Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 178
Filter
1.
Eur Heart J ; 2024 May 15.
Article in English | MEDLINE | ID: mdl-38747561

ABSTRACT

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all (100%; 95% confidence interval [CI] 94-100.0%, p<0.001) patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 (98.3%; 95% CI [91.1-100%]) patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1-99.0%). Within 90 days, freedom from mortality was 95% (95% CI 86.1-99.0%]), without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favorable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.

2.
Circ Cardiovasc Interv ; : e013842, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38708595

ABSTRACT

BACKGROUND: An increasing number of interventional procedures require large-sheath technology (>12F) with a favorable outcome with endovascular rather than open surgical access. However, vascular complications are a limitation for the management of these patients. This trial aimed to determine the effectiveness and safety of the Cross-Seal suture-mediated vascular closure device in obtaining hemostasis at the target limb access site following interventional procedures using 8F to 18F procedural sheaths. METHODS: The Cross-Seal IDE trial (Investigational Device Exemption) was a prospective, single-arm, multicenter study in subjects undergoing percutaneous endovascular procedures utilizing 8F to 18F ID procedural sheaths. The primary efficacy end point was time to hemostasis at the target limb access site. The primary safety end point was freedom from major complications of the target limb access site within 30 days post procedure. RESULTS: A total of 147 subjects were enrolled between August 9, 2019, and March 12, 2020. Transcatheter aortic valve replacement was performed in 53.7% (79/147) and percutaneous endovascular abdominal/thoracic aortic aneurysm repair in 46.3% (68/147) of subjects. The mean sheath ID was 15.5±1.8 mm. The primary effectiveness end point of time to hemostasis was 0.4±1.4 minutes. An adjunctive intervention was required in 9.2% (13/142) of subjects, of which 2.1% (3/142) were surgical and 5.6% (8/142) endovascular. Technical success was achieved in 92.3% (131/142) of subjects. Freedom from major complications of the target limb access site was 94.3% (83/88). CONCLUSIONS: In selected patients undergoing percutaneous endovascular procedures utilizing 8F to 18F ID procedural sheath, Cross-Seal suture-mediated vascular closure device achieved favorable effectiveness and safety in the closure of the large-bore arteriotomy. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03756558.

3.
JACC Cardiovasc Interv ; 17(7): 874-886, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38599690

ABSTRACT

BACKGROUND: Adequate valve performance after surgical mitral valve repair with an annuloplasty ring is not always sustained over time. The risk of repeat mitral valve surgery may be high in these patients. Transcatheter mitral valve-in-ring (MViR) is emerging as an alternative for high-risk patients. OBJECTIVES: The authors sought to assess contemporary outcomes of MViR using third-generation balloon-expandable aortic transcatheter heart valves. METHODS: Patients who underwent MViR and were enrolled in the STDS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) Registry between August 2015 and December 2022 were analyzed. RESULTS: A total of 820 patients underwent MViR at 236 sites, mean age was 72.2 ± 10.4 years, 50.9% were female, mean STS score was 8.2% ± 6.9%, and most (78%) were in NYHA functional class III to IV. Mean left ventricular ejection fraction was 47.8% ± 14.2%, mean mitral gradient was 8.9 ± 7.0 mm Hg, and 75.5% had ≥ moderate mitral regurgitation. Access was transseptal in 93.9% with 88% technical success. All-cause mortality at 30 days was 8.3%, and at 1 year, 22.4%, with a reintervention rate of 9.1%. At 1-year follow-up, 75.6% were NYHA functional class I to II, Kansas City Cardiomyopathy Questionnaire score increased by 25.9 ± 29.1 points, mean mitral valve gradient was 8.4 ± 3.4 mm Hg, and 91.7% had ≤ mild mitral regurgitation. CONCLUSIONS: MViR with third-generation balloon-expandable aortic transcatheter heart valves is associated with a significant reduction in mitral regurgitation and improvement in symptoms at 1 year, but with elevated valvular gradients and a high reintervention rate. MViR is a reasonable alternative for high-risk patients unable undergo surgery who have appropriate anatomy for the procedure. (STS/ACC TVT Registry Mitral Module [TMVR]; NCT02245763).


Subject(s)
Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve Insufficiency/etiology , Stroke Volume , Treatment Outcome , Ventricular Function, Left , Cardiac Catheterization/methods
4.
JACC Cardiovasc Interv ; 17(3): 391-401, 2024 Feb 12.
Article in English | MEDLINE | ID: mdl-38355267

ABSTRACT

BACKGROUND: Although permanent pacemaker (PPM) implantation is a common complication of transcatheter aortic valve replacement (TAVR), hospital variation and change in PPM implantation rates are ill defined. OBJECTIVES: The aim of this study was to determine hospital-level variation and temporal trends in the rate of PPM implantation following TAVR. METHODS: Using the American College of Cardiology/Society of Thoracic Surgeons TVT (Transcatheter Valve Therapy) Registry, temporal changes in variation of in-hospital and 30-day PPM implantation were determined among 184,452 TAVR procedures across 653 sites performed from 2016 to 2020. The variation in PPM implantation adjusted for valve type by annualized TAVR volume was determined, and characteristics of sites below, within, and above the 95% boundary were identified. A series of stepwise multivariable hierarchical models were then fit, and the median OR was used to measure variation in pacemaker rates among sites. RESULTS: From 2016 to 2020, the overall rate of PPM implantation was 11.3%, with wide variation across sites (range: 0%-36.4%); rates trended lower over time. Adjusted for annualized volume, there were 34 sites with PPM implantation rates above the 95th percentile CI and 28 with rates below, with wide variation among the remaining sites. After adjusting for patient-level covariates, there was variation among sites in the probability of PPM implantation (median OR: 1.39; 95% CI: 1.35-1.43, P < 0.001); although some of the variation was explained by the addition of valve type, residual variation in PPM implantation rates persisted in additional models incorporating site-level covariates (annualized volume, region, teaching status, hospital beds, etc). CONCLUSIONS: Although PPM implantation rates have decreased over time, substantial site-level variation remains even after accounting for observed patient characteristics and site-level factors. As there are numerous outlier sites both above and below the 95% confidence limit, dissemination of best practices from high-performing sites to low-performing sites and guideline-based education may be important quality improvement initiatives to reduce rates of this common complication.


Subject(s)
Aortic Valve Stenosis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Treatment Outcome , Risk Factors , Registries , Aortic Valve/diagnostic imaging , Aortic Valve/surgery
5.
EuroIntervention ; 20(3): e207-e215, 2024 Feb 05.
Article in English | MEDLINE | ID: mdl-38343369

ABSTRACT

BACKGROUND: Outcomes after percutaneous coronary intervention (PCI) for de novo ostial right coronary artery (RCA) lesions are poor. AIMS: We used intravascular ultrasound (IVUS) to clarify the morphological patterns of de novo ostial RCA lesions and their associated clinical outcome. METHODS: Among 5,102 RCA IVUS studies, 170 de novo ostial RCA stenoses (within 3 mm from the aorto-ostium) were identified. These were classified as 1) isolated ostial lesions (no disease extending beyond 10 mm from the ostium and without a calcified nodule [CN]); 2) ostial CN, typically with diffuse disease (disease extending beyond 10 mm); and 3) ostial lesions with diffuse disease but without a CN. The primary outcome was target lesion failure (TLF: cardiac death, target vessel myocardial infarction, definite stent thrombosis, and ischaemia-driven target lesion revascularisation). RESULTS: The prevalence of an isolated ostial lesion was 11.8% (n=20), 47.6% (n=81) were ostial CN, and 40.6% (n=69) were ostial lesions with diffuse disease. Compared to ostial lesions with diffuse disease, isolated lesions were more common in women (75.0% vs 42.0%; p=0.01), and CN were associated with older age (median [first, third quartile] 76 [70, 83] vs 69 [63, 81] years old; p=0.002). The Kaplan-Meier rate of TLF at 2 years was significantly higher in patients with CN (21.6%) compared to diffuse lesions (8.2%) (p=0.04), and patients with isolated lesions had no events. A multivariable Cox proportional hazard model revealed that CN were significantly associated with TLF (hazard ratio 6.63, 95% confidence interval: 1.28-34.3; p=0.02). CONCLUSIONS: Ostial RCA lesions have specific morphologies - detectable by IVUS - that may be associated with long-term clinical outcomes.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Humans , Female , Aged, 80 and over , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Artery Disease/etiology , Percutaneous Coronary Intervention/adverse effects , Treatment Outcome , Risk Factors , Coronary Angiography
6.
JACC Cardiovasc Interv ; 17(4): 491-501, 2024 Feb 26.
Article in English | MEDLINE | ID: mdl-38340105

ABSTRACT

BACKGROUND: Intravascular ultrasound (IVUS) studies show that one-quarter of left anterior descending (LAD) arteries have a myocardial bridge. An MB may be associated with stent failure when the stent extends into the MB. OBJECTIVES: The aim of this study was to investigate: 1) the association between an MB and chronic total occlusion (CTO) in any LAD lesions; and 2) the association between an MB and subsequent clinical outcomes after percutaneous coronary intervention in LAD CTOs. METHODS: A total of 3,342 LAD lesions with IVUS-guided percutaneous coronary intervention (280 CTO and 3,062 non-CTO lesions) were included. The primary outcome was target lesion failure (cardiac death, target vessel myocardial infarction, definite stent thrombosis, and ischemic-driven target lesion revascularization). RESULTS: An MB by IVUS was significantly more prevalent in LAD CTOs than LAD non-CTOs (40.4% [113/280] vs 25.8% [789/3,062]; P < 0.0001). The discrepancy in CTO length between angiography and IVUS was greater in 113 LAD CTOs with an MB than 167 LAD CTOs without an MB (6.0 [Q1, Q3: 0.1, 12.2] mm vs 0.2 [Q1, Q3: -1.4, 8.4] mm; P < 0.0001). Overall, 48.7% (55/113) of LAD CTOs had a stent that extended into an MB after which target lesion failure was significantly higher compared to a stent that did not extend into an MB (26.3% vs 0%; P = 0.0004) or compared to an LAD CTO without an MB (26.3% vs 9.6%; P = 0.02). CONCLUSIONS: An MB was more common in LAD CTO than non-CTO LAD lesions. If present, approximately one-half of LAD CTOs had a stent extending into an MB that, in turn, was associated with worse outcomes.


Subject(s)
Coronary Occlusion , Myocardial Infarction , Percutaneous Coronary Intervention , Humans , Coronary Occlusion/diagnostic imaging , Coronary Occlusion/therapy , Treatment Outcome , Percutaneous Coronary Intervention/adverse effects , Coronary Angiography , Chronic Disease
7.
Am J Med ; 137(4): 321-330.e7, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38190959

ABSTRACT

PURPOSE: There are concerns that transcatheter or surgical aortic valve replacement (TAVR/SAVR) procedures are preferentially available to White patients. Our objective was to examine differences in utilization of aortic valve replacement and outcomes by race/ethnicity in the US for patients with aortic stenosis. METHODS: We performed a serial cross-sectional cohort study of 299,976 Medicare beneficiaries hospitalized with principal diagnosis of aortic stenosis between 2012 and 2019 stratified by self-reported race/ethnicity (Black, Hispanic, Asian, Native American, and White). Outcomes included aortic valve replacement rates within 6 months of index hospitalization and associated procedural outcomes, including 30-day readmission, 30-day and 1-year mortality. RESULTS: Within 6 months of an index admission for aortic stenosis, 86.8% (122,457 SAVR; 138,026 TAVR) patients underwent aortic valve replacement. Overall, compared with White people, Black (HR 0.87 [0.85-0.89]), Hispanic (0.92 [0.88-0.96]), and Asian (0.95 [0.91-0.99]) people were less likely to receive aortic valve replacement. Among patients who were admitted emergently/urgently, White patients (41.1%, 95% CI, 40.7-41.4) had a significantly higher aortic valve replacement rate compared with Black (29.6%, 95% CI, 28.3-30.9), Hispanic (36.6%, 95% CI, 34.0-39.3), and Asian patients (35.4%, 95% CI, 32.3-38.9). Aortic valve replacement rates increased annually for all race/ethnicities. There were no significant differences in 30-day or 1-year mortality by race/ethnicity. CONCLUSIONS: Aortic valve replacement rates within 6 months of aortic stenosis admission are lower for Black, Hispanic, and Asian people compared to White people. These race-related differences in aortic stenosis treatment reflect complex issues in diagnosis and management, warranting a comprehensive reassessment of the entire care spectrum for disadvantaged populations.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Humans , Aged , United States/epidemiology , Aortic Valve/surgery , Cross-Sectional Studies , Medicare , Treatment Outcome , Aortic Valve Stenosis/surgery , Risk Factors
8.
EuroIntervention ; 20(2): e146-e157, 2024 Jan 15.
Article in English | MEDLINE | ID: mdl-38224255

ABSTRACT

BACKGROUND: There are limited data on the impact of transcatheter heart valve (THV) type on the outcomes of surgical explantation after THV failure. AIMS: We sought to determine the outcomes of transcatheter aortic valve replacement (TAVR) explantation for failed balloon-expandable valves (BEV) versus self-expanding valves (SEV). METHODS: From November 2009 to February 2022, 401 patients across 42 centres in the EXPLANT-TAVR registry underwent TAVR explantation during a separate admission from the initial TAVR. Mechanically expandable valves (N=10, 2.5%) were excluded. The outcomes of TAVR explantation were compared for 202 (51.7%) failed BEV and 189 (48.3%) failed SEV. RESULTS: Among 391 patients analysed (mean age: 73.0±9.8 years; 33.8% female), the median time from index TAVR to TAVR explantation was 13.3 months (interquartile range 5.1-34.8), with no differences between groups. Indications for TAVR explantation included endocarditis (36.0% failed SEV vs 55.4% failed BEV; p<0.001), paravalvular leak (21.2% vs 11.9%; p=0.014), structural valve deterioration (30.2% vs 21.8%; p=0.065) and prosthesis-patient mismatch (8.5% vs 10.4%; p=0.61). The SEV group trended fewer urgent/emergency surgeries (52.0% vs 62.3%; p=0.057) and more root replacement (15.3% vs 7.4%; p=0.016). Concomitant cardiac procedures were performed in 57.8% of patients, including coronary artery bypass graft (24.8%), and mitral (38.9%) and tricuspid (14.6%) valve surgery, with no differences between groups. In-hospital, 30-day, and 1-year mortality and stroke rates were similar between groups (allp>0.05), with no differences in cumulative mortality at 3 years (log-rank p=0.95). On multivariable analysis, concomitant mitral surgery was an independent predictor of 1-year mortality after BEV explant (hazard ratio [HR] 2.00, 95% confidence interval [CI]: 1.07-3.72) and SEV explant (HR 2.00, 95% CI: 1.08-3.69). CONCLUSIONS: In the EXPLANT-TAVR global registry, BEV and SEV groups had different indications for surgical explantation, with more root replacements in SEV failure, but no differences in midterm mortality and morbidities. Further refinement of TAVR explantation techniques are important to improving outcomes.


Subject(s)
Transcatheter Aortic Valve Replacement , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Transcatheter Aortic Valve Replacement/adverse effects , Device Removal , Catheters , Heart Valves , Registries
9.
Catheter Cardiovasc Interv ; 103(2): 367-375, 2024 02.
Article in English | MEDLINE | ID: mdl-37890014

ABSTRACT

AIMS: Characterize the impact of residual tricuspid regurgitation (TR) on right ventricle (RV) remodeling and clinical outcomes after transcatheter tricuspid valve intervention. METHODS: We performed a single-center retrospective analysis of transcatheter tricuspid valve repair (TTVr) or replacement (TTVR) patients. The primary outcomes were longitudinal tricuspid annular plane systolic excursion (TAPSE), fractional area change (FAC), pulmonary artery systolic pressure (PASP), and RV dimensions (RVd). We used multivariable linear mixed models to evaluate association with replacement versus repair and degree of TR reduction with changes in these echo measures over time. Multivariable Cox regression was used to identify associations between changes in these echo measures and a composite clinical outcome of death, heart failure hospitalization, or re-do tricuspid valve intervention. RESULTS: We included a total of 61 patients; mean age was 77.5 ± 11.7 and 62% were female. TTVR was performed in 25 (41%) and TTVr in 36 (59%). Initially, 72% (n = 44) had ≤ severe TR and 28% (n = 17) had massive or torrential TR. The median number of follow up echos was 2: time to 1st follow-up was 50 days (interquartile range [IQR]: 20, 91) and last follow-up was 147 (IQR: 90, 327). Median TR reduction was 1 (IQR: 0, 2) versus 4 (IQR: 3, 6) grades in TTVr versus TTVR (p < 0.0001). In linear mixed modeling, TTVR was associated with decline in TAPSE and PASP, and TR reduction was associated with decreased RVd. In multivariable Cox regression, greater RVd was associated with the clinical outcome (hazard ratio: 9.27, 95% confidence interval: 1.23-69.88, p = 0.03). CONCLUSION: Greater TR reduction is achieved by TTVR versus TTVr, which is in turn associated with RV reverse remodeling. RV dimension in follow-up is associated with increased risk of a composite outcome of death, heart failure hospitalization, or re-do tricuspid valve intervention.


Subject(s)
Heart Failure , Tricuspid Valve Insufficiency , Humans , Female , Aged , Aged, 80 and over , Male , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Retrospective Studies , Ventricular Remodeling , Treatment Outcome , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/complications , Heart Failure/diagnostic imaging , Heart Failure/therapy
10.
JACC Case Rep ; 25: 102031, 2023 Nov 01.
Article in English | MEDLINE | ID: mdl-38094204

ABSTRACT

Mitral valve replacement in the setting of extensive mitral annular calcification is technically challenging and associated with high mortality and morbidity, including stroke. This is the first published report of direct surgical transcatheter valve implantation with use of a cerebral embolic protection device. (Level of Difficulty: Intermediate.).

11.
Struct Heart ; 7(6): 100213, 2023 Nov.
Article in English | MEDLINE | ID: mdl-38046859

ABSTRACT

Transcatheter aortic valve replacement (TAVR) is continually evolving, with a recent emphasis on a "minimalist" approach toward reducing procedural invasiveness, duration, and recovery time. Whereas a better understanding of the relationship between TAVR and new conduction disturbances has led to improved periprocedural management, intraprocedural rapid-pacing techniques have not evolved beyond traditional right ventricular temporary pacing. An alternative strategy utilizing the left ventricular guidewire for rapid pacing has been developed with evidence supporting its safety, effectiveness, and potential reductions in procedure time and cost. This review will outline the current best practices in left ventricular pacing for TAVR, a practical technique that embraces the minimalist approach to TAVR and may be considered for routine use. It aims to explore the current evidence and combine this with expert opinion to offer a strategy for temporary pacing that encourages efficiencies for physicians and patients without compromising periprocedural safety.

12.
J Med Internet Res ; 25: e47475, 2023 11 10.
Article in English | MEDLINE | ID: mdl-37948098

ABSTRACT

BACKGROUND: Accurate, timely ascertainment of clinical end points, particularly hospitalizations, is crucial for clinical trials. The Tailored Antiplatelet Initiation to Lessen Outcomes Due to Decreased Clopidogrel Response after Percutaneous Coronary Intervention (TAILOR-PCI) Digital Study extended the main TAILOR-PCI trial's follow-up to 2 years, using a smartphone-based research app featuring geofencing-triggered surveys and routine monthly mobile phone surveys to detect cardiovascular (CV) hospitalizations. This pilot study compared these digital tools to conventional site-coordinator ascertainment of CV hospitalizations. OBJECTIVE: The objectives were to evaluate geofencing-triggered notifications and routine monthly mobile phone surveys' performance in detecting CV hospitalizations compared to telephone visits and health record reviews by study coordinators at each site. METHODS: US and Canadian participants from the TAILOR-PCI Digital Follow-Up Study were invited to download the Eureka Research Platform mobile app, opting in for location tracking using geofencing, triggering a smartphone-based survey if near a hospital for ≥4 hours. Participants were sent monthly notifications for CV hospitalization surveys. RESULTS: From 85 participants who consented to the Digital Study, downloaded the mobile app, and had not previously completed their final follow-up visit, 73 (85.8%) initially opted in and consented to geofencing. There were 9 CV hospitalizations ascertained by study coordinators among 5 patients, whereas 8 out of 9 (88.9%) were detected by routine monthly hospitalization surveys. One CV hospitalization went undetected by the survey as it occurred within two weeks of the previous event, and the survey only allowed reporting of a single hospitalization. Among these, 3 were also detected by the geofencing algorithm, but 6 out of 9 (66.7%) were missed by geofencing: 1 occurred in a participant who never consented to geofencing, while 5 hospitalizations occurred among participants who had subsequently turned off geofencing prior to their hospitalization. Geofencing-detected hospitalizations were ascertained within a median of 2 (IQR 1-3) days, monthly surveys within 11 (IQR 6.5-25) days, and site coordinator methods within 38 (IQR 9-105) days. The geofencing algorithm triggered 245 notifications among 39 participants, with 128 (52.2%) from true hospital presence and 117 (47.8%) from nonhospital health care facility visits. Additional geofencing iterative improvements to reduce hospital misidentification were made to the algorithm at months 7 and 12, elevating the rate of true alerts from 35.4% (55 true alerts/155 total alerts before month 7) to 78.7% (59 true alerts/75 total alerts in months 7-12) and ultimately to 93.3% (14 true alerts/5 total alerts in months 13-21), respectively. CONCLUSIONS: The monthly digital survey detected most CV hospitalizations, while the geofencing survey enabled earlier detection but did not offer incremental value beyond traditional tools. Digital tools could potentially reduce the burden on study coordinators in ascertaining CV hospitalizations. The advantages of timely reporting via geofencing should be weighed against the issue of false notifications, which can be mitigated through algorithmic refinements.


Subject(s)
Percutaneous Coronary Intervention , Humans , Clopidogrel/therapeutic use , Follow-Up Studies , Pilot Projects , Canada , Hospitalization
13.
Catheter Cardiovasc Interv ; 102(2): 328-338, 2023 08.
Article in English | MEDLINE | ID: mdl-37393603

ABSTRACT

BACKGROUND: Valve-in-valve (VIV) transcatheter aortic valve implantation (TAVI) is a less invasive therapeutic option compared with redo surgical valve replacement for high-risk patients. Relative to procedures within stented surgical valves, VIV-TAVI within stentless valves is associated with a higher complication rate due to challenging underlying anatomy and absence of fluoroscopic landmarks. AIMS: We share a single-center experience with VIV-TAVI in stentless valves, discussing our procedural insights and associated outcomes. METHODS: Our institutional database was queried, and 25 patients who had undergone VIV-TAVI within a stentless bioprosthesis, homograft, or valve-sparing aortic root replacement between 2013 and 2022 were found. Outcome endpoints were based on the Valve Academic Research Consortium-3 criteria. RESULTS: The mean age of the cohort was 69.5 ± 13.6 years. VIV implantation was performed within a homograft in 11 patients, a stentless bioprothesis in 10 patients, and a valve-sparing aortic root replacement in 4 patients. Nineteen (76%) balloon-expandable valves, 5 (20%) self-expanding valves, and one mechanically-expandable (4%) valve were implanted with 100% procedural success, with no instances of significant paravalvular leak, coronary occlusion, or device embolization. There was one (4%) in-hospitality mortality after an emergency procedure; one (4%) patient experienced a transient ischemic attack; and two (8%) patients required permanent pacemaker implantation. The median length of hospital stay was 2 days. After a median follow-up time of 16.5 months, valve function was acceptable in all patients with available data. CONCLUSION: VIV-TAVI within stentless valves can be safely performed with methodical procedural technique and can provide clinical benefit in patients at high reoperation risk.


Subject(s)
Aortic Valve Stenosis , Bioprosthesis , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Middle Aged , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Treatment Outcome , Prosthesis Design , Aortic Valve Stenosis/surgery
14.
EuroIntervention ; 19(5): e383-e393, 2023 Aug 07.
Article in English | MEDLINE | ID: mdl-37283548

ABSTRACT

BACKGROUND: Despite a high rate of in-stent restenosis (ISR) after stenting the right coronary artery (RCA) ostium, the mechanism of ostial RCA ISR is not well understood. AIMS: We aimed to clarify the cause of ostial RCA ISR using intravascular ultrasound (IVUS). METHODS: Overall, 139 ostial RCA ISR lesions were identified with IVUS, pre-revascularisation. Primary ISR mechanisms were classified as follows: 1) neointimal hyperplasia (NIH); 2) neoatherosclerosis; 3) ostium not covered by the stent; 4) stent fracture or deformation; 5) stent underexpansion (old minimum stent area <4.0 mm2 or stent expansion <50%); or 6) a protruding calcified nodule. RESULTS: The median duration from prior stenting was 1.2 (first quartile 0.6, third quartile 3.1) years. The primary mechanisms of ISR were NIH in 25% (n=35) of lesions, neoatherosclerosis in 22% (n=30), uncovered ostium in 6% (n=9) (biological cause 53%, n=74), stent fracture or deformation in 25% (n=35), underexpansion in 11% (n=15), and protruding calcified nodules in 11% (n=15) (mechanical cause 47%, n=65). Including secondary mechanisms, 51% (n=71) of ostial RCA ISRs had stent fractures that were associated with greater hinge motion of the ostial-aorta angle during the cardiac cycle. The Kaplan-Meier rate of target lesion failure at 1 year was 11.5%. When the mechanically caused ISRs were treated without new stents, they suffered a higher subsequent event rate (41.4%) compared with non-mechanical causes or mechanical causes treated without restenting (7.8%, unadjusted hazard ratio 6.44, 95% confidence interval: 2.33-17.78; p<0.0001). CONCLUSIONS: Half of the ostial RCA ISRs were due to mechanical causes. Subsequent event rates were high, especially in mechanically caused ISRs treated without the implantation of a new stent.


Subject(s)
Coronary Restenosis , Humans , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Coronary Restenosis/therapy , Coronary Vessels/diagnostic imaging , Coronary Vessels/surgery , Coronary Angiography/adverse effects , Treatment Outcome , Stents/adverse effects
15.
JACC Cardiovasc Interv ; 16(10): 1176-1188, 2023 05 22.
Article in English | MEDLINE | ID: mdl-37225288

ABSTRACT

BACKGROUND: Although >150,000 mitral TEER procedures have been performed worldwide, the impact of MR etiology on MV surgery after TEER remains unknown. OBJECTIVES: The authors sought to compare outcomes of mitral valve (MV) surgery after failed transcatheter edge-to-edge repair (TEER) stratified by mitral regurgitation (MR) etiology. METHODS: Data from the CUTTING-EDGE registry were retrospectively analyzed. Surgeries were stratified by MR etiology: primary (PMR) and secondary (SMR). MVARC (Mitral Valve Academic Research Consortium) outcomes at 30 days and 1 year were evaluated. Median follow-up was 9.1 months (IQR: 1.1-25.8 months) after surgery. RESULTS: From July 2009 to July 2020, 330 patients underwent MV surgery after TEER, of which 47% had PMR and 53.0% had SMR. Mean age was 73.8 ± 10.1 years, median STS risk at initial TEER was 4.0% (IQR: 2.2%-7.3%). Compared with PMR, SMR had a higher EuroSCORE, more comorbidities, lower LVEF pre-TEER and presurgery (all P < 0.05). SMR patients had more aborted TEER (25.7% vs 16.3%; P = 0.043), more surgery for mitral stenosis after TEER (19.4% vs 9.0%; P = 0.008), and fewer MV repairs (4.0% vs 11.0%; P = 0.019). Thirty-day mortality was numerically higher in SMR (20.4% vs 12.7%; P = 0.072), with an observed-to-expected ratio of 3.6 (95% CI: 1.9-5.3) overall, 2.6 (95% CI: 1.2-4.0) in PMR, and 4.6 (95% CI: 2.6-6.6) in SMR. SMR had significantly higher 1-year mortality (38.3% vs 23.2%; P = 0.019). On Kaplan-Meier analysis, the actuarial estimates of cumulative survival were significantly lower in SMR at 1 and 3 years. CONCLUSIONS: The risk of MV surgery after TEER is nontrivial, with higher mortality after surgery, especially in SMR patients. These findings provide valuable data for further research to improve these outcomes.


Subject(s)
Mitral Valve Insufficiency , Humans , Middle Aged , Aged , Aged, 80 and over , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/surgery , Retrospective Studies , Treatment Outcome , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Registries
16.
Am J Cardiol ; 196: 22-30, 2023 06 01.
Article in English | MEDLINE | ID: mdl-37058874

ABSTRACT

Adverse outcomes in tricuspid regurgitation (TR) have been associated with advanced regurgitation severity and right-sided cardiac remodeling, and late referrals for tricuspid valve surgery in TR have been associated with increase in postoperative mortality. The purpose of this study was to evaluate baseline characteristics, clinical outcomes, and procedural utilization of a TR referral population. We analyzed patients with a diagnosis of TR referred to a large TR referral center between 2016 and 2020. We evaluated baseline characteristics stratified by TR severity and analyzed time-to-event outcomes for a composite of overall mortality or heart-failure hospitalization. In total, 408 patients were referred with a diagnosis of TR: the median age of the cohort was 79 years (interquartile range 70 to 84), and 56% were female. In patients evaluated on a 5-grade scale, 10.2% had ≤moderate TR; 30.7% had severe TR; 11.4% had massive TR, and 47.7% had torrential TR. Increasing TR severity was associated with right-sided cardiac remodeling and altered right ventricular hemodynamics. In multivariable Cox regression analysis, New York Heart Association class symptoms, history of heart failure hospitalization, and right atrial pressure were associated with the composite outcome. One-third of patients referred underwent transcatheter tricuspid valve intervention (19%) or surgery (14%); patients who underwent transcatheter tricuspid valve intervention had greater preoperative risk than that of patients who underwent surgery. In conclusion, in patients referred for evaluation of TR, there were high rates of massive and torrential regurgitation and advanced right ventricle remodeling. Symptoms and right atrial pressure are associated with clinical outcomes in follow-up. There were significant differences in baseline procedural risk and eventual therapeutic modality.


Subject(s)
Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Female , Aged , Male , Tricuspid Valve Insufficiency/epidemiology , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/diagnosis , Ventricular Remodeling , Heart Valve Prosthesis Implantation/adverse effects , Treatment Outcome , Tricuspid Valve/surgery , Severity of Illness Index , Cardiac Catheterization/adverse effects
17.
Eur Heart J ; 44(15): 1331-1339, 2023 04 17.
Article in English | MEDLINE | ID: mdl-36883599

ABSTRACT

AIMS: Paravalvular regurgitation (PVR) after transcatheter aortic valve implantation (TAVI) is associated with increased morbidity and mortality. The effect of transcatheter interventions to treat PVR after the index TAVI was investigated. METHODS AND RESULTS: A registry of consecutive patients who underwent transcatheter intervention for ≥ moderate PVR after the index TAVI at 22 centers. The principal outcomes were residual aortic regurgitation (AR) and mortality at 1 year after PVR treatment. A total of 201 patients were identified: 87 (43%) underwent redo-TAVI, 79 (39%) plug closure, and 35 (18%) balloon valvuloplasty. Median TAVI-to-re-intervention time was 207 (35; 765) days. The failed valve was self-expanding in 129 (63.9%) patients. The most frequent devices utilized were a Sapien 3 valve for redo-TAVI (55, 64%), an AVP II as plug (33, 42%), and a True balloon for valvuloplasty (20, 56%). At 30 days, AR ≥ moderate persisted in 33 (17.4%) patients: 8 (9.9%) after redo-TAVI, 18 (25.9%) after plug, and 7 (21.9%) after valvuloplasty (P = 0.036). Overall mortality was 10 (5.0%) at 30 days and 29 (14.4%) at 1 year: 0, 8 (10.1%), and 2 (5.7%) at 30 days (P = 0.010) and 11 (12.6%), 14 (17.7%), and 4 (11.4%) at 1 year (P = 0.418), after redo-TAVI, plug, and valvuloplasty, respectively. Regardless of treatment strategy, patients in whom AR was reduced to ≤ mild had lower mortality at 1 year compared with those with AR persisting ≥ moderate [11 (8.0%) vs. 6 (21.4%); P = 0.007]. CONCLUSION: This study describes the efficacy of transcatheter treatments for PVR after TAVI. Patients in whom PVR was successfully reduced had better prognosis. The selection of patients and the optimal PVR treatment modality require further investigation.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Prognosis , Treatment Outcome , Aortic Valve Insufficiency/etiology , Aortic Valve Insufficiency/surgery
18.
JACC Cardiovasc Interv ; 16(5): 558-570, 2023 03 13.
Article in English | MEDLINE | ID: mdl-36922042

ABSTRACT

BACKGROUND: Procedural success and clinical outcomes after transcatheter aortic valve replacement (TAVR) have improved, but residual aortic regurgitation (AR) and new permanent pacemaker implantation (PPI) rates remain variable because of a lack of uniform periprocedural management and implantation. OBJECTIVES: The Optimize PRO study evaluates valve performance and procedural outcomes using an "optimized" TAVR care pathway and the cusp overlap technique (COT) in patients receiving the Evolut PRO/PRO+ (Medtronic) self-expanding valves. METHODS: Optimize PRO, a nonrandomized, prospective, postmarket study conducted in the United States, Canada, Europe, Middle East, and Australia, is enrolling patients with severe symptomatic aortic stenosis and no pre-existing pacemaker. Sites follow a standardized TAVR care pathway, including early discharge and a conduction disturbance management algorithm, and transfemoral deployment using the COT. RESULTS: A total of 400 attempted implants from the United States and Canada comprised the main cohort of this second interim analysis. The mean age was 78.7 ± 6.6 years, and the mean Society of Thoracic Surgeons predictive risk of mortality was 3.0 ± 2.4. The median length of stay was 1 day. There were no instances of moderate or severe AR at discharge. At 30 days, all-cause mortality or stroke was 3.8%, all-cause mortality was 0.8%, disabling stroke was 0.7%, hospital readmission was 10.1%, and cardiovascular rehospitalization was 6.1%. The new PPI rate was 9.8%, 5.8% with 4-step COT compliance. In the multivariable model, right bundle branch block and the depth of the implant increased the risk of PPI, whereas using the 4-step COT lowered 30-day PPI. CONCLUSIONS: The use of the TAVR care pathway and COT resulted in favorable clinical outcomes with no moderate or severe AR and low PPI rates at 30 days while facilitating early discharge and reproducible outcomes across various sites and operators. (Optimize PRO; NCT04091048).


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Humans , United States , Aged , Aged, 80 and over , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Critical Pathways , Prospective Studies , Risk Factors , Treatment Outcome , Aortic Valve Insufficiency/etiology , Heart Valve Prosthesis/adverse effects
19.
JACC Cardiovasc Interv ; 16(3): 247-257, 2023 02 13.
Article in English | MEDLINE | ID: mdl-36792250

ABSTRACT

BACKGROUND: The COVID-19 pandemic and iodinated contrast shortage may have affected interventional cardiology (IC) fellowship training. OBJECTIVES: The aim of this study was to investigate the educational experience of first-year IC fellows in the United States and Canada. METHODS: A 59-question online survey was conducted among 2021-2022 first-year IC fellows in the United States and Canada. RESULTS: Of the 360 IC fellows invited to participate, 111 (31%) responded; 95% were from the United States, and 79% were men. Participants were mostly from university programs (70%), spent 61 to 70 hours/week in the hospital, and had an annual percutaneous coronary intervention case number of <200 (5%), 200 to 249 (8%), 250 to 349 (33%), 350 to 499 (39%), 500 to 699 (12%), or ≥700 (3%). For femoral access, a micropuncture needle was used regularly by 89% and ultrasound-guided puncture by 81%, and 43% used vascular closure devices in most cases (>80%). Intravascular ultrasound was performed and interpreted very comfortably by 62% and optical coherence tomography (OCT) by 32%, and 20% did not have access to OCT. Approximately one-third felt very comfortable performing various atherectomy techniques. Covered stents, fat embolization, and coil embolization were used very comfortably by 14%, 4%, and 3%, respectively. Embolic protection devices were used very comfortably by 11% to 24% of IC fellows. Almost one-quarter of fellows (24%) were warned about their high radiation exposure. Eighty-four percent considered IC fellowship somewhat or very stressful, and 16% reported inadequate psychological support. CONCLUSIONS: This survey highlights opportunities for improvement with regard to the use of intravascular imaging, atherectomy techniques, complication prevention and management strategies, radiation awareness and mitigation, and psychological support.


Subject(s)
COVID-19 , Cardiology , Male , Humans , United States , Female , Pandemics , COVID-19/epidemiology , Treatment Outcome , Education, Medical, Graduate/methods , Surveys and Questionnaires , Cardiology/education , Canada
SELECTION OF CITATIONS
SEARCH DETAIL
...