1.
Sensors (Basel) ; 23(5)2023 Feb 25.
Article in English | MEDLINE | ID: mdl-36904759

ABSTRACT

Smartwatches that support the recording of a single-lead electrocardiogram (ECG) are increasingly being used beyond the wrist, by placement on the ankle and on the chest. However, the reliability of frontal and precordial ECGs other than lead I is unknown. This clinical validation study assessed the reliability of an Apple Watch (AW) to obtain conventional frontal and precordial leads as compared to standard 12-lead ECGs in both subjects without known cardiac anomalies and patients with underlying heart disease. In 200 subjects (67% with ECG anomalies), a standard 12-lead ECG was performed, followed by AW recordings of the standard Einthoven leads (leads I, II, and III) and precordial leads V1, V3, and V6. Seven parameters (P, QRS, ST, and T-wave amplitudes, PR, QRS, and QT intervals) were compared through a Bland-Altman analysis, including the bias, absolute offset, and 95% limits of agreement. AW-ECGs recorded on the wrist but also beyond the wrist had similar durations and amplitudes compared to standard 12-lead ECGs. Significantly greater amplitudes were measured by the AW for R-waves in precordial leads V1, V3, and V6 (+0.094 mV, +0.149 mV, +0.129 mV, respectively, all p < 0.001), indicating a positive bias for the AW. AW can be used to record frontal, and precordial ECG leads, paving the way for broader clinical applications.


Subject(s)
Electrocardiography , Heart Diseases , Humans , Reproducibility of Results , Arrhythmias, Cardiac , Thorax
2.
J Cardiovasc Electrophysiol ; 33(5): 1067-1069, 2022 05.
Article in English | MEDLINE | ID: mdl-35229391

ABSTRACT

We report a case report of a 68-year-old man with chemotherapy-induced cardiomyopathy and uncontrolled permanent atrial fibrillation. Cardiac resynchronization therapy implantation and atrioventricular junction ablation were planned. DF-1 single chamber defibrillator was connected to lead's defibrillation and a lead destinated to left bundle branch area pacing. This system leads to reduce costs by one-third, improve battery longevity, and provide a more physiological pacing.


Subject(s)
Atrial Fibrillation , Cardiac Resynchronization Therapy , Cardiomyopathies , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/therapy , Bundle of His , Cardiac Pacing, Artificial , Defibrillators , Heart Block , Humans , Male , Treatment Outcome
3.
Europace ; 24(3): 406-412, 2022 Mar 02.
Article in English | MEDLINE | ID: mdl-34468759

ABSTRACT

AIMS: Smartwatch electrocardiograms (ECGs) could facilitate the detection of sudden cardiac arrest (SCA)-associated abnormalities. We evaluated the feasibility of using smartwatch-derived ECGs for detecting SCA-associated abnormalities in young adults and its agreement with 12-lead ECGs. METHODS AND RESULTS: Twelve-lead and Apple Watch ECGs were registered in 155 healthy volunteers and 67 patients aged 18-45 years with diagnosis and ECG signs of long-QT syndrome (n = 10), Brugada syndrome (n = 12), ventricular pre-excitation (n = 19), hypertrophic cardiomyopathy (HCM, n = 13), and arrhythmogenic right ventricular dysplasia/cardiomyopathy (ARVC/D, n = 13). Cardiologists separately analysed 12-lead ECGs and the smartwatch ECGs taken from the left wrist (AW-I) and then from chest positions V1, V3, and V6 (AW-4). Compared with AW-I, AW-4 improved the classification of ECGs as 'abnormal', increasing the sensitivity from 64% to 89% (P < 0.01). Pre-excitation was detected in most cases using AW-I (sensitivity 89%) and in all cases using AW-4 (sensitivity 100%, P = 0.48 compared with AW-I, specificity 100% for both). Brugada was missed using AW-I but was detected in 11/12 patients using AW-4 (sensitivity 92%, specificity 100%, P = 0.003). Long QT was detected in 8/10 cases using AW-I (sensitivity 80%, specificity 100%) and in 9 patients using AW-4 (sensitivity 90%, specificity 100%, P > 0.99). Hypertrophic cardiomyopathy was correctly suspected using AW-I and AW-4 (sensitivity 92% and 85%, specificity 85%, and 100%, P > 0.99). AW-I was mostly (62%) considered normal in ARVC/D whereas AW-4 was useful in suspecting ARVC/D (100% sensitivity, 99% specificity, P = 0.004). CONCLUSIONS: Detection of SCA-associated ECG abnormalities (pre-excitation, Brugada patterns, long QT, and signs suggestive of HCM and ARVC/D) is possible with an ECG smartwatch.


Subject(s)
Arrhythmogenic Right Ventricular Dysplasia , Brugada Syndrome , Long QT Syndrome , Adolescent , Adult , Death, Sudden, Cardiac/etiology , Electrocardiography/methods , Humans , Middle Aged , Young Adult