Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-38761054

ABSTRACT

The pacing threshold is important for leadless pacemakers, as the pacing output has a significant impact on battery longevity. Acute pacing rate-dependent threshold increases have also been reported with leadless pacemakers. In the present case, we experienced a case in which the threshold, which had been raised in the acute phase, once showed a tendency to improve, but then worsened again. And, as in previous reports, thresholds improved completely in the chronic phase. Repeated retrieval and reimplantation of leadless pacemakers increases the likelihood of fatal complications, so being aware of such phenomenon may prevent unnecessary procedure and complications.

2.
J Interv Card Electrophysiol ; 65(1): 45-51, 2022 Oct.
Article in English | MEDLINE | ID: mdl-34985641

ABSTRACT

PURPOSE: The best strategy for durable left atrial posterior wall isolation (PWI) after completion of pulmonary vein isolation (PVI) is not yet determined. This study aimed to examine the differences in the durability of PWI based on the isolation process and the predictors of the reconduction of PWI. METHODS: Among the 221 patients (mean age, 65 ± 11 years) with consecutive non-paroxysmal atrial fibrillation (AF) who completed PVI and PWI, 50 patients undergoing repeat AF ablation were enrolled and divided into the following groups based on how PWI was achieved at the initial procedure: by only the first line on the roof and floor line (group A), by additional gap ablation to the first line or second liner ablation next to the first line (group B), and by adjunct ablation inside the PW revealing the earliest activation (group C). RESULTS: Reconduction of PWI occurred in 24 of the 50 patients (48%). The durability of PWI in groups A, B, and C was 81% (17 of 21 patients), 75% (6 of 8 patients), and 14% (3 of 21 patients), respectively (p < 0.01). In a multivariate analysis, the ablation inside the PW for PWI was the independent predictor of the reconduction of PWI (p < 0.001). CONCLUSION: PWI achieved by the ablation inside the PW resulted in a high rate of reconduction. It may be necessary to aim to achieve the PWI without ablating the inside of the PW to prevent reconduction.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Aged , Atrial Fibrillation/surgery , Catheter Ablation/methods , Heart Atria/surgery , Humans , Middle Aged , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
3.
Pacing Clin Electrophysiol ; 44(12): 1987-1994, 2021 Dec.
Article in English | MEDLINE | ID: mdl-34662435

ABSTRACT

BACKGROUND: In performing left bundle branch pacing (LBBP), various QRS morphologies are observed as the lead penetrates the ventricular septum (VS). This study aimed to evaluate these characteristics and infer the mechanism underlying each QRS morphology. METHODS: In 19 patients who met the strict criteria for LBB capture, we classified the QRS morphologies observed during the LBBP procedure into seven patterns, the first five of which were determined by the depth of penetration: right ventricular septal pacing (RVSP), intraventricular septal pacing (IVSP1 and IVSP2), endocardial side of left ventricular septal pacing (LVSeP), nonselective LBBP (NS-LBBP), selective LBBP (S-LBBP), and NS-LBBP with anodal capture. The parameters of the QRS morphologies in these seven patterns were evaluated. RESULTS: Among the first five patterns, stimulus-QRSend duration (s-QRSend) was the narrowest in IVSP1 rather than in NS-LBBP, and stimulus-to-peak of R wave in V6 (s-LVAT) was significantly shortened in two steps, from RVSP to IVSP1 (96 ± 11; 82 ± 8 ms, p < .01) and from LVSeP to NS-LBBP (76 ± 7; 60 ± 4 ms, p < .01). The late-R duration in V1 was significantly prolonged in the order of LVSeP, NS-LBBP, and S-LBBP (45 ± 7; 53 ± 10; 71 ± 15 ms, respectively, p < .01). CONCLUSIONS: s-QRSend was the narrowest in IVSP1 rather than in NS-LBBP among the QRS morphologies observed during lead penetration through the VS. The prolonged late-R duration in V1 and abrupt shortening of the s-LVAT in V6 may help determine LBB capture during lead penetration.


Subject(s)
Bundle-Branch Block/physiopathology , Cardiac Pacing, Artificial/methods , Electrodes, Implanted , Ventricular Septum/physiopathology , Aged , Electrocardiography , Female , Humans , Male
4.
Eur Heart J Case Rep ; 4(4): 1-5, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32974479

ABSTRACT

BACKGROUND: Although left bundle branch area pacing (LBBAP) can capture the His-Purkinje conduction system and create a narrower paced QRS duration, its mechanism has not been investigated. In this case report, ventricular activation patterns were evaluated using three-dimensional electroanatomical mapping during LBBAP and right ventricular septal pacing (RVSP). CASE SUMMARY: An 81-year-old woman with sick sinus syndrome received LBBAP, followed 4 months later with atrial fibrillation ablation. We compared ventricular activation patterns during RVSP and LBBAP using a three-dimensional electro-anatomical mapping system. Paced QRS durations during RVSP and LBBAP were 163 ms and 115 ms, respectively. The activation pattern and the total left ventricular (LV) activation time were similar during RVSP and LBBAP (86 and 73 ms, respectively), despite the conduction system capture during LBBAP. The stimulus interval to the latest LV activation point during RVSP was 117 ms, and transseptal conduction time was 31 ms (117 - 86 ms). DISCUSSION: Although LBBAP could capture the His-Purkinje conduction system, neither ventricular activation patterns nor total activation time changed dramatically. The mechanism of narrower paced QRS duration during LBBAP compared to that during RVSP can be attributable to passing over the slow transseptal conduction.

SELECTION OF CITATIONS
SEARCH DETAIL
...