Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 158
Filter
1.
Article in English | MEDLINE | ID: mdl-38760425

ABSTRACT

Considerable research has suggested that certain cognitive domains may contribute to cocaine misuse. However, there are gaps in the literature regarding whether cognitive performance before drug exposure predicts susceptibility to cocaine self-administration and how cognitive performance relates to future cocaine intake. Thus, the present study aimed to examine cognitive performance, as measured using automated CANTAB cognitive battery, prior to and following acquisition of cocaine self-administration under a concurrent drug vs. food choice procedure in female and male socially housed cynomolgus macaques. The cognitive battery consisted of measures of associative learning (stimulus and compound discrimination tasks), behavioral flexibility (intradimensional and extradimensional tasks), and behavioral inhibition (stimulus discrimination reversal, SDR, and extra-dimensional reversal tasks). After assessing cognitive performance, monkeys were trained to self-administer cocaine (saline, 0.01-0.1 mg/kg/injection) under a concurrent cocaine vs. food schedule of reinforcement. After a history of cocaine self-administration across 3-4 years, the cognitive battery was re-assessed and compared with sensitivity to cocaine reinforcement. Results showed drug-naïve monkeys that were less accurate on the SDR task, measuring behavioral inhibition, were more sensitive to cocaine reinforcement under the concurrent cocaine vs. food choice procedure. Furthermore, following chronic cocaine self-administration, cocaine intake was a negative predictor of accuracy on the SDR behavioral inhibition task. After cocaine maintenance, monkeys with higher cocaine intakes required more trials to complete the SDR behavioral inhibition task and made more incorrect responses during these trials. No sex or social rank differences were noted. Overall, these findings suggest that cognitive performance may influence vulnerability to cocaine misuse. Also, chronic cocaine may decrease levels of behavioral inhibition as measured via the SDR task in both females and males.

2.
J Nucl Med ; 2024 May 09.
Article in English | MEDLINE | ID: mdl-38724279

ABSTRACT

Fibroblast activation protein-α (FAP) is often highly expressed by sarcoma cells and by sarcoma-associated fibroblasts in the tumor microenvironment. This makes it a promising target for imaging and therapy. The level of FAP expression and the diagnostic value of 68Ga-FAP inhibitor (FAPI) PET for sarcoma subtypes are unknown. We assessed the diagnostic performance and accuracy of 68Ga-FAPI PET in various bone and soft-tissue sarcomas. Potential eligibility for FAP-targeted radiopharmaceutical therapy (FAP-RPT) was evaluated. Methods: This prospective observational trial enrolled 200 patients with bone and soft-tissue sarcoma who underwent 68Ga-FAPI PET/CT and 18F-FDG PET/CT (186/200, or 93%) for staging or restaging. The number of lesions detected and the uptake (SUVmax) of the primary tumor, lymph nodes, and visceral and bone metastases were analyzed. The Wilcoxon test was used for semiquantitative assessment. The association of 68Ga-FAPI uptake intensity, histopathologic grade, and FAP expression in sarcoma biopsy samples was analyzed using Spearman r correlation. The impact of 68Ga-FAPI PET on clinical management was investigated using questionnaires before and after PET/CT. Eligibility for FAP-RPT was defined by an SUVmax greater than 10 for all tumor regions. Results: 68Ga-FAPI uptake was heterogeneous among sarcoma subtypes. The 3 sarcoma entities with the highest uptake (mean SUVmax ± SD) were solitary fibrous tumor (24.7 ± 11.9), undifferentiated pleomorphic sarcoma (18.8 ± 13.1), and leiomyosarcoma (15.2 ± 10.2). Uptake of 68Ga-FAPI versus 18F-FDG was significantly higher in low-grade sarcomas (10.4 ± 8.5 vs. 7.0 ± 4.5, P = 0.01) and in potentially malignant intermediate or unpredictable sarcomas without a World Health Organization grade (not applicable [NA]; 22.3 ± 12.5 vs. 8.5 ± 10.0, P = 0.0004), including solitary fibrous tumor. The accuracy, as well as the detection rates, of 68Ga-FAPI was higher than that of 18F-FDG in low-grade sarcomas (accuracy, 92.2 vs. 80.0) and NA sarcomas (accuracy, 96.9 vs. 81.9). 68Ga-FAPI uptake and the histopathologic FAP expression score (n = 89) were moderately correlated (Spearman r = 0.43, P < 0.0002). Of 138 patients, 62 (45%) with metastatic sarcoma were eligible for FAP-RPT. Conclusion: In patients with low-grade and NA sarcomas, 68Ga-FAPI PET demonstrates uptake, detection rates, and accuracy superior to those of 18F-FDG PET. 68Ga-FAPI PET criteria identified eligibility for FAP-RPT in about half of sarcoma patients.

3.
Pharmacol Rev ; 76(2): 199-227, 2024 Feb 13.
Article in English | MEDLINE | ID: mdl-38351075

ABSTRACT

Extracellular vesicles (EVs) have emerged as an attractive liquid biopsy approach in the diagnosis and prognosis of multiple diseases and disorders. The feasibility of enriching specific subpopulations of EVs from biofluids based on their unique surface markers has opened novel opportunities to gain molecular insight from various tissues and organs, including the brain. Over the past decade, EVs in bodily fluids have been extensively studied for biomarkers associated with various neurological disorders, such as Alzheimer's disease, Parkinson's disease, schizophrenia, bipolar disorder, major depressive disorders, substance use disorders, human immunodeficiency virus-associated neurocognitive disorder, and cancer/treatment-induced neurodegeneration. These studies have focused on the isolation and cargo characterization of either total EVs or brain cells, such as neuron-, astrocyte-, microglia-, oligodendrocyte-, pericyte-, and endothelial-derived EVs from biofluids to achieve early diagnosis and molecular characterization and to predict the treatment and intervention outcomes. The findings of these studies have demonstrated that EVs could serve as a repetitive and less invasive source of valuable molecular information for these neurological disorders, supplementing existing costly neuroimaging techniques and relatively invasive measures, like lumbar puncture. However, the initial excitement surrounding blood-based biomarkers for brain-related diseases has been tempered by challenges, such as lack of central nervous system specificity in EV markers, lengthy protocols, and the absence of standardized procedures for biological sample collection, EV isolation, and characterization. Nevertheless, with rapid advancements in the EV field, supported by improved isolation methods and sensitive assays for cargo characterization, brain cell-derived EVs continue to offer unparallel opportunities with significant translational implications for various neurological disorders. SIGNIFICANCE STATEMENT: Extracellular vesicles present a less invasive liquid biopsy approach in the diagnosis and prognosis of various neurological disorders. Characterizing these vesicles in biofluids holds the potential to yield valuable molecular information, thereby significantly impacting the development of novel biomarkers for various neurological disorders. This paper has reviewed the methodology employed to isolate extracellular vesicles derived from various brain cells in biofluids, their utility in enhancing the molecular understanding of neurodegeneration, and the potential challenges in this research field.


Subject(s)
Alzheimer Disease , Depressive Disorder, Major , Extracellular Vesicles , Humans , Depressive Disorder, Major/pathology , Extracellular Vesicles/pathology , Liquid Biopsy , Biomarkers
4.
Int J Cardiol Heart Vasc ; 50: 101340, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38313450

ABSTRACT

Purpose of the Report: Combined cardiac 68Ga-Fibroblast-Activation Protein-alpha inhibitor (FAPI) positron-emission tomography (PET) and cardiac magnetic resonance imaging (MRI) constitute a novel diagnostic tool in patients for the assessment of myocardial damage after an acute myocardial infarction (AMI). Purpose of this pilot study was to evaluate simultaneous Ga-68-FAPI-46-PET/MR imaging in the delayed phase after AMI. Material and Methods: Eleven patients underwent hybrid 68Ga-FAPI-46 PET/MRI post AMI. Standardized uptake values and fibroblast activation volume (FAV) were calculated and correlated with serum biomarkers and MRI parameters. Results: Significant 68Ga-FAPI-46 uptake could be demonstrated in 11 (100 %) patients after a mean period of 30.9 ± 22.0 days. FAV significantly exceeded the infarction size in MRI and showed a good correlation to MRI parameters as well as to serum biomarkers of myocardial damage. Conclusions: 68Ga-FAPI-46 PET/MRI offers molecular and morphological imaging of affected myocardium after AMI. This study demonstrates ongoing fibroblast activation in a delayed phase after AMI and generates hypotheses for future studies while aiming for a better understanding of myocardial remodeling following ischemic tissue damage.

5.
J Nucl Med ; 2024 Feb 08.
Article in English | MEDLINE | ID: mdl-38331453

ABSTRACT

To assess the diagnostic accuracy of 68Ga-labeled fibroblast activation protein inhibitor (FAPI) and 18F-labeled FDG PET for the detection of various tumors, we performed a head-to-head comparison of both imaging modalities across a range of tumor entities as part of our ongoing 68Ga-FAPI PET observational trial. Methods: The study included 115 patients with 8 tumor entities who received imaging with 68Ga-FAPI for tumor staging or restaging between October 2018 and March 2022. Of those, 103 patients received concomitant imaging with 68Ga-FAPI and 18F-FDG PET and had adequate lesion validation for accuracy analysis. Each scan was evaluated for the detection of primary tumor, lymph nodes, and visceral and bone metastases. True or false positivity and negativity to detected lesions was assigned on the basis of histopathology from biopsies or surgical excision, as well as imaging validation. Results: 68Ga-FAPI PET revealed higher accuracy than 18F-FDG PET in the detection of colorectal cancer (n = 14; per-patient, 85.7% vs. 78.6%; per-region, 95.6% vs. 91.1%) and prostate cancer (n = 22; per-patient, 100% vs. 90.9%; per-region, 96.4% vs. 92.7%). 68Ga-FAPI PET and 18F-FDG PET had comparable per-patient accuracy in detecting breast cancer (n = 16, 100% for both) and head and neck cancers (n = 10, 90% for both modalities). 68Ga-FAPI PET had lower per-patient accuracy than 18F-FDG PET in cancers of the bladder (n = 12, 75% vs. 100%) and kidney (n = 10, 80% vs. 90%), as well as lymphoma (n = 9, 88.9% vs. 100%) and myeloma (n = 10, 80% vs. 90%). Conclusion: 68Ga-FAPI PET demonstrated higher diagnostic accuracy than 18F-FDG PET in the diagnosis of colorectal cancer and prostate cancer, as well as comparable diagnostic performance for cancers of the breast and head and neck. Accuracy and impact on management will be further assessed in an ongoing prospective interventional trial (NCT05160051).

6.
Psychopharmacology (Berl) ; 241(2): 263-274, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37882812

ABSTRACT

RATIONALE: Previous studies in socially housed monkeys examining acquisition of cocaine self-administration under fixed-ratio (FR) schedules of reinforcement found that subordinate males and dominant females were more vulnerable than their counterparts. OBJECTIVES: The present studies extended these findings in two ways: (1) to replicate the earlier study, in which female monkeys were studied after a relatively short period of social housing (~ 3 months) using cocaine-naïve female monkeys (n = 9; 4 dominant and 5 subordinate) living in well-established social groups (~ 18 months); and (2) in male monkeys (n = 3/social rank), we studied cocaine acquisition under a concurrent schedule, with an alternative, non-drug reinforcer available. RESULTS: In contrast to earlier findings, subordinate female monkeys acquired cocaine reinforcement (i.e., > saline reinforcement) at significantly lower cocaine doses compared with dominant monkeys. In the socially housed males, no dominant monkey acquired a cocaine preference (i.e., > 80% cocaine choice) over food, while two of three subordinate monkeys acquired cocaine reinforcement. In monkeys that did not acquire, the conditions were changed to an FR schedule with only cocaine available and after acquisition, returned to the concurrent schedule. In all monkeys, high doses of cocaine were chosen over food reinforcement. CONCLUSIONS: The behavioral data in females suggests that duration of social enrichment and stress can differentially impact vulnerability to cocaine reinforcement. The findings in socially housed male monkeys, using concurrent food vs. cocaine choice schedules of reinforcement, confirmed earlier social-rank differences using an FR schedule and showed that vulnerability could be modified by exposure to cocaine.


Subject(s)
Cocaine , Housing , Male , Female , Animals , Reinforcement, Psychology , Food , Self Administration , Reinforcement Schedule , Dose-Response Relationship, Drug
7.
Cereb Cortex ; 34(1)2024 01 14.
Article in English | MEDLINE | ID: mdl-38142289

ABSTRACT

Concerns about the potential neurotoxic effects of anesthetics on developing brain exist. When making clinical decisions, the timing and dosage of anesthetic exposure are critical factors to consider due to their associated risks. In our study, we investigated the impact of repeated anesthetic exposures on the brain development trajectory of a cohort of rhesus monkeys (n = 26) over their first 2 yr of life, utilizing longitudinal magnetic resonance imaging data. We hypothesized that early or high-dose anesthesia exposure could negatively influence structural brain development. By employing the generalized additive mixed model, we traced the longitudinal trajectories of brain volume, cortical thickness, and white matter integrity. The interaction analysis revealed that age and cumulative anesthetic dose were variably linked to white matter integrity but not to morphometric measures. Early high-dose exposure was associated with increased mean, axial, and radial diffusivities across all white matter regions, compared to late-low-dose exposure. Our findings indicate that early or high-dose anesthesia exposure during infancy disrupts structural brain development in rhesus monkeys. Consequently, the timing of elective surgeries and procedures that require anesthesia for children and pregnant women should be strategically planned to account for the cumulative dose of volatile anesthetics, aiming to minimize the potential risks to brain development.


Subject(s)
Anesthetics , White Matter , Humans , Animals , Child , Female , Pregnancy , Macaca mulatta , Diffusion Tensor Imaging/methods , Brain , Magnetic Resonance Imaging , White Matter/pathology , Anesthetics/toxicity
8.
J Nucl Med ; 64(12): 1910-1917, 2023 12 01.
Article in English | MEDLINE | ID: mdl-37973185

ABSTRACT

The fibroblast activation protein (FAP) is highly expressed on carcinoma-associated fibroblasts in the stroma of pancreatic cancer and thus is a promising target for imaging and therapy. Preliminary data on PET imaging with radiolabeled FAP inhibitors (FAPIs) demonstrate superior tumor detection. Here we assess the accuracy of FAP-directed PET in patients with pancreatic cancer. Methods: Of 64 patients with suspected or proven pancreatic cancer, 62 (97%) were included in the data analysis of the 68Ga-FAPI PET observational trial (NCT04571086). All of these patients underwent contrast-enhanced CT, and 38 patients additionally underwent 18F-FDG PET. The primary study endpoint was the association of 68Ga-FAPI PET uptake intensity and histopathologic FAP expression. Secondary endpoints were detection rate, diagnostic performance, interreader reproducibility, and change in management. Datasets were interpreted by 2 masked readers. Results: The primary endpoint was met: The association between 68Ga-FAPI SUVmax and histopathologic FAP expression was significant (Spearman r, 0.48; P = 0.04). For histopathology-validated lesions, 68Ga-FAPI PET showed high sensitivity and positive predictive values (PPVs) on per-patient (sensitivity, 100%; PPV, 96.3%) and per-region (sensitivity, 100%; PPV, 97.0%) bases. In a head-to-head comparison versus 18F-FDG or contrast-enhanced CT, 68Ga-FAPI detected more tumor on a per-lesion (84.7% vs. 46.5% vs. 52.9%), per-patient (97.4% vs. 73.7% vs. 92.1%), or per-region (32.6% vs. 18.8% vs. 23.7%) basis, respectively. 68Ga-FAPI PET readers showed substantial overall agreement on the basis of the Fleiss κ: primary κ, 0.77 (range, 0.66-0.88). Minor and major changes in clinical management occurred in 5 patients (8.4%) after 68Ga-FAPI PET. Conclusion: We confirmed an association of 68Ga-FAPI PET SUVmax and histopathologic FAP expression in pancreatic cancer patients. Additionally, we found high detection rate and diagnostic accuracy, superior to those of 18F-FDG PET/CT. 68Ga-FAPI might become a powerful diagnostic tool for pancreatic cancer work-up.


Subject(s)
Adenocarcinoma , Cancer-Associated Fibroblasts , Pancreatic Neoplasms , Quinolines , Humans , Adenocarcinoma/diagnostic imaging , Pancreatic Neoplasms/diagnostic imaging , Gallium Radioisotopes , Fluorodeoxyglucose F18 , Positron Emission Tomography Computed Tomography , Reproducibility of Results
9.
Drug Alcohol Depend ; 251: 110952, 2023 10 01.
Article in English | MEDLINE | ID: mdl-37699287

ABSTRACT

BACKGROUND: Individuals who use cocaine have high rates of co-morbid alcohol use and when ethanol and cocaine are administered concurrently, the metabolite cocaethylene is formed. Cocaethylene is equipotent to cocaine in blocking dopamine reuptake and substitutes for cocaine in drug discrimination studies. However, no previous work has directly compared the reinforcing strength of cocaine to cocaethylene. METHODS: In Experiment 1, three individually-housed adult male rhesus macaques self-administer cocaine under a progressive-ratio (PR) schedule of reinforcement, during daily 4-hr sessions. Under this schedule, the primary dependent variable is the number of injections received, or the break point (BP). Saline, cocaine (0.001-0.3mg/kg/injection) and cocaethylene (0.0003-0.1mg/kg/injection) dose-response curves were determined. In Experiment 2, two female cynomolgus and one rhesus macaque responded under a concurrent schedule of drug (cocaine or cocaethylene) vs. 1.0-g banana-flavored food pellets, during daily 1-hr sessions. RESULTS: Both cocaine and cocaethylene functioned as reinforcers under the PR and concurrent choice schedules of reinforcement. Under the PR schedule, peak BPs were not significantly different, nor were ED50 values on the ascending limb, suggesting that cocaethylene has equal reinforcing strength and potency to cocaine. Under the concurrent drug-food choice procedure, cocaethylene was also equally potent to cocaine. CONCLUSIONS: Under two schedules of reinforcement designed to assess reinforcing strength, cocaethylene and cocaine were equipotent and of equal reinforcing strength. Because cocaethylene has a longer duration of action, it is important for studies designed to evaluate treatments for cocaine use to also consider the effects of these interventions on cocaethylene.


Subject(s)
Cocaine , Animals , Male , Female , Macaca mulatta , Self Administration , Dose-Response Relationship, Drug , Cocaine/pharmacology , Reinforcement Schedule
10.
Pharmaceuticals (Basel) ; 16(7)2023 Jul 19.
Article in English | MEDLINE | ID: mdl-37513966

ABSTRACT

Corentin Warnier, Thibault Gendron, Muhammad Otabashi, Charles Vriamont and Alex Jackson were not included as authors in the original publication [...].

11.
J Nucl Med ; 64(10): 1540-1549, 2023 10.
Article in English | MEDLINE | ID: mdl-37474272

ABSTRACT

PET imaging using the somatostatin receptor 2 (SSTR2) antagonist satoreotide trizoxetan (SSO-120, previously OPS-202) could offer accurate tumor detection and screening for SSTR2-antagonist radionuclide therapy in patients with SSTR2-expressing small cell lung cancer (SCLC). The aim of this single-center study was to investigate tumor uptake and detection rates of 68Ga-SSO-120 in comparison to 18F-FDG PET in the initial staging of SCLC patients. Methods: Patients with newly diagnosed SCLC who underwent additional whole-body 68Ga-SSO-120 PET/CT during the initial diagnostic workup were retrospectively included. The mean administered activity was 139 MBq, and the mean uptake time was 60 min. Gold-standard staging 18F-FDG PET/CT was evaluated if available within 2 wk before or after 68Ga-SSO-120 PET if morphologic differences in CT images were absent. 68Ga-SSO-120- or 18F-FDG-positive lesions were reported in 7 anatomic regions (primary tumor, thoracic lymph node metastases, and distant metastases including pleural, contralateral pulmonary, liver, bone, and other) according to the TNM classification for lung cancer (eighth edition). Consensus TNM staging (derived from CT, endobronchial ultrasound-guided transbronchial needle aspiration, PET, and brain MRI) by a clinical tumor board served as the reference standard. Results: Thirty-one patients were included, 12 with limited and 19 with extensive disease according to the Veterans Administration Lung Study Group classification. 68Ga-SSO-120-positive tumor was detected in all patients (100%) and in 90 of the 217 evaluated regions (41.5%). Thirteen patients (42.0%) had intense average 68Ga-SSO-120 uptake (region-based mean SUVmax ≥ 10); 28 patients (90.3%) had average 68Ga-SSO-120 uptake greater than liver uptake (region-based mean peak tumor-to-liver ratio > 1). In 25 patients with evaluable 18F-FDG PET, primary tumor, thoracic lymph node metastases, and distant metastases were detected in 100%, 92%, and 64%, respectively, of all investigated patients by 68Ga-SSO-120 and in 100%, 92%, and 56%, respectively, by 18F-FDG PET. 68Ga-SSO-120 PET detected additional contralateral lymph node, liver, and brain metastases in 1, 1, and 2 patients, respectively (no histopathology available), and 18F-FDG PET detected additional contralateral lymph node metastases in 3 patients (1 confirmed, 1 systematic endobronchial ultrasound-guided transbronchial needle aspiration-negative, and 1 without available histopathology). None of these differences altered Veterans Administration Lung Study Group staging. The region-based monotonic correlation between 68Ga-SSO-120 and 18F-FDG uptake was low (Spearman ρ = 0.26-0.33). Conclusion: 68Ga-SSO-120 PET offers high diagnostic precision with comparable detection rates and additional complementary information to the gold standard, 18F-FDG PET. Consistent uptake in most patients warrants exploration of SSTR2-directed radionuclide therapy.


Subject(s)
Lung Neoplasms , Small Cell Lung Carcinoma , Humans , Positron Emission Tomography Computed Tomography/methods , Small Cell Lung Carcinoma/diagnostic imaging , Retrospective Studies , Fluorodeoxyglucose F18 , Gallium Radioisotopes , Lymphatic Metastasis , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/pathology , Neoplasm Staging
12.
Neuropsychopharmacology ; 48(10): 1436-1445, 2023 09.
Article in English | MEDLINE | ID: mdl-37349473

ABSTRACT

Brain imaging studies using positron emission tomography (PET) have shown that long-term cocaine use is associated with lower levels of dopamine (DA) D2/D3 receptors (D2/D3R); less consistent are the effects on DA transporter (DAT) availability. However, most studies have been conducted in male subjects (humans, monkeys, rodents). In this study, we used PET imaging in nine drug-naïve female cynomolgus monkeys to determine if baseline measures of DAT, with [18F]FECNT, and D2/D3R availability, with [11C]raclopride, in the caudate nucleus, putamen and ventral striatum were associated with rates of cocaine self-administration and if these measures changed during long-term (~13 months) cocaine self-administration and following time-off (3-9 months) from cocaine. Cocaine (0.2 mg/kg/injection) and 1.0 g food pellets were available under a multiple fixed-interval (FI) 3-min schedule of reinforcement. In contrast to what has been observed in male monkeys, baseline D2/D3R availability was positively correlated with rates of cocaine self-administration only during the first week of exposure; DAT availability did not correlate with cocaine self-administration. D2/D3R availability decreased ~20% following cumulative intakes of 100 and 1000 mg/kg cocaine; DAT availability did not significantly change. These reductions in D2/D3R availability did not recover over 9 months of time-off from cocaine. To determine if these reductions were reversible, three monkeys were implanted with osmotic pumps that delivered raclopride for 30 days. We found that chronic treatment with the D2/D3R antagonist raclopride increased D2/D3R availability in the ventral striatum but not in the other regions when compared to baseline levels. Over 13 months of self-administration, tolerance did not develop to the rate-decreasing effects of self-administered cocaine on food-reinforced responding, but number of injections and cocaine intake significantly increased over the 13 months. These data extend previous findings to female monkeys and suggest sex differences in the relationship between D2/D3R availability related to vulnerability and long-term cocaine use.


Subject(s)
Cocaine , Positron-Emission Tomography , Haplorhini , Animals , Female , Positron-Emission Tomography/methods , Dopamine Plasma Membrane Transport Proteins , Receptors, Dopamine D3 , Cocaine/administration & dosage , Cocaine/adverse effects , Self Administration , Raclopride
13.
Drug Alcohol Depend Rep ; 7: 100148, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37033159

ABSTRACT

Background: Studies of nonhuman primates with exposures of up to 100 days of cocaine self-administration (SA) have provided evidence that the central effects of cocaine progress over time. These durations of cocaine exposure, however, may be insufficient to capture the extent of the neurobiological alterations observed in cocaine users, many of whom use the drug for years. The goal of the present study was to determine whether 1.5 years of cocaine SA would result in further progression of alterations in functional brain activity. Methods: Adult male rhesus monkeys were exposed to 300 sessions of high-dose cocaine SA over 1.5 years. Following the final session rates of local cerebral glucose utilization (LCGU) were assessed with the 2-[14C]-deoxyglucose method and compared to rates of LCGU in control monkeys who responded for food reinforcement. In addition, LCGU in these animals was compared to a previously published group of monkeys that had self-administered cocaine or food for 100 sessions over a 4-5 month period. Results: Compared to 100 days of exposure, 300 days of cocaine SA further reduced LCGU in the post-commissural striatum and produced reductions in areas unaffected by the shorter duration of exposure, such as the hypothalamus, all of the amygdala, and large expanses of cortex. Conclusions: These findings demonstrate a clear progression of the impact of cocaine on functional activity with increasing durations of drug experience and have important implications for the development of potential strategies for the treatment of cocaine use disorder.

14.
J Nucl Med ; 64(7): 1049-1055, 2023 07.
Article in English | MEDLINE | ID: mdl-37024301

ABSTRACT

Management of cholangiocarcinoma is among other factors critically determined by accurate staging. Here, we aimed to assess the accuracy of PET/CT with the novel cancer fibroblast-directed 68Ga-fibroblast activation protein (FAP) inhibitor (FAPI)-46 tracer for cholangiocarcinoma staging and management guidance. Methods: Patients with cholangiocarcinoma from a prospective observational trial were analyzed. 68Ga-FAPI-46 PET/CT detection efficacy was compared with 18F-FDG PET/CT and conventional CT. SUVmax/tumor-to-background ratio (Wilcoxon test) and separately uptake for tumor grade and location (Mann-Whitney U test) were compared. Immunohistochemical FAP and glucose transporter 1 (GLUT1) expression of stromal and cancer cells was analyzed. The impact on therapy management was investigated by pre- and post-PET/CT questionnaires sent to the treating physicians. Results: In total, 10 patients (6 with intrahepatic cholangiocarcinoma and 4 with extrahepatic cholangiocarcinoma; 6 with grade 2 tumor and 4 with grade 3 tumor) underwent 68Ga-FAPI-46 PET/CT and conventional CT; 9 patients underwent additional 18F-FDG PET/CT. Immunohistochemical analysis was performed on the entire central tumor plain in 6 patients. Completed questionnaires were returned in 8 cases. Detection rates for 68Ga-FAPI-46 PET/CT, 18F-FDG PET/CT, and CT were 5, 5, and 5, respectively, for primary tumor; 11, 10, and 3, respectively, for lymph nodes; and 6, 4, and 2, respectively, for distant metastases. 68Ga-FAPI-46 versus 18F-FDG PET/CT SUVmax for primary tumor, lymph nodes, and distant metastases was 14.5 versus 5.2 (P = 0.043), 4.7 versus 6.7 (P = 0.05), and 9.5 versus 5.3 (P = 0.046), respectively, and tumor-to-background ratio (liver) was 12.1 versus 1.9 (P = 0.043) for primary tumor. Grade 3 tumors demonstrated a significantly higher 68Ga-FAPI-46 uptake than grade 2 tumors (SUVmax, 12.6 vs. 6.4; P = 0.009). Immunohistochemical FAP expression was high on tumor stroma (∼90% of cells positive), whereas GLUT1 expression was high on tumor cells (∼80% of cells positive). Overall, average expression intensity was estimated as grade 3 for FAP and grade 2 for GLUT1. Positive 68Ga-FAPI-46 PET findings led to a consequent biopsy workup and diagnosis of cholangiocarcinoma in 1 patient. However, patient treatment was not adjusted on the basis of 68Ga-FAPI-46 PET. Conclusion: 68Ga-FAPI-46 demonstrated superior radiotracer uptake, especially in grade 3 tumors, and lesion detection in patients with cholangiocarcinoma. In line with this result, immunohistochemistry demonstrated high FAP expression on tumor stroma. Accuracy is under investigation in an ongoing investigator-initiated trial.


Subject(s)
Bile Duct Neoplasms , Cholangiocarcinoma , Quinolines , Humans , Positron Emission Tomography Computed Tomography , Fluorodeoxyglucose F18 , Gallium Radioisotopes , Glucose Transporter Type 1 , Cholangiocarcinoma/diagnostic imaging , Radiopharmaceuticals , Bile Duct Neoplasms/diagnostic imaging , Bile Ducts, Intrahepatic
15.
Pharmacol Biochem Behav ; 225: 173545, 2023 04.
Article in English | MEDLINE | ID: mdl-37004977

ABSTRACT

Cocaine use disorder (CUD) is a significant problem worldwide, with no FDA-approved treatments. Epidemiological data indicate that only about 17 % of people that use cocaine will meet DSM criteria for CUD. Thus, the identification of biomarkers predictive of eventual cocaine use may be of great value. Two potentially useful predictors of CUD are social hierarchies in nonhuman primates and delay discounting. Both social rank and preference for a smaller, immediate reinforcer relative to a larger, delayed reinforcer have been predictive of CUD. Therefore, we wanted to determine if there was also a relationship between these two predictors of CUD. In the present study, monkeys cocaine-naive responded under a concurrent schedule of 1- vs. 3-food pellets and delivery of the 3-pellet option was delayed. The primary dependent variable was the indifference point (IP), which is the delay that results in 50 % choice for both options. In the initial determination of IP, there were no differences based on sex or social rank of the monkeys. When the delays were redetermined after ~25 baseline sessions (range 5-128 sessions), dominant females and subordinate males showed the largest increases in IP scores from the first determination to the second. Because 13 of these monkeys had prior PET scans of the kappa opioid receptor (KOR), we examined the relationship between KOR availability and IP values and found that the change in IP scores from the first to the second determination significantly negatively predicted average KOR availability in most brain regions. Future studies will examine acquisition to cocaine self-administration in these same monkeys, to determine if IP values are predictive of vulnerability to cocaine reinforcement.


Subject(s)
Cocaine , Delay Discounting , Animals , Male , Female , Macaca fascicularis , Receptors, Opioid, kappa , Choice Behavior , Cocaine/pharmacology , Phenotype , Self Administration , Dose-Response Relationship, Drug
16.
Neuropsychopharmacology ; 48(12): 1716-1723, 2023 11.
Article in English | MEDLINE | ID: mdl-37118057

ABSTRACT

Recent studies suggest that dopamine D3 receptors (D3R) may be a therapeutic target for opioid use disorders (OUD). This study examined the effects of the D3R partial agonist (±)VK4-40 and the D3R-selective antagonist (±)VK4-116, compared to the mu-opioid receptor antagonist naltrexone (NTX), in nonhuman primate models of OUD and antinociception. Adult male and female (N = 4/sex) cynomolgus monkeys were trained to self-administer oxycodone (0.003-0.1 mg/kg/injection) first under a fixed-ratio (FR) and then a progressive-ratio (PR) schedule of reinforcement during daily 1- and 4-hr sessions, respectively. Under the FR schedule, intravenous NTX (0.01-0.1 mg/kg), (±)VK4-116 (1.0-10 mg/kg), and (±)VK4-40 (1.0-10 mg/kg) were studied in combination with the peak oxycodone dose and a dose on the descending limb of the dose-effect curve; NTX and (±)VK4-40 were also studied at the peak of the PR dose-response curve (N = 4). Following saline extinction, each compound was examined on oxycodone-induced reinstatement. Finally, these compounds were assessed in adult male rhesus monkeys (N = 3) in a warm-water (38 °C, 50 °C, 54 °C) tail withdrawal assay. NTX decreased responding on the peak of the FR oxycodone dose-response curve, but increased responding on the descending limb. (±)VK4-40, but not (±)VK4-116, significantly decreased peak oxycodone self-administration; (±)VK4-40 did not increase responding on the descending limb. NTX and (±)VK4-40, but not (±)VK4-116, attenuated oxycodone-induced reinstatement. Under PR responding, NTX and (±)VK4-40 decreased breakpoints. Oxycodone-induced antinociception was attenuated by NTX, but not by (±)VK4-40 or (±)VK4-116. Together, these results suggest that further research evaluating the effects of (±)VK4-40 as a novel pharmacotherapy for OUD is warranted.


Subject(s)
Opioid-Related Disorders , Oxycodone , Receptors, Dopamine D3 , Animals , Female , Male , Analgesics, Opioid/pharmacology , Dopamine Agonists/pharmacology , Dopamine Antagonists/pharmacology , Dose-Response Relationship, Drug , Naltrexone/pharmacology , Oxycodone/administration & dosage , Receptors, Dopamine D3/drug effects , Self Administration , Macaca fascicularis
17.
J Pharmacol Exp Ther ; 384(3): 372-381, 2023 03.
Article in English | MEDLINE | ID: mdl-36507847

ABSTRACT

Although there are no Food and Drug Administration-approved treatments for cocaine use disorder, several modafinil analogs have demonstrated promise in reducing cocaine self-administration and reinstatement in rats. Furthermore, the range of dopamine transporter (DAT) compounds provides an opportunity to develop pharmacotherapeutics without abuse liability. This study extended the comparison of JJC8-088 and JJC8-091, the former compound having higher DAT affinity and predicted abuse liability, to rhesus monkeys using a concurrent cocaine versus food schedule of reinforcement. First, binding to striatal DAT was examined in cocaine-naïve monkey tissue. Next, intravenous pharmacokinetics of both JJC compounds were evaluated in cocaine-experienced male monkeys (n = 3/drug). In behavioral studies, acute and chronic administration of both compounds were evaluated in these same monkeys responding under a concurrent food versus cocaine (0 and 0.003-0.1 mg/kg per injection) schedule of reinforcement. In nonhuman primate striatum, JJC8-088 had higher DAT affinity compared with JJC8-091 (14.4 ± 9 versus 2730 ± 1270 nM, respectively). Both JJC compounds had favorable plasma pharmacokinetics for behavioral assessments, with half-lives of 1.1 hours and 3.5 hours for JJC8-088 (0.7 mg/kg, i.v.) and JJC8-091 (1.9 mg/kg, i.v.), respectively. Acute treatment with both compounds shifted the cocaine dose-response curve to the left. Chronic treatment with JJC8-088 decreased cocaine choice in two of the three monkeys, whereas JJC8-091 only modestly reduced cocaine allocation in one monkey. Differences in affinities of JJC8-091 DAT binding in monkeys compared with rats may account for the poor rodent-to-monkey translation. Future studies should evaluate atypical DAT blockers in combination with behavioral interventions that may further decrease cocaine choice. SIGNIFICANCE STATEMENT: Cocaine use disorder (CUD) remains a significant public health problem with no Food and Drug Administration-approved treatments. The ability of drugs that act in the brain in a similar manner to cocaine, but with lower abuse liability, has clinical implications for a treatment of CUD.


Subject(s)
Cocaine , Male , Rats , Animals , Cocaine/pharmacology , Dopamine Plasma Membrane Transport Proteins/metabolism , Macaca mulatta/metabolism , Dopamine Uptake Inhibitors/pharmacology , Self Administration , Dose-Response Relationship, Drug
18.
J Nucl Med ; 64(5): 711-716, 2023 05.
Article in English | MEDLINE | ID: mdl-36581374

ABSTRACT

We present an overview of our prospective fibroblast-activation protein inhibitor (FAPI) registry study across a 3-y period, with head-to-head comparison of tumor uptake in 68Ga-FAPI and 18F-FDG PET, as well as FAP immunohistochemistry. Methods: This is an interim analysis of the ongoing 68Ga-FAPI PET prospective observational trial at our department. Patients who underwent clinical imaging with 68Ga-FAPI PET between October 2018 and October 2021 were included. Tracer uptake was quantified by SUVmax for tumor lesions and by SUVmean for normal organs. PET tumor volume (40% isocontour) and tumor-to-background ratios were calculated. Correlation between SUVmax and FAP staining in tissue samples was analyzed. Results: In total, 324 patients with 21 different tumor entities underwent 68Ga-FAPI imaging; 237 patients additionally received 18F-FDG PET. The most common tumor entities were sarcoma (131/324, 40%), pancreatic cancer (67/324, 21%), and primary tumors of the brain (22/324, 7%). The mean primary tumor SUVmax was significantly higher for 68Ga-FAPI than 18F-FDG among pancreatic cancer (13.2 vs. 6.1, P < 0.001) and sarcoma (14.3 vs. 9.4, P < 0.001), and the same was true for mean SUVmax in metastatic lesions of pancreatic cancer (9.4 vs. 5.5, P < 0.001). Mean primary tumor maximum tumor-to-background ratio was significantly higher for 68Ga-FAPI than 18F-FDG across several tumor entities, most prominently pancreatic cancer (14.7 vs. 3.0, P < 0.001) and sarcoma (17.3 vs. 4.7, P < 0.001). Compared with 18F-FDG, 68Ga-FAPI showed superior detection for locoregional disease in sarcoma (52 vs. 48 total regions detected) and for distant metastatic disease in both sarcoma (137 vs. 131) and pancreatic cancer (65 vs. 57), respectively. Among 61 histopathology samples, there was a positive correlation between 68Ga-FAPI SUVmax and overall FAP immunohistochemistry score (r = 0.352, P = 0.005). Conclusion: 68Ga-FAPI demonstrates higher absolute uptake in pancreatic cancer and sarcoma, as well as higher tumor-to-background uptake along with improved tumor detection for pancreatic cancer, sarcoma, and other tumor entities when compared with 18F-FDG. 68Ga-FAPI is a new tool for tumor staging with theranostic potential.


Subject(s)
Pancreatic Neoplasms , Quinolines , Sarcoma , Soft Tissue Neoplasms , Humans , Fluorodeoxyglucose F18 , Gallium Radioisotopes , Prospective Studies , Fibroblasts , Positron Emission Tomography Computed Tomography , Observational Studies as Topic , Pancreatic Neoplasms
19.
J Nucl Med ; 64(4): 598-604, 2023 04.
Article in English | MEDLINE | ID: mdl-36357181

ABSTRACT

Intraoperative identification of positive resection margins (PRMs) in high-risk prostate cancer (PC) needs improvement. Cerenkov luminescence imaging (CLI) with 68Ga-PSMA-11 is promising, although limited by low residual activity and artificial signals. Here, we aimed to assess the value of CLI and flexible autoradiography (FAR) with 18F-PSMA-1007. Methods: Mice bearing subcutaneous PSMA-avid RM1-PGLS tumors were administered 18F-PSMA-1007, and PET/CT was performed. After the animals had been killed, organs were excised and measured signals in CLI and FAR CLI were correlated with tracer activity concentrations (ACs) obtained from PET/CT. For clinical assessment, 7 high-risk PC patients underwent radical prostatectomy immediately after preoperative 18F-PSMA PET/CT. Contrast-to-noise ratios (CNRs) were calculated for both imaging modalities in intact specimens and after incision above the index lesion. Results: In the heterotopic in vivo mouse model (n = 5), CLI did not detect any lesion. FAR CLI detected a distinct signal in all mice, with a lowest AC of 7.25 kBq/mL (CNR, 5.48). After incision above the index lesion of the prostate specimen, no increased signal was observed at the cancer area in CLI. In contrast, using FAR CLI, a signal was detectable in 6 of 7 patients. The AC in the missed index lesion was 1.85 kBq/mL, resulting in a detection limit of at least 2.06 kBq/mL. Histopathology demonstrated 2 PRMs, neither of which was predicted by CLI or FAR CLI. Conclusion: 18F-PSMA FAR CLI was superior to CLI in tracer-related signal detectability. PC was could be visualized in radical prostatectomy down to 2.06 kBq/mL. However, the detection of PRMs was limited. Direct anatomic correlation of FAR CLI is challenging because of the scintillator overlay.


Subject(s)
Prostate , Prostatic Neoplasms , Humans , Male , Animals , Mice , Prostate/diagnostic imaging , Prostate/surgery , Prostate/pathology , Positron Emission Tomography Computed Tomography/methods , Positron-Emission Tomography/methods , Autoradiography , Luminescence , Feasibility Studies , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/surgery , Prostatic Neoplasms/pathology , Gallium Radioisotopes , Prostatectomy/methods
20.
J Nucl Med ; 64(5): 738-743, 2023 05.
Article in English | MEDLINE | ID: mdl-36460340

ABSTRACT

18F-PSMA-1007 PET is used in the management of patients with prostate cancer. However, recent reports indicate a high rate of unspecific bone uptake (UBU) with 18F-PSMA-1007, which may lead to a false-positive diagnosis. UBU has not been evaluated thoroughly. Here, we evaluate the frequency of UBU and bone metastases separately for 18F-PSMA-1007 and 68Ga-PSMA-11 in biochemical recurrence (interindividual comparison). Additionally, we investigate UBU seen in 18F-PSMA-1007 through follow-up examinations (intraindividual comparison) using 68Ga-PSMA-11 PET, bone scintigraphy, and MRI. Methods: First, all patients (n = 383) who underwent 68Ga-PSMA-11 PET between January 2020 and December 2020 and all patients (n = 409) who underwent 18F-PSMA-1007 PET between January 2020 and November 2021 due to biochemical recurrence were included for an interindividual comparison of bone metastases and UBU rate. In a second approach, we regarded all patients with UBU in 18F-PSMA-1007, characterized by focal bone uptake with an SUVmax > 4 and prostate-specific antigen (PSA) ≤ 5 ng/mL, who underwent additional 68Ga-PSMA-11 PET (n = 17) (interindividual comparison). Of these, 12 patients also had bone scintigraphy and whole-body MRI within a 1- to 5-wk interval. Bone uptake seen on 18F-PSMA-1007 but not on any of the other 4 modalities (CT, MRI [n = 1], bone scanning, and 68Ga-PSMA-11 PET) was recorded as false-positive. Results: Patients scanned with 18F-PSMA-1007 PET had a significantly higher rate of UBU than those scanned with 68Ga-PSMA-11 (140 vs. 64; P < 0.001); however, the rate of bone metastases was not significantly different (72 vs. 64; P = 0.7). In the intraindividual comparison group, workup by CT, MRI, bone scanning, and 68Ga-PSMA-11 PET resulted in a positive predictive value for 18F-PSMA-1007 focal bone uptake (mean SUVmax, 6.1 ± 2.9) per patient and per lesion of 8.3% and 3.6%, respectively. Conclusion: In patients with PSA ≤ 5 ng/mL and SUV > 4 at biochemical recurrence, most 18F-PSMA-1007 focal bone uptake is likely to be false-positive and therefore due to UBU. In the case of low clinical likelihood of metastatic disease, 18F-PSMA-1007 bone uptake without morphologic surrogate should be assessed carefully with regard to localization and clinical context. However, the rate of bone metastases was not higher with 18F-PSMA-1007 in the clinical routine, indicating that experienced reporting physicians adjust for UBU findings.


Subject(s)
Bone Neoplasms , Prostatic Neoplasms , Male , Humans , Prostate-Specific Antigen , Positron Emission Tomography Computed Tomography/methods , Gallium Radioisotopes , Prostatic Neoplasms/diagnostic imaging , Prostatic Neoplasms/pathology , Magnetic Resonance Imaging , Bone Neoplasms/diagnostic imaging , Bone Neoplasms/secondary , Edetic Acid
SELECTION OF CITATIONS
SEARCH DETAIL
...