Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 71
Filter
1.
J Orthop Res ; 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38953239

ABSTRACT

Resonance frequency analysis (RFA) is valuable for assessing implant status. In a previous investigation, acetabular cup fixation was assessed using laser RFA and the pull-down force was predicted in an in vitro setting. While the pull-down force alone is sufficient for initial fixation evaluation, it is desirable to evaluate the bone strength of the foundation for subsequent fixation. Diminished bone quality causes micromotion, migration, and protracted osseointegration, consequently elevating susceptibility to periprosthetic fractures and failure of ingrained trabecular bone. Limited research exists on the evaluation of bone mineral density (BMD) around the cup using RFA. For in vivo application of laser RFA, we implemented the sweep pulse excitation method and engineered an innovative laser RFA device having low laser energy and small dimensions. We focused on a specific frequency range (2500-4500 Hz), where the peak frequency was presumed to be influenced by foundational density. Quantitative computed tomography with a phantom was employed to assess periprosthetic BMD. Correlation between the resonance frequency within the designated range and the density around the cup was evaluated both in the laboratory and in vivo using the novel laser RFA device. The Kruskal-Wallis test showed robust correlations in both experiments (laboratory study: R = 0.728, p < 0.001; in vivo study: R = 0.619, p < 0.001). Our laser RFA system can assess the quality of bone surrounding the cup. Laser RFA holds promise in predicting the risk of loosening and might aid in the decision-making process for additional fixation through screw insertion.

2.
Magn Reson Imaging ; 111: 9-14, 2024 Sep.
Article in English | MEDLINE | ID: mdl-38588961

ABSTRACT

PURPOSE: This study assessed the feasibility of using three-dimensional (3D) models of intrapelvic vascular patterns constructed using computed tomography (CT) and magnetic resonance imaging (MRI) fusion data for preoperative planning in patients with locally recurrent rectal cancer. METHODS: Eleven patients scheduled for pelvic exenteration were included. The 3D fusion data of the intrapelvic vessels constructed using CT and MRI with true fast imaging with steady-state precession sequence (True FISP) were evaluated preoperatively. Contrast ratios (CR) between the piriformis muscle and the intrapelvic vessels were calculated to identify a valid modality for 3D modeling and creating CT/MRI fusion-reconstructed volume-rendered images. RESULTS: The CR values of the internal and external iliac arteries were significantly higher on CT images than MR images (CT vs. MRI; 0.63 vs. 0.45, p < 0.01). However, the CR value of the internal iliac vein was significantly higher on MR than CT images (CT vs. MRI; 0.23 vs. 0.55, p < 0.01). CONCLUSIONS: MRI with True FISP yielded high signal-to-noise ratios and aided in delineating the internal iliac vein around the piriformis muscle. More precise 3D models can be constructed using this technique in the future to aid in the resection of locally recurrent rectal cancer.


Subject(s)
Iliac Vein , Imaging, Three-Dimensional , Magnetic Resonance Imaging , Neoplasm Recurrence, Local , Rectal Neoplasms , Tomography, X-Ray Computed , Humans , Rectal Neoplasms/diagnostic imaging , Rectal Neoplasms/surgery , Female , Pilot Projects , Middle Aged , Male , Iliac Vein/diagnostic imaging , Tomography, X-Ray Computed/methods , Neoplasm Recurrence, Local/diagnostic imaging , Aged , Magnetic Resonance Imaging/methods , Imaging, Three-Dimensional/methods , Adult , Multimodal Imaging/methods , Feasibility Studies , Reproducibility of Results
3.
Heliyon ; 10(4): e26391, 2024 Feb 29.
Article in English | MEDLINE | ID: mdl-38434080

ABSTRACT

In diffusion magnetic resonance imaging, oscillating gradient spin echo (OGSE) has an extremely short diffusion time if motion probing gradient (MPG) is applied to the waveform. Further, it can detect microstructural specificity. OGSE changes sensitivity to spin displacement velocity based on the MPG phase. The current study aimed to investigate the restricted diffusion characteristics of each OGSE waveform using the capillary phantom with various b-values, frequencies, and MPG phases. We performed OGSE (b-value = 300, 500, 800, 1200, 1600, and 2000 s/mm2) for the sine and cosine waveforms using the capillary phantom (6, 12, 25, 50, and 100 µm and free water) with a 9.4-T experimental magnetic resonance imaging system and a solenoid coil. We evaluated the axial and radial diffusivity (AD, RD) of each structure size. The output current of the MPG was assessed with an oscilloscope and analyzed with the gradient modulation power spectra by fast Fourier transform. In sine, the sidelobe spectrum was enhanced with increasing frequency, and the central spectrum slightly increased. The difference in RD was detected at 6 and 12 µm; however, it did not depend on the structure scale at 50 or 100 µm and free water. In cosine, the diffusion spectrum was enhanced, whereas the central spectrum decreased with increasing frequency. Both AD and RD in cosine had a frequency dependence, and AD and RD increased with a higher frequency regardless of structure size. AD and RD in either sine or cosine had no evident b-value dependence. We evaluated the OGSE-restricted diffusion characteristics. The measurements obtained diffusion information similar to the pulsed gradient spin echo. Hence, the cosine measurements indicated that a higher frequency could capture faster diffusion within the diffusion phenomena.

4.
J Physiol Anthropol ; 43(1): 11, 2024 Mar 25.
Article in English | MEDLINE | ID: mdl-38528599

ABSTRACT

BACKGROUND: Local alternating heat and cold stimulation as an alternative to contrast bath may cause intermittent vasoconstriction and vasodilation, inducing a vascular pumping effect and consequently promoting increased tissue blood flow and oxygenation. This study aimed to examine the effects of local alternating heat and cold stimulation, using a wearable thermal device, on the hemodynamics of fatigued muscle tissue and autonomic nervous activity. METHODS: Twenty healthy individuals experienced fatigue in the periarticular muscles of the shoulder joint due to a typing task. Local alternating heat and cold stimulations were then applied to the upper trapezius muscle. Muscle hardness was measured using a muscle hardness meter, and muscle tissue hemodynamics and oxygenation were evaluated using near-infrared spectroscopy before and after the stimulation. Autonomic nervous activity was also evaluated using heart rate variability. RESULTS: Alternating heat and cold stimulation decreased muscle hardness of the fatigued trapezius muscle from 1.38 ± 0.15 to 1.31 ± 0.14 N (P < 0.01). The concentration of total hemoglobin in the trapezius muscle tissue increased from - 0.21 ± 1.36 to 2.29 ± 3.42 µmol/l (P < 0.01), and the tissue hemoglobin oxygen saturation also increased from 70.1 ± 5.4 to 71.1 ± 6.0% (P < 0.05). Additionally, the heart rate variability parameter, which is an index of sympathetic nervous activity, increased from 3.82 ± 2.96 to 6.86 ± 3.49 (P < 0.01). A correlation was found between increased tissue hemoglobin oxygen saturation and increased parameters of sympathetic nervous activity (r = 0.50, P < 0.05). CONCLUSIONS: Local alternating heat and cold stimulation affected the hemodynamic response in fatigued muscle tissue and autonomic nervous activity. This stimulation is more efficient than conventional contrast baths in terms of mobility and temperature control and has potential as a new versatile therapeutic intervention for muscle fatigue. TRIAL REGISTRATION: UMIN-CTR (UMIN000040087: registered on April 7, 2020, https://upload.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000045710 . UMIN000040620: registered on June 1, 2020, https://upload.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000046359 ).


Subject(s)
Hemodynamics , Hot Temperature , Humans , Hemodynamics/physiology , Cold Temperature , Muscle, Skeletal/physiology , Hemoglobins
5.
Magn Reson Med Sci ; 23(2): 136-145, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-36754420

ABSTRACT

PURPOSE: Diffusion MRI is a physical measurement method that quantitatively indicates the displacement of water molecules diffusing in voxels. However, there are insufficient data to characterize the diffusion process physically in a uniform structure such as a phantom. This study investigated the transitional relationship between structure scale, temperature, and diffusion time for simple restricted diffusion using a capillary phantom. METHODS: We performed diffusion-weighted pulsed-gradient stimulated-echo acquisition mode (STEAM) MRI with a 9.4 Tesla MRI system (Bruker BioSpin, Ettlingen, Germany) and a quadrature coil with an inner diameter of 86 mm (Bruker BioSpin). We measured the diffusion coefficients (radial diffusivity [RD]) of capillary plates (pore sizes 6, 12, 25, 50, and 100 µm) with uniformly restricted structures at various temperatures (10ºC, 20ºC, 30ºC, and 40ºC) and multiple diffusion times (12-800 ms). We evaluated the characteristics of scale, temperature, and diffusion time for restricted diffusion. RESULTS: The RD decayed and became constant depending on the structural scale. Diffusion coefficient fluctuations with temperature occurred mostly under conditions of a large structural scale and short diffusion time. We obtained data suggesting that temperature-dependent changes in the diffusion coefficients follow physical laws. CONCLUSION: No water molecules were observed outside the glass tubes in the capillary plates, and the capillary plates only reflected a restricted diffusion process within the structure.We experimentally evaluated the characteristics of simple restricted diffusion to reveal the transitional relationship of the diffusion coefficient with diffusion time, structure scale, and temperature through composite measurement.


Subject(s)
Diffusion Magnetic Resonance Imaging , Magnetic Resonance Imaging , Temperature , Diffusion Magnetic Resonance Imaging/methods , Diffusion , Biological Transport , Phantoms, Imaging , Water
6.
J Neurol Sci ; 456: 122857, 2024 Jan 15.
Article in English | MEDLINE | ID: mdl-38154249

ABSTRACT

INTRODUCTION: Antiplatelet agents are effective for secondary prevention of ischemic stroke and can reduce the severity of first-ever ischemic stroke. However, it is uncertain if prophylactic antiplatelet therapy reduces the severity of recurrent ischemic stroke. The aim of this study was to determine the effect of preceding antiplatelet treatment on the severity of thrombotic stroke (TS) in patients with a prior history of stroke. METHODS: From a prospective hospital registry of 1338 consecutive patients with acute ischemic stroke, we identified patients with a prior history of stroke who were admitted for cardioembolic stroke (CE); TS including large-artery atherosclerosis, small vessel occlusion, and branch atheromatous disease; or other cause or cryptogenic stroke (OCS). Cases in each subtype were categorized based on preceding medication: antiplatelet agents (AP) and none (N). Severity of stroke (National Institutes of Health Stroke Scale: NIHSS) on admission was compared between AP and N cases. RESULTS: The total cohort of 252 patients included 83 with CE, 102 with TS, and 67 with OCS. After excluding those with prior anticoagulants, the median NIHSS on admission was lower in AP cases than in N cases (3 vs. 5, p = 0.002). In multivariate analysis, preceding AP treatment was independently associated with minor stroke (NIHSS ≤4) on admission in CE group (OR 8.48, 95% CI 1.71-62.9, p = 0.008) and TS group (OR 4.24, 95% CI 1.44-13.4, p = 0.009). CONCLUSION: Preceding antiplatelet treatment in patients with a prior history of stroke may reduce the severity of subsequent thrombotic and cardiogenic stroke.


Subject(s)
Brain Ischemia , Ischemic Stroke , Stroke , Humans , Platelet Aggregation Inhibitors/therapeutic use , Prospective Studies , Brain Ischemia/complications , Brain Ischemia/drug therapy , Brain Ischemia/prevention & control , Stroke/drug therapy , Stroke/etiology , Stroke/prevention & control
7.
Sci Rep ; 13(1): 22865, 2023 12 21.
Article in English | MEDLINE | ID: mdl-38129473

ABSTRACT

We aimed to investigate the reliability and validity of sweat lactate threshold (sLT) measurement based on the real-time monitoring of the transition in sweat lactate levels (sLA) under hypoxic exercise. In this cross-sectional study, 20 healthy participants who underwent exercise tests using respiratory gas analysis under hypoxia (fraction of inspired oxygen [FiO2], 15.4 ± 0.8%) in addition to normoxia (FiO2, 20.9%) were included; we simultaneously monitored sLA transition using a wearable lactate sensor. The initial significant elevation in sLA over the baseline was defined as sLT. Under hypoxia, real-time dynamic changes in sLA were successfully visualized, including a rapid, continual rise until volitionary exhaustion and a progressive reduction in the recovery phase. High intra- and inter-evaluator reliability was demonstrated for sLT's repeat determinations (0.782 [0.607-0.898] and 0.933 [0.841-0.973]) as intraclass correlation coefficients [95% confidence interval]. sLT correlated with ventilatory threshold (VT) (r = 0.70, p < 0.01). A strong agreement was found in the Bland-Altman plot (mean difference/mean average time: - 15.5/550.8 s) under hypoxia. Our wearable device enabled continuous and real-time lactate assessment in sweat under hypoxic conditions in healthy participants with high reliability and validity, providing additional information to detect anaerobic thresholds in hypoxic conditions.


Subject(s)
Anaerobic Threshold , Lactic Acid , Humans , Sweat , Reproducibility of Results , Cross-Sectional Studies , Hypoxia , Oxygen Consumption , Exercise Test
8.
Sci Rep ; 13(1): 10366, 2023 06 26.
Article in English | MEDLINE | ID: mdl-37365235

ABSTRACT

A simple, non-invasive algorithm for maximal lactate steady state (MLSS) assessment has not been developed. We examined whether MLSS can be estimated from the sweat lactate threshold (sLT) using a novel sweat lactate sensor for healthy adults, with consideration of their exercise habits. Fifteen adults representing diverse fitness levels were recruited. Participants with/without exercise habits were defined as trained/untrained, respectively. Constant-load testing for 30 min at 110%, 115%, 120%, and 125% of sLT intensity was performed to determine MLSS. The tissue oxygenation index (TOI) of the thigh was also monitored. MLSS was not fully estimated from sLT, with 110%, 115%, 120%, and 125% of sLT in one, four, three, and seven participants, respectively. The MLSS based on sLT was higher in the trained group as compared to the untrained group. A total of 80% of trained participants had an MLSS of 120% or higher, while 75% of untrained participants had an MLSS of 115% or lower based on sLT. Furthermore, compared to untrained participants, trained participants continued constant-load exercise even if their TOI decreased below the resting baseline (P < 0.01). MLSS was successfully estimated using sLT, with 120% or more in trained participants and 115% or less in untrained participants. This suggests that trained individuals can continue exercising despite decreases in oxygen saturation in lower extremity skeletal muscles.


Subject(s)
Anaerobic Threshold , Lactic Acid , Adult , Humans , Anaerobic Threshold/physiology , Exercise Test , Sweat , Bicycling/physiology , Oxygen Consumption
9.
Sensors (Basel) ; 23(7)2023 Mar 23.
Article in English | MEDLINE | ID: mdl-37050438

ABSTRACT

The relationship between the onset of sweating (OS) and sweat lactate threshold (sLT) assessed using a novel sweat lactate sensor remains unclear. We aimed to investigate the implications of the OS on the sLT. Forty healthy men performed an incremental cycling test. We monitored the sweat lactate, blood lactate, and local sweating rates to determine the sLT, blood LT (bLT), and OS. We defined participants with the OS during the warm-up just before the incremental test as the early perspiration (EP) group and the others as the regular perspiration (RP) group. Pearson's correlation coefficient analysis revealed that the OS was poorly correlated with the sLT, particularly in the EP group (EP group, r = 0.12; RP group, r = 0.56). Conversely, even in the EP group, the sLT was strongly correlated with the bLT (r = 0.74); this was also the case in the RP group (r = 0.61). Bland-Altman plots showed no bias between the mean sLT and bLT (mean difference: 19.3 s). Finally, in five cases with a later OS than bLT, the sLT tended to deviate from the bLT (mean difference, 106.8 s). The sLT is a noninvasive and continuous alternative to the bLT, independent of an early OS, although a late OS may negatively affect the sLT.


Subject(s)
Sweat , Sweating , Male , Humans , Lactic Acid , Bicycling
10.
Nat Commun ; 14(1): 532, 2023 Feb 16.
Article in English | MEDLINE | ID: mdl-36797235

ABSTRACT

Chondrule-like objects and Ca-Al-rich inclusions (CAIs) are discovered in the retuned samples from asteroid Ryugu. Here we report results of oxygen isotope, mineralogical, and compositional analysis of the chondrule-like objects and CAIs. Three chondrule-like objects dominated by Mg-rich olivine are 16O-rich and -poor with Δ17O (=δ17O - 0.52 × Î´18O) values of ~ -23‰ and ~ -3‰, resembling what has been proposed as early generations of chondrules. The 16O-rich objects are likely to be melted amoeboid olivine aggregates that escaped from incorporation into 16O-poor chondrule precursor dust. Two CAIs composed of refractory minerals are 16O-rich with Δ17O of ~ -23‰ and possibly as old as the oldest CAIs. The discovered objects (<30 µm) are as small as those from comets, suggesting radial transport favoring smaller objects from the inner solar nebula to the formation location of the Ryugu original parent body, which is farther from the Sun and scarce in chondrules. The transported objects may have been mostly destroyed during aqueous alteration in the Ryugu parent body.

11.
J Infect Chemother ; 29(3): 361-366, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36481565

ABSTRACT

Hemophagocytic lymphohistiocytosis (HLH) is a fatal disease characterized by a highly inflammatory state due to the abnormal activation of T lymphocytes and macrophages. Miliary tuberculosis (MTB) is a rare cause of HLH and its clinical appearances occasionally resembles that of intravascular lymphoma (IVL). A 76-year-old woman presented with persistent fever and fatigue. Abnormal laboratory findings showing thrombocytopenia (13,000/µL), hypofibrinogenemia (101 mg/dL), hyperferritinemia (2,312 ng/mL), and markedly elevated soluble interleukin-2 receptor (sIL-2R) level (32,200 U/mL), in addition, hemophagocytosis in the bone marrow (BM) smear, were suggestive of IVL-associated HLH. The pathology of the BM biopsy specimen showed granuloma with non-caseous necrosis, and culture tests using sputum, gastric fluid, urine, and peripheral and bone marrow blood revealed the presence of Mycobacterium tuberculosis, leading to the final diagnosis of MTB-associated HLH. Anti-TB medications and corticosteroids were administered, but thrombocytopenia, hypofibrinogenemia, and hyperferritinemia persisted. Concomitant use of recombinant thrombomodulin (rTM) enabled regression of clinical status. In this case, BM biopsy served as the diagnosis of MTB-associated HLH, although IVL-associated HLH is initially suspected by an extremely high level of sIL-2R. Furthermore, this case report informs that using rTM could improve the outcomes of MTB-associated HLH.


Subject(s)
Afibrinogenemia , Hyperferritinemia , Lymphohistiocytosis, Hemophagocytic , Thrombocytopenia , Tuberculosis, Miliary , Female , Humans , Aged , Lymphohistiocytosis, Hemophagocytic/complications , Lymphohistiocytosis, Hemophagocytic/diagnosis , Lymphohistiocytosis, Hemophagocytic/drug therapy , Tuberculosis, Miliary/complications , Tuberculosis, Miliary/diagnosis , Tuberculosis, Miliary/drug therapy , Afibrinogenemia/complications , Thrombomodulin/therapeutic use , Hyperferritinemia/complications , Thrombocytopenia/complications , Receptors, Interleukin-2
12.
Sensors (Basel) ; 22(24)2022 Dec 07.
Article in English | MEDLINE | ID: mdl-36559954

ABSTRACT

A novel exercise modality combined with electrical muscle stimulation (EMS) has been reported to increase cardiovascular and metabolic responses, such as blood lactate concentration. We aimed to examine the effect of constant load pedaling exercise, combined with EMS, by non-invasively and continuously measuring sweat lactate levels. A total of 22 healthy young men (20.7 ± 0.8 years) performed a constant load pedaling exercise for 20 min at 125% of the pre-measured ventilatory work threshold with (EMS condition) and without (control condition) EMS stimulation. Blood lactate concentration was measured by blood samples obtained from the earlobe every minute. Sweat lactate was monitored in real time using a sensor placed on the forearm. The sweat lactate threshold (sLT) was defined as the point of increase in sweat lactate. sLT occurred significantly earlier in the EMS condition than in the control condition. In the single regression analysis, the difference in sLT between the two conditions, as the independent variable, was a significant predictor of the difference in blood lactate concentrations at the end of the exercise (p < 0.05, r = −0.52). Sweat lactate measurement may be a noninvasive and simple alternative to blood lactate measurement to determine the effectiveness of exercise combined with EMS.


Subject(s)
Exercise , Sweat , Male , Humans , Exercise/physiology , Sweating , Lactic Acid , Muscle, Skeletal/physiology
13.
Earth Planets Space ; 74(1): 146, 2022.
Article in English | MEDLINE | ID: mdl-36185784

ABSTRACT

Millimetre-sized primordial rock fragments originating from asteroid Ryugu were investigated using high energy X-ray fluorescence spectroscopy, providing 2D and 3D elemental distribution and quantitative composition information on the microscopic level. Samples were collected in two phases from two sites on asteroid Ryugu and safely returned to Earth by JAXA's asteroid explorer Hayabusa2, during which time the collected material was stored and maintained free from terrestrial influences, including exposure to Earth's atmosphere. Several grains of interest were identified and further characterised to obtain quantitative information on the rare earth element (REE) content within said grains, following a reference-based and computed-tomography-assisted fundamental parameters quantification approach. Several orders of magnitude REE enrichments compared to the mean CI chondrite composition were found within grains that could be identified as apatite phase. Small enrichment of LREE was found for dolomite grains and slight enrichment or depletion for the general matrices within the Ryugu rock fragments A0055 and C0076, respectively. Supplementary Information: The online version contains supplementary material available at 10.1186/s40623-022-01705-3.

14.
Appl Bionics Biomech ; 2022: 7929589, 2022.
Article in English | MEDLINE | ID: mdl-35979242

ABSTRACT

In the human body, skeletal muscle microstructures have been evaluated only by biopsy. Noninvasive examination of the microstructure of muscles would be useful for research and clinical practice in sports and musculoskeletal areas. The study is aimed at determining if q-space imaging (QSI) can reveal the microstructure of muscles in humans. Forty-three Japanese subjects (controls, distance runners, powerlifting athletes, and teenage runners) were included in this cross-sectional study. Magnetic resonance imaging of the lower leg was performed. On each leg muscle, full width at half maximum (FWHM) which indicated the muscle cell diameters and pennation angle (PA) were measured and compared. FWHM showed significant positive correlations with PA, which is related to muscle strength. In addition, FWHM was higher for powerlifting, control, distance running, and teenager, in that order, suggesting that it may be directing the diameter of each muscle cell. Type 1 and type 2 fibers are enlarged by growth, so the fact that the FWHM of the control group was larger than that of the teenagers in this study may indicate that the muscle fibers were enlarged by growth. Also, FWHM has the possibility to increase with increased muscle fibers caused by training. We showed that QSI had the possibility to depict noninvasively the microstructure like muscle fiber type and subtle changes caused by growth and sports characteristics, which previously could only be assessed by biopsy.

15.
Sensors (Basel) ; 22(15)2022 Jul 22.
Article in English | MEDLINE | ID: mdl-35897977

ABSTRACT

Epidermal wearable sweat biomarker sensing technologies are likely affected by sweat rate because of the dilution effect and limited measurement methods. However, there is a dearth of reports on the local sweat rate (LSR) monitored in real-time during exercise. This explorative study investigated the feasibility of real-time LSR monitoring and clarified LSR kinetics on the forehead and upper arm during constant-load exercise using a perspiration meter with an airflow compensation system. This observational cross-sectional study included 18 recreationally trained males (mean age, 20.6 ± 0.8 years). LSR on the forehead and upper arm (mg/cm2/min) were measured during a constant-load exercise test at 25% of their pre-evaluated peak power until exhaustion. The LSR kinetics had two inflection points, with a gradual decrease in the incremental slope for each section. After the second flexion point, the LSR slope slightly decreased and was maintained until exhaustion. However, the degree of change varied among the participants. Although the ratio of forehead LSR to upper arm LSR tended to decrease gradually over time, there was little change in this ratio after a second flexion point of LSR in both. These findings suggest possible differences in LSR control between the forehead and upper arm during constant-load exercise to prolonged exhaustion.


Subject(s)
Sweat , Sweating , Adult , Exercise , Exercise Test , Hot Temperature , Humans , Kinetics , Male , Young Adult
16.
Sensors (Basel) ; 22(13)2022 Jul 03.
Article in English | MEDLINE | ID: mdl-35808520

ABSTRACT

Laser remote sensing using a sweep pulse excitation method, in which a laser beam is irradiated at the same repetition frequency as the natural frequency, for enhancing photoacoustic elastic waves through resonance effect has been studied. The sweep pulse excitation method, which is based on the principle of detecting natural frequency fluctuations, such as hammering tests, can detect natural frequencies in the audible sound region with low average laser power and contribute to the convenience and low cost of an installation strength diagnosis of fastening bolts. In this study, we investigated the dynamics of the swept excitation method for optimization by evaluating the dependence of the laser irradiation conditions (pulse width, spot size, and average power) on different metal disc samples. We discovered that the magnitude of the photoacoustic elastic wave is proportional to the absorption of laser power, and the spatiotemporal dynamics can be explained through thermal diffusion phenomena. These findings contribute to the development of laser-sensing technology based on photoacoustic elastic waves.


Subject(s)
Lasers , Sound , Light , Spectrum Analysis
17.
BMC Musculoskelet Disord ; 23(1): 669, 2022 Jul 14.
Article in English | MEDLINE | ID: mdl-35831832

ABSTRACT

BACKGROUND: A small, wearable thermo device that uses Peltier elements for programmed heat and cold stimulation has been developed recently and is expected to be applied in conventional contrast bath therapy. This study was aimed to examine improvements in trapezius muscle hardness and subjective symptoms resulting from alternating heat and cold stimulation, with different rates of cooling. METHODS: This cross-over study included four conditions. Twenty healthy young male individuals (age, 22.3 ± 4.5 years) participated in this study. These four interventions targeted the unilateral trapezius muscle of the dominant arm after a 15-min typing task. Specifically, heat and cold stimulations were applied at different ratios (the heating/cooling rate of 3:1, 3:2, and 3:3) or not applied. Each intervention was separated by at least one week. Skin temperature at the stimulation area was recorded using a data logger. Outcome measures included muscle hardness (measured using a portable tester) and subjective symptoms (muscle stiffness and fatigue). Each item was assessed at three time points: baseline, after typing, and after the intervention. RESULTS: Two-way analysis of variance with repeated measures found an interaction effect for muscle hardness between four conditions (3:1, 3:2, 3:3, and no) and three time points (p < 0.05). Only in the 3:1 condition were the post-intervention values lower than those after typing (p < 0.01). There was also an interaction effect for subjective muscle stiffness (p < 0.05); the values after the intervention in the 3:1 condition were lower than those after intervention in the no stimulation condition (p < 0.01). There was no significant relationship between changes in muscle hardness and changes in subjective symptoms in the 3:1 condition. CONCLUSIONS: Our results demonstrate that alternating heat and cold stimulations with a different cooling rate could affect the degree of improvement in muscle hardness and subjective symptoms. In particular, the 3:1 condition has the possibility to improved muscle hardness within the condition and subjective muscle stiffness between conditions. TRIAL REGISTRATION: UMIN000040620. Registered 1 June 2020, https://upload.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000046359.


Subject(s)
Joint Diseases , Superficial Back Muscles , Wearable Electronic Devices , Adolescent , Adult , Cross-Over Studies , Hot Temperature , Humans , Male , Shoulder , Young Adult
18.
Physiol Rep ; 10(2): e15169, 2022 01.
Article in English | MEDLINE | ID: mdl-35043587

ABSTRACT

It is useful to investigate various physiological responses induced by fatigue in athletes. Moreover, wearable noninvasive sensors, including sweat sensors, are compatible with fatigue evaluation because of their ease of use, and ability to measure repeatedly and continual data. This cross-sectional study aimed to clarify how sweat lactate elimination curves obtained during constant workload exercise changed following fatigue. Seventeen recreationally trained males (average age, 20.6 ± 0.8 years) completed two consecutive constant workload exercise tests (at 25% peak power) with rest intervals; the participants were encouraged to perform Test 1 until exhaustion and Test 2 only for 10 min. Subjective fatigue (numerical rating scale with face rating scale), sweat lactate, and sweat rate were measured for 10 min in each test. Subjective fatigue was compared using the Wilcoxon signed-rank test and time to each constant value between Tests 1 and 2 was compared using paired t-test. Subjective fatigue significantly increased during Test 2 compared with that during Test 1. After Test 1, the sweat lactate elimination curve demonstrated a leftward shift, as proved by the significantly sooner observation of the peak and constant values of sweat lactate (2, 3, and 4 µA) (p < 0.01). Our preliminary results suggest that the sweat lactate elimination curve is different in the fatigue state. Further research may provide insight in the application of this curve to the evaluation for fatigue.


Subject(s)
Lactic Acid , Sweat , Adult , Cross-Sectional Studies , Exercise Test , Fatigue , Humans , Male , Workload , Young Adult
19.
J Physiol Anthropol ; 41(1): 1, 2022 Jan 03.
Article in English | MEDLINE | ID: mdl-34980256

ABSTRACT

BACKGROUND: Technological innovations have allowed the use of miniature apparatus that can easily control and program heat and cold stimulations using Peltier elements. The wearable thermo-device has a potential to be applied to conventional contrast bath therapy. This study aimed to examine the effects of alternating heat and cold stimulation (HC) using a wearable thermo-device on subjective and objective improvement of shoulder stiffness. METHODS: Twenty healthy young male individuals (20.3 ± 0.6 years) participated in this study. The interventions were randomly conducted under four conditions, including HC, heat stimulation, cold stimulation, and no stimulation on their bilateral trapezius muscle, after a 30-min typing task. Each intervention was administered at least 1 week apart. The analyzed limb was the dominant arm. Muscle hardness was assessed using a portable muscle hardness meter, as well as the skin temperature over the stimulated area. After each condition, the participants were asked for feedback regarding subjective improvement in refreshed feelings, muscle stiffness, and muscle fatigue using an 11-point numerical rating scale. RESULTS: With regard to muscle hardness, only the HC condition significantly decreased from 1.43 N to 1.37 N (d = 0.44, p < 0.05). Additionally, reduced muscle hardness in HC condition was associated with the degree of skin cooling during the intervention (cold max: r = 0.634, p < 0.01; cold change: r = -0.548, p < 0.05). Subjective improvement in refreshed feelings, muscle stiffness, and muscle fatigue was determined in the HC and heat stimulation conditions compared with the no stimulation condition (p < 0.01 and p < 0.05, respectively). Moreover, the HC condition showed significantly greater improvements in muscle stiffness and fatigue compared to the cold stimulation condition (p < 0.05). CONCLUSIONS: The current study demonstrated that HC promoted not only better subjective symptoms, such as muscle stiffness and fatigue, but also lesser muscle hardness. Furthermore, an association was observed between the degree of skin temperature cooling and reduced muscle hardness during HC. Further investigations on the ratio and intensity of cooling should be conducted in the future to establish the optimal HC protocol for muscle stiffness or fatigue. TRIAL REGISTRATION: UMIN000040620 . Registered 1 June 2020.


Subject(s)
Cold Temperature , Diagnostic Self Evaluation , Hot Temperature , Range of Motion, Articular , Shoulder Joint/physiopathology , Superficial Back Muscles/physiopathology , Wearable Electronic Devices , Humans , Male , Young Adult
20.
Eur Spine J ; 31(2): 215-224, 2022 02.
Article in English | MEDLINE | ID: mdl-33245417

ABSTRACT

PURPOSE: A close relationship between sagittal spinal alignment and hip osteoarthritis (OA) has been documented. This study aimed to examine the relationship between hip joint proximity area and sagittal balance parameters in healthy subjects. METHODS: This prospective study enrolled 47 healthy volunteers who underwent 320-detector row upright computed tomography. Acquired data were reconstructed in a virtual three-dimensional space. The proximity area was determined by < 1 mm of the Hausdorff distance between the acetabulum and the femoral head. Volunteers were divided into the anterior and posterior proximity groups depending on the position of the closest area. Sagittal balance parameters [sagittal vertical axis (SVA), T1 spinopelvic inclination (T1-SPi), T1-pelvic angle, pelvic tilt, sacral slope, pelvic incidence, lumbar lordosis, thoracic kyphosis), offset distance between the centre of the acoustic meati (CAM) and C7 plumb line (CAM-C7-offset), and offset distance between the CAM and hip axis (HA) (CAM-HA-offset)] were compared between the two groups using independent sample t test. RESULTS: The anterior proximity group (n = 24) had higher SVA (p = 0.016) and T1-Spi (p = 0.015) than the posterior proximity group (n = 23). CAM-HA-offset was higher in the posterior than in the anterior proximity group (p < 0.000). There was no difference in other parameters (p > 0.05). CONCLUSION: The anterior proximity group had a positive anterior spinal balance; the posterior proximity group may have a more posterior gravity line than the hip joint centre. The anterior spinal balance may contribute to the anterior loading of the hip joint, with known relation with the initiation and onset of hip OA.


Subject(s)
Lordosis , Hip Joint/diagnostic imaging , Humans , Prospective Studies , Sacrum , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...