Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
2.
J Am Coll Surg ; 228(5): 730-743, 2019 05.
Article in English | MEDLINE | ID: mdl-30769112

ABSTRACT

BACKGROUND: Misidentifying parathyroid glands (PGs) during thyroidectomies or parathyroidectomies could significantly increase postoperative morbidity. Imaging systems based on near infrared autofluorescence (NIRAF) detection can localize PGs with high accuracy. These devices, however, depict NIRAF images on remote display monitors, where images lack spatial context and comparability with actual surgical field of view. In this study, we designed an overlay tissue imaging system (OTIS) that detects tissue NIRAF and back-projects the collected signal as a visible image directly onto the surgical field of view instead of a display monitor, and tested its ability for enhancing parathyroid visualization. STUDY DESIGN: The OTIS was first calibrated with a fluorescent ink grid and initially tested with parathyroid, thyroid, and lymph node tissues ex vivo. For in vivo measurements, the surgeon's opinion on tissue of interest was first ascertained. After the surgeon looked away, the OTIS back-projected visible green light directly onto the tissue of interest, only if the device detected relatively high NIRAF as observed in PGs. System accuracy was determined by correlating NIRAF projection with surgeon's visual confirmation for in situ PGs or histopathology report for excised PGs. RESULTS: The OTIS yielded 100% accuracy when tested ex vivo with parathyroid, thyroid, and lymph node specimens. Subsequently, the device was evaluated in 30 patients who underwent thyroidectomy and/or parathyroidectomy. Ninety-seven percent of exposed tissue of interest was visualized correctly as PGs by the OTIS, without requiring display monitors or contrast agents. CONCLUSIONS: Although OTIS holds novel potential for enhancing label-free parathyroid visualization directly within the surgical field of view, additional device optimization is required for eventual clinical use.


Subject(s)
Image Enhancement/methods , Optical Imaging/methods , Parathyroid Glands/diagnostic imaging , Spectroscopy, Near-Infrared/methods , Adult , Aged , Equipment Design , Female , Fluorescence , Humans , Image Enhancement/instrumentation , Male , Middle Aged , Optical Imaging/instrumentation , Parathyroid Diseases/diagnostic imaging , Parathyroid Diseases/surgery , Parathyroid Glands/surgery , Parathyroidectomy , Phantoms, Imaging , Spectroscopy, Near-Infrared/instrumentation , Surgery, Computer-Assisted , Thyroid Diseases/diagnostic imaging , Thyroid Diseases/surgery , Thyroidectomy
3.
Surgery ; 165(1): 114-123, 2019 01.
Article in English | MEDLINE | ID: mdl-30442424

ABSTRACT

BACKGROUND: Difficulty in identifying the parathyroid gland during neck operations can lead to accidental parathyroid gland excisions and postsurgical hypocalcemia. A clinical prototype called as PTeye was developed to guide parathyroid gland identification using a fiber-optic probe that detects near-infrared autofluorescence from parathyroid glands as operating room lights remain on. An Overlay Tissue Imaging System was designed concurrently to detect near-infrared autofluorescence and project visible light precisely onto parathyroid gland location. METHODS: The PTeye and the Overlay Tissue Imaging System were tested in 20 and 15 patients, respectively, and a modified near-infrared imaging system was investigated in 6 patients. All 41 patients underwent thyroidectomy or parathyroidectomy. System accuracy was ascertained with surgeon's visual confirmation for in situ parathyroid glands and histology for excised parathyroid glands. RESULTS: There was no observable difference between near-infrared autofluorescence of healthy and diseased parathyroid glands. The PTeye identified 98% of the parathyroid gland, whereas the near-infrared imaging system and the Overlay Tissue Imaging System identified 100% and 97% of the parathyroid glands, respectively. CONCLUSION: The PTeye can guide in real-time parathyroid gland identification even with ambient operating room lights. The near-infrared imaging system performs parathyroid gland imaging with high sensitivity, whereas the Overlay Tissue Imaging System enhances parathyroid gland visualization directly within the surgical field without requiring display monitors. These label-free technologies can be valuable adjuncts for identifying parathyroid glands intraoperatively.


Subject(s)
Fiber Optic Technology/instrumentation , Intraoperative Complications/prevention & control , Optical Imaging/instrumentation , Parathyroid Glands/diagnostic imaging , Adult , Aged , Female , Humans , Male , Middle Aged , Parathyroidectomy , Thyroidectomy , Young Adult
4.
Lasers Surg Med ; 48(8): 774-781, 2016 10.
Article in English | MEDLINE | ID: mdl-27454580

ABSTRACT

BACKGROUND AND OBJECTIVE: Soft tissue sarcomas (STS) are a rare and heterogeneous group of malignant tumors that are often treated through surgical resection. Current intraoperative margin assessment methods are limited and highlight the need for an improved approach with respect to time and specificity. Here we investigate the potential of near-infrared Raman spectroscopy for the intraoperative differentiation of STS from surrounding normal tissue. MATERIALS AND METHODS: In vivo Raman measurements at 785 nm excitation were intraoperatively acquired from subjects undergoing STS resection using a probe based spectroscopy system. A multivariate classification algorithm was developed in order to automatically identify spectral features that can be used to differentiate STS from the surrounding normal muscle and fat. The classification algorithm was subsequently tested using leave-one-subject-out cross-validation. RESULTS: With the exclusion of well-differentiated liposarcomas, the algorithm was able to classify STS from the surrounding normal muscle and fat with a sensitivity and specificity of 89.5% and 96.4%, respectively. CONCLUSION: These results suggest that single point near-infrared Raman spectroscopy could be utilized as a rapid and non-destructive surgical guidance tool for identifying abnormal tissue margins in need of further excision. Lasers Surg. Med. 48:774-781, 2016. © 2016 Wiley Periodicals, Inc.


Subject(s)
Intraoperative Care/methods , Margins of Excision , Sarcoma/diagnosis , Soft Tissue Neoplasms/diagnosis , Spectrum Analysis, Raman , Adult , Algorithms , Humans , Logistic Models , Multivariate Analysis , Sarcoma/surgery , Sensitivity and Specificity , Soft Tissue Neoplasms/surgery
5.
J Biomed Opt ; 19(8): 086011, 2014 Aug.
Article in English | MEDLINE | ID: mdl-25120175

ABSTRACT

Extending the wavelength range of spatial frequency domain imaging (SFDI) into the short-wave infrared (SWIR) has the potential to provide enhanced sensitivity to chromophores such as water and lipids that have prominent absorption features in the SWIR region. Here, we present, for the first time, a method combining SFDI with unstructured (zero spatial frequency) illumination to extract tissue absorption and scattering properties over a wavelength range (850 to 1800 nm) largely unexplored by previous tissue optics techniques. To obtain images over this wavelength range, we employ a SWIR camera in conjunction with an SFDI system. We use SFDI to obtain in vivo tissue reduced scattering coefficients at the wavelengths from 850 to 1050 nm, and then use unstructured wide-field illumination and an extrapolated power-law fit to this scattering spectrum to extract the absorption spectrum from 850 to 1800 nm. Our proof-of-principle experiment in a rat burn model illustrates that the combination of multispectral SWIR imaging, SFDI, and unstructured illumination can characterize in vivo changes in skin optical properties over a greatly expanded wavelength range. In the rat burn experiment, these changes (relative to normal, unburned skin) included increased absorption and increased scattering amplitude and slope, consistent with changes that we previously reported in the near-infrared using SFDI.


Subject(s)
Algorithms , Burns/pathology , Optical Imaging/instrumentation , Optical Imaging/methods , Skin/chemistry , Skin/injuries , Spectroscopy, Near-Infrared/instrumentation , Spectroscopy, Near-Infrared/methods , Animals , Equipment Design , Equipment Failure Analysis , Pilot Projects , Rats , Rats, Sprague-Dawley , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...