Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 133
Filter
1.
Appl Radiat Isot ; 209: 111299, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38613949

ABSTRACT

Glass dosimeters are very useful and convenient detection elements in radiation dosimetry. In this study, this glass dosimeter was applied to a BNCT treatment field. Boron Neutron Capture Therapy (BNCT) is a next-generation radiation therapy that can selectively kill only cancer cells. In the BNCT treatment field, both neutrons and secondary gamma-rays are generated. In other words, it is a mixed radiation field of neutrons and gamma-rays. We thus proposed a novel method to measure only gamma-ray dose in the mixed field using two RPLGD (Radiophoto-luminescence Glass Dosimeter) and two sensitivity control filters in order to control the dose response of the filtered RPLGD to be proportional to the air kerma coefficients, even if the gamma-ray energy spectrum is unknown. As the filter material iron was selected, and it was finally confirmed that reproduction of the air kerma coefficients was excellent within an error of 5.3% in the entire energy range up to 10 MeV. In order to validate this method, irradiation experiments were carried out using standard gamma-ray sources. As the result, the measured doses were in acceptably good agreement with the theoretical calculation results by PHITS. In the irradiation experiment with a volume source in a nuclear fuel storage room, the measured dose rates showed larger compared with survey meter values. In conclusion, the results of the standard sources showed the feasibility of this method, however for the volume source the dependence of the gamma-ray incident angle on the dosimeter was found to be not neglected. In the next step, it will be necessary to design a thinner filter in order to suppress the effect of the incident angle.

3.
Sci Rep ; 13(1): 22883, 2023 12 18.
Article in English | MEDLINE | ID: mdl-38129553

ABSTRACT

Boron neutron capture therapy (BNCT) is a high-dose-intensive radiation therapy that has gained popularity due to advancements in accelerator neutron sources. To determine the dose for BNCT, it is necessary to know the difficult-to-determine boron concentration and neutron fluence. To estimate this dose, we propose a method of measuring the prompt γ-rays (PGs) from the boron neutron capture reaction (BNCR) using a Compton camera. We performed a fundamental experiment to verify basic imaging performance and the ability to discern the PGs from 511 keV annihilation γ-rays. A Si/CdTe Compton camera was used to image the BNCR and showed an energy peak of 478 keV PGs, separate from the annihilation γ-ray peak. The Compton camera could visualize the boron target with low neutron intensity and high boron concentration. This study experimentally confirms the ability of Si/CdTe Compton cameras to image BNCRs.


Subject(s)
Boron Neutron Capture Therapy , Cadmium Compounds , Quantum Dots , Boron Neutron Capture Therapy/methods , Boron/therapeutic use , Tellurium , Neutrons
4.
Appl Radiat Isot ; 199: 110897, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37352647

ABSTRACT

Boron Neutron Capture Therapy (BNCT) is a cell-selective radiotherapy using a neutron capture reaction of 10B. In recent years, Accelerator Based Neutron Sources (ABNS) are under development instead of nuclear reactors for the next-generation neutron irradiation system for BNCT. However, ABNS as well as nuclear reactor usually generates unavoidable secondary gamma-rays by neutron-nuclear reactions such as capture reaction. In this research, we aimed to develop a separate measurement method of only gamma-rays in a mixed field of neutrons and gamma-rays using a fluorescent glass dosimeter (RPLGD), because most dosimeters have sensitivity to both radiation types. For this purpose, we proposed a lead filter method using two RPLGDs and lead filters. However, this method has a problem that the sensitivity to low energy gamma-rays (∼100 keV) is very small. In order to improve the sensitivity to low energy gamma-rays, we devised a method using a specially shaped lead filter. From theoretical calculations, we have shown that it was possible to estimate the air dose rate of the field where the gamma-ray energy spectrum shape was known for energies up to 10 MeV. In addition, we produced the specially shaped lead filter and experimentally confirmed the validity of the lead filter method using several gamma-ray standard sources and by measurements in a nuclear fuel storage room.

5.
Rev Sci Instrum ; 90(4): 043503, 2019 Apr.
Article in English | MEDLINE | ID: mdl-31043024

ABSTRACT

Time-resolved triton burnup studies have been carried out to estimate the behavior of alpha particles in DD fusion experimental devices. In those studies, 14 MeV neutrons emitted through DT reactions in DD plasmas should be measured selectively in the backgrounds of DD neutrons and gamma rays. For this purpose, a scintillating-fiber (Sci-Fi) based fast-neutron detector has been adapted because of its advantages such as fast response, design flexibility in detection efficiency by changing the number of Sci-Fi, and discrimination property against 2.4 MeV neutrons produced through DD reactions and gamma rays. However, its length had conventionally been set to around 10 cm without an optimization study of its design parameters to meet the requirements as 14 MeV neutron detector. In the present study, we tested three types of Sci-Fi detectors with three different lengths and compared with the simulated results of energy deposition, through which we tried to understand the phenomena in the detection process of fast neutrons. From the results, it has been shown that, due to the self-shielding of neutrons by Sci-Fi and the attenuation of scintillation photons during the transmission process to the photomultiplier tube, the optimal length of Sci-Fi is concluded to be about 6 cm.

7.
Rev Sci Instrum ; 89(10): 10I118, 2018 Oct.
Article in English | MEDLINE | ID: mdl-30399758

ABSTRACT

In time-resolved measurement for triton burnup in Korea Superconducting Tokamak Advanced Research (KSTAR) deuterium plasmas, an NE213 liquid scintillation detector was installed and operated during the 2017 KSTAR campaign. The detector is composed of an NE213 scintillator (50 mm in diameter and 10 mm in thickness) and a photomultiplier tube (PMT). The PMT anode signal was processed under a data acquisition system which contains a field programmable gate array circuit and pulse processing software that is capable of discriminating gamma-ray and neutron pulse signals. In order to determine an appropriate threshold level for the 14 MeV neutron signal resulting from triton burnup, the NE213 scintillation detector was calibrated by using d-d and d-t neutron generators at the National Fusion Research Institute and Intense 14 MeV Neutron Source Facility, OKTAVIAN, Osaka University, Japan. The detector was installed on KSTAR with a 10 mm thick soft-iron stray magnetic field shield and a radiation shield which consists of 100 mm thick lead blocks and 200 mm thick borated polyethylene blocks. A discrimination range for d-t neutron was determined based on test results from neutron generators and KSTAR. Data points selected from the discrimination range were consistent with the classical triton confinement characteristics. In conclusion, under condition of an input counting rate of 1.9 × 105 counts per second (CPS), the detector is able to measure triton burnup signals up to 500 CPS for various plasma parameters.

8.
Appl Radiat Isot ; 106: 72-4, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26275798

ABSTRACT

Mock-up experiment for development of accelerator based neutron source for Osaka University BNCT project was carried out at Birmingham University, UK. In this paper, spatial distribution of neutron flux intensity was evaluated by foil activation method. Validity of the design code system was confirmed by comparing measured gold foil activities with calculations. As a result, it was found that the epi-thermal neutron beam was well collimated by our neutron moderator assembly. Also, the design accuracy was evaluated to have less than 20% error.


Subject(s)
Boron Neutron Capture Therapy , Gold/chemistry , Neutrons
9.
Appl Radiat Isot ; 106: 92-4, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26253274

ABSTRACT

Liquid lithium (Li) is a candidate material for a target of intense neutron source, heat transfer medium in space engines and charges stripper. For a medical application of BNCT, epithermal neutrons with least energetic neutrons and γ-ray are required so as to avoid unnecessary doses to a patient. This is enabled by lithium target irradiated by protons at 2.5 MeV range, with utilizing the threshold reaction of (7)Li(p,n)(7)Be at 1.88 MeV. In the system, protons at 2.5 MeV penetrate into Li layer by 0.25 mm with dissipating heat load near the surface. To handle it, thin film flow of high velocity is important for stable operation. For the proton accelerator, electrostatic type of the Schnkel or the tandem is planned to be employed. Neutrons generated at 0.6 MeV are gently moderated to epithermal energy while suppressing accompanying γ-ray minimum by the dedicated moderator assembly.


Subject(s)
Boron Neutron Capture Therapy , Lithium/chemistry , Neutrons
10.
Appl Radiat Isot ; 106: 41-4, 2015 Dec.
Article in English | MEDLINE | ID: mdl-26297075

ABSTRACT

Neutrons generated by accelerators have various energy spectra. However, only limited methods are available to measure the whole neutron energy spectrum, especially when including the epithermal region that is normally used in BNCT. In the present study, we carried out the design study on a new neutron spectrometer that can measure such a neutron spectrum more accurately, precisely and with higher energy resolution, using an unfolding technique and a liquid moderator.


Subject(s)
Boron Neutron Capture Therapy , Feasibility Studies
11.
Nature ; 515(7525): 104-7, 2014 Nov 06.
Article in English | MEDLINE | ID: mdl-25373680

ABSTRACT

The abundance of chlorine in the Earth's atmosphere increased considerably during the 1970s to 1990s, following large emissions of anthropogenic long-lived chlorine-containing source gases, notably the chlorofluorocarbons. The chemical inertness of chlorofluorocarbons allows their transport and mixing throughout the troposphere on a global scale, before they reach the stratosphere where they release chlorine atoms that cause ozone depletion. The large ozone loss over Antarctica was the key observation that stimulated the definition and signing in 1987 of the Montreal Protocol, an international treaty establishing a schedule to reduce the production of the major chlorine- and bromine-containing halocarbons. Owing to its implementation, the near-surface total chlorine concentration showed a maximum in 1993, followed by a decrease of half a per cent to one per cent per year, in line with expectations. Remote-sensing data have revealed a peak in stratospheric chlorine after 1996, then a decrease of close to one per cent per year, in agreement with the surface observations of the chlorine source gases and model calculations. Here we present ground-based and satellite data that show a recent and significant increase, at the 2σ level, in hydrogen chloride (HCl), the main stratospheric chlorine reservoir, starting around 2007 in the lower stratosphere of the Northern Hemisphere, in contrast with the ongoing monotonic decrease of near-surface source gases. Using model simulations, we attribute this trend anomaly to a slowdown in the Northern Hemisphere atmospheric circulation, occurring over several consecutive years, transporting more aged air to the lower stratosphere, and characterized by a larger relative conversion of source gases to HCl. This short-term dynamical variability will also affect other stratospheric tracers and needs to be accounted for when studying the evolution of the stratospheric ozone layer.

12.
Indian J Pharm Sci ; 75(4): 435-41, 2013 Jul.
Article in English | MEDLINE | ID: mdl-24302798

ABSTRACT

The aim of this study was to prepare an inclusion complex of acetaminophen and ß-cyclodextrin (molar ratio of 1:1). A jelly with inclusion complexes formed by kneading was prepared. The formation of inclusion complexes was assessed by powder X-ray diffraction patterns and Fourier transform-infrared spectroscopy. Jellies were prepared with xanthan gum, gelatin, and κ-carrageenan. The concentration of each jelling agent was 0.5, 1.0, and 1.5% w/v. Viscoelasticity and dissolution characteristics were determined and osmometry was performed. PGWater(™), a commercial jelly for fluid replacement, served as a reference for viscoelastic characteristics and dissolution. Powder X-ray diffraction measurement revealed a different diffraction pattern for the kneading than for acetaminophen and ß-cyclodextrin. Fourier transform-infrared spectroscopy revealed an absorption peak (at around 1655 cm(-1)) due to the carbonyl group and benzene ring (at around 1610 cm(-1)) of acetaminophen. In contrast, the kneaded mixture (1:1) had a shift in the absorption peak due to the carbonyl group (at around 1650 cm(-1)) in acetaminophen's molecular structure, and the formation of an inclusion complex was noted. The viscosity of xanthan gum-1.0, gelatin-1.5, and carrageenan-0.5 resembled the viscoelasticity of PGWater(™). The acetaminophen in gelatin-1.0 and carrageenan-0.5 had dissolution behavior similar to that of commercial acetaminophen preparations. The osmolality of jellies prepared in different concentrations ranged from about 20-50 mOsm/kg. Results suggested that carrageenan-0.5 could serve as a useful jelly vehicle for acetaminophen.

13.
Appl Radiat Isot ; 69(12): 1706-9, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21596575

ABSTRACT

As well known, it is difficult to know the exact treatment effect of boron neutron capture therapy (BNCT). It depends on the irradiation time, which is changed rather flexibly. At present, it is once fixed before BNCT. Then the actual stopping time is adjusted during BNCT by some means like activation foils. The author's group hence started development of a single-photon emission computed tomography (SPECT) system for BNCT to know the effect of BNCT in real time. By adopting a side surface (1×2 mm(2)) of a CdTe detector (1×2×20 mm(3)) as radiation entrance window, acceptable spatial resolution and high detection efficiency were simultaneously achieved. Also in about 30 min acceptable number of counts for 478 keV gamma-rays could be expected. In addition, employing a Schottky type detector the energy resolution could be improved. Discrimination of 478 keV and annihilation gamma-rays would thus be successfully made. In the next phase, it is planned to design and develop an array type detector to be implemented in the BNCT-SPECT system.


Subject(s)
Boron Neutron Capture Therapy/instrumentation , Cadmium Compounds , Tellurium , Tomography, Emission-Computed, Single-Photon/instrumentation
14.
Appl Radiat Isot ; 67(7-8 Suppl): S288-91, 2009 Jul.
Article in English | MEDLINE | ID: mdl-19376716

ABSTRACT

The development of new neutron sources for BNCT applications, based on particle accelerators is currently underway all over the world. Though nuclear reactors were used for a long time as the only neutron source available having the requested flux levels, the accelerator-based ones have recently been investigated on the other hand due to its easy-to-use and acceptable performances. However, when using an accelerator, various secondary particles would be emitted which forms a troublesome background. Moreover, the neutrons produced have usually an energy spectrum somewhat different from the requested one and thus should be largely moderated. An additional issue to be taken into account is the patient positioning, which should be close to the neutron source, in order to take advantage of a neutron flux level high enough to limit the BNCT treatment time within 1h. This implies that, inside a relatively narrow space, neutrons should be moderated, while unnecessary secondary particles should be shielded. Considering that a background-free neutron field from an accelerator-driven neutron source dedicated to BNCT application is generally difficult to be provided, the characterization of such a neutron field will have to be clearly assessed. In the present study, a low energy neutron spectrometer has been thus designed and is now being developed to measure the accelerator-based neutron source performance. The presently proposed spectrometer is based on a (3)He proportional counter, which is 50 cm long and 5 cm in diameter, with a gas pressure of 0.5 MPa. It is quite unique that the spectrometer is set up in parallel with the incident neutron beam and a reaction depth distribution is measured by it as a position sensitive detector. Recently, a prototype detector has been developed and the signal test is now underway. In this paper, the feature of the accelerator-based neutron sources is outlined and importance of neutron field characterization is discussed. And the developed new low energy neutron spectrometer for the characterization is detailed.


Subject(s)
Boron Neutron Capture Therapy/instrumentation , Neutrons/therapeutic use , Particle Accelerators , Radiometry/instrumentation , Equipment Design , Helium , Humans , Japan , Neoplasms/radiotherapy , Nuclear Reactors
15.
J Int Med Res ; 32(2): 141-8, 2004.
Article in English | MEDLINE | ID: mdl-15080017

ABSTRACT

Autoantibodies against heat shock protein 40 (HSP40) and their clinical significance in ulcerative colitis (UC) have not been evaluated before. Twenty-six tissue specimens of inflamed areas from patients with UC, 16 from patients with Crohn's disease (CD) and 16 endoscopically normal tissues were analysed for HSP40 expression. Sera from 47 patients with UC and 44 healthy volunteers were examined for the presence of autoantibodies against HSP40 by enzyme-linked immunosorbent assay test. Immunohistochemistry showed that 17 out of 26 specimens from UC patients, one specimen from a CD patient and one normal tissue specimen were positive for HSP40. Most HSP40-positive cells expressed CD68. Higher titres of anti-HSP40 autoantibodies were detected in sera from UC patients compared with healthy volunteers. In patients with inactive disease, those with proctitis or left-sided colitis had higher titres of anti-HSP40 autoantibodies than those with total colitis. Our study suggests that autoimmunity against HSP40 may have a beneficial effect in UC patients by limiting the extent of the disease.


Subject(s)
Autoantibodies/blood , Colitis, Ulcerative/immunology , Heat-Shock Proteins/immunology , Adolescent , Adult , Aged , Female , HSP40 Heat-Shock Proteins , Humans , Male , Middle Aged
16.
J Int Med Res ; 31(4): 247-52, 2003.
Article in English | MEDLINE | ID: mdl-12964499

ABSTRACT

The study aimed to determine the association between cytotoxin-associated gene product (CagA), serum gastrin and pepsinogen levels in Japanese children infected with Helicobacter pylori. Three hundred children were enrolled in the study. H. pylori infection was assessed using an enzyme-linked immunosorbent assay, and CagA status was assessed using immunoblotting. Serum gastrin and pepsinogen concentrations were measured by radioimmunoassay. H. pylori seroprevalence was 12.3% (37/300) and CagA status was identified in 28/37 H. pylori-seropositive children (75.7%). Serum pepsinogen I and II levels were significantly higher in CagA-seropositive than CagA-seronegative children with H. pylori infection. There was no significant relationship between CagA seropositivity and serum gastrin levels. In conclusion, CagA status has a significant impact on serum pepsinogen levels, possibly through enhanced gastric mucosal inflammation.


Subject(s)
Antigens, Bacterial/metabolism , Bacterial Proteins/metabolism , Gastrins/blood , Helicobacter Infections/blood , Pepsinogen A/blood , Pepsinogen C/blood , Adolescent , Antibodies/blood , Antigens, Bacterial/immunology , Bacterial Proteins/immunology , Child , Child, Preschool , Female , Humans , Japan , Male , Seroepidemiologic Studies
17.
J Int Med Res ; 31(4): 299-306, 2003.
Article in English | MEDLINE | ID: mdl-12964505

ABSTRACT

The microbicidal activities of superoxidized water (electrolysed strong acid water [ESAW] or electrolysed weak acid water [EWAW]), ozonated water, 0.05% chlorhexidine and 2% glutaraldehyde were tested against seven strains of clinical micro-organism isolates. Following incubation of bacterial suspensions in ESAW and EWAW for 10 s, the number of micro-organisms was reduced below the detection limit. The microbicidal activities of ESAW and EWAW were similar to that of glutaraldehyde, and superior to ozonated water and 0.05% chlorhexidine. The microbicidal activities of ESAW, EWAW and ozonated water were markedly diminished in the presence of albumin. Microbial contamination of upper gastrointestinal endoscopes was detected after 90 endoscopic procedures, but treatment of the endoscope with ESAW, EWAW or ozonated water eradicated the microbes. These results indicate that ESAW and EWAW are effective disinfectants after mechanical cleaning of upper gastrointestinal endoscopes, and can, therefore, be used in the endoscopy unit.


Subject(s)
Bacteria/drug effects , Disinfectants , Disinfection/methods , Endoscopes, Gastrointestinal/microbiology , Ozone/pharmacology , Superoxides/pharmacology , Water/chemistry , Acids/chemistry , Colony Count, Microbial , Equipment Contamination , Glutaral/metabolism , Humans , Ozone/chemistry , Superoxides/chemistry
18.
Aliment Pharmacol Ther ; 18(1): 101-7, 2003 Jul 01.
Article in English | MEDLINE | ID: mdl-12848631

ABSTRACT

BACKGROUND: There is currently no optimal second-line treatment after failure of Helicobacter pylori triple therapy. AIM: To determine effective salvage therapy after failure of lansoprazole-amoxicillin-clarithromycin. METHODS: After failure of lansoprazole-amoxicillin-clarithromycin 123 out-patients were randomized to receive either 2-week rabeprazole (20 mg b.d.) + amoxicillin (1000 mg b.d.) (RA group) or 1-week rabeprazole (10 mg b.d.) + amoxicillin (750 mg twice b.d.) + metronidazole (250 mg b.d.) (RAM group). Eradication was assessed by the 13C-urea breath test. We also evaluated cytochrome p450 (CYP) 2C19 genotype status, determined by polymerase chain reaction - restriction fragment length polymorphism, and susceptibility to clarithromycin and metronidazole. RESULTS: On an intention-to-treat basis, H. pylori infection cure was achieved in 37 of 63 (59%) patients in the RA group and in 49 of 60 (82%) patients in the RAM group. Per protocol-based eradication rates in the RA and RAM groups were 66% (37/56) and 88% (49/56), respectively. In both analytic sets there were significant differences between the treatment groups (P < 0.01 in each). Mild adverse events were observed in eight and five patients from the RA and RAM groups, respectively. Genetic predisposition of CYP2C19 and antibiotic resistance did not influence the treatment outcome either regimen. CONCLUSIONS: The rabeprazole + amoxicillin + metronidazole therapy yielded satisfactory results. In contrast, the cure rate in high-dose rabeprazole + amoxicillin was below an acceptable level.


Subject(s)
Amoxicillin/administration & dosage , Anti-Bacterial Agents/administration & dosage , Anti-Ulcer Agents/administration & dosage , Benzimidazoles/administration & dosage , Helicobacter Infections/drug therapy , Helicobacter pylori , Metronidazole/administration & dosage , 2-Pyridinylmethylsulfinylbenzimidazoles , Adult , Aged , Drug Resistance, Bacterial , Drug Therapy, Combination , Female , Humans , Male , Middle Aged , Omeprazole/analogs & derivatives , Penicillins/administration & dosage , Prospective Studies , Rabeprazole , Treatment Outcome
19.
J Int Med Res ; 31(2): 69-75, 2003.
Article in English | MEDLINE | ID: mdl-12760309

ABSTRACT

Interleukin 6 (IL-6) is a pleiotropic cytokine with many physiological functions. The present study was designed to determine the expression of IL-6 and its receptor (IL-6R) in human gastric and colorectal cancers. Nine gastric- and nine colorectal cancer cell lines were analysed. The IL-6 gene was expressed in two gastric cancer cell lines and one colorectal cancer cell line; however, most of the cancer cell lines studied expressed the IL-6R gene. The level of IL-6 secretion in the gastric cancer cell lines correlated with the level of soluble IL-6R secretion, and was significantly higher (< approximately 100 pg/ml) than the level of IL-6 secretion in the colorectal cancer cell lines (< approximately 50 pg/ml). These results suggest that IL-6 may act in a paracrine fashion rather than an autocrine fashion in these cell lines.


Subject(s)
Colorectal Neoplasms/metabolism , Gene Expression Regulation, Neoplastic , Interleukin-6/metabolism , Stomach Neoplasms/metabolism , Cell Line, Tumor , Colorectal Neoplasms/genetics , Humans , Stomach Neoplasms/genetics
20.
J Int Med Res ; 30(4): 413-21, 2002.
Article in English | MEDLINE | ID: mdl-12235924

ABSTRACT

The aim of the present study was to investigate whether CYP2C19 polymorphism status and gastric emptying are related to healing in patients with gastric ulcers. We studied the CYP2C19 status in seven patients with proton pump inhibitor (PPI)-resistant ulcers, 21 with PPI-sensitive ulcers and 46 healthy volunteers using polymerase chain reaction restriction fragment length polymorphism to detect CYP2C19m1 mutation in exon 5 and CYP2C19m2 mutation in exon 4. Gastric emptying was evaluated using the 13C-acetate breath test. The frequency of phenotypes, indicated by genotypes, did not differ significantly between the three patient groups. The peak time of 13C excretion in patients with PPI-resistant ulcers was significantly longer than that of patients with PPI-sensitive ulcers and healthy volunteers. Our results suggest that rate of gastric emptying, but not CYP2C19 polymorphism, is likely to be an important factor in the delayed healing of patients with PPI-resistant gastric ulcer.


Subject(s)
Aryl Hydrocarbon Hydroxylases/genetics , Gastric Emptying/physiology , Mixed Function Oxygenases/genetics , Omeprazole/analogs & derivatives , Proton Pump Inhibitors , Stomach Ulcer/genetics , 2-Pyridinylmethylsulfinylbenzimidazoles , Adult , Anti-Ulcer Agents/therapeutic use , Aryl Hydrocarbon Hydroxylases/physiology , Benzimidazoles/therapeutic use , Cytochrome P-450 CYP2C19 , Female , Gastric Emptying/genetics , Humans , Lansoprazole , Male , Middle Aged , Mixed Function Oxygenases/physiology , Omeprazole/therapeutic use , Polymorphism, Genetic/physiology , Rabeprazole , Stomach Ulcer/drug therapy , Stomach Ulcer/enzymology , Stomach Ulcer/physiopathology
SELECTION OF CITATIONS
SEARCH DETAIL
...