Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 13(1): 22990, 2023 12 27.
Article in English | MEDLINE | ID: mdl-38151567

ABSTRACT

White adipose tissue (WAT) is critical for whole-body energy metabolism, and its dysfunction leads to various metabolic disorders. In recent years, many studies have suggested that impaired mitochondria may contribute to obesity-related decline in adipose tissue function, but the detailed mechanisms remain unclear. To investigate these mechanisms, we carried out a comprehensive analysis of WAT from mice with diet-induced obesity. We discovered the transcription factor Parkin interactive substrate (PARIS or ZNF746), which suppresses the expression of peroxisome proliferator-activated receptor γ coactivator-1α (PGC-1α), a key regulator of mitochondrial biogenesis, to be accumulated in adipose progenitor cells from obese mice. Furthermore, we demonstrated that 3T3-L1 preadipocytes with overexpression of PARIS protein exhibited decreased mitochondrial biogenesis and impaired adipogenesis. Our results suggest that the accumulation of PARIS protein may be a novel component in the pathogenesis of obesity-related dysfunction in WAT.


Subject(s)
Adipogenesis , Organelle Biogenesis , Animals , Mice , 3T3-L1 Cells , Adipose Tissue, White/metabolism , Obesity/metabolism , Peroxisome Proliferator-Activated Receptor Gamma Coactivator 1-alpha/genetics , Peroxisome Proliferator-Activated Receptor Gamma Coactivator 1-alpha/metabolism , Stem Cells/metabolism , Transcription Factors/metabolism
2.
Heart Vessels ; 37(3): 513-516, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34406441

ABSTRACT

Device migration is one of serious complications in neonates and infants undergoing transcatheter closure of the patent ductus arteriosus (PDA). We hypothesize that neonates and young infants possess the distensibility of the ductus, which may be related to device migration. We retrospectively reviewed angiographic findings in 41 neonates and infants who underwent transcatheter closure of PDA. We measured diameters of the ductus at the pulmonary (PA) side, the center, and the aortic (AO) side before PDA closure, and the device center diameter after device closure. The distensibility index was defined as the ratio of the device center diameter after device deployment to the diameter at the center of the ductus before PDA closure. Age and weight at the procedure were 168 (117-260) days and 5.3 (4.3-6.9) kg, respectively. Thirty-seven subjects accomplished the successful device closure, and four subjects were declined because of the device instability or migration. Implanted devices included Amplatzer Duct Occluders in 33 subjects and Amplatzer Vascular Plug-2 in 8 subjects. The PDA diameters at PA side, at the center, AO side, and the device center diameter were 3.2 (2.2-4.3) mm, 4.7 (3.6-5.7) mm, 7.7 (6.3-9.4) mm, and 5.8 (4.2-6.9) mm, respectively. The PDA diameter before closure was not correlated age and weight. The distensibility index was 1.28 (1.06-1.64), which was significantly correlated to age (r = - 0.49, P = 0.001) and weight (r = - 0.53, P < 0.001). Infants with the younger age and the lower weight have the more distensible PDA, which may be a risk for device migration.


Subject(s)
Ductus Arteriosus, Patent , Ductus Arteriosus , Septal Occluder Device , Cardiac Catheterization/methods , Ductus Arteriosus/diagnostic imaging , Ductus Arteriosus, Patent/diagnostic imaging , Ductus Arteriosus, Patent/surgery , Humans , Infant , Infant, Newborn , Retrospective Studies , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL