Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Chim Acta ; 1255: 341141, 2023 May 15.
Article in English | MEDLINE | ID: mdl-37032056

ABSTRACT

This study reports on the development of a new concept of on-line dual preconcentration stages for capillary electrophoresis (CE), in which two completely different preconcentration approaches can be realized in the same capillary. In the first stage, a dynamic magneto-extraction of target analytes on circulating magnetic beads is implemented within the capillary. In the second one, electrokinetic preconcentration of eluted analytes via large volume sample stacking is carried out to focus them into a nano band, prior to CE separation of enriched analytes. To implement the dual-stage preconcentration operation, a purpose-made instrument was designed, combining electrophoretic and microfluidic modules to allow precise control of the movement of magnetic beads and analyte's flow. The potential of this new enrichment principle and its associated instrument was demonstrated for CE separation with light-emitting-diode-induced fluorescent (LEDIF) detection of target double-stranded DNA (ds-DNA). The workflow consists of purification and preconcentration of a target DNA fragment (300 bp) on negatively charged magnetic beads, followed by in-capillary elution and fluorescent labelling of the enriched DNA. Large volume sample stacking of the DNA eluent was then triggered to further preconcentrate the labelled DNA before its analysis by CE-LEDIF. An enrichment factor of 125 was achieved for the target DNA fragment. With our new approach, dual-stage sample pretreatment and CE separation can now be performed in-capillary without any mismatch of working volumes, nor any waste of pretreated samples.


Subject(s)
Coloring Agents , Electrophoresis, Capillary , Electrophoresis, Capillary/methods , Immunomagnetic Separation , Magnetic Fields , Microfluidics
2.
Anal Chim Acta ; 1161: 338466, 2021 May 29.
Article in English | MEDLINE | ID: mdl-33896565

ABSTRACT

It is reported in this study a new approach for modulation and even suppression of the electroosmotic flow (EOF) to achieve better electrokinetic preconcentration in capillary electrophoresis. This is based on the augmentation of the buffer's concentrations to very high levels (more than a thousand of mM) without recourse to any dynamic/permanent coating nor viscous gel. The use of large weakly charged molecules as background electrolyte's constituents allows working at extreme concentration ranges without penalty of high electric currents and Joule heating. By this way, the electroosmotic mobility could be modulated over a wide range (2-60 × 10-5 cm2 V-1 s-1 under alkaline conditions), and suppressed to levels equivalent to those obtained with several neutral coatings. The highest buffer concentrations, and the lowest EOF magnitudes, accordingly, were achieved with diethanolamine/3-(Cyclohexylamino)-1-propanesulfonic acid (ionic strength (IS) of 250 mM, pH 9.5), Tris(hydroxymethyl)aminomethane (Tris)/2-(Cyclohexylamino)ethanesulfonic acid (CHES) (IS of 280 mM, pH 8.7) and triethanolamine/2-(Cyclohexylamino)ethanesulfonic acid (IS of 250 mM, pH 8.5). For demonstration, this new approach was applied for sensitive determination of core-shell magnetic nanoparticles (CSMNPs) having high potential for healthcare applications such as imaging agents for diagnostics and controllable cargos for nanomedicine. Different profiles were achieved for purpose-made and commercial magnetic nanoparticles using CE coupled with light-emitting-diode induced fluorescence (LEDIF) detection. The best performance for EOF-assisted preconcentration and CE-LEDIF of CSMNPs was achieved with these nanoparticles prepared in TRIS/CHES (IS 10 mM, pH 8.4) for preconcentration, and separation under BGE of TRIS/CHES (IS 100 mM, pH 8.4). Compared to the conventional capillary electrophoresis (CE-UV) method for characterization of magnetic nanoparticles, our proposed approach with fluorescent detection and EOF-assisted preconcentration offers almost 350-fold sensitivity improvement. Furthermore, our scheme can be used for monitoring the interaction between CSMNPs and target pharmaceutical molecules, serving for drug delivery development. A preliminary study with two antibiotics using this approach revealed that kanamycin interacts better with the target nanoparticles than amikacin.


Subject(s)
Electroosmosis , Magnetite Nanoparticles , Coloring Agents , Electrophoresis, Capillary , Indicators and Reagents