Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters











Publication year range
1.
Sensors (Basel) ; 24(10)2024 May 10.
Article in English | MEDLINE | ID: mdl-38793895

ABSTRACT

Brain-computer interface (BCI) systems include signal acquisition, preprocessing, feature extraction, classification, and an application phase. In fNIRS-BCI systems, deep learning (DL) algorithms play a crucial role in enhancing accuracy. Unlike traditional machine learning (ML) classifiers, DL algorithms eliminate the need for manual feature extraction. DL neural networks automatically extract hidden patterns/features within a dataset to classify the data. In this study, a hand-gripping (closing and opening) two-class motor activity dataset from twenty healthy participants is acquired, and an integrated contextual gate network (ICGN) algorithm (proposed) is applied to that dataset to enhance the classification accuracy. The proposed algorithm extracts the features from the filtered data and generates the patterns based on the information from the previous cells within the network. Accordingly, classification is performed based on the similar generated patterns within the dataset. The accuracy of the proposed algorithm is compared with the long short-term memory (LSTM) and bidirectional long short-term memory (Bi-LSTM). The proposed ICGN algorithm yielded a classification accuracy of 91.23 ± 1.60%, which is significantly (p < 0.025) higher than the 84.89 ± 3.91 and 88.82 ± 1.96 achieved by LSTM and Bi-LSTM, respectively. An open access, three-class (right- and left-hand finger tapping and dominant foot tapping) dataset of 30 subjects is used to validate the proposed algorithm. The results show that ICGN can be efficiently used for the classification of two- and three-class problems in fNIRS-based BCI applications.


Subject(s)
Algorithms , Brain-Computer Interfaces , Deep Learning , Neural Networks, Computer , Spectroscopy, Near-Infrared , Humans , Spectroscopy, Near-Infrared/methods , Male , Adult , Female , Young Adult , Brain/physiology , Brain/diagnostic imaging
2.
Sensors (Basel) ; 22(7)2022 Mar 28.
Article in English | MEDLINE | ID: mdl-35408190

ABSTRACT

Brain-computer interface (BCI) systems based on functional near-infrared spectroscopy (fNIRS) have been used as a way of facilitating communication between the brain and peripheral devices. The BCI provides an option to improve the walking pattern of people with poor walking dysfunction, by applying a rehabilitation process. A state-of-the-art step-wise BCI system includes data acquisition, pre-processing, channel selection, feature extraction, and classification. In fNIRS-based BCI (fNIRS-BCI), channel selection plays a vital role in enhancing the classification accuracy of the BCI problem. In this study, the concentration of blood oxygenation (HbO) in a resting state and in a walking state was used to decode the walking activity and the resting state of the subject, using channel selection by Least Absolute Shrinkage and Selection Operator (LASSO) homotopy-based sparse representation classification. The fNIRS signals of nine subjects were collected from the left hemisphere of the primary motor cortex. The subjects performed the task of walking on a treadmill for 10 s, followed by a 20 s rest. Appropriate filters were applied to the collected signals to remove motion artifacts and physiological noises. LASSO homotopy-based sparse representation was used to select the most significant channels, and then classification was performed to identify walking and resting states. For comparison, the statistical spatial features of mean, peak, variance, and skewness, and their combination, were used for classification. The classification results after channel selection were then compared with the classification based on the extracted features. The classifiers used for both methods were linear discrimination analysis (LDA), support vector machine (SVM), and logistic regression (LR). The study found that LASSO homotopy-based sparse representation classification successfully discriminated between the walking and resting states, with a better average classification accuracy (p < 0.016) of 91.32%. This research provides a step forward in improving the classification accuracy of fNIRS-BCI systems. The proposed methodology may also be used for rehabilitation purposes, such as controlling wheelchairs and prostheses, as well as an active rehabilitation training technique for patients with motor dysfunction.


Subject(s)
Brain-Computer Interfaces , Electroencephalography , Humans , Imagination , Spectroscopy, Near-Infrared/methods , Support Vector Machine , Walking
3.
Sensors (Basel) ; 22(5)2022 Mar 01.
Article in English | MEDLINE | ID: mdl-35271077

ABSTRACT

This research presents a brain-computer interface (BCI) framework for brain signal classification using deep learning (DL) and machine learning (ML) approaches on functional near-infrared spectroscopy (fNIRS) signals. fNIRS signals of motor execution for walking and rest tasks are acquired from the primary motor cortex in the brain's left hemisphere for nine subjects. DL algorithms, including convolutional neural networks (CNNs), long short-term memory (LSTM), and bidirectional LSTM (Bi-LSTM) are used to achieve average classification accuracies of 88.50%, 84.24%, and 85.13%, respectively. For comparison purposes, three conventional ML algorithms, support vector machine (SVM), k-nearest neighbor (k-NN), and linear discriminant analysis (LDA) are also used for classification, resulting in average classification accuracies of 73.91%, 74.24%, and 65.85%, respectively. This study successfully demonstrates that the enhanced performance of fNIRS-BCI can be achieved in terms of classification accuracy using DL approaches compared to conventional ML approaches. Furthermore, the control commands generated by these classifiers can be used to initiate and stop the gait cycle of the lower limb exoskeleton for gait rehabilitation.


Subject(s)
Brain-Computer Interfaces , Discriminant Analysis , Gait , Humans , Neural Networks, Computer , Spectroscopy, Near-Infrared/methods
4.
Sensors (Basel) ; 20(23)2020 Dec 07.
Article in English | MEDLINE | ID: mdl-33297516

ABSTRACT

A state-of-the-art brain-computer interface (BCI) system includes brain signal acquisition, noise removal, channel selection, feature extraction, classification, and an application interface. In functional near-infrared spectroscopy-based BCI (fNIRS-BCI) channel selection may enhance classification performance by identifying suitable brain regions that contain brain activity. In this study, the z-score method for channel selection is proposed to improve fNIRS-BCI performance. The proposed method uses cross-correlation to match the similarity between desired and recorded brain activity signals, followed by forming a vector of each channel's correlation coefficients' maximum values. After that, the z-score is calculated for each value of that vector. A channel is selected based on a positive z-score value. The proposed method is applied to an open-access dataset containing mental arithmetic (MA) and motor imagery (MI) tasks for twenty-nine subjects. The proposed method is compared with the conventional t-value method and with no channel selected, i.e., using all channels. The z-score method yielded significantly improved (p < 0.0167) classification accuracies of 87.2 ± 7.0%, 88.4 ± 6.2%, and 88.1 ± 6.9% for left motor imagery (LMI) vs. rest, right motor imagery (RMI) vs. rest, and mental arithmetic (MA) vs. rest, respectively. The proposed method is also validated on an open-access database of 17 subjects, containing right-hand finger tapping (RFT), left-hand finger tapping (LFT), and dominant side foot tapping (FT) tasks.The study shows an enhanced performance of the z-score method over the t-value method as an advancement in efforts to improve state-of-the-art fNIRS-BCI systems' performance.

5.
J Neural Eng ; 17(5): 056025, 2020 10 15.
Article in English | MEDLINE | ID: mdl-33055382

ABSTRACT

OBJECTIVE: In this paper, a novel methodology for feature extraction to enhance classification accuracy of functional near-infrared spectroscopy (fNIRS)-based two-class and three-class brain-computer interface (BCI) is presented. APPROACH: Novel features are extracted using vector-based phase analysis method. Changes in oxygenated [Formula: see text] and de-oxygenated [Formula: see text]) haemoglobin are used to calculate four novel features: change in cerebral blood volume ([Formula: see text]), change in cerebral oxygen exchange ([Formula: see text]), vector magnitude (|L|) and angle (k). [Formula: see text] is the sum and [Formula: see text] is difference of [Formula: see text] and [Formula: see text], whereas |L| is magnitude and k is angle of vector. fNIRS signals of seven healthy subjects, corresponding to left-hand index finger tapping (LFT), right-hand index finger tapping (RFT) and rest are acquired from motor cortex using multi-channel continuous-wave imaging system. After removing physiological and instrumental noises from the acquired signals, the four novel features are calculated. For validation, conventional temporal, spatial and spatiotemporal features; mean, peak, slope, variance, kurtosis and skewness are also calculated using [Formula: see text] and[Formula: see text]. All possible two-feature and three-feature combinations of the novel and conventional features are then used to classify two-class (LFT vs RFT) and three-class (LFT vs RFT vs rest) fNIRS-BCI using linear discriminant analysis. MAIN RESULTS: Results demonstrate that combination of four novel features yields significantly higher average classification accuracies of 98.7 ± 1.0% and 85.4 ± 1.4% as compared to 68.7 ± 6.9% and 53.6 ± 10.6% using conventional features for two-class and three-class problem, respectively. Validation of proposed method on an open access database containing RFT, LFT and dominant side foot tapping tasks for 30 subjects also shows improvement in average classification accuracies for two-class and three-class fNIRS-BCIs. SIGNIFICANCE: This study provides a step forward in improving the classification accuracies of state-of-the-art fNIRS-BCIs by showing significant improvement in classification accuracies of two-class and three-class fNIRS-BCIs using novel features extracted by vector-based phase analysis.


Subject(s)
Brain-Computer Interfaces , Motor Cortex , Discriminant Analysis , Humans , Imagination , Spectroscopy, Near-Infrared
6.
J Neuroeng Rehabil ; 15(1): 7, 2018 02 05.
Article in English | MEDLINE | ID: mdl-29402310

ABSTRACT

BACKGROUND: In this paper, a novel functional near-infrared spectroscopy (fNIRS)-based brain-computer interface (BCI) framework for control of prosthetic legs and rehabilitation of patients suffering from locomotive disorders is presented. METHODS: fNIRS signals are used to initiate and stop the gait cycle, while a nonlinear proportional derivative computed torque controller (PD-CTC) with gravity compensation is used to control the torques of hip and knee joints for minimization of position error. In the present study, the brain signals of walking intention and rest tasks were acquired from the left hemisphere's primary motor cortex for nine subjects. Thereafter, for removal of motion artifacts and physiological noises, the performances of six different filters (i.e. Kalman, Wiener, Gaussian, hemodynamic response filter (hrf), Band-pass, finite impulse response) were evaluated. Then, six different features were extracted from oxygenated hemoglobin signals, and their different combinations were used for classification. Also, the classification performances of five different classifiers (i.e. k-Nearest Neighbour, quadratic discriminant analysis, linear discriminant analysis (LDA), Naïve Bayes, support vector machine (SVM)) were tested. RESULTS: The classification accuracies obtained from SVM using the hrf were significantly higher (p < 0.01) than those of the other classifier/ filter combinations. Those accuracies were 77.5, 72.5, 68.3, 74.2, 73.3, 80.8, 65, 76.7, and 86.7% for the nine subjects, respectively. CONCLUSION: The control commands generated using the classifiers initiated and stopped the gait cycle of the prosthetic leg, the knee and hip torques of which were controlled using the PD-CTC to minimize the position error. The proposed scheme can be effectively used for neurofeedback training and rehabilitation of lower-limb amputees and paralyzed patients.


Subject(s)
Artificial Limbs , Brain-Computer Interfaces , Exoskeleton Device , Neurological Rehabilitation , Robotics , Spectroscopy, Near-Infrared/methods , Adult , Discriminant Analysis , Humans , Male , Neurological Rehabilitation/instrumentation , Neurological Rehabilitation/methods , Spectroscopy, Near-Infrared/instrumentation , Support Vector Machine
7.
Front Neurorobot ; 11: 33, 2017.
Article in English | MEDLINE | ID: mdl-28769781

ABSTRACT

In this paper, a novel methodology for enhanced classification of functional near-infrared spectroscopy (fNIRS) signals utilizable in a two-class [motor imagery (MI) and rest; mental rotation (MR) and rest] brain-computer interface (BCI) is presented. First, fNIRS signals corresponding to MI and MR are acquired from the motor and prefrontal cortex, respectively, afterward, filtered to remove physiological noises. Then, the signals are modeled using the general linear model, the coefficients of which are adaptively estimated using the least squares technique. Subsequently, multiple feature combinations of estimated coefficients were used for classification. The best classification accuracies achieved for five subjects, for MI versus rest are 79.5, 83.7, 82.6, 81.4, and 84.1% whereas those for MR versus rest are 85.5, 85.2, 87.8, 83.7, and 84.8%, respectively, using support vector machine. These results are compared with the best classification accuracies obtained using the conventional hemodynamic response. By means of the proposed methodology, the average classification accuracy obtained was significantly higher (p < 0.05). These results serve to demonstrate the feasibility of developing a high-classification-performance fNIRS-BCI.

8.
Neurosci Lett ; 647: 61-66, 2017 04 24.
Article in English | MEDLINE | ID: mdl-28336339

ABSTRACT

In this paper, a novel technique for determination of the optimal feature combinations and, thereby, acquisition of the maximum classification performance for a functional near-infrared spectroscopy (fNIRS)-based brain-computer interface (BCI), is proposed. After obtaining motor-imagery and rest signals from the motor cortex, filtering is applied to remove the physiological noises. Six features (signal slope, signal mean, signal variance, signal peak, signal kurtosis and signal skewness) are then extracted from the oxygenated hemoglobin (HbO). Afterwards, the hybrid genetic algorithm (GA)-support vector machine (SVM) is applied in order to determine and classify 2- and 3-feature combinations across all subjects. The SVM classifier is applied to classify motor imagery versus rest. Moreover, four time windows (0-20s, 0-10s, 11-20s and 6-15s) are selected, and the hybrid GA-SVM is applied in order to extract the optimal 2- and 3-feature combinations. In the present study, the 11-20s time window showed significantly higher classification accuracies - the minimum accuracy was 91% - than did the other time windows (p<0.05). The proposed hybrid GA-SVM technique, by selecting optimal feature combinations for an fNIRS-based BCI, shows positive classification-performance-enhancing results.


Subject(s)
Brain-Computer Interfaces , Motor Cortex/physiology , Spectroscopy, Near-Infrared/methods , Adult , Algorithms , Humans , Imagination , Male , Support Vector Machine
9.
Int Sch Res Notices ; 2017: 2725850, 2017.
Article in English | MEDLINE | ID: mdl-29360109

ABSTRACT

[This corrects the article DOI: 10.1155/2013/139273.].

10.
Int Sch Res Notices ; 2017: 6138754, 2017.
Article in English | MEDLINE | ID: mdl-29360112

ABSTRACT

[This corrects the article DOI: 10.1155/2013/521396.].

11.
ACG Case Rep J ; 2(3): 155-7, 2015 Apr.
Article in English | MEDLINE | ID: mdl-26157948

ABSTRACT

Upper gastrointestinal (GI) bleeding can be a rare manifestation of primary or metastatic tumor in the stomach. Tumors that commonly metastasize to stomach include breast, lung, and malignant melanoma. Laryngeal cancer usually metastasizes to the lung and cervical spine. We report the first case of upper GI bleed as a manifestation of laryngeal cancer in the stomach.

12.
J Coll Physicians Surg Pak ; 23(3): 231-3, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23458054

ABSTRACT

Dengue fever has now affected all the major cities of country. About 41,354 patients underwent antibody screening for dengue fever from Shaukat Khanum Memorial Cancer Hospital, Lahore, during the epidemic period (October 1st 2010 to December 20th 2010). Out of them, 1294 (3.1%) patients were positive for IgM antibodies, and 124 (0.3%) for IgG antibodies. A total of 722 (1.7%) patients were borderline positive for IgM antibodies and 108 (0.26%) were borderline positive for IgG antibodies. Dengue fever has emerged as a global problem over the last 5 years. It has also hit Lahore badly especially after the floods in 2010. High index of suspicion should be there in case of related symptoms.


Subject(s)
Dengue Virus/isolation & purification , Dengue/diagnosis , Dengue/epidemiology , Disease Outbreaks , Immunoglobulin G/blood , Immunoglobulin M/blood , Antibodies, Viral/blood , Biomarkers/blood , Dengue/blood , Dengue Virus/immunology , Female , Humans , Male , Pakistan/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL