Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Indian J Thorac Cardiovasc Surg ; 37(5): 514-520, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34511757

ABSTRACT

OBJECTIVE: A growing number of patients suffering from heart failure is living with a left ventricular assist device (LVAD) and is in the need for non-cardiac surgery. Vascular procedures due to ischemia, bleeding, or other device-related complications may be required and pose a challenge to the caregivers in terms of monitoring and management of these patients. Therefore, we reviewed our experience with LVAD patients undergoing vascular surgery. METHODS: From January 2010 until March 2017, a total of 54 vascular procedures were performed on 41 LVAD patients at our institution. Patient records were reviewed retrospectively in terms of incidence of LVAD-related complications, including thrombosis, stroke, bleeding, wound healing, and survival associated with vascular surgery. The type of surgery was recorded, as well as various clinical demographic variables. RESULTS: Vascular procedures were performed in 35 men (85.4%) and 6 women (14.6%) with LVADs. There were no perioperative strokes, device thromboses, or device malfunctions. Thirty-day mortality overall was 26.8% (eleven patients), with most patients dying within 30 days after LVAD implantation due to multi-organ failure. In 25 procedures (46.3%), a blood transfusion was necessary. CONCLUSION: Patients on LVAD support are a complex cohort with a high risk for perioperative complications. In a setting where device function and anticoagulation are monitored closely, vascular surgery in these patients is feasible with an acceptable perioperative risk.

2.
Eur J Cardiothorac Surg ; 55(3): 476-483, 2019 Mar 01.
Article in English | MEDLINE | ID: mdl-30169770

ABSTRACT

OBJECTIVES: Valve-sparing aortic root replacement (VSARR) is recommended for patients with aortic root dilatation and preserved aortic valve cusp morphology. The durability of VSARR in Marfan patients has been questioned. The aim of our study was to establish the long-term outcomes of VSARR in Marfan patients. METHODS: Between 1993 and 2015, 582 patients underwent VSARR (David I reimplantation) at our institution. Of these patients, 104 had Marfan disease. Thirteen surgeons performed the procedures in this group. The mean follow-up time was 12 ± 5.4 years (1201 patient-years). RESULTS: Early mortality was 0.96%, and long-term survival was 91% at 10 years and 76% at 20 years in Marfan patients. Marfan patients had a significantly better survival compared to non-Marfan patients (P < 0.0001). Freedom from aortic-valve reoperation was 86% at 10 years and 80% at 20 years in Marfan patients. The reoperation rate was similar in Marfan and non-Marfan patients (P = 0.60). Morphological perioperative features (untreated prolapse, commissural plasty, cusp plasty and graft size mismatch) predicted long-term mortality (P = 0.0054). Graft size mismatch and untreated prolapse predicted structural valve deterioration (both P < 0.0001). Long-term valve function in event-free survivors was excellent [mean gradient 4.2 (2.9-6.9), 98% aortic regurgitation ≤ mild]. There were no valve-related thromboembolic or bleeding events. The endocarditis rate was 0.96%. Only 17% of the patients were on oral anticoagulants during the follow-up. CONCLUSIONS: VSARR using the David I reimplantation technique results in excellent long-term outcomes in Marfan patients. We present the longest follow-up period so far. The genetic disease does not affect long-term valve function. The durability of the repair is affected by morphological perioperative criteria depending on surgical expertise, and dedicated training is recommended.


Subject(s)
Aortic Diseases/etiology , Aortic Diseases/surgery , Aortic Valve , Marfan Syndrome/complications , Organ Sparing Treatments/methods , Adult , Female , Follow-Up Studies , Humans , Male , Middle Aged , Retrospective Studies , Time Factors , Treatment Outcome , Vascular Surgical Procedures/methods , Young Adult
3.
Eur J Cardiothorac Surg ; 52(5): 858-866, 2017 Nov 01.
Article in English | MEDLINE | ID: mdl-28977379

ABSTRACT

OBJECTIVES: Our goal was to present our 15-year experience (2001-2015) with the frozen elephant trunk (FET) technique. METHODS: A total of 251 patients (82 with aortic aneurysms, 96 with acute aortic dissection type A, 4 with acute type B dissections, 52 with chronic aortic dissection type A, 17 with chronic type B dissection and 67 redo cases) underwent FET implantation with either the custom-made Chavan-Haverich (n = 66), the Jotec E-vita (n = 31) or the Vascutek Thoraflex hybrid (n = 154) prosthesis. The cases were assigned to an early period (2001-2011) and a contemporary period (2012-present). RESULTS: Mean cardiopulmonary bypass time, aortic cross-clamp time, circulatory arrest time and selective antegrade cerebral perfusion time were 241 ± 72, 125 ± 59, 56 ± 30 and 81 ± 34 min, respectively. Incidence of rethoracotomy for bleeding, stroke, spinal cord injury, prolonged ventilatory support (>96 h) and long-term dialysis were 18, 14, 2, 24 and 2%, respectively. The in-hospital mortality rate was 11% (in acute aortic dissection type A, 12%). Of the 2 patients with graft infections, 1 died and the other had a protracted hospital stay. There were 49 second-stage procedures in the downstream aorta: either open surgical [n = 25 (thoraco-abdominal, n = 15; descending, n = 6; infrarenal, n = 4)] or transfemoral endovascular (n = 23). Elective thoracic endovascular aneurysm repair R implantation was successful in all 23 cases. CONCLUSIONS: FET results are comparable with those of the published results of the conventional elephant trunk technique. FET is an ideal landing zone for subsequent transfemoral endovascular completion. Patients with graft infections may have dismal results.


Subject(s)
Aortic Aneurysm/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation , Aged , Aortic Dissection/diagnostic imaging , Aorta/diagnostic imaging , Aorta/surgery , Aortic Aneurysm/diagnostic imaging , Blood Vessel Prosthesis Implantation/methods , Blood Vessel Prosthesis Implantation/mortality , Blood Vessel Prosthesis Implantation/statistics & numerical data , Computed Tomography Angiography , Female , Humans , Male , Middle Aged , Reoperation/statistics & numerical data , Retrospective Studies , Thoracotomy
SELECTION OF CITATIONS
SEARCH DETAIL
...