1.
Leukemia ; 15(10): 1572-81, 2001 Oct.
Article in English | MEDLINE | ID: mdl-11587215

ABSTRACT

Platelet transfusion is widely used to prevent bleeding in patients with severe thrombocytopenia. The maximal storage duration of platelet concentrates is usually 5 days, due to the platelet storage lesion that impairs their functions when stored for longer times. Some of the morphological and biochemical changes that characterize this storage lesion are reminiscent of cell death by apoptosis. The present study analyzed whether proteins involved in nucleated cell apoptosis could play a role in the platelet storage lesion. Storage of leukocyte-depleted platelets obtained by apheresis is associated with a late and limited activation of caspases, mainly caspase-3. This event correlates with an increased expression of the pro-apoptotic BH3-only protein Bim in the particulate fraction and a slight and late release of the pro-apoptotic mitochondrial protein Diablo/Smac in the cytosol. Platelets do not express the death receptors Fas, DR4 and DR5 on their plasma membrane, while the expression of the decoy receptor DcR2 increases progressively during platelet storage. Addition of low concentrations of the cryoprotector dimethylsulfoxide accelerates platelet caspase activation during storage, an effect that is partially prevented by the caspase inhibitor z-VAD-fmk. Altogether, DcR2 expression on the plasma membrane is an early event while caspase activation is a late event during platelet storage. These observations suggest that caspases are unlikely to account for the platelet storage lesion. As a consequence, addition of caspase inhibitors may not improve the quality of platelet concentrates stored in standard conditions.


Subject(s)
Blood Platelets/metabolism , Caspases/metabolism , Membrane Proteins , Proto-Oncogene Proteins , Receptors, Tumor Necrosis Factor/metabolism , Apoptosis , Apoptosis Regulatory Proteins , Bcl-2-Like Protein 11 , Blood Platelets/enzymology , Blood Preservation , Carrier Proteins/metabolism , Caspases/drug effects , Dimethyl Sulfoxide/pharmacology , Enzyme Activation/drug effects , Humans , Intracellular Signaling Peptides and Proteins , Mitochondrial Proteins/metabolism , Platelet Transfusion , Protein Precursors/metabolism , Specimen Handling , Time Factors , Tumor Necrosis Factor Decoy Receptors
2.
Transfus Apher Sci ; 25(1): 67-72, 2001 Aug.
Article in English | MEDLINE | ID: mdl-11791767

ABSTRACT

The latest generation of cell separators such as Trima (Gambro), Amicus (Baxter) and AS-TEC 204 (Fresenius), allow the collection of leucocyte-reduced platelet concentrates without secondary filtration. Fresenius has recently developed the COMTEC cell separator whose performance has been evaluated by several teams in France. This new cell separator is an improved version of the Fresenius AS-TEC 204 cell separator, designed to allow more efficient platelet collections. This study reports on the experience of six French teams (from Bordeaux, Clermont-Ferrand, Creteil, Dijon, Lille and Nancy) who obtained 696 leucocyte-reduced plateletpheresis concentrates in the course of collection using the new Fresenius COMTEC cell separator. All healthy volunteer donors fulfilled French selection criteria for platelet apheresis. Donors were eligible if they had suitable venous accesses, if their bodyweight was *50 kg and if their pre-apheresis platelet count was >150 x 10(9) l(-1). Between 4606 and 5229 ml of blood were processed. The mean volume of the platelet concentrates was between 439 and 493 ml (mean 460 +/- 63 ml). The platelet yield was of the order of 5.18 +/- 1.02 x 10(11) with only one platelet concentrate below the norm of 2 x 10(11) platelets (0.91 x 10(11)). No plausible explanation for this was found. The residual leucocyte levels conform to current norms. The platelet concentrates contained less than 1 x 10(6) leucocytes per concentrate (mean 0.233 +/- 0.150 x 10(6) leucocytes) in more than 97% of the components produced with >95% statistical confidence. The efficacy of the cell separator (52.44 +/- 7.35%) is comparable to that of other separators. The Fresenius COMTEC cell separator makes it possible to obtain leucocyte-reduced platelet concentrates which comply with current standards both in terms of platelet content and residual leucocyte level.


Subject(s)
Glucose/analogs & derivatives , Plateletpheresis/instrumentation , Adult , Anticoagulants/adverse effects , Blood Donors , Blood Volume , Body Weight , Citric Acid/adverse effects , Equipment Design , Female , France , Glucose/adverse effects , Humans , Lymphocyte Depletion/instrumentation , Male , Platelet Count , Safety