Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Pathol Int ; 2024 May 15.
Article in English | MEDLINE | ID: mdl-38751008

ABSTRACT

We conducted an autopsy on a 3-month-old boy in whom Kawasaki disease (KD) was strongly suspected based on the autopsy findings. The infant had a fever and was brought to a nearby clinic, where he was prescribed antipyretics and kept under observation. However, 15 days after onset of the fever, he suddenly died in bed. He exhibited no obvious redness of the lips, tongue, or conjunctiva. Membranous desquamation was present on his distal fingers. Vasculitis was observed in the coronary arteries, renal artery, splenic artery, and pulmonary vein. In addition, coronary artery aneurysms were present in the right coronary artery and left anterior descending artery. Thrombotic occlusion was observed in one aneurysm in the right coronary artery, resulting in acute myocardial infarction. The coronary artery wall showed infiltration of numerous macrophages and neutrophils. This case was classified as incomplete KD because the coronary artery aneurysm could not be demonstrated before death and was only recognized at autopsy. Pathologists and forensic scientists need to be aware that there are cases in which KD goes undiagnosed and untreated, leading to coronary artery aneurysm formation and sudden death.

2.
Micromachines (Basel) ; 14(3)2023 Feb 22.
Article in English | MEDLINE | ID: mdl-36984914

ABSTRACT

An acicular microtextured sheet was developed as a heat radiation device from the high-temperature source to the cooling medium in the infrared (IR) spectrum. The copper surface was modified by acicular micro-texturing to place a semi-regular micro-/nano-cone structure onto it. FT-IR (Fourier transformation IR) spectroscopy was utilized to measure the transmittance diagram in near-IR to far-IR wavelengths. The wavelength (λ) of 6.7 µm, where the highest absorbance valley was detected in the diagram, was equivalent to the doubled size of the micro-cone average height, with Have = 3.3 µm; λ ~ 2 × Have. The electromagnetic waves in the far-IR wavelength were emitted by acicular micro-textured metallic sheets. The heat radiation transfer experiment was performed to describe this low-temperature heat radiation behavior. No temperature rise was detected on the black-colored polycarbonate (BC-PC) plate away from the bare copper sheet without textures, located on the high-temperature source. The temperature increased by 4 K on the BC-PC plate using the acicular textured copper sheet device. The emitter temperature also decreased significantly by 50 K or 50% of the heat source temperature.

SELECTION OF CITATIONS
SEARCH DETAIL
...