Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-38757702

ABSTRACT

PURPOSE: This study aimed to assess the outcomes of percutaneous cryoablation (PCA) for renal cell carcinomas (RCCs) contacting critical organs without intervening fat tissue. MATERIAL AND METHODS: Twenty-three patients with 24 RCCs (mean size, 28.8 mm) contacting critical organs on preprocedural images were included. The organ displacement techniques, technical success, efficacy, and adverse events per Clavien-Dindo classification were retrospectively reviewed. RESULTS: The organs contacting the RCCs included the colon (n = 16), pancreas (n = 3), duodenum (n = 3), small intestine (n = 1), and stomach (n = 1). In all procedures, hydrodissection was conducted, and probe traction was additionally utilized in one to displace organs. Two procedures were terminated with an insufficient ice-ball margin (<6 mm) due to recurring proximity of the colon or thermal sink effect by renal hilar vessels, yielding a technical success rate of 91.6% (22/24). No severe adverse events were noted. All patients were alive without any metastases during a median follow-up of 34.4 months. The primary and secondary technical efficacy rates were 91.6% (22/24) and 95.8% (23/24) of tumors, respectively. CONCLUSION: PCA can be a valid option for RCCs contacting critical organs with a good safety profile and sufficient technical efficacy.

3.
Jpn J Radiol ; 42(6): 648-655, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38388790

ABSTRACT

PURPOSE: To retrospectively evaluate the depiction rate of feeding arteries in biopsy-proven clear cell renal cell carcinoma (CCRCC) on four-dimensional computed tomography angiography (4D-CTA) images. MATERIALS AND METHODS: This study included 22 patients with 22 CCRCC and 30 feeding arteries treated with transcatheter renal artery embolization. The depiction rate of the feeding arteries on preprocedural 4D-CTA was evaluated. Images were acquired by 320-row multi-detector computed tomography (CT) 15‒36 s after starting to inject a contrast agent (600 mg/kg iodine) intravenously into patients at 2.1 s intervals (11 phases). Two board-certified radiologists retrospectively assessed the feeder depiction rate in all 11 phases with reference to the procedural images as the gold standard. Discrepancies were resolved by consultation with a third radiologist. RESULTS: Among the feeders, 11 (36.7%) were segmental or lobar, and 19 (63.3%) were interlobar or arcuate arteries. The feeder depiction rate was the highest (25 [83.3%] of 30) in the 5th phase (delay, 23.4 s) where the gap in contrast enhancement between the renal artery and cortex was the largest. This was followed by the 6th (23 [76.7%] of 30), 4th (22 [73.3%] of 30]), and 7th (21 [70.0%] of 30) phases. The overall rate of depicting feeding arteries in the 11 phases of 4D-CTA was 28 (93.3%) of 30. CONCLUSIONS: The depiction rate of CCRCC feeding arteries including lobar or smaller artery branches by 4D-CTA was favorable. The feeding arteries were optimally visualized during the phase with the largest contrast gap between the renal artery and cortex.


Subject(s)
Carcinoma, Renal Cell , Computed Tomography Angiography , Contrast Media , Four-Dimensional Computed Tomography , Kidney Neoplasms , Humans , Carcinoma, Renal Cell/diagnostic imaging , Carcinoma, Renal Cell/blood supply , Kidney Neoplasms/diagnostic imaging , Kidney Neoplasms/blood supply , Female , Male , Retrospective Studies , Middle Aged , Aged , Computed Tomography Angiography/methods , Aged, 80 and over , Four-Dimensional Computed Tomography/methods , Adult , Renal Artery/diagnostic imaging , Kidney/diagnostic imaging , Kidney/blood supply , Embolization, Therapeutic/methods
SELECTION OF CITATIONS
SEARCH DETAIL