key organs-at-risk (OARs) like submandibular glands, parotids, oral cavity, and constrictors (p < 0.05). CONCLUSIONS: The IOE enables feasible daily ART treatments with reduced margins while enhancing target coverage and reducing OAR doses for HNC patients. A phase II trial recently finished accrual and forthcoming analysis will determine if these dosimetric improvements correlate with improved patient-reported outcomes.

11.
Angew Chem Int Ed Engl ; 63(21): e202402044, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38469657

ABSTRACT

The nuanced role of spin effects remains a critical gap in designing proficient open-shell catalysts. This study elucidates an iron-catalyzed allylic C(sp3)-H silylation/alkyne hydrosilylation reaction, in which the spin state of the open-shell iron catalyst dictates the reaction kinetics and pathway. Specifically, spin crossover led to alkyne hydrosilylation, whereas spin conservation resulted in a novel allylic C(sp3)-H silylation reaction. This chemoselectivity, governed by the spin-crossover efficiency, reveals an unexpected dimension in spin effects and a first in the realm of transition-metal-catalyzed in situ silylation of allylic C(sp3)-H bonds, which had been previously inhibited by the heightened reactivity of alkenes in hydrosilylation reactions. Furthermore, this spin crossover can either accelerate or hinder the reaction at different stages within a single catalytic reaction, a phenomenon scarcely documented. Moreover, we identify a substrate-assisted C-H activation mechanism, a departure from known ligand-assisted processes, offering a fresh perspective on C-H activation strategies.

12.
J Formos Med Assoc ; 2024 Feb 15.
Article in English | MEDLINE | ID: mdl-38360489

ABSTRACT

BACKGROUND: Endovascular thrombectomy (EVT) is a time-sensitive treatment for acute ischemic stroke with large vessel occlusion. To optimize transfer efficiency, a web-based platform was introduced in the Tainan Stroke Network (TSN). We assessed its application and effectiveness in regional stroke care. METHOD: This new web-based platform containing a questionnaire-style interface was introduced on October 1, 2021. To assess the transfer efficiency and patient outcomes, acute stroke patients transferred from PSCs to CSC for EVT from April 01, 2020, to December 30, 2022, were enrolled. The patients were classified into the traditional transferal pathway (TTP) group and the new transferal pathway (NTP) group depending on mode of transfer. Patient characteristics, time segments after stroke onset and outcome were compared between groups. RESULT: A total of 104 patients were enrolled, with 77 in the TTP group and 27 in the NTP group. Compared to the TTP group, the NTP group had a significantly shorter onset-to-CSC door time (TTP vs. NTP: 267 vs. 198 min; p = 0.041) and a higher EVT rate (TTP vs. NTP: 18.2% vs. 48.1%, p = 0.002). Among EVT patients, those in the NTP group had a significantly shorter CSC door-to-puncture time (TTP vs. NTP: 131.5 vs. 110 min; p = 0.029). The NTP group had a higher rate of good functional outcomes at 3 months (TTP vs. NTP: 21% vs. 61.5%; p = 0.034). CONCLUSION: This new web-based EVT transfer system provides notable improvements in clinical outcomes, transfer efficiency, and EVT execution for potential EVT candidates without markedly changing the regional stroke care paradigm.

13.
ACS Chem Neurosci ; 15(3): 593-607, 2024 02 07.
Article in English | MEDLINE | ID: mdl-38214579

ABSTRACT

Objective: Schisandrin B (Sch B) is a bioactive dibenzocyclooctadiene derizative that is prevalent in the fruit of Schisandra chinensis. Numerous studies have demonstrated that Sch B has a neuroprotective action by reducing oxidative stress and effectively preventing inflammation. It follows that Sch B is a potential treatment for Alzheimer's disease (AD). However, the drug's solubility, bioavailability, and lower permeability of the blood-brain barrier (BBB) can all reduce its efficacy during the therapy process. Therefore, this study constructed borneol-modified schisandrin B micelles (Bor-Sch B-Ms), which increase brain targeting by accurately delivering medications to the brain, effectively improving bioavailability. High therapeutic efficacy has been achieved at the pathological site. Methods: Bor-Sch B-Ms were prepared using the thin film dispersion approach in this article. On the one hand, to observe the targeting effect of borneol, we constructed a blood-brain barrier (BBB) model in vitro and studied the ability of micelles to cross the BBB. On the other hand, the distribution of micelle drugs and their related pharmacological effects on neuroinflammation, oxidative stress, and neuronal damage were studied through in vivo administration in mice. Results: In vitro studies have demonstrated that the drug uptake of bEnd.3 cells was increased by the borneol alteration on the surface of the nano micelles, implying that Bor-Sch B-Ms can promote the therapeutic effect of N2a cells. This could result in more medicines entering the BBB. In addition, in vivo studies revealed that the distribution and circulation time of medications in the brain tissue were significantly higher than those in other groups, making it more suitable for the treatment of central nervous system diseases. Conclusion: As a novel nanodrug delivery system, borneol modified schisandrin B micelles have promising research prospects in the treatment of Alzheimer's disease.


Subject(s)
Alzheimer Disease , Blood-Brain Barrier , Camphanes , Lignans , Polycyclic Compounds , Mice , Animals , Micelles , Alzheimer Disease/drug therapy , Endothelial Cells , Cyclooctanes
14.
iScience ; 27(1): 108690, 2024 Jan 19.
Article in English | MEDLINE | ID: mdl-38235340

ABSTRACT

Prenatal stress has been extensively documented as a contributing factor to adverse cardiac development and function in fetuses and infants. The release of glucocorticoids (GCs), identified as a significant stressor, may be a potential factor inducing cardiac hypertrophy. However, the underlying mechanism remains largely unknown. Herein, we discovered that corticosterone (CORT) overload induced cardiac hypertrophy in embryonic chicks and fetal mice in vivo, as well as enlarged cardiomyocytes in vitro. The impaired mitochondria dynamics were observed in CORT-exposed cardiomyocytes, accompanied by dysfunction in oxidative phosphorylation and ATP production. This phenomenon was found to be linked to decreased mitochondrial fusion protein mitofusin 2 (MFN2). Subsequently, we found that CORT facilitated the ubiquitin-proteasome-system-dependent degradation of MFN2 with an enhanced binding of appoptosin to MFN2, serving as the underlying cause. Collectively, our findings provide a comprehensive understanding of the mechanisms by which exposure to stress hormones induces cardiac hypertrophy in fetuses.

15.
Adv Radiat Oncol ; 9(1): 101319, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38260220

ABSTRACT

Purpose: Recently developed online adaptive radiation therapy (OnART) systems enable frequent treatment plan adaptation, but data supporting a dosimetric benefit in postoperative head and neck radiation therapy (RT) are sparse. We performed an in silico dosimetric study to assess the potential benefits of a single versus weekly OnART in the treatment of patients with head and neck squamous cell carcinoma in the adjuvant setting. Methods and Materials: Twelve patients receiving conventionally fractionated RT over 6 weeks and 12 patients receiving hypofractionated RT over 3 weeks on a clinical trial were analyzed. The OnART emulator was used to virtually adapt either once midtreatment or weekly based on the patient's routinely performed cone beam computed tomography. The planning target volume (PTV) coverage, dose heterogeneity, and cumulative dose to the organs at risk for these 2 adaptive approaches were compared with the nonadapted plan. Results: In total, 13, 8, and 3 patients had oral cavity, oropharynx, and larynx primaries, respectively. In the conventionally fractionated RT cohort, weekly OnART led to a significant improvement in PTV V100% coverage (6.2%), hot spot (-1.2 Gy), and maximum cord dose (-3.1 Gy), whereas the mean ipsilateral parotid dose increased modestly (1.8 Gy) versus the nonadapted plan. When adapting once midtreatment, PTV coverage improved with a smaller magnitude (0.2%-2.5%), whereas dose increased to the ipsilateral parotid (1.0-1.1 Gy) and mandible (0.2-0.7 Gy). For the hypofractionated RT cohort, similar benefit was observed with weekly OnART, including significant improvement in PTV coverage, hot spot, and maximum cord dose, whereas no consistent dosimetric advantage was seen when adapting once midtreatment. Conclusions: For head and neck squamous cell carcinoma adjuvant RT, there was a limited benefit of single OnART, but weekly adaptations meaningfully improved the dosimetric criteria, predominantly PTV coverage and dose heterogeneity. A prospective study is ongoing to determine the clinical benefit of OnART in this setting.

16.
Biomed Phys Eng Express ; 10(2)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38241733

ABSTRACT

This study explored the feasibility of on-couch intensity modulated radiotherapy (IMRT) planning for prostate cancer (PCa) on a cone-beam CT (CBCT)-based online adaptive RT platform without an individualized pre-treatment plan and contours. Ten patients with PCa previously treated with image-guided IMRT (60 Gy/20 fractions) were selected. In contrast to the routine online adaptive RT workflow, a novel approach was employed in which the same preplan that was optimized on one reference patient was adapted to generate individual on-couch/initial plans for the other nine test patients using Ethos emulator. Simulation CTs of the test patients were used as simulated online CBCT (sCBCT) for emulation. Quality assessments were conducted on synthetic CTs (sCT). Dosimetric comparisons were performed between on-couch plans, on-couch plans recomputed on the sCBCT and individually optimized plans for test patients. The median value of mean absolute difference between sCT and sCBCT was 74.7 HU (range 69.5-91.5 HU). The average CTV/PTV coverage by prescription dose was 100.0%/94.7%, and normal tissue constraints were met for the nine test patients in on-couch plans on sCT. Recalculating on-couch plans on the sCBCT showed about 0.7% reduction of PTV coverage and a 0.6% increasing of hotspot, and the dose difference of the OARs was negligible (<0.5 Gy). Hence, initial IMRT plans for new patients can be generated by adapting a reference patient's preplan with online contours, which had similar qualities to the conventional approach of individually optimized plan on the simulation CT. Further study is needed to identify selection criteria for patient anatomy most amenable to this workflow.


Subject(s)
Prostatic Neoplasms , Radiotherapy, Image-Guided , Male , Humans , Feasibility Studies , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/radiotherapy
18.
Epilepsy Behav ; 151: 109647, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38232558

ABSTRACT

Childhood absence epilepsy (CAE) is a common type of idiopathic generalized epilepsy, manifesting as daily multiple absence seizures. Although seizures in most patients can be adequately controlled with first-line antiseizure medication (ASM), approximately 25 % of patients respond poorly to first-line ASM. In addition, an accurate method for predicting first-line medication responsiveness is lacking. We used the quantitative electroencephalogram (QEEG) features of patients with CAE along with machine learning to predict the therapeutic effects of valproic acid in this population. We enrolled 25 patients with CAE from multiple medical centers. Twelve patients who required additional medication for seizure control or who were shifted to another ASM and 13 patients who achieved seizure freedom with valproic acid within 6 months served as the nonresponder and responder groups. Using machine learning, we analyzed the interictal background EEG data without epileptiform discharge before ASM. The following features were analyzed: EEG frequency bands, Hjorth parameters, detrended fluctuation analysis, Higuchi fractal dimension, Lempel-Ziv complexity (LZC), Petrosian fractal dimension, and sample entropy (SE). We applied leave-one-out cross-validation with support vector machine, K-nearest neighbor (KNN), random forest, decision tree, Ada boost, and extreme gradient boosting, and we tested the performance of these models. The responders had significantly higher alpha band power and lower delta band power than the nonresponders. The Hjorth mobility, LZC, and SE values in the temporal, parietal, and occipital lobes were higher in the responders than in the nonresponders. Hjorth complexity was higher in the nonresponders than in the responders in almost all the brain regions, except for the leads FP1 and FP2. Using KNN classification with theta band power in the temporal lobe yielded optimal performance, with sensitivity of 92.31 %, specificity of 76.92 %, accuracy of 84.62 %, and area under the curve of 88.46 %.We used various EEG features along with machine learning to accurately predict whether patients with CAE would respond to valproic acid. Our method could provide valuable assistance for pediatric neurologists in selecting suitable ASM.


Subject(s)
Epilepsy, Absence , Child , Humans , Epilepsy, Absence/diagnosis , Epilepsy, Absence/drug therapy , Valproic Acid/therapeutic use , Seizures/drug therapy , Electroencephalography/methods , Machine Learning
19.
Pract Radiat Oncol ; 14(2): e159-e164, 2024.
Article in English | MEDLINE | ID: mdl-37923136

ABSTRACT

PURPOSE: Online adaptive radiation therapy (ART) has emerged as a new treatment modality for cervical cancer. Daily online adapting improves target coverage and organ-at-risk (OAR) sparing compared with traditional image guided radiation therapy (IGRT); however, the required resources may not be feasible in a busy clinical setting. Less frequent adapting may still benefit cervical cancer patients due to large volume changes of the uterocervix of the treatment course. In this study, the dosimetry from different online adapt-on-demand schedules was compared. MATERIALS AND METHODS: A retrospective cohort of 10 patients with cervical cancer treated with 260 fractions of definitive daily online ART was included. Plans with different adaptation schedules were simulated with adaptations weekly, every other week, once during treatment, and no adaptations (IGRT). These plans were applied to the synthetic computed tomography (CT) images and contours generated during the patient's delivered daily adaptive workflow. The dosimetry of the weekly replan, every-other-week replan, once replan, and IGRT plans were compared using a paired t test. RESULTS: Compared with traditional IGRT plans, weekly and every-other-week ART plans had similar clinical target volume (CTV) coverage, but statistically significant improved sparing of OARs. Weekly and every-other-week ART had reduced bowel bag V40 by 1.57% and 1.41%, bladder V40 by 3.82% and 1.64%, rectum V40 by 8.49% and 7.50%, and bone marrow Dmean by 0.81% and 0.61%, respectively. Plans with a single adaptation had statistically significantly worse target coverage, and moderate improvements in OAR sparing. Of the 18-dose metrics evaluated, improvements were seen in 15 for weekly ART, 14 for every-other-week ART, and 10 for single ART plans compared with IGRT. When every-other-week ART was compared with weekly ART, both plans had similar CTV coverage and OAR sparing with only small improvements in bone marrow dosimetry with weekly ART. CONCLUSIONS: This retrospective work compares different adapt-on-demand treatment schedules using data collected from patients treated with daily online adaptive radiation therapy. Results suggest weekly or every-other-week online ART is beneficial for reduced OAR dose compared with IGRT by exploiting the gradual changes in the uterocervix target volume.


Subject(s)
Radiotherapy, Image-Guided , Uterine Cervical Neoplasms , Humans , Female , Uterine Cervical Neoplasms/radiotherapy , Retrospective Studies , Benchmarking , Pelvis
20.
Med Phys ; 51(1): 18-30, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37856190

ABSTRACT

BACKGROUND: Online adaptive radiotherapy (ART) involves the development of adaptable treatment plans that consider patient anatomical data obtained right prior to treatment administration, facilitated by cone-beam computed tomography guided adaptive radiotherapy (CTgART) and magnetic resonance image-guided adaptive radiotherapy (MRgART). To ensure accuracy of these adaptive plans, it is crucial to conduct calculation-based checks and independent verification of volumetric dose distribution, as measurement-based checks are not practical within online workflows. However, the absence of comprehensive, efficient, and highly integrated commercial software for secondary dose verification can impede the time-sensitive nature of online ART procedures. PURPOSE: The main aim of this study is to introduce an efficient online quality assurance (QA) platform for online ART, and subsequently evaluate it on Ethos and Unity treatment delivery systems in our clinic. METHODS: To enhance efficiency and ensure compliance with safety standards in online ART, ART2Dose, a secondary dose verification software, has been developed and integrated into our online QA workflow. This implementation spans all online ART treatments at our institution. The ART2Dose infrastructure comprises four key components: an SQLite database, a dose calculation server, a report generator, and a web portal. Through this infrastructure, file transfer, dose calculation, report generation, and report approval/archival are seamlessly managed, minimizing the need for user input when exporting RT DICOM files and approving the generated QA report. ART2Dose was compared with Mobius3D in pre-clinical evaluations on secondary dose verification for 40 adaptive plans. Additionally, a retrospective investigation was conducted utilizing 1302 CTgART fractions from ten treatment sites and 1278 MRgART fractions from seven treatment sites to evaluate the practical accuracy and efficiency of ART2Dose in routine clinical use. RESULTS: With dedicated infrastructure and an integrated workflow, ART2Dose achieved gamma passing rates that were comparable to or higher than those of Mobius3D. Additionally, it significantly reduced the time required to complete pre-treatment checks by 3-4 min for each plan. In the retrospective analysis of clinical CTgART and MRgART fractions, ART2Dose demonstrated average gamma passing rates of 99.61 ± 0.83% and 97.75 ± 2.54%, respectively, using the 3%/2 mm criteria for region greater than 10% of prescription dose. The average calculation times for CTgART and MRgART were approximately 1 and 2 min, respectively. CONCLUSION: Overall, the streamlined implementation of ART2Dose notably enhances the online ART workflow, offering reliable and efficient online QA while reducing time pressure in the clinic and minimizing labor-intensive work.


Subject(s)
Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Humans , Radiotherapy Planning, Computer-Assisted/methods , Retrospective Studies , Software , Radiotherapy, Intensity-Modulated/methods , Tomography, X-Ray Computed , Radiotherapy Dosage
SELECTION OF CITATIONS
SEARCH DETAIL
...