Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Biomech (Bristol, Avon) ; 99: 105768, 2022 10.
Article in English | MEDLINE | ID: mdl-36150287

ABSTRACT

BACKGROUND: Due to high stiffness, metal fixation plates are prone to stress shielding of the peri-prosthetic bones, leading to bone loss. Therefore, it has become important to design implants with reduced rigidity but increased load-carrying capacity. Considering the uncertainties in the parameters affecting the implant-bone structure is critical in making more reliable implant designs. In this study, a Response Surface Method based Reliability-based Topology Optimization approach was proposed to design a fixation plate for humerus fracture having less stiffness than the conventional plate. METHODS: The design of the fixation plate was described as an Reliability-based Topology Optimization problem in which the probabilistic constraint was replaced with a meta-model generated using the Kriging method. The artificial humerus bone model was scanned, and the 3D simulation model was used in the finite element analysis required in the solution. The optimum plate was manufactured using Selective Laser Melting. Both designs were experimentally compared in terms of rigidity. FINDINGS: The volume of the conventional plate was reduced from 2512.5 mm3 to 1667.3 mm3; nevertheless, the optimum plate had almost one-third less rigidity than the conventional plate. The probability of failure of the conventional plate was computed as 0.994. However, this value was almost half for the optimum fixation plate. Interpretation The studies showed that the new fixation plate design was less rigid but more reliable than the conventional one. The computation time required to have the optimum plate was reduced by one-tenth by applying the Response Surface Method for the Reliability-based Topology Optimization problem.


Subject(s)
Bone Plates , Fracture Fixation, Internal , Biomechanical Phenomena , Finite Element Analysis , Fracture Fixation, Internal/methods , Humans , Humerus/surgery , Reproducibility of Results , Stress, Mechanical
2.
Biomed Tech (Berl) ; 67(4): 295-305, 2022 Aug 26.
Article in English | MEDLINE | ID: mdl-35727116

ABSTRACT

In order to prevent failure as well as ensure comfort, patient-specific modelling for prostheses has been gaining interest. However, deterministic analyses have been widely used in the design process without considering any variation/uncertainties related to the design parameters of such prostheses. Therefore, this study aims to compare the performance of patient-specific anatomic Total Knee Arthroplasty (TKA) with off-the-shelf TKA. In the patient-specific model, the femoral condyle curves were considered in the femoral component's inner and outer surface design. The tibial component was designed to completely cover the tibia cutting surface. In vitro experiments were conducted to compare these two models in terms of loosening of the components. A probabilistic approach based on the finite element method was also used to compute the probability of failure of both models. According to the deterministic analysis results, 103.10 and 21.67 MPa von Mises stress values were obtained for the femoral component and cement in the anatomical model, while these values were 175.86 and 25.76 MPa, respectively, for the conventional model. In order to predict loosening damage due to local osteolysis or stress shield, it was determined that the deformation values in the examined cement structures were 15% lower in the anatomical model. According to probabilistic analysis results, it was observed that the probability of encountering an extreme value for the anatomical model is far less than that of the conventional model. This indicates that the anatomical model is safer than the conventional model, considering the failure scenarios in this study.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Arthroplasty, Replacement, Knee/methods , Finite Element Analysis , Humans , In Vitro Techniques , Knee Joint/surgery , Prosthesis Failure
3.
Med Eng Phys ; 92: 18-24, 2021 06.
Article in English | MEDLINE | ID: mdl-34167707

ABSTRACT

Fixation plates are used to accelerate the biological healing process in the damaged area by providing mechanical stabilization for fractured bones. However, they may cause mechanical and biological complications such as aseptic loosening, stress shielding effect and necrosis during the treatment process. The aim of this study, therefore, was to reduce mechanical and biological complications observed in conventional plate models. For this purpose, an optimum plate geometry was obtained using the finite element based topology optimization approach. An optimum and functionally graded porous model were obtained for the plates used for transverse fractures of diaphysis in long bones. This model was combined with a functional graded porous cage structure, and thus a new generation porous implant model was proposed for fixation plates. In order to determine the performance of the optimum plate model, it was produced by additive manufacturing. Three models; i.e. conventional, optimum and porous fixation plates were statically tested, and they were compared experimentally and numerically using the finite element analysis (FEA). The porous model can be considered as the most suitable option since it requires less invasive inputs, and might lead minimum necrosis formation due to having lesser contact surface with the bone.


Subject(s)
Bone Plates , Fractures, Bone , Biomechanical Phenomena , Finite Element Analysis , Humans , Porosity
SELECTION OF CITATIONS
SEARCH DETAIL
...