Eur Radiol ; 23(3): 623-31, 2013 Mar.
Article in English | MEDLINE | ID: mdl-22940731

ABSTRACT

OBJECTIVE: To survey procedures and protocols in paediatric computed tomography (CT) in 40 less resourced countries. METHODS: Under a project of the International Atomic Energy Agency, 146 CT facilities in 40 countries of Africa, Asia, Europe and Latin America responded to an electronic survey of CT technology, exposure parameters, CT protocols and doses. RESULTS: Modern MDCT systems are available in 77 % of the facilities surveyed with dedicated paediatric CT protocols available in 94 %. However, protocols for some age groups were unavailable in around 50 % of the facilities surveyed. Indication-based protocols were used in 57 % of facilities. Estimates of radiation dose using CTDI or DLP from standard CT protocols demonstrated wide variation up to a factor of 100. CTDI(vol) values for the head and chest were between two and five times those for an adult at some sites. Sedation and use of shielding were frequently reported; immobilisation was not. Records of exposure factors were kept at 49 % of sites. CONCLUSION: There is significant potential for improvement in CT practice and protocol use for children in less resourced countries. Dose estimates for young children varied widely. This survey provides critical baseline data for ongoing quality improvement efforts by the IAEA.


Subject(s)
Health Services Accessibility/statistics & numerical data , Pediatrics/statistics & numerical data , Practice Patterns, Physicians'/statistics & numerical data , Radiation Protection/statistics & numerical data , Tomography, X-Ray Computed/statistics & numerical data , Africa/epidemiology , Asia/epidemiology , Europe/epidemiology , Health Care Surveys , Humans , Latin America/epidemiology , Radiation Dosage
2.
Eur J Radiol ; 81(10): e982-9, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22835877

ABSTRACT

Recognizing the lack of information on image quality and patient doses in most countries in Asia, the International Atomic Energy Agency (IAEA) initiated a project to assess the status of imaging technology, practice in conventional radiography, mammography, computed tomography (CT) and interventional procedures, and to implement optimisation actions. A total of 20 countries participated. Obsolete practices of use of fluoroscopy for positioning, photofluorography, chest fluoroscopy and conventional tomography were reported by 4 out of 7 countries that provided this information. Low-kV technique for chest radiography is in use in participating countries for 20-85% of cases, and manual processing is in 5-85% of facilities in 5 countries. Instances of the use of adult CT protocol for children in three participating countries were observed in 10-40% of hospitals surveyed. After implementation of a Quality Control programme, the image quality in conventional radiography improved by zero to 13 percentage points in certain countries and dose reduction was from 10% to 85%. In mammography, poor quality, ranging from 10 to 29% of images in different countries was observed. The project increased attention to dose quantities and dose levels in computed tomography, although doses in most cases were not higher than reference levels. In this study 16-19% of patients in interventional cardiology received doses that have potential for either stochastic risk or tissue reaction. This multi-national study is the first of its kind in the Asia, and it provided insight into the situation and opportunities for improvement.


Subject(s)
Body Burden , Diagnostic Imaging/statistics & numerical data , Practice Patterns, Physicians'/statistics & numerical data , Radiation Injuries/epidemiology , Radiation Injuries/prevention & control , Radiation Monitoring/statistics & numerical data , Radiation Protection/statistics & numerical data , Adult , Asia/epidemiology , Child , Data Collection , Humans , Population Surveillance
3.
AJR Am J Roentgenol ; 198(5): 1021-31, 2012 May.
Article in English | MEDLINE | ID: mdl-22528891

ABSTRACT

OBJECTIVE: The purpose of this study was to assess the frequency of pediatric CT in 40 less-resourced countries and to determine the level of appropriateness in CT use. MATERIALS AND METHODS: Data on the increase in the number of CT examinations during 2007 and 2009 and appropriate use of CT examinations were collected, using standard forms, from 146 CT facilities at 126 hospitals. RESULTS: The lowest frequency of pediatric CT examinations in 2009 was in European facilities (4.3%), and frequencies in Asia (12.2%) and Africa (7.8%) were twice as high. Head CT is the most common CT examination in children, amounting to nearly 75% of all pediatric CT examinations. Although regulations in many countries assign radiologists with the main responsibility of deciding whether a radiologic examination should be performed, in fact, radiologists alone were responsible for only 6.3% of situations. Written referral guidelines for imaging were not available in almost one half of the CT facilities. Appropriateness criteria for CT examinations in children did not always follow guidelines set by agencies, in particular, for patients with accidental head trauma, infants with congenital torticollis, children with possible ventriculoperitoneal shunt malfunction, and young children (< 5 years old) with acute sinusitis. In about one third of situations, nonavailability of previous images and records on previously received patient doses have the potential to lead to unnecessary examinations and radiation doses. CONCLUSION: With increasing use of CT in children and a lack of use of appropriateness criteria, there is a strong need to implement guidelines to avoid unnecessary radiation doses to children.


Subject(s)
Practice Patterns, Physicians'/statistics & numerical data , Tomography, X-Ray Computed/statistics & numerical data , Africa , Asia , Child , Child, Preschool , Europe , Humans , Infant , Infant, Newborn , International Agencies , Latin America , Radiation Dosage , Radiation Protection , Surveys and Questionnaires
4.
Eur J Radiol ; 81(9): 2161-8, 2012 Sep.
Article in English | MEDLINE | ID: mdl-21665395

ABSTRACT

PURPOSE: The objective is to study mammography practice from an optimisation point of view by assessing the impact of simple and immediately implementable corrective actions on image quality. MATERIALS AND METHODS: This prospective multinational study included 54 mammography units in 17 countries. More than 21,000 mammography images were evaluated using a three-level image quality scoring system. Following initial assessment, appropriate corrective actions were implemented and image quality was re-assessed in 24 units. RESULTS: The fraction of images that were considered acceptable without any remark in the first phase (before the implementation of corrective actions) was 70% and 75% for cranio-caudal and medio-lateral oblique projections, respectively. The main causes for poor image quality before corrective actions were related to film processing, damaged or scratched image receptors, or film-screen combinations that are not spectrally matched, inappropriate radiographic techniques and lack of training. Average glandular dose to a standard breast was 1.5 mGy (mean and range 0.59-3.2 mGy). After optimisation the frequency of poor quality images decreased, but the relative contributions of the various causes remained similar. Image quality improvements following appropriate corrective actions were up to 50 percentage points in some facilities. CONCLUSIONS: Poor image quality is a major source of unnecessary radiation dose to the breast. An increased awareness of good quality mammograms is of particular importance for countries that are moving towards introduction of population-based screening programmes. The study demonstrated how simple and low-cost measures can be a valuable tool in improving of image quality in mammography.


Subject(s)
Image Interpretation, Computer-Assisted/standards , Mammography/statistics & numerical data , Mammography/standards , Practice Guidelines as Topic , Quality Assurance, Health Care/statistics & numerical data , Radiometry/statistics & numerical data , Radiometry/standards , Africa , Asia , Europe, Eastern , Humans , Radiation Dosage , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS