1.
Tech Coloproctol ; 20(3): 163-9, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26757901

ABSTRACT

BACKGROUND: Splenic injury following colonoscopy is a rare yet life-threatening complication. These injuries are often associated with delayed diagnosis and may require invasive intervention. We sought to study the emergent presentation associated with splenic injury post-colonoscopy and to suggest a new treatment algorithm. METHODS: Six cases of splenic injury following colonoscopy were collected from three medical centers. Data regarding patient medical history, clinical presentation, laboratory and imaging findings and clinical management were recorded. A systematic PubMed/MEDLINE search was performed. Non-English-language publications and publications dating earlier than 2010 were excluded. An emergency department trauma-based management algorithm was designed according to the identified publications and review of the available trauma literature. RESULTS: The mean age was 65.3 years and the male-to-female ratio was 1:5. Five of the cases presented within 24 h of the colonoscopy complaining of severe abdominal pain. Hemodynamic instability was noted in four patients who presented with tachycardia (105-130), hypotension and/or a rapid drop in hemoglobin levels. All of the patients underwent initial resuscitation and a computerized abdominal tomography scan. Four of them required emergent splenectomy. No mortality or major morbidity was reported following the hospitalization. CONCLUSIONS: Although very rare, splenic injury during colonoscopy is an acute, severe and possible fatal complication. Patients may present with a rapid clinical deterioration and hemodynamic instability. Physicians should be familiar with the practical management of this surgical emergency and the treatment options available.


Subject(s)
Algorithms , Colonoscopy/adverse effects , Spleen/diagnostic imaging , Abdominal Pain/diagnostic imaging , Abdominal Pain/etiology , Abdominal Pain/surgery , Aged , Female , Humans , Male , Middle Aged , Spleen/injuries , Spleen/surgery , Splenectomy , Tomography, X-Ray Computed
2.
Tech Coloproctol ; 18(6): 551-6, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24287642

ABSTRACT

BACKGROUND: Colorectal stents have a proven role in colorectal cancer as palliative care or a bridge to surgery. However, their efficacy and anchoring to the tissue varies according to stent design with stent migration rates up to 50 %. We present preliminary in vivo results of a new end-luminal anchoring system for stent fixation to the rectal canal. The aim was to assess the efficacy and safety of the stent using the anchoring system while subjecting the device to daily abdominal pressures related to daily activities in a porcine animal model. METHODS: Ex vivo anatomical and physical studies were performed to improve the system's structure and safety. Four female pigs were followed for the acute and chronic (16 weeks) period. Two animals were euthanized and underwent en-bloc pelvic visceral excision and histopathological examination. Device fixation time, animal behavior, device patency, anoscopic examination and histopathological features were assessed. RESULTS: Mean anchoring time was 13.83 weeks (standard error ± 1.38 weeks). One of the animals experienced early device expulsion with no complications. No obstruction was noted in any of the animals. Macroscopic examination revealed mild focal submucosal scarring in one animal and a normal examination in the other. Hematoxylin and eosin staining revealed mucosal ulceration and mixed inflammatory cell infiltrate, with no signs of granulomata, foreign body giant cell reaction or microabscess formation. CONCLUSIONS: A novel fixation device designed for long-term intrarectal implantation was well tolerated and maintained anal canal patency without migration. Larger studies are needed before its implementation in humans.


Subject(s)
Rectum/surgery , Stents , Animals , Colorectal Neoplasms/complications , Colorectal Neoplasms/surgery , Disease Models, Animal , Female , Foreign-Body Migration , Intestinal Obstruction/etiology , Intestinal Obstruction/surgery , Prosthesis Design , Swine , Time Factors , Titanium
3.
Colorectal Dis ; 15(8): 1011-8, 2013 Aug.
Article in English | MEDLINE | ID: mdl-23489598

ABSTRACT

AIM: Successful anal fistula care is aided by specialized imaging accurately defining the site of the internal opening and fistula type. Imaging techniques are complementary, designed to answer specific anatomical questions. There are limited data concerning the clinical value of transperineal ultrasound (TP-US) in both cryptogenic fistula-in-ano and perianal Crohn's disease (PACD). The aim of the study was to assess the accuracy of TP-US compared with operative findings in patients with perirectal sepsis. METHOD: Patients with recurrent cryptogenic anal fistula and PACD referred for sonography were examined using TP-US by a single examiner blinded to the operative results. Fistulae were categorized by the Parks classification predicting the site of the internal fistula opening. Ancillary horseshoe collections, abscesses and secondary tracks were defined. RESULTS: Fourteen patients with PACD and 27 patients with recurrent cryptogenic fistula-in-ano were analysed with comparative images and operative data. Correlation of fistula type for cryptogenic and PACD patients respectively was 23/27 (85.2%) and 12/14 (85.7%), with a correlative internal opening site (when found at surgery) of 16/22 (72.3%) and 12/14 (85.7%). Misclassification of fistula type in cryptogenic cases occurred in the presence of ancillary abscesses with associated acoustic shadowing. In PACD patients, TP-US was used when anal stenosis precluded endoanal ultrasonography, assisting in the diagnosis of recto-vaginal fistulae. CONCLUSION: TP-US is a useful complementary technique to assess fistula-in-ano and has special advantage when there is anal canal distortion, complex fistula type or suspicion of a recto-vaginal fistula.


Subject(s)
Anal Canal/diagnostic imaging , Crohn Disease/diagnostic imaging , Endosonography/methods , Rectal Fistula/diagnostic imaging , Rectovaginal Fistula/diagnostic imaging , Adolescent , Adult , Aged , Child , Child, Preschool , Crohn Disease/surgery , Female , Humans , Male , Middle Aged , Rectal Fistula/surgery , Recurrence , Retrospective Studies
SELECTION OF CITATIONS