ABSTRACT

We study effects of oscillatory convective flow in extracellular space on the velocity of chemical signal propagation having a form of a front wave above a cellular layer. We found that the time-averaged propagation velocity under oscillatory flow for a particular Péclet number amplitude is slower than the velocity under steady laminar flow regime for the same value of the Péclet number, but significantly faster than under no-flow conditions. We derive asymptotic values of the propagation velocity and asymptotic characteristics of the corresponding concentration fronts in high- and low-frequency regimes and show that the reason for the observed velocity increase under the oscillatory flow stems from a nonlinear dependence of the propagation velocity on the Péclet number, particularly from the convex character of the dependence. Our findings suggest that the specific responses of cellular cultures to different flow conditions in the extracellular space (for example, expression of atherosclerosis protective genes under steady laminar flow but not under oscillatory flow) is a consequence of a nonlinear coupling between the extracellular transport and complex intracellular reaction cascades forming a positive feedback loop of the autocrine signaling. This mechanism can operate independently of, or in conjunction with, a direct stress-sensing due to mechanotransduction.


Subject(s)
Autocrine Communication , Convection , Hydrodynamics , Models, Biological , Animals , Humans , Nonlinear Dynamics
2.
Biophys J ; 102(5): 990-1000, 2012 Mar 07.
Article in English | MEDLINE | ID: mdl-22404921

ABSTRACT

We study effects of convective transport on a chemical front wave representing a signal propagation at a simple (single layer) epithelium by means of mathematical modeling. Plug flow and laminar flow regimes were considered. We observed a nonmonotonous dependence of the propagation velocity on the ligand receptor binding constant under influence of the convective transport. If the signal propagates downstream, the region of high velocities becomes much broader and spreads over several orders of magnitude of the binding constant. When the convective transport is oriented against the propagating signal, either velocity of the traveling front wave is slowed down or the traveling front wave can stop or reverse the direction of propagation. More importantly, chemical signal in epithelial systems influenced by the convective transport can propagate almost independently of the ligand-receptor binding constant in a broad range of this parameter. Furthermore, we found that the effects of the convective transport becomes more significant in systems where either the characteristic dimension of the extracellular space is larger/comparable with the spatial extent of the ligand diffusion trafficking or the ligand-receptor binding/ligand diffusion rate ratio is high.


Subject(s)
Models, Biological , Signal Transduction , Epithelium/metabolism , Feedback, Physiological , Intercellular Signaling Peptides and Proteins/metabolism , Ligands , Protein Transport
3.
Biomicrofluidics ; 5(1): 14101, 2011 Feb 03.
Article in English | MEDLINE | ID: mdl-21359027

ABSTRACT

We developed an automated laser induced fluorescence system utilizing microfluidic chips for detection and quantification of immunoglobulins. Microchips were fabricated from polydimethysiloxane (PDMS) using the so-called "prepolymerization technique." The microchip structure helped minimize the effects of PDMS autofluorescence and light scattering. Furthermore, a thin and uniform PDMS layer forming the top of the microchip enabled proper focusing and collection of the excitation beam and the emitted fluorescence, respectively. The developed system was tested for the detection of mouse immunoglobulins. The capturing antibodies were immobilized on internal microchannel walls in the form of a polyelectrolyte. We clearly show that this immobilization technique, if correctly realized, gives results with high reproducibility. After sample incubation and washing, secondary antibodies labeled by fluorescein isothiocyanate were introduced into microchannels to build a detectable complex. We show that mouse antibodies can be quantified in a wide concentration range, 0.01-100 µg ml(-1). The lower detection limit was below 0.001 µg ml(-1) (6.7 pM). The developed laser induced fluorescence (LIF) apparatus is relatively cheap and easy to construct. The total cost of the developed LIF detector is lower than a typical price of plate readers. If compared to classical ELISA (enzyme linked immunosorbent assay) plate systems, the detection of immunoglobulins or other proteins in the developed PDMS microfluidic device brings other important benefits such as reduced time demands (10 min incubation) and low reagent consumption (less than 1 µl). The cost of the developed PDMS chips is comparable with the price of commercial ELISA plates. The main troubleshooting related to the apparatus development is also discussed in order to help potential constructors.

4.
Biomicrofluidics ; 3(4): 44101, 2009 Oct 12.
Article in English | MEDLINE | ID: mdl-20216963

ABSTRACT

Electrokinetic properties and morphology of PDMS microfluidic chips intended for bioassays are studied. The chips are fabricated by a casting method followed by polymerization bonding. Microchannels are coated with 1% solution of bovine serum albumin (BSA) in Tris buffer. Albumin passively adsorbs on the PDMS surface. Electrokinetic characteristics (electro-osmotic velocity, electro-osmotic mobility, and zeta potential) of the coated PDMS channels are experimentally determined as functions of the electric field strength and the characteristic electrolyte concentration. Atomic force microscopy (AFM) analysis of the surface reveals a "peak and ridge" structure of the protein layer and an imperfect substrate coating. On the basis of the AFM observation, several topologies of the BSA-PDMS surface are proposed. A nonslip mathematical model of the electro-osmotic flow is then numerically analyzed. It is found that the electrokinetic characteristics computed for a channel with the homogeneous distribution of a fixed electric charge do not fit the experimental data. Heterogeneous distribution of the fixed electric charge and the surface roughness is thus taken into account. When a flat PDMS surface with electric charge heterogeneities is considered, the numerical results are in very good agreement with our experimental data. An optimization analysis finally allowed the determination of the surface concentration of the electric charge and the degree of the PDMS surface coating. The obtained findings can be important for correct prediction and possibly for robust control of behavior of electrically driven PDMS microfluidic chips. The proposed method of the electro-osmotic flow analysis at surfaces with a heterogeneous distribution of the surface electric charge can also be exploited in the interpretation of experimental studies dealing with protein-solid phase interactions or substrate coatings.