Respir Investig ; 62(4): 640-644, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38749078

ABSTRACT

BACKGROUND: Airway stenting is an established procedure for treating oncological emergencies in patients with airway disorders. In patients with airway hemorrhage, respiratory conditions may worsen during stenting. Bronchial artery embolization (BAE) is useful to prevent bleeding from the bronchus. We aimed to evaluate the efficacy and safety of airway stenting after BAE in patients with malignant airway disorders. METHODS: The medical records of all patients who underwent airway stenting following BAE at the National Hospital Organization Okayama Medical Center between 2016 and 2023 were retrospectively reviewed. RESULTS: Thirteen procedures (11 silicone Y stents, one hybrid stent, and one self-expandable metallic stent) were performed. The median duration from BAE to airway stenting was one day (range: 1-5 days). Nine patients experienced tumor shrinkage, and none experienced severe bleeding after BAE during the stent procedure. No other major complications were associated with the stent placement. The median survival time after stenting was 169 days (range; 24-1086). No serious complications caused by BAE, such as spinal cord infarction, were observed. CONCLUSIONS: Airway stent placement was safely performed after BAE without severe bleeding or acute respiratory failure. BAE, followed by airway stenting, is useful.

3.
Cardiovasc Interv Ther ; 38(4): 414-423, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37278956

ABSTRACT

The outcome of transcatheter aortic valve replacement (TAVR) for patients with bicuspid aortic valve (BAV) remains unclear, particularly among Asian patients that are known to have different valvular morphology and lower body habitus. This study investigated patient characteristics, procedural and 1-year outcome of TAVR for BAV within national TAVR registry in Japan. The patient-level data were extracted from the J-TVT (Japanese Transcatheter Valvular Therapy) registry between August 2013 and December 2018; overall, there were 423 patients (2.5%) with BAV and 16,802 patients with tricuspid aortic valve (TAV). At baseline, patients with BAV were younger and had less arteriosclerotic comorbidities. There was no statistically significant difference between BAV and TAV groups in conversion to surgery (0.5% vs. 1.1%, p = 0.34) and 30-day mortality (0.5% vs. 1.3%, p = 0.18). Cumulative all-cause survival and survival from major adverse events were analyzed. Cox proportional hazard regression model was used to estimate the hazard ratio. All-cause mortality and major adverse event rate at 1 year were comparable between the two groups. Relative hazard for all-cause mortality for BAV compared to TAV was 1.01 (0.70-1.45; p = 0.96), and for major adverse event was 0.94 (0.69-1.27; p = 0.67). From the Japanese nationwide TAVR registry, procedural and 1-year outcome of TAVR in BAV was as favorable as TAVR in TAV.


Subject(s)
Aortic Valve Stenosis , Bicuspid Aortic Valve Disease , Heart Valve Diseases , Mitral Valve Stenosis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Bicuspid Aortic Valve Disease/complications , Bicuspid Aortic Valve Disease/surgery , Constriction, Pathologic/etiology , East Asian People , Treatment Outcome , Heart Valve Diseases/surgery , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Mitral Valve Stenosis/complications , Registries
4.
J Heart Lung Transplant ; 42(6): 786-794, 2023 06.
Article in English | MEDLINE | ID: mdl-36792382

ABSTRACT

BACKGROUND: Although pulmonary endarterectomy is the treatment of choice for chronic thromboembolic pulmonary hypertension, not all patients are eligible. While balloon pulmonary angioplasty is an alternative for such patients, its efficacy and safety may differ between patients with and without surgically accessible lesions. METHODS: This study involved 344 patients treated with balloon pulmonary angioplasty who were ineligible for pulmonary endarterectomy. Based on the angiographical lesion location, patients were divided into the surgically accessible (Group 1) and inaccessible (Group 2) groups, and percent changes in hemodynamics and clinical parameters before and after balloon pulmonary angioplasty were investigated. We also conducted survival analyses using Kaplan-Meier analysis. RESULTS: While no differences in baseline characteristics were identified between the groups, balloon pulmonary angioplasty significantly improved hemodynamics in both groups, without any difference regarding the incidence of complications. Meanwhile, the percent changes in the mean pulmonary arterial pressure, pulmonary vascular resistance, 6-min walk distance, right ventricular area index on echocardiography, and the achievement rate of World Health Organization functional class I after balloon pulmonary angioplasty were significantly lower in Group 1 than in Group 2. The cumulative survival rates at 1, 5, and 10 years after balloon pulmonary angioplasty were not significantly different between the two groups (Group 1: 92.5%, 86.1%, 84.3%; and Group 2: 96.5%, 92.9%, 90.1%, respectively). CONCLUSIONS: The outcome of balloon pulmonary angioplasty in inoperable patients with surgically accessible proximal lesions was acceptable; however, further investigations are necessary to clarify the optimal treatment for such patients.


Subject(s)
Angioplasty, Balloon , Hypertension, Pulmonary , Pulmonary Embolism , Humans , Hypertension, Pulmonary/etiology , Hypertension, Pulmonary/surgery , Pulmonary Artery/surgery , Pulmonary Embolism/complications , Pulmonary Embolism/surgery , Treatment Outcome , Chronic Disease
5.
JACC Asia ; 2(5): 635-644, 2022 Oct.
Article in English | MEDLINE | ID: mdl-36518724

ABSTRACT

Background: Although transcatheter aortic valve replacement (TAVR) has demonstrated favorable outcomes in randomized studies, there remains a sizable group of patients in whom TAVR may be futile. Characterizing the survival rate in a wide array of patients undergoing TAVR can help develop effective strategies for improving the allocation of medial resources. Objectives: The aim of this study was to develop a risk model to estimate 1-year mortality after TAVR from a representative nationwide registry in Japan. Methods: The J-TVT (Japan Transcatheter Valve Therapies) registry contains complete data, including 1-year outcomes, on patients undergoing TAVR in Japan. A total of 17,655 patients underwent TAVR between 2013 and 2018. They were randomly divided into 2 groups in a 7:3 ratio to form a derivation cohort of 12,316 patients and a validation cohort of 5,339 patients. A risk model was constructed for 1-year mortality in the derivation cohort, and its discrimination and calibration were assessed in the validation cohort. Results: The mean age of all registered patients was 84.4 years, and 68.8% were women. The mean body size area was 1.43 m2, and the mean Society of Thoracic Surgeons Predicted Risk of Mortality score was 7.3%. The estimated 1-year survival was 91.8%; 202 and 1,316 deaths were observed at 30 days and 1 year, respectively; The estimated C index for the developed model was 0.733 (95% CI: 0.709-0.757) in the validation cohort, with good calibration. Conclusions: A prediction model for 1-year survival following TAVR derived from a national clinical database performed well and should aid physicians managing TAVR patients.

6.
Biocontrol Sci ; 27(4): 217-222, 2022.
Article in English | MEDLINE | ID: mdl-36567118

ABSTRACT

The remote bactericidal effect of TiO2 photocatalyst, i.e., the bactericidal effect away from the photocatalyst, was successfully achieved using a humidified airflow. The TiO2 photocatalyst used was anatase-type TiO2 nanoparticles (NPs) annealed with a low-temperature O2 plasma. For comparison, anatase-type TiO2 NPs annealed in the air were used. The bacteria, Bacillus subtilis, were placed away from the TiO2 NPs. The plasma-assisted-annealed TiO2 NPs significantly inactivated 99% of the bacterial cells in 5 h, whereas the pristine and air-annealed TiO2 NPs inactivated 88-90% of the bacterial cells. The remote bactericidal effect of plasmaassisted-annealed TiO2 NPs would be attributed to a larger amount of H2O2 molecules traveled by the airflow from the TiO2 NPs. The molecules were generated by chemically reacting more photoexcited carriers on the TiO2 surface with H2O and O2 in the airflow. These photoexcited carriers originated from more oxygen-based species adsorbed and more oxygen vacancies introduced on the TiO2 surface by the plasma-assisted-annealing.


Subject(s)
Hydrogen Peroxide , Nanoparticles , Hydrogen Peroxide/pharmacology , Temperature , Nanoparticles/chemistry , Oxygen , Anti-Bacterial Agents/pharmacology
7.
Circ J ; 86(11): 1764-1768, 2022 10 25.
Article in English | MEDLINE | ID: mdl-36184556

ABSTRACT

BACKGROUND: The use of hybrid operating rooms (HOR) for transcatheter aortic valve implantation (TAVI) has increased, so radiation exposure during procedures that use X-ray fluoroscopy is a fundamental problem not only for patients but also for surgeons and interventional cardiologists, increasing the risk of cataracts among operators. We investigated the efficacy of leaded glasses and protective sheets for ocular radiation protection.Methods and Results: Between January 2020 and February 2021 we enrolled 54 TAVI procedures using the transfemoral approach. The subjects were divided into a curtain protection group (Group C, n=20), glass protection group (Group G, n=17), and sheet protection group (Group S, n=17). The cumulative dose (CD) of the operators showed a decreasing trend in Group S compared with the other two groups. The CD normalized by dose area product (CD/DAP) of the operators was significantly reduced in Group S compared with Group C. However, Group G showed no significant difference compared with Group C. Regarding the distribution of CD/DAP, Group S had a significantly lower distribution than that in groups C and G. CONCLUSIONS: Protective sheets provide more stable radiation protection than conventional curtains or leaded glasses.


Subject(s)
Aortic Valve Stenosis , Radiation Exposure , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/surgery , Radiation Dosage , Risk Factors , Radiation Exposure/adverse effects , Radiation Exposure/prevention & control , Fluoroscopy/adverse effects , Aortic Valve/surgery , Treatment Outcome
8.
Article in English | MEDLINE | ID: mdl-36604286

ABSTRACT

BACKGROUND: Coronary artery access after repeat transcatheter aortic valve replacement (TAV-in-TAV) is reportedly more difficult because leaflet displacement of the first transcatheter heart valve (THV) impairs coronary cannulation; however, its effects in small patients are unknown. This study aimed to simulate coronary accessibility after TAV-in-TAV in patients of small body size. METHODS: We retrospectively analyzed computed tomography scans after initial THV implantation and classified patients by THV and coronary artery location, valve-to-aorta distance, and valve-to-coronary distance. Risks were compared between the SAPIEN and CoreValve/Evolut series, among THV generations, and between bicuspid and tricuspid aortic valves in the CoreValve/Evolut series. RESULTS: A total of 254 patients (SAPIEN series, n = 164; CoreValve/Evolut series, n = 90) were enrolled. The average body surface area of the patients was 1.44 m2. Patients were classified as "feasible" (26%), "theoretically feasible with low risk" (19.7%), "theoretically feasible with high risk" (8.7%), or "unfeasible" (45.8%). The "unfeasible" rate was significantly higher in the CoreValve/Evolut series than in the SAPIEN series (78.9% vs 26.2%; P < .001). A significantly higher "unfeasible" rate was identified in the current model of SAPIEN (SAPIEN, 8.3%; SAPIENXT, 1.8%; SAPIEN3, 48.2%; P < .001), but not in the CoreValve/Evolut series (CoreValve, 83.3%; Evolut R, 80.0%; Evolut PRO, 71.4%; P = .587). Patients with a bicuspid aortic valve had a lower "unfeasible" rate compared to those with a tricuspid aortic valve (60.0% vs 86.2%; P = .014). CONCLUSIONS: Patients of small body size may have a high probability of "unfeasible" coronary access after TAV-in-TAV, especially when treated with current high-frame devices, suggesting the need for careful strategic planning for initial THV implantation.

9.
Cardiovasc Interv Ther ; 36(3): 298-306, 2021 Jul.
Article in English | MEDLINE | ID: mdl-32537725

ABSTRACT

Differences in guiding catheters (GCs) manipulations and selections among different access sites are currently unclear. We examined the differences in the routes of GCs for the left coronary artery (LCA) among the right radial, left radial, and femoral approaches. We used a combined angiography-computed tomography (CT) system that enabled to perform CT scans during percutaneous coronary intervention (PCI). We enrolled 88 patients who underwent CT scans during LCA PCI or percutaneous transluminal septal myocardial ablation. To evaluate the route of GCs, we analyzed the positions of the catheter's contact point on the contralateral aortic wall to the LCA ostium, which were expressed by the angle formed by the vertical line and the diagonal line from the GC shaft to the center of the aorta. The procedures were performed via the right radial in 47 cases, left radial in 20, and femoral approach in 21. The positions of the catheter's contact point were significantly different depending on the approaches (interquartile range - 3.7 [- 14.3 to 7.8], - 46.5 [- 76.9 to - 9.3], and - 30.7 [- 39.4 to - 22.4] degrees, respectively; p < 0.001). Multivariate analysis demonstrated that access sites and LCA ostium locations had significant impacts on the positions of the catheter's contact point. The routes of LCA GCs were different among the right radial, left radial, and femoral approaches.


Subject(s)
Computed Tomography Angiography/instrumentation , Coronary Angiography/methods , Coronary Vessels/surgery , Aged , Aorta , Coronary Vessels/diagnostic imaging , Equipment Design , Female , Humans , Male , Percutaneous Coronary Intervention/methods , Risk Factors
10.
Eur Heart J Case Rep ; 4(3): 1-4, 2020 Jun.
Article in English | MEDLINE | ID: mdl-32617490

ABSTRACT

BACKGROUND: Aortic root rupture is a severe complication of balloon-expandable transcatheter aortic valve replacement (TAVR). Although previous studies have revealed several risk factors for this complication, predicting this complication is occasionally difficult. CASE SUMMARY: A 78-year-old male patient underwent TAVR via a transfemoral approach using a 29-mm balloon-expandable valve. No recognized risk factors for aortic root rupture existed in pre-procedural multi-detector computed tomography (MDCT) analysis. However, after the valve deployment, sudden haemodynamic collapse occurred. Transoesophageal echocardiography revealed pericardial effusion, which led to an immediate diagnosis of cardiac tamponade following aortic root rupture. Following pericardial drainage via a subxiphoid approach, the haemodynamics were immediately stabilized. After 10 days of close observation, the patient was discharged on Day 39 without additional problems. He was still alive at the 6-month follow-up without sequelae. DISCUSSION: Established risk factors for aortic root rupture include >20% area oversizing, bicuspid aortic valve, small annulus (<20 mm), shallow sinus of Valsalva (SOV) compared with the aortic annulus, and massive annular or subannular calcification. Our patient did not have any of the recognized risk factors for aortic root rupture, suggesting the existence of other factors. Pre-procedural MDCT showed a flat calcification orthogonal to the aortic root wall, and post-procedural MDCT revealed that this calcification penetrated the SOV with extravasation. Thus, we suggest that a flat calcification orthogonal to the aortic root wall might be an additional risk factor for aortic root rupture.

11.
Anal Chem ; 92(1): 758-765, 2020 Jan 07.
Article in English | MEDLINE | ID: mdl-31820636

ABSTRACT

A polychromatic simultaneous wavelength-dispersive X-ray fluorescence (PS-WDXRF) spectrometer can measure the valence changes of 3d transition metals with high precision in the laboratory. Adjustment and maintenance of the drive mechanism are unnecessary, and high-precision measurements are possible in a short time because the optical system has no moving parts and is compact. We have developed a PS-WDXRF spectrometer with improved analytical precision that can measure simultaneously the valence changes of three main elements, Mn, Co, and Ni, which are used as cathode materials in Li-ion batteries (LIBs). In this study, the analytical precision of the spectrometer is evaluated, and its precision is confirmed with actual battery cathodes. The identification precision of the fluorescent X-ray peak energy is <0.015 eV, and the valence identification precision is obtained to be <0.06. LiNi0.5Co0.2Mn0.3O2 (NCM523)-based LIB cathodes are analyzed under conditions maintaining this precision, and the valence changes of the 3d transition metals in NCM523 during charging and discharging are found to be 0.68 for Ni, 0.19 for Co, and 0.08 for Mn. These results indicate that Ni contributes the most to the redox process in NCM523-based LIBs, Co contributes slightly, and Mn does not contribute.

12.
Am J Cardiol ; 124(4): 573-579, 2019 08 15.
Article in English | MEDLINE | ID: mdl-31255236

ABSTRACT

Few studies have evaluated transcatheter aortic valve implantation (TAVI) beyond 5 years. We investigated long-term outcomes (≥5 years) and transcatheter heart valve (THV) performance in patients who had undergone TAVI at least 5 years previously, based on annual follow-up. We reviewed 114 consecutive patients who were of high surgical risk or inoperable and underwent TAVI for severe aortic stenosis from October 2009 to November 2013. There was no lost to follow-up, and median time to death or latest follow-up was 5.0 years (range: 0.1 to 8.5). Structural valve degeneration (SVD) was defined on transthoracic echocardiography (TTE) as follows: (1) mean pressure gradient ≥20 mm Hg with a >10 mm Hg increase from the post-TAVI baseline, and/or (2) moderate or severe transvalvular regurgitation. The mean patient age was 82.7 ± 6.4 years, and 37.7% of patients were men. Median Society of Thoracic Surgeons score was 7.6% (interquartile range 5.8 to 10.9). TTE ≥5 years was 76.1% complete (51 of 67 patients who survived ≥5 years postoperatively). The estimated cumulative survival rates at 1, 3, 5, and 7 years were 88.6%, 72.8%, 58.8%, and 45.3%, respectively. Albumin <3.5 g/dl was strongly associated with increased long-term mortality on multivariate analysis. Longitudinal TTE confirmed durable performance of THV up to 7 years in the majority of patients; however, 6 patients (5.3% of the total cohort) experienced SVD during the follow-up. In conclusion, this study demonstrated favorable long-term survival and stable THV performance after TAVI, although SVD was not rare.


Subject(s)
Aortic Valve Stenosis/surgery , Outcome Assessment, Health Care , Transcatheter Aortic Valve Replacement , Aged, 80 and over , Aortic Valve Stenosis/mortality , Female , Humans , Japan , Male , Survival Rate
13.
Circ Rep ; 1(3): 142-148, 2019 Jan 16.
Article in English | MEDLINE | ID: mdl-33693129

ABSTRACT

Background: The outcome of redo transcatheter aortic valve (TAV) implantation (TAVI) is unknown for TAV structural valve degeneration (SVD). This paper reports the initial results of redo TAVI for TAV-SVD in Japanese patients. Methods and Results: Of 630 consecutive patients, 6 (1.0%) underwent redo TAVI for TAV-SVD (689-1,932 days after the first TAVI). The first TAV were 23-mm balloon-expandable valves (BEV, n=5) and a 26-mm self-expandable valve (SEV, n=1). All patients underwent multidetector computed tomography (MDCT) before redo TAVI, which showed first-TAV under-expansion (range, 19.1-21.0 mm) compared with the label size. Two BEV and 4 SEV were successfully implanted as second TAV, without moderate/severe regurgitation or 30-day mortality. One of 2 patients with a BEV-inside-BEV implantation had a high transvalvular mean pressure gradient post-procedurally (34 mmHg) and required surgical valve replacement 248 days after the redo TAVI. This, however, was unnoted in patients with SEV implantation during redo TAVI. Planned coronary artery bypass grafting was concomitantly performed in 1 patient with a small sino-tubular junction and SEV-inside-SEV implantation because of the risk of coronary malperfusion caused by the first TAV leaflets. Five of the 6 patients survived during the follow-up period (range, 285-1,503 days). Conclusions: Redo TAVI for TAV-SVD appears safe and feasible, while specific strategies based on MDCT and device selection seem important for better outcomes.

14.
Acta Otolaryngol ; 136(4): 409-13, 2016.
Article in English | MEDLINE | ID: mdl-26824787

ABSTRACT

Conclusion These findings suggest that low dose irradiation with 310 nm NB-UVB specifically suppressed the up-regulation of H1R gene expression without inducing apoptosis and that UVB of shorter or longer wavelength than 310 nm NB-UVB had no such effects. Objective To develop a narrowband-ultraviolet B(NB-UVB) phototherapy for allergic rhinitis, this study investigated the effects of irradiation with NB-UVB at wavelength of 310 nm on phorbol-12-myristate-13-acetate (PMA)-induced up-regulation of histamine H1 receptor (H1R) mRNA in HeLa cells. Methods The mRNA levels of H1R in HeLa cells were measured using real-time RT-PCR. Apoptosis were evaluated with DNA fragmentation assay. Results PMA induced a significant increase in H1R mRNA expression in HeLa cells. Irradiation with 305 nm UVB and 310 nm NB-UVB, but not with 315 nm UVB at doses of 200 and 300 mJ/cm(2) significantly suppressed PMA-induced up-regulation of H1R mRNA. At a dose of 200 mJ/cm(2), irradiation with 305 nm UVB, but not with 310 nm NB-UVB, induced apoptosis, although exposure of the cells to both 305 and 310 nm UVB induced apoptosis at a dose of 300 mJ/cm(2) after PMA treatment in HeLa cells. Conversely, irradiation with 315 nm UVB at doses of 200 and 300 mJ/cm(2) did not induce apoptosis.


Subject(s)
Epithelial Cells/radiation effects , Receptors, Histamine H1/metabolism , Rhinitis, Allergic/radiotherapy , Ultraviolet Therapy , Epithelial Cells/metabolism , HeLa Cells , Humans , Phorbol Esters
15.
Cardiovasc Intervent Radiol ; 37(5): 1312-20, 2014 Oct.
Article in English | MEDLINE | ID: mdl-24352861

ABSTRACT

PURPOSE: To determine risk factors for systemic air embolism by percutaneous computed tomography (CT)-guided lung biopsy. METHODS: This case-control study used data from 2216 percutaneous lung biopsy procedures performed over 11 years at 12 institutions in Japan. Systemic air embolism was identified by retrospective review of CT images obtained during and immediately after the procedures. To fulfill our objective, multiple variables were compared between cases and controls with univariate analyses by using Student's t test and Fisher's exact test for numerical and categorical values, respectively. Multivariate logistic regression analysis was then performed using selected variables. RESULTS: Ten cases of systemic air embolism and 2,206 controls were identified. Univariate analyses showed that the lesions in the lower lobe (P = 0.025) and occurrence of parenchymal hemorrhage (P = 0.019) were significant risk factors. Multivariate analysis showed that the use of a larger biopsy needle was a significant risk factor (P = 0.014). CONCLUSION: Parenchymal hemorrhage during the procedure, lesions in the lower lobe, and the use of larger biopsy needles may be risk factors for systemic air embolism by percutaneous CT-guided lung biopsy. Our findings may provide clues toward minimizing the risk of this complication.


Subject(s)
Embolism, Air/diagnostic imaging , Radiography, Interventional/methods , Tomography, X-Ray Computed/methods , Aged , Aged, 80 and over , Case-Control Studies , Embolism, Air/etiology , Female , Humans , Image-Guided Biopsy/adverse effects , Image-Guided Biopsy/methods , Lung/diagnostic imaging , Lung/pathology , Male , Middle Aged , Retrospective Studies , Risk Factors
16.
Acta Med Okayama ; 65(5): 287-97, 2011 Oct.
Article in English | MEDLINE | ID: mdl-22037265

ABSTRACT

The application of radiofrequency ablation for the treatment of lung cancer by our group at Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences began in June 2001, and in the present report, we review our 10-year experience with this treatment modality at Okayama University Hospital. The local efficacy of radiofrequency ablation for the treatment of lung cancer depends on tumor size and the type of electrode used, but not on tumor type. An important factor for the prevention of local failure may be the acquisition of an adequate ablative margin. The combination of embolization and radiation therapy enhances the local efficacy. Local failure may be salvaged by repeating the radiofrequency ablation, particularly in small tumors. Survival rates after radiofrequency ablation are quite promising for patients with clinical stage I non-small cell lung cancer and pulmonary metastasis from colorectal cancer, hepatocellular carcinoma, and renal cell carcinoma. The complications caused by radiofrequency ablation can be treated conservatively in the majority of cases. However, attention should be paid to rare but serious complications. This review shows that radiofrequency ablation is a promising treatment for patients with lung cancer.


Subject(s)
Catheter Ablation , Lung Neoplasms/surgery , Algorithms , Catheter Ablation/adverse effects , Catheter Ablation/methods , Disease Progression , Humans , Lung Neoplasms/pathology , Survival Rate , Tomography, X-Ray Computed
17.
Acta Med Okayama ; 65(5): 347-51, 2011 Oct.
Article in English | MEDLINE | ID: mdl-22037273

ABSTRACT

We report herein the case of a 76-year-old woman with autosomal dominant polycystic kidney disease (ADPKD) and chronic renal failure resulting in intractable abdominal distension and anorexia. Computed tomography (CT) showed enlarged and cystic kidneys. We performed transcatheter arterial embolization (TAE) for renal arteries with ethanol. Absolute ethanol with iodinated contrast medium or Lipiodol was delivered into both renal arteries. The patient's low-grade fever subsided in 5 days, and no other complication occurred. The sensation of abdominal distension diminished approximately 1 month after embolization. A progressive decrease in kidney size was observed soon after embolization. The percentage of the decrement of kidney size was approximately 50% after 17 months. These results indicate that renal TAE with ethanol is a safe, cost-effective, and minimally invasive technique to reduce kidney size in symptomatic ADPKD patients.


Subject(s)
Embolization, Therapeutic/methods , Polycystic Kidney, Autosomal Dominant/pathology , Polycystic Kidney, Autosomal Dominant/surgery , Aged , Angiography , Contrast Media/metabolism , Ethanol/metabolism , Female , Humans , Kidney/pathology , Kidney/surgery , Kidney Failure, Chronic/etiology , Kidney Failure, Chronic/surgery , Minimally Invasive Surgical Procedures/economics , Minimally Invasive Surgical Procedures/instrumentation , Minimally Invasive Surgical Procedures/methods , Polycystic Kidney, Autosomal Dominant/complications , Tomography, X-Ray Computed , Treatment Outcome
18.
Eur Radiol ; 19(10): 2474-80, 2009 Oct.
Article in English | MEDLINE | ID: mdl-19440712

ABSTRACT

The aim of this study was to retrospectively evaluate the safety and efficacy of polidocanol sclerotherapy in pain relief for painful venous malformations (VMs). Thirty-one patients with painful VMs underwent polidocanol sclerotherapy. Pain intensity was assessed with an 11-point verbal numerical rating scale. Sclerotherapy was technically successful in 58 (98.3%) of 59 sessions. Twenty-six (89.7%) out of 29 patients experienced an improvement in pain after sclerotherapy at follow-up, a mean of 46 months after treatment. The mean pain score improved from 6.6 + or - 2.5 before treatment to 2.4 + or - 2.9 after treatment (P <.001). The factors that significantly influenced the therapeutic effect were size of lesion (P = .008), margin of lesion (P = .006), and stasis of sclerosant (P = .032). Adverse events included hypotension and bradycardia during the procedure. No major complication occurred. Polidocanol sclerotherapy is safe and most efficacious in providing pain relief for patients with small VMs (equal to or less than 10 cm in diameter), VMs with a well-defined margin, and VMs with good stasis of sclerosant during sclerotherapy.


Subject(s)
Pain Measurement/drug effects , Pain/etiology , Pain/prevention & control , Polyethylene Glycols/therapeutic use , Sclerotherapy/methods , Veins/abnormalities , Veins/drug effects , Adolescent , Adult , Aged , Child , Child, Preschool , Female , Humans , Male , Middle Aged , Polidocanol , Polyethylene Glycols/adverse effects , Retrospective Studies , Sclerosing Solutions/adverse effects , Sclerosing Solutions/therapeutic use , Treatment Outcome , Young Adult
19.
Cardiovasc Intervent Radiol ; 31(3): 581-6, 2008.
Article in English | MEDLINE | ID: mdl-18197451

ABSTRACT

The purpose of this study was to investigate the relationship between pleural temperature and pneumothorax or pleural effusion after radiofrequency (RF) ablation of lung tumors. The pleural temperature was measured immediately outside the lung surface nearest to the tumor with a fiber-type thermocouple during 25 ablation procedures for 34 tumors in 22 patients. The procedures were divided into two groups depending on the highest pleural temperature: P-group I and P-group II, with highest pleural temperatures of <40 degrees C and >/=40 degrees C, respectively. The incidence of pneumothorax or pleural effusion was compared between the groups. Multiple variables were compared between the groups to determine the factors that affect the pleural temperature. The overall incidence of pneumothorax and pleural effusion was 56% (14/25) and 20% (5/25), respectively. Temperature data in five ablation procedures were excluded from the analyses because these were affected by the pneumothorax. P-group I and P-group II comprised 10 procedures and 10 procedures, respectively. The incidence of pleural effusion was significantly higher in P-group II (4/10) than in P-group I (0/10) (p = 0.043). However, the incidence of pneumothorax did not differ significantly (p = 0.50) between P-group I (4/10) and P-group II (5/10). Factors significantly affecting the pleural temperature were distance between the electrode and the pleura (p < 0.001) and length of the lung parenchyma between the electrode and the pleura (p < 0.001). We conclude that higher pleural temperature appeared to be associated with the occurrence of pleural effusion and not with that of pneumothorax.


Subject(s)
Catheter Ablation/adverse effects , Pleura/physiology , Pleural Effusion/epidemiology , Pneumothorax/epidemiology , Temperature , Aged , Aged, 80 and over , Catheter Ablation/instrumentation , Catheter Ablation/methods , Cohort Studies , Female , Humans , Incidence , Intraoperative Complications/diagnosis , Intraoperative Complications/epidemiology , Lung Neoplasms/mortality , Lung Neoplasms/pathology , Lung Neoplasms/surgery , Male , Middle Aged , Monitoring, Intraoperative/methods , Pleural Effusion/etiology , Pneumothorax/etiology , Probability , Prognosis , Risk Assessment , Statistics, Nonparametric , Survival Rate , Treatment Outcome
20.
Acta Med Okayama ; 61(3): 177-80, 2007 Jun.
Article in English | MEDLINE | ID: mdl-17593954

ABSTRACT

We report the clinical experience of radiofrequency ablation followed by radiation therapy for large primary lung tumors. Two patients with large primary lung tumors were treated with combined radiofrequency ablation and radiation therapy, and good local control was observed. Combined radiofrequency ablation and radiation therapy that involves minimally invasive techniques appears to be promising for the treatment of large lung tumors.


Subject(s)
Carcinoma, Non-Small-Cell Lung/radiotherapy , Carcinoma, Non-Small-Cell Lung/surgery , Catheter Ablation , Lung Neoplasms/radiotherapy , Lung Neoplasms/surgery , Aged, 80 and over , Carcinoma, Non-Small-Cell Lung/diagnostic imaging , Combined Modality Therapy , Follow-Up Studies , Humans , Lung Neoplasms/diagnostic imaging , Male , Middle Aged , Radiography , Reoperation , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...