Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters











Database
Language
Publication year range
1.
J Prosthodont ; 2023 Sep 28.
Article in English | MEDLINE | ID: mdl-37771238

ABSTRACT

PURPOSE: This study aimed to assess the bonding stability of three universal adhesives to a CAD-CAM feldspathic ceramic with or without prior silane application. MATERIALS AND METHODS: The universal adhesives tested were Ambar Universal (FGM), Single Bond Universal (3M), and Ybond Universal (Yller). Scotchbond Multipurpose Plus (3M) was used as a control. The silane used was RelyX Ceramic Primer (3M). Microtensile bond strength (µTBS) to Vitablocs Mark II was measured after 24 h or 6 months of water aging (n = 20). Failure modes were observed through scanning electron microscopy, and pH and degree of C=C conversion (DC) of the adhesives were measured (n = 3). Data were analyzed using one-, two-, and three-way ANOVA. RESULTS: The pH values differed significantly among the adhesives (p < 0.001), while the DC was similar (p = 0.141). The universal adhesives showed significant differences in µTBS, with higher immediate results when using silane and lower results after aging. Notably, a significant decrease in µTBS was observed after 6 months when silane was applied. In contrast, the control adhesive exhibited consistent results between the 24-h and 6-month storage periods. The universal adhesives showed a decrease in µTBS ranging from 25.5% to 40.1% after prolonged storage. Adhesive failures were predominant in all groups. The presence or absence of silane in the adhesive composition did not affect the bonding performance. CONCLUSIONS: The application of a separate silane coupling agent improved the immediate bond strength of universal adhesives to CAD-CAM feldspathic ceramic. However, this bond strength significantly decreased after 6 months of water aging. The bond strength remained stable for universal adhesives when applied without silane after 6 months of aging.

2.
Materials (Basel) ; 14(20)2021 Oct 15.
Article in English | MEDLINE | ID: mdl-34683722

ABSTRACT

Debonding of orthodontic brackets is a common occurrence during orthodontic treatment. Therefore, the best option for treating debonded brackets should be indicated. This study aimed to evaluate the bond strength of rebonded brackets after different residual adhesive removal methods. This systematic review and meta-analysis was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. PubMed, Web of Science, The Cochrane Library, SciELO, Scopus, LILACS, IBECS, and BVS databases were screened up to December 2020. Bond strength comparisons were made considering the method used for removing the residual adhesive on the bracket base. A total of 12 studies were included for the meta-analysis. Four different adhesive removal methods were identified: sandblasting, laser, mechanical grinding, and direct flame. When compared with new orthodontic metallic brackets, bond strength of debonded brackets after air abrasion (p = 0.006), mechanical grinding (p = 0.007), and direct flame (p < 0.001) was significantly lower. The use of an erbium-doped yttrium aluminum garnet (Er:YAG) laser showed similar shear bond strength (SBS) values when compared with those of new orthodontic brackets (p = 0.71). The Er:YAG laser could be considered an optimal method for promoting the bond of debonded orthodontic brackets. Direct flame, mechanical grinding, or sandblasting are also suitable, obtaining clinically acceptable bond strength values.

3.
Restor Dent Endod ; 46(3): e39, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34513645

ABSTRACT

OBJECTIVES: This study analyzed the physical-chemical behavior of 2 bulk fill resin composites (BFCs; Filtek Bulk Fill [FBF], and Tetric-N-Ceram Bulk Fill [TBF]) used in 2- and 4-mm increments and compared them with a conventional resin composite (Filtek Z250). MATERIALS AND METHODS: Flexural strength and elastic modulus were evaluated by using a 3-point bending test. Knoop hardness was measured at depth areas 0-1, 1-2, 2-3, and 3-4 mm. The translucency parameter was measured using an optical spectrophotometer. Real-time polymerization kinetics was analyzed using Fourier transform infrared spectroscopy. RESULTS: Flexural strength was similar among the materials, while TBF showed lower elastic modulus (Z250: 6.6 ± 1.3, FBF: 6.4 ± 0.9, TBF: 4.3 ± 1.3). The hardness of Z250 was similar only between 0-1 mm and 1-2 mm. Both BFCs had similar hardness until 2-3 mm, and showed significant decreases at 3-4 mm (FBF: 33.45 ± 1.95 at 0-1 mm to 23.19 ± 4.32 at 3-4 mm, TBF: 23.17 ± 2.51 at 0-1 mm to 15.11 ± 1.94 at 3-4 mm). The BFCs showed higher translucency than Z250. The polymerization kinetics of all the materials were similar at 2-mm increments. At 4-mm, only TBF had a similar degree of conversion compared with 2 mm. CONCLUSIONS: The BFCs tested had similar performance compared to the conventional composite when used in up to 2-mm increments. When the increment was thicker, the BFCs were properly polymerized only up to 3 mm.

4.
Dent Mater ; 36(10): 1314-1321, 2020 10.
Article in English | MEDLINE | ID: mdl-32758374

ABSTRACT

OBJECTIVE: Zirconia and alumina nanoparticles were coated with a silica-rich layer (ALSI and ZRSI) and used to prepare experimental nanohybrid resin composites, which were characterized and compared to a control commercial resin composite (Filtek Z350 XT). METHODS: Silica nanoparticles with sizes compatible to ALSI (Aerosil 150) and ZRSI (Aerosil OX 50) were tested as references. The volume of nanoparticles was equivalent across the composites, which also had consistent content of glass microparticles. CC conversion, viscosity, depth of cure, surface topography, hardness, opacity, radio-opacity, and edge chipping resistance (ReA) were tested after 24 h. Flexural strength (σf) and fracture toughness (KIC) were also tested after 15 K thermal cycles. Data were analyzed using one-way or two-way ANOVA and Tukey's test (α = 0.05). RESULTS: ALSI and ZRSI yielded resin composites with lower viscosity and more irregular nanoagglomerates compared to nanosilica-based composites. CC conversion and depth of cure were lower for ZRSI composite, which had higher opacity, radio-opacity, and hardness. ReA was higher for ALSI composite. Composites with ALSI and ZRSI showed stable σf after aging, whereas the control and Aerosil 150 resin composites showed significant degradation. The commercial and nanosilica-based composites showed up to 42% reduction in KIC after aging, whereas resin composites with ZRSI and ALSI showed a more stable KIC. SIGNIFICANCE: ALSI and ZRSI generated nanohybrid resin composites with improved and/or more stable physical properties compared with nanosilica-based and commercial composites. This study suggests that changing the composition of nanofillers is a simple method to enhance the performance of nanohybrid composites.


Subject(s)
Methacrylates , Nanoparticles , Composite Resins , Hardness , Materials Testing , Silicon Dioxide , Surface Properties
5.
Dent Mater J ; 39(2): 236-241, 2020 Mar 31.
Article in English | MEDLINE | ID: mdl-31723090

ABSTRACT

This study evaluated the effect of different adhesive protocols on the shear bond strength (SBS) of bulk-fill resin composite repaired with bulk-fill or conventional composite. Cylindrical bulk-fill resin composite specimens were prepared and allocated into groups according to the bonding strategy: no treatment, Silane+Scotch Bond Multipurpose (S+SBMP), Tetric N Bond Universal, and Single Bond Universal. Following bonding strategy, bulk-fill or conventional composite buildups were performed. After 24 h of storage in distilled water at 37°C, shear force was applied to the interface using a universal testing machine. The data were analyzed by two-way ANOVA and Tukey test (α=0.05). SBS was influenced by the bonding strategy and the composite used (p<0.001). Irrespective of the composite used, the group S+SBMP yielded the highest SBS values (p<0.001). Repair bond strength of bulk-fill composites can be improved by using a silane coupling agent followed by a hydrophobic resin.


Subject(s)
Dental Bonding , Dental Cements , Composite Resins , Materials Testing , Mechanical Phenomena , Resin Cements , Shear Strength , Silanes , Surface Properties
6.
Braz Dent J ; 30(5): 467-475, 2019.
Article in English | MEDLINE | ID: mdl-31596331

ABSTRACT

This study evaluated the immediate and 6-month dentin bond strength of universal adhesives used in etch-and-rinse or self-etch bonding strategies. The adhesives tested were Ambar Universal, G-Bond, Single Bond Universal, Tetric N-Bond Universal, and Ybond Universal. Gold standard adhesives (Scotchbond Multipurpose Plus and Clearfil SE Bond) were controls. Microtensile dentin bond strength (n=5 teeth), pH, and C=C conversion (n=3) were evaluated. Data were analyzed at α=0.05. All adhesives showed differences in pH. Ybond had intermediately strong aggressiveness, whereas the others were ultra-mild. The C=C conversion was different in most adhesives. In the etch-and-rinse strategy, all adhesives showed similar results generally except for G-Bond, which had lower bond strength than most adhesives. G-Bond and Tetric-N-Bond showed lower bond strengths after 6 months compared with 24 h, whereas the other adhesives had stable dentin bonds. In the self-etch strategy, G-Bond had lower bond strength than most adhesives. After 6 months, Ambar was the only adhesive showing lower dentin bond strength compared with 24 h. Most adhesives had discreet drops in bond strength during aging when used in the self-etch strategy. The failure modes were also material dependent, with a general pattern of increased adhesive and/or pre-testing failures after storage. In conclusion, the bonding performance of universal adhesives to dentin is material dependent. Most adhesives had stable dentin bonds with results comparable to the gold standard materials, particularly when applied in the self-etch mode. In general, it seems the use of universal adhesives in dentin should not be preceded by phosphoric acid etching.


Subject(s)
Dental Bonding , Dentin-Bonding Agents , Adhesives , Dental Cements , Dentin , Materials Testing , Resin Cements , Tensile Strength
SELECTION OF CITATIONS
SEARCH DETAIL