Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Heart Rhythm ; 14(9): 1382-1387, 2017 09.
Article in English | MEDLINE | ID: mdl-28385672

ABSTRACT

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) are effective in terminating lethal arrhythmias, but little is known about the degree of health care utilization (HCU) after ICD therapies. OBJECTIVE: Using data from the managed ventricular pacing trial, we sought to identify the incidence and types of HCU in ICD patients after receiving ICD therapy (shocks or antitachycardia pacing [ATP]). METHODS: We analyzed HCU events (ventricular tachyarrhythmia [VTA]-related, heart failure-related, ICD implant procedure-related, ICD system-related, or other) and their association with ICD therapies (shocked ventricular tachycardia episode, ATP-terminated ventricular tachycardia episode, and inappropriately shocked episode). RESULTS: A total of 1879 HCUs occurred in 695 of 1030 subjects (80% primary prevention) and were classified as follows: 133 (7%) VTA-related, 373 (20%) heart failure-related, 97 (5%) implant procedure-related, 115 (6%) system-related, and 1160 (62%) other. Of 2113 treated VTA episodes, 1680 (80%) received ATP only and 433 (20%) received shocks. Stratifying VTA-related HCUs on the basis of the type of ICD therapy delivered, there were 25 HCUs per 100 shocked VTA episodes compared with 1 HCU per 100 ATP-terminated episodes. Inappropriate ICD shocks occurred in 8.7% of the subjects and were associated with 115 HCUs. The majority of HCUs (52%) began in the emergency department, and 66% of all HCUs resulted in hospitalization. CONCLUSION: For VTA-related HCUs, shocks are associated with a 25-fold increase in HCUs compared to VTAs treated by ATP only. Application of evidence-based strategies and automated device-based algorithms to reduce ICD shocks (higher rate cutoffs, use of ATP, and arrhythmia detection) may help reduce HCUs.


Subject(s)
Algorithms , Arrhythmias, Cardiac/therapy , Defibrillators, Implantable , Heart Ventricles/physiopathology , Patient Acceptance of Health Care , Arrhythmias, Cardiac/epidemiology , British Columbia/epidemiology , Female , Humans , Incidence , Male , Middle Aged , Primary Prevention/methods , Retrospective Studies , Treatment Outcome , United States/epidemiology
2.
PLoS One ; 7(1): e25387, 2012.
Article in English | MEDLINE | ID: mdl-22247754

ABSTRACT

OBJECTIVES: To identify genetic factors that would be predictive of individuals who require an implantable cardioverter-defibrillator (ICD), we conducted a genome-wide association study among individuals with an ICD who experienced a life-threatening arrhythmia (LTA; cases) vs. those who did not over at least a 3-year period (controls). BACKGROUND: Most individuals that receive implantable cardioverter-defibrillators never experience a life-threatening arrhythmia. Genetic factors may help identify who is most at risk. METHODS: Patients with an ICD and extended follow-up were recruited from 34 clinical sites with the goal of oversampling those who had experienced LTA, with a cumulative 607 cases and 297 controls included in the analysis. A total of 1,006 Caucasian patients were enrolled during a time period of 13 months. Arrhythmia status of 904 patients could be confirmed and their genomic data were included in the analysis. In this cohort, there were 704 males, 200 females, and the average age was 73.3 years. We genotyped DNA samples using the Illumina Human660 W Genotyping BeadChip and tested for association between genotype at common variants and the phenotype of having an LTA. RESULTS AND CONCLUSIONS: We did not find any associations reaching genome-wide significance, with the strongest association at chromosome 13, rs11856574 at P = 5×10⁻6. Loci previously implicated in phenotypes such as QT interval (measure of the time between the start of the Q wave and the end of the T wave as measured by electrocardiogram) were not found to be significantly associated with having an LTA. Although powered to detect such associations, we did not find common genetic variants of large effect associated with having a LTA in those of European descent. This indicates that common gene variants cannot be used at this time to guide ICD risk-stratification. TRIAL REGISTRATION: ClinicalTrials.gov NCT00664807.


Subject(s)
Arrhythmias, Cardiac/genetics , Arrhythmias, Cardiac/mortality , DNA Copy Number Variations/genetics , Defibrillators, Implantable , Genetic Variation/genetics , Genome-Wide Association Study , Aged , Case-Control Studies , Cohort Studies , Female , Follow-Up Studies , Genotype , Humans , Male , Survival Rate
SELECTION OF CITATIONS
SEARCH DETAIL
...