Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Medicine (Baltimore) ; 103(8): e36909, 2024 Feb 23.
Article in English | MEDLINE | ID: mdl-38394543

ABSTRACT

This study uses machine learning and population data to analyze major determinants of blood transfusion among patients with hip arthroplasty. Retrospective cohort data came from Korea National Health Insurance Service claims data for 19,110 patients aged 65 years or more with hip arthroplasty in 2019. The dependent variable was blood transfusion (yes vs no) in 2019 and its 31 predictors were included. Random forest variable importance and Shapley Additive Explanations were used for identifying major predictors and the directions of their associations with blood transfusion. The random forest registered the area under the curve of 73.6%. Based on random forest variable importance, the top-10 predictors were anemia (0.25), tranexamic acid (0.17), age (0.16), socioeconomic status (0.05), spinal anesthesia (0.05), general anesthesia (0.04), sex (female) (0.04), dementia (0.03), iron (0.02), and congestive heart failure (0.02). These predictors were followed by their top-20 counterparts including cardiovascular disease, statin, chronic obstructive pulmonary disease, diabetes mellitus, chronic kidney disease, peripheral vascular disease, liver disease, solid tumor, myocardial infarction and hypertension. In terms of max Shapley Additive Explanations values, these associations were positive, e.g., anemia (0.09), tranexamic acid (0.07), age (0.09), socioeconomic status (0.05), spinal anesthesia (0.05), general anesthesia (0.04), sex (female) (0.02), dementia (0.03), iron (0.04), and congestive heart failure (0.03). For example, the inclusion of anemia, age, tranexamic acid or spinal anesthesia into the random forest will increase the probability of blood transfusion among patients with hip arthroplasty by 9%, 7%, 9% or 5%. Machine learning is an effective prediction model for blood transfusion among patients with hip arthroplasty. The high-risk group with anemia, age and comorbid conditions need to be treated with tranexamic acid, iron and/or other appropriate interventions.


Subject(s)
Anemia , Antifibrinolytic Agents , Arthroplasty, Replacement, Hip , Dementia , Heart Failure , Tranexamic Acid , Humans , Aged , Female , Erythrocyte Transfusion , Artificial Intelligence , Retrospective Studies , Anemia/epidemiology , Anemia/therapy , Machine Learning , National Health Programs , Iron , Blood Loss, Surgical
2.
J Clin Med ; 12(18)2023 Sep 18.
Article in English | MEDLINE | ID: mdl-37762980

ABSTRACT

Knee osteoarthritis (KOA) is a prevalent common cause of disability and pain among adults. Transcutaneous radiofrequency (RF) diathermy and therapeutic ultrasound (US) are commonly employed treatments for addressing musculoskeletal conditions. This study aims to evaluate and compare the clinical effectiveness of transcutaneous 4.4 MHz RF diathermy and therapeutic US therapy in individuals diagnosed with KOA. A total of 108 patients with KOA were randomly assigned to either the RF or US groups. Each participant underwent a series of 10 treatment sessions over four weeks and was evaluated at different time points. The assessments included physical evaluations, vital sign measurements, the Numeric Rating Scale (NRS) for pain, Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) scores, the Lequesne index, gait analysis, the 36-Item Short Form Health Survey (SF-36), and analysis of adverse responses. Both groups showed significant differences in NRS, WOMAC scores, and Lequesne index compared to baseline values at both the 10th treatment session and the one-month follow-up assessment. However, no significant disparities were observed between the two groups at each assessment point. In the gait analysis, following the 10th treatment, the RF group showed significant changes in stride length and stride velocity compared to baseline. Four weeks after the completion of treatment, both groups exhibited significant alterations in stride length and stride velocity when compared to baseline measurements. However, regarding cadence, only the RF group exhibited a significant difference compared to baseline. The findings suggest that transcutaneous 4.4 MHz RF diathermy displays a comparable effectiveness to therapeutic US in reducing pain and enhancing functional capacity among individuals with KOA. Further research endeavors are warranted to advance the efficacy of noninvasive treatments for KOA.

3.
Medicina (Kaunas) ; 59(9)2023 Aug 23.
Article in English | MEDLINE | ID: mdl-37763638

ABSTRACT

Background and Objectives: Cerebral ischemia is one of the major preoperative complications. Dexmedetomidine is a well-known sedative-hypnotic agent that has potential organ-protective effects. We examine the miRNAs associated with preconditioning effects of dexmedetomidine in cerebral ischemia. Materials and Methods: Transient infarcts were induced in mice via reperfusion after temporary occlusion of one side of the middle cerebral artery. A subset of these mice was exposed to dexmedetomidine prior to cerebral infarction and miRNA profiling of the whole brain was performed. We administered dexmedetomidine and miRNA-323-5p mimic/inhibitor to oxygen-glucose deprivation/reoxygenation astrocytes. Additionally, we administered miR-323-5p mimic and inhibitor to mice via intracerebroventricular injection 2 h prior to induction of middle cerebral artery occlusion. Results: The infarct volume was significantly lower in the dexmedetomidine-preconditioned mice. Analysis of brain samples revealed an increased expression of five miRNAs and decreased expression of three miRNAs in the dexmedetomidine-pretreated group. The viability of cells significantly increased and expression of miR-323-5p was attenuated in the dexmedetomidine-treated oxygen-glucose deprivation/reoxygenation groups. Transfection with anti-miR-323-5p contributed to increased astrocyte viability. When miRNA-323-5p was injected intraventricularly, infarct volume was significantly reduced when preconditioned with the miR-323-5p inhibitor compared with mimic and negative control. Conclusions: Dexmedetomidine has a protective effect against transient neuronal ischemia-reperfusion injury and eight specific miRNAs were profiled. Also, miRNA-323-5p downregulation has a cell protective effect under ischemic conditions both in vivo and in vitro. Our findings suggest the potential of the miR-323-5p inhibitor as a therapeutic agent against cerebral infarction.


Subject(s)
Brain Ischemia , Dexmedetomidine , MicroRNAs , Reperfusion Injury , Rats , Mice , Animals , Dexmedetomidine/pharmacology , Dexmedetomidine/therapeutic use , Neuroprotection , Rats, Sprague-Dawley , Brain Ischemia/complications , MicroRNAs/genetics , Glucose/metabolism , Infarction, Middle Cerebral Artery/complications , Infarction, Middle Cerebral Artery/drug therapy , Oxygen/metabolism , Reperfusion Injury/drug therapy , Reperfusion Injury/prevention & control , Apoptosis
4.
J Synchrotron Radiat ; 26(Pt 4): 1101-1109, 2019 Jul 01.
Article in English | MEDLINE | ID: mdl-31274433

ABSTRACT

A wake monochromator based on a large-area diamond single crystal for hard X-ray self-seeding has been successfully installed and commissioned in the hard X-ray free-electron laser (FEL) at the Pohang Accelerator Laboratory with international collaboration. For this commissioning, the self-seeding was demonstrated with a low bunch charge (40 pC) and the nominal bunch charge (180 pC) of self-amplified spontaneous emission (SASE) operation. The FEL pulse lengths were estimated as 7 fs and 29.5 fs, respectively. In both cases, the average spectral brightness increased by more than three times compared with the SASE mode. The self-seeding experiment was demonstrated for the first time using a crystal with a thickness of 30 µm, and a narrow bandwidth of 0.22 eV (full width at half-maximum) was obtained at 8.3 keV, which confirmed the functionality of a crystal with such a small thickness. In the nominal bunch-charge self-seeding experiment, the histogram of the intensity integrated over a 1 eV bandwidth showed a well defined Gaussian profile, which is evidence of the saturated FEL and a minimal electron-energy jitter (∼1.2 × 10-4) effect. The corresponding low photon-energy jitter (∼2.4 × 10-4) of the SASE FEL pulse, which is two times lower than the Pierce parameter, enabled the seeding power to be maximized by maintaining the spectral overlap between SASE FEL gain and the monochromator.

5.
J Synchrotron Radiat ; 26(Pt 4): 1127-1138, 2019 Jul 01.
Article in English | MEDLINE | ID: mdl-31274436

ABSTRACT

PAL-XFEL utilizes a three-chicane bunch compression (3-BC) scheme (the very first of its kind in operation) for free-electron laser (FEL) operation. The addition of a third bunch compressor allows for more effective mitigation of coherent synchrotron radiation during bunch compression and an increased flexibility of system configuration. Start-to-end simulations of the effects of radiofrequency jitter on the electron beam performance show that using the 3-BC scheme leads to better performance compared with the two-chicane bunch compression scheme. Together with the high performance of the linac radiofrequency system, it enables reliable operation of PAL-XFEL with unprecedented stability in terms of arrival timing, pointing and intensity; an arrival timing jitter of better than 15 fs, a transverse position jitter of smaller than 10% of the photon beam size, and an FEL intensity jitter of smaller than 5% are consistently achieved.

SELECTION OF CITATIONS
SEARCH DETAIL
...