Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Diabetes Investig ; 13(10): 1685-1694, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35638355

ABSTRACT

AIMS/INTRODUCTION: This study aimed to identify the clinical factors affecting postoperative residual pancreatic ß-cell function, as assessed by the C-peptide index (CPI), and to investigate the association between perioperative CPI and the status of diabetes management after pancreatectomy. MATERIALS AND METHODS: The associations between perioperative CPI and clinical background, including surgical procedures of pancreatectomy, were analyzed in 47 patients who underwent pancreatectomy, and were assessed for pre-and postoperative CPI. The association between perioperative CPI and glycemic control after pancreatectomy was investigated. RESULTS: The low postoperative CPI group (CPI <0.7) had longer duration of diabetes (17.5 ± 14.5 vs 5.5 ± 11.0 years, P = 0.004), a higher percentage of sulfonylurea users (41.7 vs 8.7%, P = 0.003) and a greater number of drug categories used for diabetes treatment (1.9 ± 1.1 vs 0.8 ± 0.8, P <0.001) than did the high postoperative CPI group. Postoperative CPI was higher (1.4 ± 1.2 vs 0.7 ± 0.6, P = 0.039) in patients with low glycosylated hemoglobin (<7.0%) at 6 months after pancreatectomy; preoperative (2.0 ± 1.5 vs 0.7 ± 0.5, P = 0.012) and postoperative CPI (2.5 ± 1.4 vs 1.4 ± 1.1, P = 0.020) were higher in non-insulin users than in insulin users at 6 months after surgery. CONCLUSIONS: The duration of diabetes and preoperative diabetes treatment were associated with residual pancreatic ß-cell function after pancreatectomy. Furthermore, perioperative ß-cell function as assessed by CPI was associated with diabetes management status after pancreatectomy.


Subject(s)
Diabetes Mellitus , Pancreatectomy , Humans , C-Peptide , Diabetes Mellitus/etiology , Glycated Hemoglobin , Postoperative Complications/etiology , Retrospective Studies
2.
Diabetol Int ; 12(3): 324-329, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34150440

ABSTRACT

Sensor-augmented insulin pump therapy with a predictive low glucose suspend (SAP-PLGS) feature is a remarkably progressed modality for the glycemic management of patients with type 1 diabetes. This technology avoids nocturnal hypoglycemia and severe hypoglycemia. A Brazilian woman developed type 1 diabetes at age 11 and was treated with multiple daily insulin injections. At age 20, she was admitted to our internal medicine department for her first pregnancy. Her HbA1c was 7.9% in the 6 weeks of gestation. Although the combination of continuous subcutaneous insulin infusion and a sensor-augmented pump was introduced, she had a miscarriage in the next week. After 6 months, she became pregnant again. Despite an HbA1c of 7.2%, she had another miscarriage. Thereafter, she returned to multiple daily insulin injections and began using intermittently scanned continuous glycemic monitoring. At age 22, she had her third pregnancy. Her HbA1c was 7.3%. SAP-PLGS was then introduced, which reduced her frequent hypoglycemic events and blood glucose fluctuations. She gave birth to a 4137 g boy at 39 weeks without significant complications. Successful delivery can be obtained in women with type 1 diabetes following repeated miscarriages after introducing SAP-PLGS. We hypothesize that the modality might contributed to our patient's miscarriage avoidance by reducing her glycemic fluctuations.

SELECTION OF CITATIONS
SEARCH DETAIL
...