Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Rev Lett ; 118(15): 151102, 2017 Apr 14.
Article in English | MEDLINE | ID: mdl-28452534

ABSTRACT

Interferometric gravitational wave detectors operate with high optical power in their arms in order to achieve high shot-noise limited strain sensitivity. A significant limitation to increasing the optical power is the phenomenon of three-mode parametric instabilities, in which the laser field in the arm cavities is scattered into higher-order optical modes by acoustic modes of the cavity mirrors. The optical modes can further drive the acoustic modes via radiation pressure, potentially producing an exponential buildup. One proposed technique to stabilize parametric instability is active damping of acoustic modes. We report here the first demonstration of damping a parametrically unstable mode using active feedback forces on the cavity mirror. A 15 538 Hz mode that grew exponentially with a time constant of 182 sec was damped using electrostatic actuation, with a resulting decay time constant of 23 sec. An average control force of 0.03 nN was required to maintain the acoustic mode at its minimum amplitude.

2.
Rev Sci Instrum ; 87(1): 014502, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26827334

ABSTRACT

The advanced LIGO gravitational wave detectors are nearing their design sensitivity and should begin taking meaningful astrophysical data in the fall of 2015. These resonant optical interferometers will have unprecedented sensitivity to the strains caused by passing gravitational waves. The input optics play a significant part in allowing these devices to reach such sensitivities. Residing between the pre-stabilized laser and the main interferometer, the input optics subsystem is tasked with preparing the laser beam for interferometry at the sub-attometer level while operating at continuous wave input power levels ranging from 100 mW to 150 W. These extreme operating conditions required every major component to be custom designed. These designs draw heavily on the experience and understanding gained during the operation of Initial LIGO and Enhanced LIGO. In this article, we report on how the components of the input optics were designed to meet their stringent requirements and present measurements showing how well they have lived up to their design.

3.
Phys Rev Lett ; 114(16): 161102, 2015 Apr 24.
Article in English | MEDLINE | ID: mdl-25955042

ABSTRACT

Parametric instabilities have long been studied as a potentially limiting effect in high-power interferometric gravitational wave detectors. Until now, however, these instabilities have never been observed in a kilometer-scale interferometer. In this Letter, we describe the first observation of parametric instability in a gravitational wave detector, and the means by which it has been removed as a barrier to progress.

4.
Opt Lett ; 37(23): 4952-4, 2012 Dec 01.
Article in English | MEDLINE | ID: mdl-23202101

ABSTRACT

We present the first demonstration of real-time closed-loop control and deterministic tuning of an independently suspended Fabry-Perot optical cavity using digitally enhanced heterodyne interferometry, realizing a peak sensitivity of ~10 pm/√Hz over the 10-1000 Hz frequency band. The methods presented are readily extensible to multiple coupled cavities. As such, we anticipate that refinements of this technique may find application in future interferometric gravitational-wave detectors.

5.
Opt Express ; 20(1): 81-9, 2012 Jan 02.
Article in English | MEDLINE | ID: mdl-22274331

ABSTRACT

Residual motion of the arm cavity mirrors is expected to prove one of the principal impediments to systematic lock acquisition in advanced gravitational-wave interferometers. We present a technique which overcomes this problem by employing auxiliary lasers at twice the fundamental measurement frequency to pre-stabilise the arm cavities' lengths. Applying this approach, we reduce the apparent length noise of a 1.3 m long, independently suspended Fabry-Perot cavity to 30 pm rms and successfully transfer longitudinal control of the system from the auxiliary laser to the measurement laser.


Subject(s)
Artifacts , Gravitation , Interferometry/instrumentation , Lasers , Transducers , Equipment Design , Equipment Failure Analysis
6.
Rev Sci Instrum ; 82(12): 125108, 2011 Dec.
Article in English | MEDLINE | ID: mdl-22225250

ABSTRACT

We describe the design of a small optic suspension system, referred to as the tip-tilt mirror suspension, used to isolate selected small optics for the interferometer sensing and control beams in the advanced LIGO gravitational wave detectors. The suspended optics are isolated in all 6 degrees of freedom, with eigenmode frequencies between 1.3 Hz and 10 Hz. The suspended optic has voice-coil actuators which provide an angular range of ±4 mrad in the pitch and yaw degrees of freedom.

7.
Opt Express ; 18(5): 5213-20, 2010 Mar 01.
Article in English | MEDLINE | ID: mdl-20389534

ABSTRACT

We present a technique for the stable transfer of an optical frequency reference over a kilometer-scale optical fiber link. This technique implements phase measurements and laser feedback to cancel out the phase fluctuations that are introduced to an optical frequency standard as it passes through the fiber. We also present results for a bench top experiment, developed for the Advanced LIGO lock acquisition system, where this technique is implemented to phase-lock two Nd:YAG lasers, through a 4.6 km optical fiber. The resulting differential optical frequency noise reaches a level as low as 0.5 mHz/ radical Hz for Fourier frequencies between 5 Hz and 20 Hz, which is equal to a fractional frequency stability of 1.7 x 10(-18)/ radical Hz.

SELECTION OF CITATIONS
SEARCH DETAIL
...