1.
J Cardiovasc Electrophysiol ; 35(1): 7-15, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37794818

ABSTRACT

INTRODUCTION: High-power short-duration (HPSD) ablation at 50 W, guided by ablation index (AI) or lesion size index (LSI), and a 90 W/4 s very HSPD (vHPSD) setting are available for atrial fibrillation (AF) treatment. Yet, tissue temperatures during ablation with different catheters around venoatrial junction and collateral tissues remain unclear. METHODS: In this porcine study, we surgically implanted thermocouples on the epicardium near the superior vena cava (SVC), right pulmonary vein, and esophagus close to the inferior vena cava. We then compared tissue temperatures during 50W-HPSD guided by AI 400 or LSI 5.0, and 90 W/4 s-vHPSD ablation using THERMOCOOL SMARTTOUCH SF (STSF), TactiCath ablation catheter, sensor enabled (TacthCath), and QDOT MICRO (Qmode and Qmode+ settings) catheters. RESULTS: STSF produced the highest maximum tissue temperature (Tmax ), followed by TactiCath, and QDOT MICRO in Qmode and Qmode+ (62.7 ± 12.5°C, 58.0 ± 10.1°C, 50.0 ± 12.1°C, and 49.2 ± 8.4°C, respectively; p = .005), achieving effective transmural lesions. Time to lethal tissue temperature ≥50°C (t-T ≥ 50°C) was fastest in Qmode+, followed by TacthCath, STSF, and Qmode (4.3 ± 2.5, 6.4 ± 1.9, 7.1 ± 2.8, and 7.7 ± 3.1 s, respectively; p < .001). The catheter tip-to-thermocouple distance for lethal temperature (indicating lesion depth) from receiver operating characteristic curve analysis was deepest in STSF at 5.2 mm, followed by Qmode at 4.3 mm, Qmode+ at 3.1 mm, and TactiCath at 2.8 mm. Ablation at the SVC near the phrenic nerve led to sudden injury at t-T ≥ 50°C in all four settings. The esophageal adventitia injury was least deep with Qmode+ ablation (0.4 ± 0.1 vs. 0.8 ± 0.4 mm for Qmode, 0.9 ± 0.3 mm for TactiCath, and 1.1 ± 0.5 mm for STSF, respectively; p = .005), correlating with Tmax . CONCLUSION: This study revealed distinct tissue temperature patterns during HSPD and vHPSD ablations with the three catheters, affecting lesion effectiveness and collateral damage based on Tmax and/or t-T ≥ 50°C. These findings provide key insights into the safety and efficacy of AF ablation with these four settings.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Swine , Animals , Temperature , Vena Cava, Superior/surgery , Catheters , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Hot Temperature , Catheter Ablation/adverse effects , Pulmonary Veins/surgery , Treatment Outcome
3.
Int Heart J ; 64(3): 358-364, 2023 May 31.
Article in English | MEDLINE | ID: mdl-37197920

ABSTRACT

One benefit of an implantable cardioverter-defibrillator is the prevention of sudden cardiac death (SCD). It is recommended for patients with a low left ventricular ejection fraction (LVEF). However, the choice of cardiac resynchronization therapy (CRT) with or without a defibrillator (CRT-D and CRT-P) in elderly patients is controversial. To understand the current situation for proper device selection, we investigated the impact of defibrillators on mortality in elderly patients with heart failure.Consecutive patients who underwent CRT implantation were retrospectively recruited. Baseline characteristics, all-cause mortality, cardiac death, and defibrillator implantation rates were investigated in patients aged > 75 or ≤ 75 years.A total of 285 patients (79 patients aged > 75 years) were analyzed. Elderly patients had more comorbidities, but a lower proportion had ventricular arrhythmia. During the mean follow-up of 47 months, 109 patients died (67 due to cardiac death). Kaplan-Meier analysis showed higher mortality in elderly patients (P = 0.0428) but no significant difference in cardiac death by age group (P = 0.7472). There were no significant differences in mortality between patients with CRT-D versus CRT-P (P = 0.3386).SCD was rare. A defibrillator had no significant impact on mortality. In elderly patients, comorbidities are common and related to mortality. The selection of CRT-D versus CRT-P should take those factors into account.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Aged , Humans , Stroke Volume , Retrospective Studies , Ventricular Function, Left , Heart Failure/complications , Heart Failure/therapy , Death , Treatment Outcome , Risk Factors
4.
J Cardiovasc Electrophysiol ; 34(2): 369-378, 2023 02.
Article in English | MEDLINE | ID: mdl-36527433

ABSTRACT

INTRODUCTION: Neither the actual in vivo tissue temperatures reached with 90 W/4 s-very high-power short-duration (vHPSD) ablation for atrial fibrillation nor the safety and efficacy profile have been fully elucidated. METHODS: We conducted a porcine study (n = 15) in which, after right thoracotomy, we implanted 6-8 thermocouples epicardially in the superior vena cava, right pulmonary vein, and esophagus close to the inferior vena cava. We compared tissue temperatures close to a QDOT MICRO catheter, between during 90 W/4 s-vHPSD ablation during ablation index (AI: target 400)-guided 50 W-HPSD ablation, both targeting a contact force of 8-15 g. RESULTS: Maximum tissue temperature reached during 90 W/4 s-vHPSD ablation did not differ significantly from that during 50 W-HPSD ablation (49.2 ± 8.4°C vs. 50.0 ± 12.1°C; p = .69) and correlated inversely with distance between the catheter tip and the thermocouple, regardless of the power settings (r = -0.52 and r = -0.37). Lethal temperature (≥50°C) was best predicted at a catheter tip-to-thermocouple distance cut-point of 3.13 and 4.27 mm, respectively. All lesions produced by 90 W/4 s-vHPSD or 50 W-HPSD ablation were transmural. Although there was no difference in the esophageal injury rate (50% vs. 66%, p = .80), the thermal lesion was significantly shallower with 90 W/4 s-vHPSD ablation than with 50W-HPSD ablation (381.3 ± 127.3 vs. 820.0 ± 426.1 µm from the esophageal adventitia; p = .039). CONCLUSION: Actual tissue temperatures reached with 90 W/4 s-vHPSD ablation appear similar to those with AI-guided 50 W-HPSD ablation, with the distance between the catheter tip and target tissue being shorter for the former. Although both ablation settings may create transmural lesions in thin atrial tissues, any resulting esophageal thermal lesions appear shallower with 90 W/4 s-vHPSD ablation.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Animals , Swine , Temperature , Catheter Ablation/adverse effects , Catheter Ablation/methods , Vena Cava, Superior , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Esophagus/surgery , Esophagus/injuries , Pulmonary Veins/surgery , Treatment Outcome
5.
J Cardiovasc Electrophysiol ; 34(1): 108-116, 2023 01.
Article in English | MEDLINE | ID: mdl-36300696

ABSTRACT

BACKGROUND: Neither the actual in vivo tissue temperatures reached with lesion size index (LSI)-guided high-power short-duration (HPSD) ablation for atrial fibrillation nor the safety profile has been elucidated. METHODS: We conducted a porcine study (n = 7) in which, after right thoracotomy, we implanted 6-8 thermocouples epicardially in the superior vena cava, right pulmonary vein, and esophagus close to the inferior vena cava. We compared tissue temperatures reached during 50 W-HPSD ablation with those reached during standard (30 W) ablation, both targeting an LSI of 5.0 (5-15 g contact force). RESULTS: Tmax  (maximum tissue temperature when the thermocouple was located ≤5 mm from the catheter tip) reached during HPSD ablation was modestly higher than that reached during standard ablation (58.0 ± 10.1°C vs. 53.6 ± 9.2°C; p = .14) and peak tissue temperature correlated inversely with the distance between the catheter tip and the thermocouple, regardless of the power settings (HPSD: r = -0.63; standard: r = -0.66). Lethal temperature (≥50°C) reached 6.3 ± 1.8 s and 16.9 ± 16.1 s after the start of HPSD and standard ablation, respectively (p = .002), and it was best predicted at a catheter tip-to-thermocouple distance cut point of 2.8 and 5.3 mm, respectively. All lesions produced by HPSD ablation and by standard ablation were transmural. There was no difference between HPSD ablation and standard ablation in the esophageal injury rate (70% vs. 75%, p = .81), but the maximum distance from the esophageal adventitia to the injury site tended to be shorter (0.94 ± 0.29 mm vs. 1.40 ± 0.57 mm, respectively; p = .09). CONCLUSIONS: Actual tissue temperatures reached with LSI-guided HPSD ablation appear to be modestly higher, with a shorter distance between the catheter tip and thermocouple achieving lethal temperature, than those reached with standard ablation. HPSD ablation lasting <6 s may help minimize lethal thermal injury to the esophagus lying at a close distance.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Swine , Animals , Temperature , Vena Cava, Superior , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Esophagus/surgery , Esophagus/injuries , Catheters , Catheter Ablation/adverse effects , Pulmonary Veins/surgery , Treatment Outcome
6.
Int Heart J ; 63(2): 393-397, 2022 Mar 30.
Article in English | MEDLINE | ID: mdl-35296616

ABSTRACT

Sleep apnea syndrome (SAS) is a condition in which apnea and hypoventilation at night cause hypoxemia and impaired wakefulness during the day, resulting in a general malaise and dozing. Sleep apnea has been implicated in the development of hypertension, ischemic heart disease, arrhythmia, heart failure, and cerebrovascular disease.1) Approximately 50% of patients with sleep-disordered breathing have an arrhythmia. In severe cases with an apnea-hypopnea index (AHI) of 30 or more, the frequency of arrhythmias during sleep is two to four times that of individuals without SAS. Bradyarrhythmias such as sinus bradycardia, sinus arrest, and atrioventricular block occurs at night in about 5%-10% of patients with sleep-disordered breathing.2)During nocturnal sleep, vagal excitation causes excessive muscle relaxation of the upper airway, leading to periodic airway diameter reduction, which increases snoring and obstructive apnea. As a result, hypoxemia is likely, further increasing vagal tone and leading to bradycardia. An increase in ventilation rate and volume quickly compensates for the decrease in arterial partial pressure of oxygen during apnea, which leads to new bradycardia due to a decrease in the partial pressure of oxygen in arterial blood, which suppresses vagal tone and respiration.3)We experienced a case of a 44-year-old patient with bradyarrhythmia that might be associated with SAS. After continuous positive airway pressure treatment, AHI decreased, and very long cardiac arrests resolved.


Subject(s)
Heart Failure , Sleep Apnea Syndromes , Sleep Apnea, Obstructive , Adult , Arrhythmias, Cardiac/complications , Bradycardia/diagnosis , Bradycardia/etiology , Bradycardia/therapy , Humans , Sleep Apnea Syndromes/complications , Sleep Apnea Syndromes/diagnosis , Sleep Apnea, Obstructive/complications , Sleep Apnea, Obstructive/diagnosis , Sleep Apnea, Obstructive/therapy
7.
Heart Vessels ; 37(8): 1411-1417, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35133499

ABSTRACT

Some patients with pacemakers present with first-degree atrioventricular (AV) block. To avoid right ventricular (RV) pacing, preserving intrinsic AV conduction as much as possible is recommended. However, there is no clear cutoff AV interval to determine whether intrinsic AV conduction should be preserved or RV pacing should be delivered. This study aimed to compare a pacing mode-preserving, intrinsic AV conduction with the DDD mode delivering RV pacing in terms of echocardiographic parameters in patients with first-degree AV block and to investigate whether RV pacing induces heart failure (HF). Stroke volume (SV) was measured to determine the optimal AV delay with the intrinsic AV conduction rhythm and the DDD pacing delivering RV pacing. Echocardiographic evaluation was performed for 6-month follow-up period. Seventeen patients were studied. At baseline, mean intrinsic PQ interval was 250 ± 40 ms. SV was greater with RV pacing with optimal AV delay of 160 ms than with intrinsic AV conduction rhythm in all patients. Therefore, pacemakers were set to the DDD to deliver RV pacing. During follow-up, seven patients developed HF. Mean baseline E/E' ratio in patients who developed HF (HF group) during RV pacing was higher than in patients without HF (non = HF group; 17.9 ± 8 versus 11.5 ± 2, P = 0.018) Even within HF group patients without a high baseline E/E' ratio, it increased with RV pacing (22.2 ± 6 versus 11.6 ± 2; P < 0.001). In patients with pacemaker and first-degree AV block, RV pacing with the optimal AV delay of 160 ms increased SV. However, the risk of HF may be increased with RV pacing if the E/E' ratio is > 15 during intrinsic AV conduction or RV pacing. RV pacing should be avoided in patients with high E/E' ratio under intrinsic AV conduction or RV pacing.


Subject(s)
Atrioventricular Block , Heart Failure , Pacemaker, Artificial , Atrioventricular Block/diagnosis , Atrioventricular Block/therapy , Cardiac Pacing, Artificial , Heart Failure/diagnosis , Heart Failure/therapy , Heart Ventricles , Humans , Stroke Volume
8.
ESC Heart Fail ; 9(2): 1080-1089, 2022 04.
Article in English | MEDLINE | ID: mdl-34983080

ABSTRACT

AIMS: Multi-organ dysfunction was recently reported to be a common condition in patients with heart failure (HF). The Model for End-stage Liver Disease eXcluding International normalized ratio (MELD-XI) score reflects liver and kidney function. The prognostic relevance of this score has been reported in patients with a variety of cardiovascular diseases who are undergoing interventional therapies. However, the relationship between the severity of hepatorenal dysfunction assessed by the MELD-XI score and the long-term clinical outcomes of HF patients receiving cardiac resynchronization therapy (CRT) has not been evaluated. METHODS AND RESULTS: Clinical records of 283 patients who underwent CRT implantation between March 2003 and October 2020 were retrospectively evaluated (mean age 67 ± 12, 22.6% female). Blood samples were collected before CRT implantation. Patients were divided into three groups based on tertiles of the MELD-XI score: first tertile (MELD-XI = 9.44, n = 95), second tertile (9.44 < MELD-XI < 13.4, n = 94), and third tertile (MELD-XI ≥ 13.4, n = 94). The primary endpoint was all-cause mortality. Compared with the other groups, the third tertile group exhibited significantly older age, higher prevalence of diabetes mellitus and hypertension, lower haemoglobin level, and higher N-terminal pro-brain natriuretic peptide level (all P < 0.05). The functional CRT response rate was also significantly lower in the third tertile group (P = 0.011). During a median follow-up of 30 months (inter-quartile range, 9-67), 105 patients (37.1%) died. Kaplan-Meier analysis revealed that patients with a higher MELD-XI score had a greater risk of all-cause mortality (log-rank test: P < 0.001). Even after adjustment for clinically relevant factors and a conventional risk score, the MELD-XI score was still associated with mortality (adjusted hazard ratio: 1.04, 95% confidence interval: 1.00-1.07, P = 0.014, and adjusted hazard ratio: 1.04, 95% confidence interval: 1.01-1.09, P = 0.005, respectively). A higher MELD-XI score was associated with a greater risk of all-cause mortality than a lower MELD-XI score regardless of whether a pacemaker or defibrillator was implanted (log-rank test: P = 0.010 and P < 0.001, respectively). CONCLUSIONS: Impaired hepatorenal function assessed by the MELD-XI score was associated with older age, higher prevalence of multiple co-morbidities, severity of HF, lower CRT response rates, and subsequent all-cause mortality in HF patients undergoing CRT implantation. These results suggest that the MELD-XI score can provide additional prognostic information and may be useful for improving risk stratification in this population.


Subject(s)
Cardiac Resynchronization Therapy , End Stage Liver Disease , End Stage Liver Disease/therapy , Female , Humans , Male , Prognosis , Retrospective Studies , Severity of Illness Index
9.
Heart Vessels ; 37(7): 1136-1145, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35066673

ABSTRACT

Despite emerging recognition of interactions between heart failure (HF) and liver dysfunction, the impact of cardiac hepatopathy on patients with HF undergoing cardiac resynchronization therapy (CRT) has not been fully elucidated. Albumin-bilirubin (ALBI) score is a new assessment of liver function. The relationship between liver dysfunction severity based on ALBI score and clinical outcomes of patients with HF receiving CRT is unclear. Clinical records of 274 patients who underwent CRT device implantation between March 2003 and October 2020 were retrospectively investigated. ALBI score was calculated based on serum albumin and total bilirubin levels obtained before CRT device implantation. Patients were divided into three groups based on ALBI score: first tertile (ALBI ≤ - 2.62, n = 91)), second tertile (- 2.62 < ALBI < - 2.13, n = 92), and third tertile (ALBI ≥ - 2.13, n = 91). The study endpoint was all-cause mortality. The third tertile group had more advanced NYHA functional class, lower hemoglobin levels, and higher total bilirubin, aspartate aminotransferase, γ-glutamyl transferase, and N-terminal Pro-B-type natriuretic peptide levels (all p < 0.05). The third tertile group also had a higher prevalence of moderate or severe tricuspid regurgitation and higher tricuspid regurgitation pressure gradient (all p < 0.05). CRT response rates were significantly lower in the third tertile group. During a median (interquartile range) follow-up of 30 (9-60) months, 104 (37.9%) patients died. The third tertile group had significantly higher rates of all-cause mortality (log-rank p < 0.001). Higher ALBI score was significantly associated with all-cause mortality, even after adjusting for clinically relevant factors, a conventional validated risk score, and echocardiographic parameters related to right HF (all p < 0.01). Higher ALBI score before CRT device implantation is associated with HF severity, hepatic congestion and impairment due to right HF, lower CRT response, and higher all-cause mortality in CRT recipients.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Tricuspid Valve Insufficiency , Bilirubin , Cardiac Resynchronization Therapy/adverse effects , Heart Failure/complications , Heart Failure/diagnosis , Heart Failure/therapy , Humans , Prognosis , Retrospective Studies , Serum Albumin , Tricuspid Valve Insufficiency/complications
10.
J Cardiovasc Electrophysiol ; 33(1): 55-63, 2022 01.
Article in English | MEDLINE | ID: mdl-34713525

ABSTRACT

BACKGROUND: Actual in vivo tissue temperatures and the safety profile during high-power short-duration (HPSD) ablation of atrial fibrillation have not been clarified. METHODS: We conducted an animal study in which, after a right thoracotomy, we implanted 6-8 thermocouples epicardially in the superior vena cava, right pulmonary vein, and esophagus close to the inferior vena cava. We recorded tissue temperatures during a 50 W-HPSD ablation and 30 W-standard ablation targeting an ablation index (AI) of 400 (5-15 g contact force). RESULTS: Maximum tissue temperatures reached with HSPD ablation were significantly higher than that reached with standard ablation (62.7 ± 12.5 vs. 52.7 ± 11.4°C, p = 0.033) and correlated inversely with the distance between the catheter tip and thermocouple, regardless of the power settings (HPSD: r = -0.71; standard: r = -0.64). Achievement of lethal temperatures (≥50°C) was within 7.6 ± 3.6 and 12.1 ± 4.1 s after HPSD and standard ablation, respectively (p = 0.003), and was best predicted at cutoff points of 5.2 and 4.4 mm, respectively. All HPSD ablation lesions were transmural, but 19.2% of the standard ablation lesions were not (p = 0.011). There was no difference between HPSD and standard ablation regarding the esophageal injury rate (30% vs. 33.3%, p > 0.99), with the injury appearing to be related to the short distance from the catheter tip. CONCLUSIONS: Actual tissue temperatures reached with AI-guided HPSD ablation appeared to be higher with a greater distance between the catheter tip and target tissue than those with standard ablation. HPSD ablation for <7 s may help prevent collateral tissue injury when ablating within a close distance.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Animals , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Pulmonary Veins/surgery , Temperature , Treatment Outcome , Vena Cava, Superior/surgery
11.
J Interv Card Electrophysiol ; 63(1): 39-47, 2022 Jan.
Article in English | MEDLINE | ID: mdl-33515142

ABSTRACT

PURPOSE: Entrainment is a useful method for locating reentrant atrial tachycardia (AT) circuits, but alterations or termination of the AT can derail this process. We assessed whether resetting an upstream site of a neighboring electrode by a scanned extrastimulus at a downstream site (when the upstream tissue was refractory) could diagnose that site within the AT circuit. METHODS: The procedure was applied to 48 ATs with a cycle length (CL) of 238 ± 42 ms (26 common flutters, 8 perimitral flutters, 7 left atrial [LA] roof-dependent AT, 3 LA scar-related macroreentrant ATs, 2 pulmonary vein-gap reentry tachycardias, 1 right atrial scar-related macroreentrant AT, and 1 with an unidentified circuit). Entrainment and scanned extrastimulation were attempted at the cavotricuspid isthmus, LA roof, and mitral isthmus and/or critical AT isthmus. RESULTS: Within the circuit, the post-pacing interval minus the ATCL after entrainment was < 30 ms for all ATs and resetting of the AT cycle by ≥ 5 ms occurred in 94% of the ATs. No ATs were reset by extrastimulation outside the circuit. The positive predictive value of both maneuvers for locating the circuit was 100%, and the negative predictive value of the extrastimulation was similar to that of entrainment (96% vs. 100%, P = 0.25). The incidence of an AT alteration was lower with extrastimulation than with entrainment (1% vs. 9%, P = 0.01). For ATs with a CL < 210 ms, extrastimulation yielded a good diagnostic performance without any AT alterations. CONCLUSION: AT resetting by a scanned extrastimulus is diagnostic and avoids AT alterations.


Subject(s)
Catheter Ablation , Tachycardia, Supraventricular , Catheters , Heart Atria/surgery , Humans , Tachycardia , Tachycardia, Supraventricular/diagnostic imaging , Tachycardia, Supraventricular/surgery
12.
J Cardiol ; 79(3): 352-357, 2022 03.
Article in English | MEDLINE | ID: mdl-34799216

ABSTRACT

Cardiac resynchronization therapy (CRT) has been established as a standard treatment for heart failure. The effectiveness of CRT has been shown in many clinical trials and realized in actual clinical practice. Nevertheless, underutilization of CRT is a major problem in the treatment of heart failure. One factor leading to underutilization is the existence of CRT non-responders. CRT non-response has been discussed for approximately 20 years, since CRT was introduced. Since the beginning, the CRT non-response rate has been reported to be 30%. However, we are now undergoing a major transformation in the thinking about CRT response. First, heart failure is a progressive disease. Like many medications for heart failure, CRT does not cure the underlying disease of heart failure. Considering the natural course of heart failure, it is easy to understand that there will definitely be non-responders. There might have been misunderstandings about how to determine CRT response. Although CRT is a treatment for heart failure, it does not cure heart failure or myocardial tissue damage. Instead, by correcting conduction disorders and dyssynchrony, it modifies factors that exacerbate heart failure, which contributes to improvement. In addition, it is important to realize that pacing is the only treatment for correcting conduction disorders. Thus, in theory, CRT is an essential treatment for heart failure at any stage, regardless of severity, when it is accompanied by conduction disorder. Here, we consider the current state of CRT and the causes of underutilization. Returning to the origin of CRT, reconsidering the effects of CRT and the thinking about response, and spreading a new way of thinking will lead to the proper utilization of CRT.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Heart Failure/therapy , Humans , Treatment Outcome
13.
Open Heart ; 8(2)2021 10.
Article in English | MEDLINE | ID: mdl-34711651

ABSTRACT

AIMS: Malnutrition is common and associated with worse clinical outcomes in patients with heart failure (HF). The Controlling Nutritional Status (CONUT) score is an integrated index for evaluating diverse aspects of the complex mechanism of malnutrition. However, the relationship between the severity of malnutrition assessed by the CONUT score and clinical outcomes of HF patients receiving cardiac resynchronisation therapy (CRT) has not been fully clarified. METHODS: Clinical records of 263 patients who underwent pacemaker or defibrillator implantation for CRT between March 2003 and October 2020 were retrospectively evaluated. The CONUT score was calculated from laboratory data obtained before CRT device implantation. Patients were divided into three groups: normal nutrition (CONUT scores 0-1, n=58), mild malnutrition (CONUT scores 2-4, n=132) and moderate or severe malnutrition (CONUT scores 5-12, n=73). The primary endpoint was all-cause mortality. RESULTS: The moderate or severe malnutrition group had a lower body mass index, more advanced New York Heart Association functional class, higher Clinical Frailty Scale score, lower levels of haemoglobin and higher levels of N-terminal probrain natriuretic peptide (all p<0.05). In the moderate or severe malnutrition group, the CRT response rate was significantly lower than for the other two groups (p=0.001). During a median follow-up period of 31 (10-67) months, 103 (39.1%) patients died. Kaplan-Meier analysis revealed that the moderate or severe malnutrition group had a significantly higher mortality rate (log-rank p<0.001). A higher CONUT score and CONUT score ≥5 remained significantly associated with all-cause mortality after adjusting for previously reported clinically relevant factors and the conventional risk score (VALID-CRT risk score) (all p<0.05). CONCLUSIONS: A higher CONUT score before CRT device implantation was strongly associated with HF severity, frailty, lower CRT response rate and subsequent long-term all-cause mortality.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure/therapy , Malnutrition/therapy , Nutrition Assessment , Nutritional Status , Aged , Cause of Death/trends , Female , Follow-Up Studies , Heart Failure/complications , Heart Failure/epidemiology , Humans , Incidence , Japan/epidemiology , Male , Malnutrition/etiology , Malnutrition/mortality , Middle Aged , Prognosis , Retrospective Studies
14.
Intern Med ; 60(12): 1813-1818, 2021.
Article in English | MEDLINE | ID: mdl-34135267

ABSTRACT

Objective Following the introduction of magnetic resonance (MR)-conditional cardiac implantable electrical devices (CIEDs), patients with CIEDs have undergone MRI scanning more frequently. As the required settings of MRI equipment for scanning patients with a CIED vary by device, a number of precautions should be taken to allow safe examinations, including the confirmation of conditions and selection of MRI modes appropriate for pacing status in individual patients. In this study, we examined the current status and issues concerning the performance of MRI examinations in patients with an MRI-conditional CIED. Method and Results We reviewed a total of 262 MRI scans. The most common site of MRI scanning was the head, followed by the spine, abdomen, and heart in order. Regarding the MRI mode, DOO was most often used, followed by OFF, AOO, and finally VOO mode, to maintain atrioventricular synchrony. Although no obvious adverse events were observed related to MRI scanning, there were several cases encountered that might have been predisposed to a significant incident or in which the patient's intrinsic pulse rates or subjective symptoms changed before and during scanning. Conclusion As MRI is a very useful diagnostic tool for cerebrovascular diseases and orthopedic disorders, the demand for MRI scanning is high when treating these areas. Although MRI scanning in patients with MR-conditional devices was performed without any adverse events, there were incidents that could have potentially led to major harm. This highlights the importance of confirming the appropriate MRI mode is being used before scanning and monitoring patients during scanning.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Defibrillators, Implantable/adverse effects , Heart , Humans , Magnetic Resonance Imaging/adverse effects , Magnetic Resonance Spectroscopy
16.
Pacing Clin Electrophysiol ; 44(4): 693-702, 2021 04.
Article in English | MEDLINE | ID: mdl-33595100

ABSTRACT

BACKGROUND: A novel steerable sheath visualized on a three-dimensional mapping system has become available in this era in which a durable pulmonary vein (PV) isolation (PVI) with reduced fluoroscopy is required. METHODS: In 60 patients who underwent a PVI with a visualized sheath (n = 30) and non-visualized conventional sheath (n = 30), the fluoroscopic time and catheter stability during the PVI were analyzed. RESULTS: The fluoroscopic time during the transseptal access (0 [0, 0.1] vs. 1.4 [0.8, 2.3] minutes, P < .001) and PVI (0 [0, 0.1] vs. 0.4 [0.2, 1.1] minutes, P < .001) were shorter in the visualized sheath group than conventional sheath group. The procedure time during the PVI (32.0 [26.8, 36.3] vs. 41.0 [31.8, 47.3] minutes, P = .01), particularly during the right PVI (15.0 [12.8, 18.0] vs. 23.0 [15.8, 26.3] minutes, P = .009), was shorter in the visualized sheath group than conventional sheath group, however, that during the other steps was equivalent. The standard deviation of the catheter contact force during each radiofrequency application was smaller in the visualized sheath group than conventional sheath group (4.5 ± 2.7 vs. 4.9 ± 3.1 g, P = .001). The impedance drop for each lesion was larger in the visualized sheath group than conventional sheath group (10.7 ± 6.5 vs. 9.8 ± 5.5 ohms, P < .001). The incidence of acute PV reconnections per patient (30% vs. 23%, P = .56) and per PV segment (2.5% vs. 2.3%, P = .83) were similar between the two groups. No major complications occurred in either sheath group. CONCLUSIONS: The use of visualized sheaths may reduce the fluoroscopic time and improve the catheter stability during the PVI.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation , Imaging, Three-Dimensional , Pulmonary Veins/surgery , Ultrasonography, Interventional , Aged , Atrial Fibrillation/diagnostic imaging , Epicardial Mapping , Female , Fluoroscopy , Humans , Male , Middle Aged , Pulmonary Veins/diagnostic imaging , Time Factors
17.
J Clin Med ; 10(3)2021 Feb 01.
Article in English | MEDLINE | ID: mdl-33535633

ABSTRACT

BACKGROUND: The definition of response to cardiac resynchronization therapy (CRT) varies across clinical trials. There are two main definitions, i.e., echocardiographic response and functional response. We assessed which definition was more reasonable. METHODS: In this study of 260 patients who had undergone CRT, an echocardiographic response was defined as a reduction in a left ventricular end-systolic volume of greater than or equal to 15% or an improvement in left ventricular ejection fraction of greater than or equal to 5%. A functional response was defined as an improvement of at least one class category in the New York Heart Association functional classification. We assessed the response to CRT at 6 months after device implantation, based on each definition, and investigated the relationship between response and clinical outcomes. RESULTS: The echocardiographic response rate was 74.2%. The functional response rate was 86.9%. Non-responder status, based on both definitions, was associated with higher all-cause mortality. Cardiac death was only associated with functional non-responder status (hazard ratio (HR) 2.65, 95% confidence interval (CI) 1.19-5.46, p = 0.0186) and heart failure hospitalization (HR 2.78, 95% CI, 1.29-5.26, p = 0.0111). CONCLUSION: After CRT implantation, the functional response definition of CRT response is associated with a higher response rate and better clinical outcomes than that of the echocardiographic response definition, and therefore it is reasonable to use the functional definition to assess CRT response.

18.
J Cardiovasc Electrophysiol ; 32(4): 889-899, 2021 04.
Article in English | MEDLINE | ID: mdl-33600010

ABSTRACT

BACKGROUND: How obesity and epicardial fat influence atrial fibrillation (AF) is unknown. METHODS: To investigate the effect of obesity/epicardial fat on the AF substrate, we divided 20 beagle dogs of normal weight into four groups (n = 5 each): one of the four groups (Obese-rapid atrial pacing [RAP] group) served as a novel canine model of obesity and AF. The other three groups comprised dogs fed a standard diet without RAP (Control group), dogs fed a high-fat diet without RAP (Obese group), or dogs fed a standard diet with RAP (RAP group). All underwent electrophysiology study, and hearts were excised for histopathologic and fibrosis-related gene expression analyses. RESULTS: Left atrial (LA) pressure was significantly higher in the Obese group than in the Control, RAP, and Obese-RAP groups (23.4 ± 6.9 vs. 11.4 ± 2.1, 11.9 ± 6.4, and 13.5 ± 2.9 mmHg; p = .005). The effective refractory period of the inferior PV was significantly shorter in the RAP and Obese-RAP groups than in the Control group (p = .043). Short-duration AF was induced at greatest frequency in the Obese-RAP and Obese groups (p < .05). Epicardial fat/Fatty infiltration was greatest in the Obese-RAP group, and greater in the Obese and RAP groups than in the Control group. %interstitial fibrosis/fibrosis-related gene expression was significantly greater in the Obese-RAP and RAP groups (p < .05). CONCLUSIONS: Vulnerability to AF was associated with increased LA pressure and increased epicardial fat/fatty infiltration in our Obese group, and with increased epicardial fat/fibrofatty infiltration in the RAP and Obese-RAP groups. These may explain the role of obesity/epicardial fat in the pathogenesis of AF.


Subject(s)
Atrial Fibrillation , Atrial Remodeling , Adipose Tissue , Animals , Atrial Fibrillation/etiology , Disease Models, Animal , Dogs , Heart Atria , Obesity/complications , Pericardium
20.
Heart Vessels ; 35(12): 1699-1708, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32591893

ABSTRACT

The renal arterial resistance index (RI) and the brachial-ankle pulse wave velocity (baPWV) are known as indicators of renal vascular resistance/systemic vascular damage and systemic arterial stiffness. The clinical significance of those parameters on clinical outcomes is poorly known in patients with and without heart failure with preserved ejection fraction (HFpEF). Baseline clinical data and the RI assessed by renal Doppler data, baPWV were obtained in patients with (HFpEF group, n = 60) and without HFpEF (non-HFpEF group, n = 51) who had a reduced estimated glomerular filtration rate (eGFR) of > 30 and < 60 mL/min/1.73 m2). We investigated the association between the RI and baPWV and major clinical outcomes including hospitalization for heart failure, cardiovascular death, myocardial infarction or unstable angina or other cardiovascular events and death from another cause. The RI and baPWV were greater in the HFpEF group than in the non-HF group (0.75 ± 0.07 vs. 0.69 ± 0.08, p < 0.001; 2002 ± 430 vs. 1762 ± 300 cm/s, p = 0.001). The RI correlated significantly with baPWV in the HFpEF (r = 0.382, p = 0.003) and non-HFpEF groups (r = 0.414, p = 0.002). During the median follow-up period of 54 months, major clinical outcomes occurred in 41 (36.9%) patients. The RI value, statin use and the presence of HFpEF were major factors for predicting clinical outcomes by multivariate analysis. Among the patients who had mild-to-moderate renal dysfunction, an increased RI and baPWV were observed in HFpEF patients as compared to non-HFpEF patients, but the baPWV similarly correlated with the RI value regardless of HFpFE patients or not. The strong association between the high RI value and presence of HFpEF and major clinical outcomes, suggests that not only the presence of HFpEF but also the high RI value may help to identify the high-risk patients leading to poor clinical outcomes.


Subject(s)
Heart Failure/physiopathology , Kidney Diseases/physiopathology , Renal Circulation , Vascular Resistance , Vascular Stiffness , Aged , Aged, 80 and over , Ankle Brachial Index , Disease Progression , Female , Heart Disease Risk Factors , Heart Failure/diagnosis , Heart Failure/mortality , Heart Failure/therapy , Hospitalization , Humans , Kidney Diseases/diagnosis , Kidney Diseases/mortality , Kidney Diseases/therapy , Male , Middle Aged , Prognosis , Pulse Wave Analysis , Retrospective Studies , Risk Assessment , Ultrasonography, Doppler